  "sheet": "E6.0",
  "coordinateSpace": {
    "width": 1920,
    "height": 1280
  },
  "calibration": {
    "printedScale": "NTS / schedule sheet",
    "scaledTakeoffAllowed": false,
    "basis": "Cut-sheet and panel-schedule evidence. No plan-scale length, conduit, conductor, duct, pipe, vertical, hidden route, slack or fitting quantity is derived."
  },
  "rows": [
    {
      "id": "e6-0-value-01",
      "label": "L5.A · Connected load",
      "quantity": 172460,
      "unit": "VA",
      "status": "PRINTED SCHEDULE VALUE",
      "basis": "Exact printed panel-schedule summary value. Schedule evidence only; not an additional installed occurrence.",
      "sourceSheet": "E6.0",
      "line": [
        [
          94,
          80
        ],
        [
          834,
          80
        ],
        [
          834,
          361
        ],
        [
          94,
          361
        ],
        [
          94,
          80
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e6-0-value-02",
      "label": "L5.A · Demand load",
      "quantity": 73453,
      "unit": "VA",
      "status": "PRINTED SCHEDULE VALUE",
      "basis": "Exact printed panel-schedule summary value. Schedule evidence only; not an additional installed occurrence.",
      "sourceSheet": "E6.0",
      "line": [
        [
          94,
          80
        ],
        [
          834,
          80
        ],
        [
          834,
          361
        ],
        [
          94,
          361
        ],
        [
          94,
          80
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e6-0-value-03",
      "label": "L5.A · Connected current",
      "quantity": 479,
      "unit": "A",
      "status": "PRINTED SCHEDULE VALUE",
      "basis": "Exact printed panel-schedule summary value. Schedule evidence only; not an additional installed occurrence.",
      "sourceSheet": "E6.0",
      "line": [
        [
          94,
          80
        ],
        [
          834,
          80
        ],
        [
          834,
          361
        ],
        [
          94,
          361
        ],
        [
          94,
          80
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e6-0-value-04",
      "label": "L5.A · Demand current",
      "quantity": 204,
      "unit": "A",
      "status": "PRINTED SCHEDULE VALUE",
      "basis": "Exact printed panel-schedule summary value. Schedule evidence only; not an additional installed occurrence.",
      "sourceSheet": "E6.0",
      "line": [
        [
          94,
          80
        ],
        [
          834,
          80
        ],
        [
          834,
          361
        ],
        [
          94,
          361
        ],
        [
          94,
          80
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e6-0-value-05",
      "label": "L4.B · Connected load",
      "quantity": 164804,
      "unit": "VA",
      "status": "PRINTED SCHEDULE VALUE",
      "basis": "Exact printed panel-schedule summary value. Schedule evidence only; not an additional installed occurrence.",
      "sourceSheet": "E6.0",
      "line": [
        [
          866,
          80
        ],
        [
          1608,
          80
        ],
        [
          1608,
          361
        ],
        [
          866,
          361
        ],
        [
          866,
          80
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e6-0-value-06",
      "label": "L4.B · Demand load",
      "quantity": 67570,
      "unit": "VA",
      "status": "PRINTED SCHEDULE VALUE",
      "basis": "Exact printed panel-schedule summary value. Schedule evidence only; not an additional installed occurrence.",
      "sourceSheet": "E6.0",
      "line": [
        [
          866,
          80
        ],
        [
          1608,
          80
        ],
        [
          1608,
          361
        ],
        [
          866,
          361
        ],
        [
          866,
          80
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e6-0-value-07",
      "label": "L4.B · Connected current",
      "quantity": 458,
      "unit": "A",
      "status": "PRINTED SCHEDULE VALUE",
      "basis": "Exact printed panel-schedule summary value. Schedule evidence only; not an additional installed occurrence.",
      "sourceSheet": "E6.0",
      "line": [
        [
          866,
          80
        ],
        [
          1608,
          80
        ],
        [
          1608,
          361
        ],
        [
          866,
          361
        ],
        [
          866,
          80
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e6-0-value-08",
      "label": "L4.B · Demand current",
      "quantity": 188,
      "unit": "A",
      "status": "PRINTED SCHEDULE VALUE",
      "basis": "Exact printed panel-schedule summary value. Schedule evidence only; not an additional installed occurrence.",
      "sourceSheet": "E6.0",
      "line": [
        [
          866,
          80
        ],
        [
          1608,
          80
        ],
        [
          1608,
          361
        ],
        [
          866,
          361
        ],
        [
          866,
          80
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e6-0-value-09",
      "label": "L5.B · Connected load",
      "quantity": 162534,
      "unit": "VA",
      "status": "PRINTED SCHEDULE VALUE",
      "basis": "Exact printed panel-schedule summary value. Schedule evidence only; not an additional installed occurrence.",
      "sourceSheet": "E6.0",
      "line": [
        [
          94,
          394
        ],
        [
          834,
          394
        ],
        [
          834,
          673
        ],
        [
          94,
          673
        ],
        [
          94,
          394
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e6-0-value-10",
      "label": "L5.B · Demand load",
      "quantity": 66639,
      "unit": "VA",
      "status": "PRINTED SCHEDULE VALUE",
      "basis": "Exact printed panel-schedule summary value. Schedule evidence only; not an additional installed occurrence.",
      "sourceSheet": "E6.0",
      "line": [
        [
          94,
          394
        ],
        [
          834,
          394
        ],
        [
          834,
          673
        ],
        [
          94,
          673
        ],
        [
          94,
          394
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e6-0-value-11",
      "label": "L5.B · Connected current",
      "quantity": 451,
      "unit": "A",
      "status": "PRINTED SCHEDULE VALUE",
      "basis": "Exact printed panel-schedule summary value. Schedule evidence only; not an additional installed occurrence.",
      "sourceSheet": "E6.0",
      "line": [
        [
          94,
          394
        ],
        [
          834,
          394
        ],
        [
          834,
          673
        ],
        [
          94,
          673
        ],
        [
          94,
          394
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e6-0-value-12",
      "label": "L5.B · Demand current",
      "quantity": 185,
      "unit": "A",
      "status": "PRINTED SCHEDULE VALUE",
      "basis": "Exact printed panel-schedule summary value. Schedule evidence only; not an additional installed occurrence.",
      "sourceSheet": "E6.0",
      "line": [
        [
          94,
          394
        ],
        [
          834,
          394
        ],
        [
          834,
          673
        ],
        [
          94,
          673
        ],
        [
          94,
          394
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e6-0-value-13",
      "label": "L3.A · Connected load",
      "quantity": 171870,
      "unit": "VA",
      "status": "PRINTED SCHEDULE VALUE",
      "basis": "Exact printed panel-schedule summary value. Schedule evidence only; not an additional installed occurrence.",
      "sourceSheet": "E6.0",
      "line": [
        [
          866,
          394
        ],
        [
          1608,
          394
        ],
        [
          1608,
          673
        ],
        [
          866,
          673
        ],
        [
          866,
          394
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e6-0-value-14",
      "label": "L3.A · Demand load",
      "quantity": 72863,
      "unit": "VA",
      "status": "PRINTED SCHEDULE VALUE",
      "basis": "Exact printed panel-schedule summary value. Schedule evidence only; not an additional installed occurrence.",
      "sourceSheet": "E6.0",
      "line": [
        [
          866,
          394
        ],
        [
          1608,
          394
        ],
        [
          1608,
          673
        ],
        [
          866,
          673
        ],
        [
          866,
          394
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e6-0-value-15",
      "label": "L3.A · Connected current",
      "quantity": 477,
      "unit": "A",
      "status": "PRINTED SCHEDULE VALUE",
      "basis": "Exact printed panel-schedule summary value. Schedule evidence only; not an additional installed occurrence.",
      "sourceSheet": "E6.0",
      "line": [
        [
          866,
          394
        ],
        [
          1608,
          394
        ],
        [
          1608,
          673
        ],
        [
          866,
          673
        ],
        [
          866,
          394
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e6-0-value-16",
      "label": "L3.A · Demand current",
      "quantity": 202,
      "unit": "A",
      "status": "PRINTED SCHEDULE VALUE",
      "basis": "Exact printed panel-schedule summary value. Schedule evidence only; not an additional installed occurrence.",
      "sourceSheet": "E6.0",
      "line": [
        [
          866,
          394
        ],
        [
          1608,
          394
        ],
        [
          1608,
          673
        ],
        [
          866,
          673
        ],
        [
          866,
          394
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e6-0-value-17",
      "label": "L4.A · Connected load",
      "quantity": 171429,
      "unit": "VA",
      "status": "PRINTED SCHEDULE VALUE",
      "basis": "Exact printed panel-schedule summary value. Schedule evidence only; not an additional installed occurrence.",
      "sourceSheet": "E6.0",
      "line": [
        [
          94,
          706
        ],
        [
          834,
          706
        ],
        [
          834,
          985
        ],
        [
          94,
          985
        ],
        [
          94,
          706
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e6-0-value-18",
      "label": "L4.A · Demand load",
      "quantity": 72422,
      "unit": "VA",
      "status": "PRINTED SCHEDULE VALUE",
      "basis": "Exact printed panel-schedule summary value. Schedule evidence only; not an additional installed occurrence.",
      "sourceSheet": "E6.0",
      "line": [
        [
          94,
          706
        ],
        [
          834,
          706
        ],
        [
          834,
          985
        ],
        [
          94,
          985
        ],
        [
          94,
          706
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e6-0-value-19",
      "label": "L4.A · Connected current",
      "quantity": 476,
      "unit": "A",
      "status": "PRINTED SCHEDULE VALUE",
      "basis": "Exact printed panel-schedule summary value. Schedule evidence only; not an additional installed occurrence.",
      "sourceSheet": "E6.0",
      "line": [
        [
          94,
          706
        ],
        [
          834,
          706
        ],
        [
          834,
          985
        ],
        [
          94,
          985
        ],
        [
          94,
          706
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e6-0-value-20",
      "label": "L4.A · Demand current",
      "quantity": 201,
      "unit": "A",
      "status": "PRINTED SCHEDULE VALUE",
      "basis": "Exact printed panel-schedule summary value. Schedule evidence only; not an additional installed occurrence.",
      "sourceSheet": "E6.0",
      "line": [
        [
          94,
          706
        ],
        [
          834,
          706
        ],
        [
          834,
          985
        ],
        [
          94,
          985
        ],
        [
          94,
          706
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e6-0-value-21",
      "label": "L3.B · Connected load",
      "quantity": 164804,
      "unit": "VA",
      "status": "PRINTED SCHEDULE VALUE",
      "basis": "Exact printed panel-schedule summary value. Schedule evidence only; not an additional installed occurrence.",
      "sourceSheet": "E6.0",
      "line": [
        [
          866,
          706
        ],
        [
          1608,
          706
        ],
        [
          1608,
          985
        ],
        [
          866,
          985
        ],
        [
          866,
          706
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e6-0-value-22",
      "label": "L3.B · Demand load",
      "quantity": 67570,
      "unit": "VA",
      "status": "PRINTED SCHEDULE VALUE",
      "basis": "Exact printed panel-schedule summary value. Schedule evidence only; not an additional installed occurrence.",
      "sourceSheet": "E6.0",
      "line": [
        [
          866,
          706
        ],
        [
          1608,
          706
        ],
        [
          1608,
          985
        ],
        [
          866,
          985
        ],
        [
          866,
          706
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e6-0-value-23",
      "label": "L3.B · Connected current",
      "quantity": 458,
      "unit": "A",
      "status": "PRINTED SCHEDULE VALUE",
      "basis": "Exact printed panel-schedule summary value. Schedule evidence only; not an additional installed occurrence.",
      "sourceSheet": "E6.0",
      "line": [
        [
          866,
          706
        ],
        [
          1608,
          706
        ],
        [
          1608,
          985
        ],
        [
          866,
          985
        ],
        [
          866,
          706
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e6-0-value-24",
      "label": "L3.B · Demand current",
      "quantity": 188,
      "unit": "A",
      "status": "PRINTED SCHEDULE VALUE",
      "basis": "Exact printed panel-schedule summary value. Schedule evidence only; not an additional installed occurrence.",
      "sourceSheet": "E6.0",
      "line": [
        [
          866,
          706
        ],
        [
          1608,
          706
        ],
        [
          1608,
          985
        ],
        [
          866,
          985
        ],
        [
          866,
          706
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    }
  ]
}