  "schemaVersion": "1.0",
  "sheet": {
    "number": "C-3",
    "title": "Existing Conditions Plan",
    "civilPdfPage": 3,
    "sourcePdf": "BRADENTON HOTEL AND RESTAURANT Civil Set.pdf",
    "issueDate": "2024-02-23",
    "addressPrinted": "308 8th Street West, City of Bradenton, Florida",
    "scale": "1\" = 20' · PRINTED SCALE ONLY"
  },
  "coordinateSpace": {
    "width": 1920,
    "height": 1280
  },
  "groups": [
    {
      "id": "spt",
      "label": "SPT boring / hand cone sounding",
      "count": 1,
      "unit": "EA",
      "color": "#299bba",
      "basis": "SHOWN / SOURCE-LINKED",
      "status": "PLAN"
    },
    {
      "id": "infiltration",
      "label": "Double-ring infiltration / hand auger",
      "count": 1,
      "unit": "EA",
      "color": "#d66a35",
      "basis": "SHOWN / SOURCE-LINKED",
      "status": "PLAN"
    },
    {
      "id": "hand-auger",
      "label": "Hand auger / hand cone sounding",
      "count": 1,
      "unit": "EA",
      "color": "#876bd5",
      "basis": "SHOWN / SOURCE-LINKED",
      "status": "PLAN"
    }
  ],
  "regions": {
    "plan": [
      80,
      25,
      1660,
      1230
    ],
    "utility-core": [
      500,
      250,
      480,
      800
    ],
    "legend": [
      1470,
      30,
      270,
      245
    ],
    "title-block": [
      1735,
      25,
      165,
      1230
    ]
  },
  "requirements": [
    [
      "critical",
      "SURVEY / RFI",
      "Existing information is survey evidence, not proposed scope",
      "All visible utilities, structures, grades, roads, trees and property lines are retained as reference. Field verification remains required.",
      "plan"
    ],
    [
      "cost",
      "UTILITIES",
      "Existing wet and dry utilities cross the site",
      "Callouts identify water, sanitary, drainage, power, overhead wire and telecommunications infrastructure. Protect, remove or relocate only where later sheets direct.",
      "utility-core"
    ],
    [
      "critical",
      "TREE REMOVAL",
      "Tree scope is delegated to landscape plans",
      "C-3 Specification 1 says to see tree removal and landscape plans for trees; do not derive a tree-removal quantity from the aerial background.",
      "legend"
    ]
  ],
  "issues": [
    {
      "id": "CIV-ADDR",
      "title": "Project address requires reconciliation",
      "text": "This civil set identifies 308 8th Street West. The architectural/MEP takeoff set identifies 716 3rd Avenue Drive West. The layouts appear to describe the same development, but the governing parcel/address has not been confirmed."
    },
    {
      "id": "C3-02",
      "title": "Utility locations are existing-condition references",
      "text": "The sheet shows approximate/record and surveyed features. Confirm field locations and elevations before demolition or utility work."
    },
    {
      "id": "C3-03",
      "title": "Tree quantities cannot be taken from the aerial",
      "text": "Tree removal is expressly referred to separate landscape/tree-removal plans."
    },
    {
      "id": "C3-04",
      "title": "No proposed installation quantities on C-3",
      "text": "This is an existing-conditions sheet. Existing lines and objects are not converted into new-work quantities."
    },
    {
      "id": "C3-05",
      "title": "Dense spot-elevation field is reference-only",
      "text": "Survey spot elevations remain visible in the source but are not summed or treated as grading quantities."
    }
  ],
  "measurementPolicy": "No scaled quantity is reported without a printed dimension chain and independent calibration. Graphic-only geometry remains null.",
  "completeSheetGate": "PASS"
}