  "schemaVersion": "1.0",
  "sheet": {
    "number": "C-7",
    "title": "Erosion & Sediment Control Details 2",
    "civilPdfPage": 7,
    "issueDate": "2024-02-23",
    "addressPrinted": "308 8th Street West, City of Bradenton, Florida",
    "scale": "NTS"
  },
  "coordinateSpace": {
    "width": 1920,
    "height": 1280
  },
  "groups": [
    {
      "id": "tree-barriers",
      "label": "Tree-barricade configurations",
      "count": 2,
      "unit": "REF",
      "color": "#299bba",
      "basis": "SHOWN / SOURCE-LINKED",
      "status": "PLAN"
    }
  ],
  "measurements": [],
  "printedDimensions": [
    "Upright: minimum 2 x 2 lumber",
    "Horizontal: minimum 1 x 4 lumber",
    "Post: at least 4 FT long",
    "Post embedment: minimum 1 FT",
    "Post above grade: minimum 3 FT",
    "Barrier location: entire drip line"
  ],
  "issues": [
    {
      "id": "CIV-ADDR",
      "title": "Project address requires reconciliation",
      "text": "The civil set identifies 308 8th Street West. The architectural/MEP takeoff set identifies 716 3rd Avenue Drive West. Confirm the governing parcel and address before bid documents and RFIs are issued."
    },
    {
      "id": "C7-02",
      "title": "Tree quantity is not plotted on C-7",
      "text": "This NTS detail does not identify which trees remain or the number of barricades; reconcile with landscape/tree-removal plans."
    },
    {
      "id": "C7-03",
      "title": "Sheet-total conflict",
      "text": "The title block prints Sheet 7 of 21, while the cover index identifies a 20-sheet civil set."
    },
    {
      "id": "C7-04",
      "title": "Code reference needs edition confirmation",
      "text": "The barricade note cites code section 2.2.3.2.H; confirm current City requirements."
    },
    {
      "id": "C7-05",
      "title": "Alternative barrier acceptance is discretionary",
      "text": "Alternative barriers may be accepted at the sole discretion of the City; do not price an unapproved substitution as base scope."
    }
  ]
}