  "schemaVersion": "1.0",
  "sheet": {
    "number": "C-16",
    "title": "Site Details 2",
    "civilPdfPage": 15,
    "issueDate": "2024-02-23",
    "addressPrinted": "308 8th Street West, City of Bradenton, Florida",
    "scale": "NTS"
  },
  "coordinateSpace": {
    "width": 1920,
    "height": 1280
  },
  "groups": [
    {
      "id": "details",
      "label": "Major site details",
      "count": 3,
      "unit": "REF",
      "color": "#299bba",
      "basis": "SHOWN / SOURCE-LINKED",
      "status": "PLAN"
    }
  ],
  "sourceMarkers": [
    {
      "id": "details-01",
      "type": "details",
      "x": 390,
      "y": 285,
      "labelX": 398,
      "labelY": 278,
      "sourceNote": "Major site details 1",
      "scopeKey": "C-16/details/1",
      "reconciliation": "SHOWN"
    },
    {
      "id": "details-02",
      "type": "details",
      "x": 370,
      "y": 660,
      "labelX": 378,
      "labelY": 653,
      "sourceNote": "Major site details 2",
      "scopeKey": "C-16/details/2",
      "reconciliation": "SHOWN"
    },
    {
      "id": "details-03",
      "type": "details",
      "x": 360,
      "y": 990,
      "labelX": 368,
      "labelY": 983,
      "sourceNote": "Major site details 3",
      "scopeKey": "C-16/details/3",
      "reconciliation": "SHOWN"
    }
  ],
  "measurements": [],
  "printedDimensions": [
    "Concrete walk: 4 IN typical; 6 IN where subject to vehicular traffic",
    "Crushed-concrete base: minimum 8 IN, LBR-100, 98% AASHTO T-180",
    "Compacted subgrade: minimum 12 IN, LBR-40, 98% AASHTO T-180",
    "Base under curb: minimum 6 IN and 12 IN beyond back of curb",
    "STOP sign: 30 IN x 30 IN, R1-1",
    "Dumpster pad: minimum 10 FT x 10 FT x 6 IN",
    "Dumpster fence: 6 FT opaque",
    "Dumpster setback: 10 FT minimum unless approved sprinkler protection is provided"
  ],
  "requirements": [
    [
      "cost",
      "CURB / PAVING",
      "Type D curb section defines the pavement build-up",
      "The section includes concrete walk, curb and gutter, asphalt surface, tack/prime coat, 8-inch crushed-concrete base and 12-inch compacted subgrade.",
      "curb"
    ],
    [
      "critical",
      "DUMPSTER PAD",
      "Food-service pad requires drainage and grease control",
      "The minimum 10-by-10-foot pad is 6 inches thick, 3,000 PSI concrete with reinforcement, a sump drain and grease trap, plus an opaque 6-foot fence.",
      "dumpster"
    ],
    [
      "critical",
      "FIRE SEPARATION",
      "Dumpster proximity can trigger sprinkler scope",
      "Keep the dumpster at least 10 feet from a building. If closer, a fire-sprinkler suppression system requires Fire Marshal approval.",
      "dumpster"
    ],
    [
      "cost",
      "SIGN",
      "STOP sign geometry is printed",
      "The NTS site-sign detail shows one 30-by-30-inch R1-1 sign definition; installed count comes from C-13.",
      "sign"
    ]
  ],
  "issues": [
    {
      "id": "CIV-ADDR",
      "title": "Project address requires reconciliation",
      "text": "The civil set identifies 308 8th Street West. The architectural/MEP takeoff set identifies 716 3rd Avenue Drive West. Confirm the governing parcel and address before bid documents and RFIs are issued."
    },
    {
      "id": "CIV-NUMBERING",
      "title": "C-14 is missing from the issued PDF",
      "text": "The source PDF proceeds from C-13 directly to C-15. The cover index and title-block totals are inconsistent; obtain the missing C-14 sheet or written confirmation that it was intentionally omitted."
    },
    {
      "id": "C16-03",
      "title": "Dumpster pad location is not identified on this detail",
      "text": "C-16 defines the assembly but does not establish whether the hotel or future restaurant carries the pad, drain, grease trap and enclosure."
    },
    {
      "id": "C16-04",
      "title": "Drain and grease-trap connection is unresolved",
      "text": "The detail requires a sump drain and grease trap for food and beverage service but provides no pipe size, route, invert or receiving system."
    },
    {
      "id": "C16-05",
      "title": "Detail count is not installed quantity",
      "text": "The three NTS details are definitions. Curb LF, sign EA and dumpster-pad EA must be reconciled to the plan and project scope."
    }
  ]
}