  "schemaVersion": "1.0",
  "sheet": {
    "number": "C-2",
    "title": "General Notes",
    "civilPdfPage": 2,
    "sourcePdf": "BRADENTON HOTEL AND RESTAURANT Civil Set.pdf",
    "issueDate": "2024-02-23",
    "addressPrinted": "308 8th Street West, City of Bradenton, Florida",
    "scale": "NTS"
  },
  "coordinateSpace": {
    "width": 1920,
    "height": 1280
  },
  "groups": [],
  "regions": {
    "general": [
      110,
      40,
      350,
      760
    ],
    "utilities": [
      110,
      815,
      350,
      340
    ],
    "layout": [
      555,
      300,
      330,
      250
    ],
    "erosion": [
      555,
      550,
      330,
      310
    ],
    "grading": [
      915,
      40,
      350,
      1020
    ],
    "trench": [
      1290,
      40,
      400,
      660
    ],
    "inspection-form": [
      1270,
      735,
      440,
      420
    ],
    "title-block": [
      1735,
      25,
      165,
      1230
    ]
  },
  "requirements": [
    [
      "critical",
      "UTILITIES / RFI",
      "Existing utility information must be independently verified",
      "Locations, sizes and types are approximate; contractor must investigate conflicts, coordinate owners and use subsurface utility notification before excavation.",
      "utilities"
    ],
    [
      "cost",
      "EARTHWORK",
      "Compaction and testing are contractor scope",
      "Work includes geotechnical testing, 12-inch maximum lifts, proof rolling and corrective earthwork where required.",
      "grading"
    ],
    [
      "critical",
      "EROSION",
      "Inspection and maintenance are continuous obligations",
      "Controls must be maintained, repaired and documented; the inspection form requires at least weekly review and within 24 hours after a storm event of 0.50 inches or greater.",
      "erosion"
    ],
    [
      "cost",
      "RESTORATION",
      "Disturbed improvements must be restored",
      "Roads, walks, pavement, landscaping, utilities and adjacent work damaged by construction are contractor responsibility.",
      "general"
    ],
    [
      "critical",
      "TRENCH / SAFETY",
      "Utility crossings have prescribed clearances",
      "The trench notes require minimum vertical/horizontal separations and flowable-fill or concrete encasement where clearances cannot be met.",
      "trench"
    ]
  ],
  "issues": [
    {
      "id": "CIV-ADDR",
      "title": "Project address requires reconciliation",
      "text": "This civil set identifies 308 8th Street West. The architectural/MEP takeoff set identifies 716 3rd Avenue Drive West. The layouts appear to describe the same development, but the governing parcel/address has not been confirmed."
    },
    {
      "id": "C2-02",
      "title": "Notes define scope but not quantities",
      "text": "C-2 is NTS and contains requirements only. No installed material quantities, lengths, areas or volumes are inferred from generic notes."
    },
    {
      "id": "C2-03",
      "title": "Stormwater inspection form is blank",
      "text": "Project name, operator, permit number, inspection entries and certifications must be completed during construction."
    },
    {
      "id": "C2-04",
      "title": "Utility ownership and conflicts remain open",
      "text": "The sheet disclaims completeness of existing utilities and requires field verification and coordination before work."
    },
    {
      "id": "C2-05",
      "title": "Geotechnical acceptance chain is incomplete",
      "text": "The notes require proof rolling, compaction testing and soil-consultant review; the governing geotechnical report is not linked on C-2."
    }
  ],
  "measurementPolicy": "No scaled quantity is reported without a printed dimension chain and independent calibration. Graphic-only geometry remains null.",
  "completeSheetGate": "PASS"
}