  "schemaVersion": "1.0",
  "sheet": {
    "number": "C-12",
    "title": "Cross Sections",
    "civilPdfPage": 12,
    "issueDate": "2024-02-23",
    "addressPrinted": "308 8th Street West, City of Bradenton, Florida",
    "scale": "1\" = 5 FT · PRINTED SCALE"
  },
  "coordinateSpace": {
    "width": 1920,
    "height": 1280
  },
  "groups": [
    {
      "id": "sections",
      "label": "Site cross sections A through E",
      "count": 5,
      "unit": "REF",
      "color": "#299bba",
      "basis": "SHOWN / SOURCE-LINKED",
      "status": "PLAN"
    }
  ],
  "sourceMarkers": [
    {
      "id": "sections-01",
      "type": "sections",
      "x": 915,
      "y": 195,
      "labelX": 923,
      "labelY": 188,
      "sourceNote": "Site cross sections A through E 1",
      "scopeKey": "C-12/sections/1",
      "reconciliation": "SHOWN"
    },
    {
      "id": "sections-02",
      "type": "sections",
      "x": 915,
      "y": 430,
      "labelX": 923,
      "labelY": 423,
      "sourceNote": "Site cross sections A through E 2",
      "scopeKey": "C-12/sections/2",
      "reconciliation": "SHOWN"
    },
    {
      "id": "sections-03",
      "type": "sections",
      "x": 915,
      "y": 665,
      "labelX": 923,
      "labelY": 658,
      "sourceNote": "Site cross sections A through E 3",
      "scopeKey": "C-12/sections/3",
      "reconciliation": "SHOWN"
    },
    {
      "id": "sections-04",
      "type": "sections",
      "x": 915,
      "y": 895,
      "labelX": 923,
      "labelY": 888,
      "sourceNote": "Site cross sections A through E 4",
      "scopeKey": "C-12/sections/4",
      "reconciliation": "SHOWN"
    },
    {
      "id": "sections-05",
      "type": "sections",
      "x": 915,
      "y": 1120,
      "labelX": 923,
      "labelY": 1113,
      "sourceNote": "Site cross sections A through E 5",
      "scopeKey": "C-12/sections/5",
      "reconciliation": "SHOWN"
    }
  ],
  "measurements": [],
  "printedDimensions": [
    "Section A: 5 FT sidewalk; two 12.5 FT drive lanes; island varies",
    "Sections B/D: 20 FT parking modules; paired 12 FT drive lanes; 5 FT island; 15 FT drive lane; 7 FT sidewalk",
    "Sections C/E: 4.7 FT grass; 6 FT sidewalk; 4 FT grass; paired 12 FT drive lanes; 20 FT parking; 5 FT sidewalk; 21.8 FT grass",
    "Hotel finish floor elevation: 12.30",
    "Restaurant finish floor elevation: 13.15",
    "Printed slopes retained: 0.1% through 6.0%, 1:5.5 and 1:12"
  ],
  "requirements": [
    [
      "critical",
      "ELEVATIONS",
      "Building pads differ by 0.85 foot",
      "The proposed hotel finish floor is 12.30 and the proposed restaurant finish floor is 13.15. Coordinate accessible routes, thresholds, drainage and utility entries.",
      "sections"
    ],
    [
      "cost",
      "PAVING PROFILE",
      "Five full site sections define the grading build-up",
      "Sections A through E retain every printed parking, drive-lane, island, sidewalk, grass and slope dimension.",
      "sections"
    ],
    [
      "critical",
      "SLOPES",
      "Cross slopes vary across the site",
      "Printed slopes include 0.1%, 0.2%, 0.3%, 0.4%, 0.5%, 0.8%, 1.0%, 1.3%, 1.5%, 2.0%, 2.1%, 3.7%, 6.0%, 1:5.5 and 1:12. Confirm accessible-route compliance at transitions.",
      "sections"
    ]
  ],
  "issues": [
    {
      "id": "CIV-ADDR",
      "title": "Project address requires reconciliation",
      "text": "The civil set identifies 308 8th Street West. The architectural/MEP takeoff set identifies 716 3rd Avenue Drive West. Confirm the governing parcel and address before bid documents and RFIs are issued."
    },
    {
      "id": "C12-02",
      "title": "Cross-section widths are not site-wide quantities",
      "text": "Printed widths define five section cuts; they are not multiplied into paving, curb or sidewalk quantities without the plan extents."
    },
    {
      "id": "C12-03",
      "title": "Restaurant finish floor is future-scope dependent",
      "text": "The 13.15 restaurant finish-floor elevation must remain coordinated even if the restaurant is excluded or deferred."
    },
    {
      "id": "C12-04",
      "title": "Accessible-route chain is not identified",
      "text": "The sections show multiple slopes but do not label one continuous accessible route from public way and accessible parking to the hotel entrance."
    }
  ]
}