C-11 - Easements Plan Civil PDF page 11; issued 02/23/2024; 1" = 20 FT ยท PRINTED SCALE Water easement: 20 FT wide (printed) Graphic scale: 0 / 20 / 40 FT Proposed pedestrian-easement centerline: 186.4 LF visible plan path EASEMENT LIMITS: Do not build from graphic limits alone - The sheet distinguishes a 20-foot-wide water easement and one proposed pedestrian easement. Obtain executed legal descriptions and record status before layout. PEDESTRIAN EASEMENT: The visible centerline is traced at scale - The proposed pedestrian easement bends south through the site and west near the future restaurant; only the visible plan centerline is measured. WATER EASEMENT: Utility access affects permanent improvements - Coordinate paving, landscape, foundations, signs and future restaurant work within the 20-foot water-easement corridor. CIV-ADDR: Project address requires reconciliation - The civil set identifies 308 8th Street West. The architectural/MEP takeoff set identifies 716 3rd Avenue Drive West. Confirm the governing parcel and address before bid documents and RFIs are issued. C11-02: Legal descriptions are not included - C-11 is a graphic easement exhibit. Bearings, metes-and-bounds descriptions, recording data and effective status are not provided. C11-03: Existing versus proposed status needs confirmation - The pedestrian easement is labeled proposed. Confirm whether it must be recorded before permit, construction or certificate of occupancy. C11-04: Future restaurant overlap requires coordination - The easement geometry passes beside the future restaurant parcel and service area; verify encroachment limits and access rights.