  "schemaVersion": "1.0",
  "sheet": {
    "number": "C-8",
    "title": "Final Site Plan",
    "civilPdfPage": 8,
    "issueDate": "2024-02-23",
    "addressPrinted": "308 8th Street West, City of Bradenton, Florida",
    "scale": "1\" = 20 FT · PRINTED SCALE"
  },
  "coordinateSpace": {
    "width": 1920,
    "height": 1280
  },
  "groups": [
    {
      "id": "parking-groups",
      "label": "Parking-count bubbles",
      "count": 13,
      "unit": "REF",
      "color": "#299bba",
      "basis": "SHOWN / SOURCE-LINKED",
      "status": "PLAN"
    },
    {
      "id": "ev",
      "label": "Double EV charging points",
      "count": 2,
      "unit": "EA",
      "color": "#d66a35",
      "basis": "SHOWN / SOURCE-LINKED",
      "status": "PLAN"
    },
    {
      "id": "bike",
      "label": "Bike rack",
      "count": 1,
      "unit": "EA",
      "color": "#876bd5",
      "basis": "SHOWN / SOURCE-LINKED",
      "status": "PLAN"
    }
  ],
  "measurements": [
    {
      "id": "c8-spine",
      "label": "North entrance / central drive spine",
      "unit": "LF",
      "line": [
        [
          807,
          180
        ],
        [
          805,
          430
        ],
        [
          807,
          650
        ],
        [
          720,
          710
        ]
      ],
      "color": "#299bba",
      "quantity": 215.9,
      "status": "MEASURED PATH - PRINTED SCALE",
      "basis": "Exact saved source polyline at 1 inch = 20 feet; curve endpoints are traced at visible centerline. Hidden depth, vertical, fittings and unshown continuation are excluded."
    },
    {
      "id": "c8-west",
      "label": "West parking drive path",
      "unit": "LF",
      "line": [
        [
          807,
          500
        ],
        [
          650,
          505
        ],
        [
          535,
          550
        ],
        [
          420,
          610
        ],
        [
          300,
          610
        ],
        [
          300,
          750
        ],
        [
          520,
          750
        ],
        [
          650,
          660
        ],
        [
          807,
          650
        ]
      ],
      "color": "#d66a35",
      "quantity": 452.1,
      "status": "MEASURED PATH - PRINTED SCALE",
      "basis": "Exact saved source polyline at 1 inch = 20 feet; curve endpoints are traced at visible centerline. Hidden depth, vertical, fittings and unshown continuation are excluded."
    },
    {
      "id": "c8-east",
      "label": "East parking drive loop",
      "unit": "LF",
      "line": [
        [
          900,
          500
        ],
        [
          1120,
          500
        ],
        [
          1360,
          520
        ],
        [
          1425,
          610
        ],
        [
          1425,
          750
        ],
        [
          1320,
          780
        ],
        [
          1150,
          745
        ],
        [
          1000,
          680
        ],
        [
          990,
          590
        ],
        [
          1120,
          560
        ],
        [
          1300,
          590
        ],
        [
          1425,
          610
        ]
      ],
      "color": "#876bd5",
      "quantity": 634.2,
      "status": "MEASURED PATH - PRINTED SCALE",
      "basis": "Exact saved source polyline at 1 inch = 20 feet; curve endpoints are traced at visible centerline. Hidden depth, vertical, fittings and unshown continuation are excluded."
    }
  ],
  "printedDimensions": [
    "Sidewalk widths: 4 FT, 5 FT and 6 FT",
    "Drive aisles: 20 FT and 24 FT",
    "Parking module: 9 FT x 20 FT typical",
    "Pool: 600 SF printed"
  ],
  "issues": [
    {
      "id": "CIV-ADDR",
      "title": "Project address requires reconciliation",
      "text": "The civil set identifies 308 8th Street West. The architectural/MEP takeoff set identifies 716 3rd Avenue Drive West. Confirm the governing parcel and address before bid documents and RFIs are issued."
    },
    {
      "id": "CIV-ROOMS",
      "title": "Civil hotel program conflicts with architectural takeoff",
      "text": "C-8 through C-10 label a 131-room hotel. The architectural takeoff verifies 85 guestrooms, while the mechanical schedules reference 107. Preserve all three values until the design team identifies the governing program."
    },
    {
      "id": "C8-03",
      "title": "Future restaurant bid boundary is unclear",
      "text": "C-8 plots a future 4,000-SF restaurant, sidewalks, parking and connections without defining the construction package boundary."
    },
    {
      "id": "C8-04",
      "title": "Site areas are reconciled on C-9",
      "text": "C-8 does not print paving/sidewalk area totals. Use C-9 impervious summary for printed SF and the saved C-8 paths for visible travel geometry."
    },
    {
      "id": "C8-05",
      "title": "Wheel-stop quantity requires symbol-by-symbol verification",
      "text": "Wheel stops are labeled TYP, but C-8 does not print an installed total. No wheel-stop count is inferred from parking spaces alone."
    }
  ]
}