  "sheet": "E8.0",
  "coordinateSpace": {
    "width": 1920,
    "height": 1280
  },
  "calibration": {
    "printedScale": "NTS / schedule sheet",
    "scaledTakeoffAllowed": false,
    "basis": "Detail, panel-schedule and COMcheck evidence only. No plan-scale conduit, conductor, duct, pipe, vertical, hidden route, slack or fitting quantity is derived."
  },
  "rows": [
    {
      "id": "e8-0-value-01",
      "label": "Interior · reviewed floor area",
      "quantity": 52994,
      "unit": "SF",
      "status": "PRINTED SOURCE VALUE",
      "basis": "Exact printed COMcheck aggregate; compliance evidence only, not an installed fixture count.",
      "sourceSheet": "E8.0",
      "line": [
        [
          97.78,
          275.56
        ],
        [
          506.67,
          275.56
        ],
        [
          506.67,
          810.67
        ],
        [
          97.78,
          810.67
        ],
        [
          97.78,
          275.56
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e8-0-value-02",
      "label": "Interior · allowed lighting power",
      "quantity": 24522,
      "unit": "W",
      "status": "PRINTED SOURCE VALUE",
      "basis": "Exact printed COMcheck aggregate; compliance evidence only, not an installed fixture count.",
      "sourceSheet": "E8.0",
      "line": [
        [
          97.78,
          275.56
        ],
        [
          506.67,
          275.56
        ],
        [
          506.67,
          810.67
        ],
        [
          97.78,
          810.67
        ],
        [
          97.78,
          275.56
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e8-0-value-03",
      "label": "Interior · proposed lighting power",
      "quantity": 16876,
      "unit": "W",
      "status": "PRINTED SOURCE VALUE",
      "basis": "Exact printed COMcheck aggregate; compliance evidence only, not an installed fixture count.",
      "sourceSheet": "E8.0",
      "line": [
        [
          506.67,
          275.56
        ],
        [
          915.56,
          275.56
        ],
        [
          915.56,
          810.67
        ],
        [
          506.67,
          810.67
        ],
        [
          506.67,
          275.56
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e8-0-value-04",
      "label": "Exterior · reviewed tradable area",
      "quantity": 17935,
      "unit": "SF",
      "status": "PRINTED SOURCE VALUE",
      "basis": "Exact printed COMcheck aggregate; compliance evidence only, not an installed fixture count.",
      "sourceSheet": "E8.0",
      "line": [
        [
          924.44,
          275.56
        ],
        [
          1335.11,
          275.56
        ],
        [
          1335.11,
          810.67
        ],
        [
          924.44,
          810.67
        ],
        [
          924.44,
          275.56
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e8-0-value-05",
      "label": "Exterior · allowed lighting power",
      "quantity": 1344,
      "unit": "W",
      "status": "PRINTED SOURCE VALUE",
      "basis": "Exact printed COMcheck aggregate; compliance evidence only, not an installed fixture count.",
      "sourceSheet": "E8.0",
      "line": [
        [
          924.44,
          275.56
        ],
        [
          1335.11,
          275.56
        ],
        [
          1335.11,
          810.67
        ],
        [
          924.44,
          810.67
        ],
        [
          924.44,
          275.56
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e8-0-value-06",
      "label": "Exterior · supplemental allowance",
      "quantity": 500,
      "unit": "W",
      "status": "PRINTED SOURCE VALUE",
      "basis": "Exact printed COMcheck aggregate; compliance evidence only, not an installed fixture count.",
      "sourceSheet": "E8.0",
      "line": [
        [
          924.44,
          275.56
        ],
        [
          1335.11,
          275.56
        ],
        [
          1335.11,
          810.67
        ],
        [
          924.44,
          810.67
        ],
        [
          924.44,
          275.56
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e8-0-value-07",
      "label": "Exterior · proposed lighting power",
      "quantity": 1198,
      "unit": "W",
      "status": "PRINTED SOURCE VALUE",
      "basis": "Exact printed COMcheck aggregate; compliance evidence only, not an installed fixture count.",
      "sourceSheet": "E8.0",
      "line": [
        [
          924.44,
          275.56
        ],
        [
          1335.11,
          275.56
        ],
        [
          1335.11,
          810.67
        ],
        [
          924.44,
          810.67
        ],
        [
          924.44,
          275.56
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    }
  ]
}