  "schemaVersion": "1.0",
  "sheet": {
    "number": "C-15",
    "title": "Site Details 1",
    "civilPdfPage": 14,
    "issueDate": "2024-02-23",
    "addressPrinted": "308 8th Street West, City of Bradenton, Florida",
    "scale": "NTS"
  },
  "coordinateSpace": {
    "width": 1920,
    "height": 1280
  },
  "groups": [
    {
      "id": "details",
      "label": "Major site details",
      "count": 5,
      "unit": "REF",
      "color": "#299bba",
      "basis": "SHOWN / SOURCE-LINKED",
      "status": "PLAN"
    }
  ],
  "sourceMarkers": [
    {
      "id": "details-01",
      "type": "details",
      "x": 925,
      "y": 310,
      "labelX": 933,
      "labelY": 303,
      "sourceNote": "Major site details 1",
      "scopeKey": "C-15/details/1",
      "reconciliation": "SHOWN"
    },
    {
      "id": "details-02",
      "type": "details",
      "x": 1420,
      "y": 330,
      "labelX": 1428,
      "labelY": 323,
      "sourceNote": "Major site details 2",
      "scopeKey": "C-15/details/2",
      "reconciliation": "SHOWN"
    },
    {
      "id": "details-03",
      "type": "details",
      "x": 380,
      "y": 935,
      "labelX": 388,
      "labelY": 928,
      "sourceNote": "Major site details 3",
      "scopeKey": "C-15/details/3",
      "reconciliation": "SHOWN"
    },
    {
      "id": "details-04",
      "type": "details",
      "x": 970,
      "y": 930,
      "labelX": 978,
      "labelY": 923,
      "sourceNote": "Major site details 4",
      "scopeKey": "C-15/details/4",
      "reconciliation": "SHOWN"
    },
    {
      "id": "details-05",
      "type": "details",
      "x": 1490,
      "y": 930,
      "labelX": 1498,
      "labelY": 923,
      "sourceNote": "Major site details 5",
      "scopeKey": "C-15/details/5",
      "reconciliation": "SHOWN"
    }
  ],
  "measurements": [],
  "printedDimensions": [
    "Double accessible stall: 29 FT overall (12 FT + 5 FT + 12 FT)",
    "Accessible stall depth: 18 FT",
    "Access aisle: 5 FT wide",
    "Traffic-blue accessible stripe: 6 IN wide",
    "Sidewalk: 3,000 PSI concrete, 4 IN thick",
    "Driveway sidewalk crossing: 6 IN thick with 6x6/10x10 welded wire mesh",
    "Expansion joints: maximum 120 FT spacing",
    "Detectable warning depth: 2 FT typical",
    "Concrete wheel stop: 6 FT long; two No. 5 rebars"
  ],
  "requirements": [
    [
      "critical",
      "ACCESSIBILITY",
      "Accessible sign, stall and detectable-warning details are separate",
      "Carry the sign assembly, blue/white striping, double-stall geometry, curb ramps and full-width detectable warnings as one coordinated accessible-parking system.",
      "accessibility"
    ],
    [
      "cost",
      "SIDEWALK",
      "Sidewalk construction has material and joint requirements",
      "Concrete is 3,000 PSI minimum at 28 days with fiber mesh; driveways are 6 inches thick with 6x6/10x10 welded wire mesh; expansion joints cannot exceed 120 feet.",
      "sidewalk"
    ],
    [
      "cost",
      "PAVING",
      "Fifteen general notes govern the pavement system",
      "Notes cover asphalt, base, subgrade, drainage, soil cement, shell, gutters, topsoil, sod, visibility, ramps, traffic control, prime/tack coat and lift sequencing.",
      "general"
    ],
    [
      "critical",
      "DETECTABLE WARNING",
      "Contrast and geometry are mandatory",
      "Warnings extend the full width and depth of the curb ramp and use truncated domes with printed spacing and contrast criteria.",
      "warnings"
    ]
  ],
  "issues": [
    {
      "id": "CIV-ADDR",
      "title": "Project address requires reconciliation",
      "text": "The civil set identifies 308 8th Street West. The architectural/MEP takeoff set identifies 716 3rd Avenue Drive West. Confirm the governing parcel and address before bid documents and RFIs are issued."
    },
    {
      "id": "CIV-NUMBERING",
      "title": "C-14 is missing from the issued PDF",
      "text": "The source PDF proceeds from C-13 directly to C-15. The cover index and title-block totals are inconsistent; obtain the missing C-14 sheet or written confirmation that it was intentionally omitted."
    },
    {
      "id": "C15-03",
      "title": "Installed quantities must come from plan sheets",
      "text": "C-15 is NTS. Detail references do not create project quantities for signs, stalls, ramps, wheel stops, sidewalk or joints."
    },
    {
      "id": "C15-04",
      "title": "Legacy standards require edition confirmation",
      "text": "General notes cite FDOT 2000 standards and City details dated 2013/2016. Confirm current adopted specifications before bidding."
    },
    {
      "id": "C15-05",
      "title": "Accessible marking conflict carries from C-13",
      "text": "C-13 calls out 18-inch stop bars while its legend shows 24-inch striping. C-15 says all pavement markings are thermoplastic but does not resolve the width."
    }
  ]
}