C-10 - Utility Plan Civil PDF page 10; issued 02/23/2024; 1" = 20 FT · PRINTED SCALE Fire line: 6 IN DR14 Domestic water: 6 IN DR18 Domestic water branch: 4 IN DR18 Force main: 2 IN Existing sanitary manhole rim: 13.16 Existing sanitary manhole NW invert: 10.87 Existing sanitary manhole S invert: 10.75 Grinder pump rim: 12.50 Grinder pump invert: 7.60 WATER: Three sized water paths are traced - The 6-inch DR14 fire line, 6-inch DR18 water main and 4-inch DR18 water main are saved as separate scaled paths. ACCESSORIES: Carry every printed water accessory - Callouts include three 6 x 6 tees, one 6-inch gate valve, one 6-inch backflow assembly, one 6 x 4 reducer, one 4-inch 90-degree bend, one 4-inch backflow assembly, one 3-inch water meter and one fire hydrant assembly. FORCE MAIN: Two-inch force main is traced between visible endpoints - The route connects the existing manhole side to the proposed grinder-pump station. Inverts remain as printed; building-internal connections are by others. BY OTHERS: Utility connections to buildings are excluded - C-10 explicitly labels utility connections to the buildings as BY OTHERS. Confirm the exact exterior/interior handoff. CIV-ADDR: Project address requires reconciliation - The civil set identifies 308 8th Street West. The architectural/MEP takeoff set identifies 716 3rd Avenue Drive West. Confirm the governing parcel and address before bid documents and RFIs are issued. CIV-ROOMS: Civil hotel program conflicts with architectural takeoff - C-8 through C-10 label a 131-room hotel. The architectural takeoff verifies 85 guestrooms, while the mechanical schedules reference 107. Preserve all three values until the design team identifies the governing program. C10-03: Building utility handoff is open - “Utility connections to building by others” does not identify the trade, exact termination, penetration, valve or responsibility limit. C10-04: Existing-main connection requires field verification - Contractor must connect to the existing 6-inch water main. Confirm location, elevation, shutdown, tapping method and City requirements. C10-05: Title-block sequence is offset - C-10 prints 11 of 20 in its title block although the cover index identifies it as C-10. C10-06: Future restaurant scope is unresolved - The restaurant is shown with utility support but no clear base/future/alternate construction boundary.