C-8 - Final Site Plan Civil PDF page 8; issued 02/23/2024; 1" = 20 FT ยท PRINTED SCALE Sidewalk widths: 4 FT, 5 FT and 6 FT Drive aisles: 20 FT and 24 FT Parking module: 9 FT x 20 FT typical Pool: 600 SF printed PROGRAM: 131-room civil label conflicts with the building takeoff - Do not normalize the civil 131-room label to the 85-room architectural count or 107-room mechanical schedule. SITE QUANTITIES: Parking and site-program totals are explicit - Carry 106 spaces, two accessible spaces, one bike rack, two EV charging points, a 600-SF pool and an outdoor lounge with two fire pits. PAVING / ACCESS: Widths and traffic paths are source-linked - Four-, five- and six-foot sidewalks plus 20- and 24-foot drive aisles are printed. Three vehicle paths are traced at scale. FUTURE RESTAURANT: Future building scope needs bid-boundary confirmation - The 4,000-SF restaurant and its utility/site support are shown on the civil plan. Confirm whether they are base, future or alternate scope. CIV-ADDR: Project address requires reconciliation - The civil set identifies 308 8th Street West. The architectural/MEP takeoff set identifies 716 3rd Avenue Drive West. Confirm the governing parcel and address before bid documents and RFIs are issued. CIV-ROOMS: Civil hotel program conflicts with architectural takeoff - C-8 through C-10 label a 131-room hotel. The architectural takeoff verifies 85 guestrooms, while the mechanical schedules reference 107. Preserve all three values until the design team identifies the governing program. C8-03: Future restaurant bid boundary is unclear - C-8 plots a future 4,000-SF restaurant, sidewalks, parking and connections without defining the construction package boundary. C8-04: Site areas are reconciled on C-9 - C-8 does not print paving/sidewalk area totals. Use C-9 impervious summary for printed SF and the saved C-8 paths for visible travel geometry. C8-05: Wheel-stop quantity requires symbol-by-symbol verification - Wheel stops are labeled TYP, but C-8 does not print an installed total. No wheel-stop count is inferred from parking spaces alone.