  "sheet": "E3.1",
  "coordinateSpace": {
    "width": 1920,
    "height": 1280
  },
  "calibration": {
    "printedScale": "1/8 inch = 1 foot",
    "pdfPointsPerFoot": 9,
    "sourcePixelsPerFoot": 37.5,
    "normalizedUnitsPerFoot": 6.6666667,
    "independentDimensionCheck": false,
    "scaledTakeoffAllowed": false,
    "basis": "Printed view scale verified to PDF/raster geometry; no independent dimension chain is printed. LF is visible drawn-path information only, not installed routing, conduit or conductor LF."
  },
  "rows": [
    {
      "id": "e31-path-001",
      "label": "L2.A-26 west/central corridor receptacles",
      "quantity": 28.082,
      "unit": "LF",
      "status": "DRAWN PATH · PRINTED SCALE ONLY",
      "basis": "Measured along the saved visible source polyline at 6.6666667 normalized units/ft. Not installed routing, conduit or conductor LF; no verticals, slack or hidden continuation.",
      "sourceSheet": "E3.1",
      "line": [
        [
          298.89,
          408.97
        ],
        [
          311.48,
          418.67
        ],
        [
          324.77,
          427.07
        ],
        [
          338.66,
          434.15
        ],
        [
          353.06,
          439.91
        ],
        [
          367.86,
          444.32
        ],
        [
          382.97,
          447.37
        ],
        [
          398.3,
          449.04
        ],
        [
          413.74,
          449.32
        ],
        [
          429.2,
          448.19
        ],
        [
          444.58,
          445.65
        ],
        [
          459.79,
          441.67
        ],
        [
          474.73,
          436.23
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e31-path-002",
      "label": "L2.A-26 west/central corridor receptacles",
      "quantity": 34.359,
      "unit": "LF",
      "status": "DRAWN PATH · PRINTED SCALE ONLY",
      "basis": "Measured along the saved visible source polyline at 6.6666667 normalized units/ft. Not installed routing, conduit or conductor LF; no verticals, slack or hidden continuation.",
      "sourceSheet": "E3.1",
      "line": [
        [
          698.05,
          408.94
        ],
        [
          679.15,
          405.5
        ],
        [
          660.15,
          403.11
        ],
        [
          641.11,
          401.78
        ],
        [
          622.07,
          401.49
        ],
        [
          603.07,
          402.24
        ],
        [
          584.15,
          404.03
        ],
        [
          565.35,
          406.85
        ],
        [
          546.73,
          410.69
        ],
        [
          528.31,
          415.56
        ],
        [
          510.15,
          421.43
        ],
        [
          492.29,
          428.32
        ],
        [
          474.77,
          436.21
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e31-path-003",
      "label": "L2.A-26 west/central corridor receptacles",
      "quantity": 39.026,
      "unit": "LF",
      "status": "DRAWN PATH · PRINTED SCALE ONLY",
      "basis": "Measured along the saved visible source polyline at 6.6666667 normalized units/ft. Not installed routing, conduit or conductor LF; no verticals, slack or hidden continuation.",
      "sourceSheet": "E3.1",
      "line": [
        [
          698.04,
          408.93
        ],
        [
          705.38,
          412.44
        ],
        [
          712.8,
          415.78
        ],
        [
          720.27,
          418.93
        ],
        [
          727.82,
          421.96
        ],
        [
          735.47,
          424.8
        ],
        [
          743.11,
          427.51
        ],
        [
          750.84,
          430.0
        ],
        [
          758.62,
          432.36
        ],
        [
          766.49,
          434.53
        ],
        [
          774.36,
          436.53
        ],
        [
          782.27,
          438.36
        ],
        [
          790.22,
          440.04
        ],
        [
          798.22,
          441.51
        ],
        [
          806.27,
          442.8
        ],
        [
          814.31,
          443.96
        ],
        [
          822.4,
          444.89
        ],
        [
          830.49,
          445.69
        ],
        [
          838.58,
          446.31
        ],
        [
          846.71,
          446.71
        ],
        [
          854.84,
          446.98
        ],
        [
          862.98,
          447.07
        ],
        [
          871.07,
          446.93
        ],
        [
          879.2,
          446.67
        ],
        [
          887.33,
          446.22
        ],
        [
          895.42,
          445.56
        ],
        [
          903.51,
          444.76
        ],
        [
          911.6,
          443.78
        ],
        [
          919.64,
          442.62
        ],
        [
          927.64,
          441.29
        ],
        [
          935.64,
          439.78
        ],
        [
          943.6,
          438.09
        ],
        [
          951.51,
          436.22
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e31-path-004",
      "label": "L2.A-28 east corridor/elevator/storage receptacles",
      "quantity": 37.558,
      "unit": "LF",
      "status": "DRAWN PATH · PRINTED SCALE ONLY",
      "basis": "Measured along the saved visible source polyline at 6.6666667 normalized units/ft. Not installed routing, conduit or conductor LF; no verticals, slack or hidden continuation.",
      "sourceSheet": "E3.1",
      "line": [
        [
          1204.84,
          408.93
        ],
        [
          1212.76,
          412.36
        ],
        [
          1220.76,
          415.64
        ],
        [
          1228.84,
          418.71
        ],
        [
          1236.93,
          421.64
        ],
        [
          1245.16,
          424.36
        ],
        [
          1253.38,
          426.93
        ],
        [
          1261.69,
          429.33
        ],
        [
          1270.0,
          431.56
        ],
        [
          1278.4,
          433.6
        ],
        [
          1286.84,
          435.47
        ],
        [
          1295.29,
          437.11
        ],
        [
          1303.82,
          438.62
        ],
        [
          1312.36,
          439.96
        ],
        [
          1320.89,
          441.07
        ],
        [
          1329.47,
          442.04
        ],
        [
          1338.09,
          442.8
        ],
        [
          1346.71,
          443.42
        ],
        [
          1355.33,
          443.82
        ],
        [
          1363.96,
          444.04
        ],
        [
          1372.58,
          444.09
        ],
        [
          1381.2,
          443.96
        ],
        [
          1389.82,
          443.6
        ],
        [
          1398.44,
          443.11
        ],
        [
          1407.07,
          442.4
        ],
        [
          1415.64,
          441.51
        ],
        [
          1424.22,
          440.49
        ],
        [
          1432.76,
          439.24
        ],
        [
          1441.29,
          437.82
        ],
        [
          1449.78,
          436.22
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e31-path-005",
      "label": "L2.A-28 east corridor/elevator/storage receptacles",
      "quantity": 31.922,
      "unit": "LF",
      "status": "DRAWN PATH · PRINTED SCALE ONLY",
      "basis": "Measured along the saved visible source polyline at 6.6666667 normalized units/ft. Not installed routing, conduit or conductor LF; no verticals, slack or hidden continuation.",
      "sourceSheet": "E3.1",
      "line": [
        [
          1449.73,
          436.23
        ],
        [
          1444.37,
          418.83
        ],
        [
          1437.23,
          402.39
        ],
        [
          1428.44,
          387.01
        ],
        [
          1418.11,
          372.79
        ],
        [
          1406.37,
          359.83
        ],
        [
          1393.35,
          348.22
        ],
        [
          1379.16,
          338.07
        ],
        [
          1363.93,
          329.47
        ],
        [
          1347.79,
          322.52
        ],
        [
          1330.85,
          317.32
        ],
        [
          1313.25,
          313.97
        ],
        [
          1295.09,
          312.57
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    },
    {
      "id": "e31-path-006",
      "label": "L2.A-28 east corridor/elevator/storage receptacles",
      "quantity": 10.177,
      "unit": "LF",
      "status": "DRAWN PATH · PRINTED SCALE ONLY",
      "basis": "Measured along the saved visible source polyline at 6.6666667 normalized units/ft. Not installed routing, conduit or conductor LF; no verticals, slack or hidden continuation.",
      "sourceSheet": "E3.1",
      "line": [
        [
          1295.11,
          312.56
        ],
        [
          1297.79,
          311.59
        ],
        [
          1300.39,
          310.45
        ],
        [
          1302.9,
          309.14
        ],
        [
          1305.3,
          307.67
        ],
        [
          1307.59,
          306.04
        ],
        [
          1309.76,
          304.26
        ],
        [
          1311.81,
          302.34
        ],
        [
          1313.72,
          300.28
        ],
        [
          1315.5,
          298.09
        ],
        [
          1317.12,
          295.78
        ],
        [
          1318.59,
          293.35
        ],
        [
          1319.9,
          290.81
        ],
        [
          1321.03,
          288.19
        ],
        [
          1321.97,
          285.51
        ],
        [
          1322.73,
          282.78
        ],
        [
          1323.29,
          280.02
        ],
        [
          1323.66,
          277.24
        ],
        [
          1323.85,
          274.44
        ],
        [
          1323.84,
          271.63
        ],
        [
          1323.64,
          268.82
        ],
        [
          1323.25,
          266.03
        ],
        [
          1322.67,
          263.27
        ],
        [
          1321.9,
          260.53
        ],
        [
          1320.94,
          257.85
        ]
      ],
      "accepted": false,
      "installedRouteLF": null,
      "verticalDropLF": null,
      "conductorCount": null,
      "drawnConductorLF": null,
      "conduitLF": null
    }
  ]
}