  "sheet": "A7.10",
  "coordinateSpace": {
    "width": 1920,
    "height": 1280
  },
  "calibration": {
    "pixelsPerFoot": 26.666666666666668,
    "printedScale": "1/2 inch = 1 foot",
    "checks": [
      {
        "view": "Printed half-inch scale",
        "pixelsPerFoot": 26.666666666666668
      },
      {
        "view": "Desk overall 11ft6",
        "sourcePixels": 308,
        "referenceFeet": 11.5
      },
      {
        "view": "North elevation body 10ft8-3/4",
        "sourcePixels": 286,
        "referenceFeet": 10.729166666666666
      }
    ]
  },
  "rows": [
    {
      "id": "dim-156",
      "label": "Printed dimension \u00b7 10 1/2\"",
      "quantity": 0.875,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          181.51774088541666,
          983.00537109375
        ],
        [
          184.37720404730902,
          983.00537109375
        ]
      ]
    },
    {
      "id": "dim-159",
      "label": "Printed dimension \u00b7 9\"",
      "quantity": 0.75,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          231.32940221715853,
          982.2307219328703
        ],
        [
          231.32940221715853,
          983.7800202546296
        ]
      ]
    },
    {
      "id": "dim-160",
      "label": "Printed dimension \u00b7 1'-10\"",
      "quantity": 1.8333333333333335,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          194.87729673032405,
          975.153175636574
        ],
        [
          197.20072428385416,
          975.153175636574
        ]
      ]
    },
    {
      "id": "dim-161",
      "label": "Printed dimension \u00b7 1 1/2\"",
      "quantity": 0.125,
      "unit": "LF",
      "color": "#398d79",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          220.83441840277777,
          987.4541558159722
        ],
        [
          223.18678114149304,
          987.4541558159722
        ]
      ]
    },
    {
      "id": "dim-162",
      "label": "Printed dimension \u00b7 1'-6\"",
      "quantity": 1.5,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          192.06913700810185,
          1060.3114149305557
        ],
        [
          193.88538501880785,
          1060.3114149305557
        ]
      ]
    },
    {
      "id": "dim-163",
      "label": "Printed dimension \u00b7 3\"",
      "quantity": 0.25,
      "unit": "LF",
      "color": "#b06bad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          238.14164903428818,
          986.6795066550925
        ],
        [
          238.14164903428818,
          988.2288049768517
        ]
      ]
    },
    {
      "id": "dim-164",
      "label": "Printed dimension \u00b7 4\"",
      "quantity": 0.3333333333333333,
      "unit": "LF",
      "color": "#cf4f62",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          167.24556251808448,
          1017.5416847511574
        ],
        [
          168.79486083984375,
          1017.5416847511574
        ]
      ]
    },
    {
      "id": "dim-165",
      "label": "Printed dimension \u00b7 1 1/2\"",
      "quantity": 0.125,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          166.78015814887152,
          1005.3360098379629
        ],
        [
          166.78015814887152,
          1007.6882595486111
        ]
      ]
    },
    {
      "id": "dim-166",
      "label": "Printed dimension \u00b7 6\"",
      "quantity": 0.5,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          167.24556251808448,
          999.833351417824
        ],
        [
          168.79486083984375,
          999.833351417824
        ]
      ]
    },
    {
      "id": "dim-167",
      "label": "Printed dimension \u00b7 3/4\"",
      "quantity": 0.0625,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          166.78015814887152,
          1035.526710792824
        ],
        [
          166.78015814887152,
          1037.1182364004628
        ]
      ]
    },
    {
      "id": "dim-168",
      "label": "Printed dimension \u00b7 4\"",
      "quantity": 0.3333333333333333,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          167.24556251808448,
          1026.6478587962963
        ],
        [
          168.79486083984375,
          1026.6478587962963
        ]
      ]
    },
    {
      "id": "dim-169",
      "label": "Printed dimension \u00b7 3\"",
      "quantity": 0.25,
      "unit": "LF",
      "color": "#398d79",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          167.24556251808448,
          1072.5263581452546
        ],
        [
          168.79486083984375,
          1072.5263581452546
        ]
      ]
    },
    {
      "id": "dim-170",
      "label": "Printed dimension \u00b7 2 1/4\"",
      "quantity": 0.1875,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          168.02021167896413,
          1078.0274341724537
        ],
        [
          168.02021167896413,
          1080.3797743055554
        ]
      ]
    },
    {
      "id": "dim-171",
      "label": "Printed dimension \u00b7 4\"",
      "quantity": 0.3333333333333333,
      "unit": "LF",
      "color": "#b06bad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          167.24556251808448,
          1085.3167046440972
        ],
        [
          168.79486083984375,
          1085.3167046440972
        ]
      ]
    },
    {
      "id": "dim-172",
      "label": "Printed dimension \u00b7 4\"",
      "quantity": 0.3333333333333333,
      "unit": "LF",
      "color": "#cf4f62",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          239.4800708912037,
          1085.3167046440972
        ],
        [
          241.02939181857639,
          1085.3167046440972
        ]
      ]
    },
    {
      "id": "dim-173",
      "label": "Printed dimension \u00b7 2\"",
      "quantity": 0.16666666666666666,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          216.92450629340277,
          998.5646791811341
        ],
        [
          218.47382722077546,
          998.5646791811341
        ]
      ]
    },
    {
      "id": "dim-174",
      "label": "Printed dimension \u00b7 9\"",
      "quantity": 0.75,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          210.20192464192706,
          1024.172092013889
        ],
        [
          210.20192464192706,
          1025.721390335648
        ]
      ]
    },
    {
      "id": "dim-175",
      "label": "Printed dimension \u00b7 3'-0\"",
      "quantity": 3.0,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          160.81625479239005,
          1049.355197482639
        ],
        [
          160.81625479239005,
          1051.1713324652776
        ]
      ]
    },
    {
      "id": "dim-176",
      "label": "Printed dimension \u00b7 1'-11\"",
      "quantity": 1.9166666666666665,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          349.29475007233793,
          951.2439416956017
        ],
        [
          351.61817762586804,
          951.2439416956017
        ]
      ]
    },
    {
      "id": "dim-179",
      "label": "Printed dimension \u00b7 9\"",
      "quantity": 0.75,
      "unit": "LF",
      "color": "#398d79",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          384.63471589265043,
          950.4692925347222
        ],
        [
          384.63471589265043,
          952.0185908564814
        ]
      ]
    },
    {
      "id": "dim-180",
      "label": "Printed dimension \u00b7 1'-10\"",
      "quantity": 1.8333333333333335,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          348.1825538917824,
          943.3917462384259
        ],
        [
          350.5059814453125,
          943.3917462384259
        ]
      ]
    },
    {
      "id": "dim-181",
      "label": "Printed dimension \u00b7 1\"",
      "quantity": 0.08333333333333333,
      "unit": "LF",
      "color": "#b06bad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          375.7370447229456,
          954.918167679398
        ],
        [
          375.7370447229456,
          956.4674660011574
        ]
      ]
    },
    {
      "id": "dim-182",
      "label": "Printed dimension \u00b7 3\"",
      "quantity": 0.25,
      "unit": "LF",
      "color": "#cf4f62",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          391.4469627097801,
          954.918167679398
        ],
        [
          391.4469627097801,
          956.4674660011574
        ]
      ]
    },
    {
      "id": "dim-183",
      "label": "Printed dimension \u00b7 1\"",
      "quantity": 0.08333333333333333,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          320.5508987991898,
          1056.8919089988426
        ],
        [
          322.1002197265625,
          1056.8919089988426
        ]
      ]
    },
    {
      "id": "dim-184",
      "label": "Printed dimension \u00b7 4\"",
      "quantity": 0.3333333333333333,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          392.78537326388886,
          1053.555275245949
        ],
        [
          394.3346715856481,
          1053.555275245949
        ]
      ]
    },
    {
      "id": "dim-185",
      "label": "Printed dimension \u00b7 2\"",
      "quantity": 0.16666666666666666,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          370.22980866608793,
          966.8032497829861
        ],
        [
          371.7791295934606,
          966.8032497829861
        ]
      ]
    },
    {
      "id": "dim-186",
      "label": "Printed dimension \u00b7 1'-8\"",
      "quantity": 1.6666666666666665,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          347.59883174189815,
          1009.700611255787
        ],
        [
          349.41507975260413,
          1009.700611255787
        ]
      ]
    },
    {
      "id": "dim-187",
      "label": "Printed dimension \u00b7 3 3/4\"",
      "quantity": 0.3125,
      "unit": "LF",
      "color": "#398d79",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          321.32555926287614,
          1023.187843605324
        ],
        [
          321.32555926287614,
          1025.5401837384259
        ]
      ]
    },
    {
      "id": "dim-188",
      "label": "Printed dimension \u00b7 1\"",
      "quantity": 0.08333333333333333,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          320.5508987991898,
          1028.8086841724537
        ],
        [
          322.1002197265625,
          1028.8086841724537
        ]
      ]
    },
    {
      "id": "dim-189",
      "label": "Printed dimension \u00b7 3/4\"",
      "quantity": 0.0625,
      "unit": "LF",
      "color": "#b06bad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          319.3708066587095,
          1034.5008680555554
        ],
        [
          319.3708066587095,
          1036.092484085648
        ]
      ]
    },
    {
      "id": "dim-190",
      "label": "Printed dimension \u00b7 10\"",
      "quantity": 0.8333333333333334,
      "unit": "LF",
      "color": "#cf4f62",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          320.5508987991898,
          1042.986156322338
        ],
        [
          322.1002197265625,
          1042.986156322338
        ]
      ]
    },
    {
      "id": "dim-191",
      "label": "Printed dimension \u00b7 1 1/2\"",
      "quantity": 0.125,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          319.3708066587095,
          972.9849356192129
        ],
        [
          319.3708066587095,
          975.3371853298611
        ]
      ]
    },
    {
      "id": "dim-193",
      "label": "Printed dimension \u00b7 3'-0\"",
      "quantity": 3.0,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          309.4806699399595,
          1017.5937680844906
        ],
        [
          309.4806699399595,
          1019.4099030671296
        ]
      ]
    },
    {
      "id": "dim-194",
      "label": "Printed dimension \u00b7 2'-0\"",
      "quantity": 2.0,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          518.3188657407408,
          1040.447681568287
        ],
        [
          520.1351363570601,
          1040.447681568287
        ]
      ]
    },
    {
      "id": "dim-195",
      "label": "Printed dimension \u00b7 4\"",
      "quantity": 0.3333333333333333,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          544.5978913483796,
          1124.963695384838
        ],
        [
          546.1471896701388,
          1124.963695384838
        ]
      ]
    },
    {
      "id": "dim-196",
      "label": "Printed dimension \u00b7 2\"",
      "quantity": 0.16666666666666666,
      "unit": "LF",
      "color": "#398d79",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          547.7613208912037,
          1056.0069444444443
        ],
        [
          549.3106192129629,
          1056.0069444444443
        ]
      ]
    },
    {
      "id": "dim-197",
      "label": "Printed dimension \u00b7 4\"",
      "quantity": 0.3333333333333333,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          487.93429904513886,
          1061.6374602141204
        ],
        [
          489.4835973668981,
          1061.6374602141204
        ]
      ]
    },
    {
      "id": "dim-198",
      "label": "Printed dimension \u00b7 3/4\"",
      "quantity": 0.0625,
      "unit": "LF",
      "color": "#b06bad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          487.73053204571755,
          1079.0167462384259
        ],
        [
          487.73053204571755,
          1080.6083622685185
        ]
      ]
    },
    {
      "id": "dim-199",
      "label": "Printed dimension \u00b7 4\"",
      "quantity": 0.3333333333333333,
      "unit": "LF",
      "color": "#cf4f62",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          487.93429904513886,
          1070.7436342592591
        ],
        [
          489.4835973668981,
          1070.7436342592591
        ]
      ]
    },
    {
      "id": "dim-200",
      "label": "Printed dimension \u00b7 1 1/2\"",
      "quantity": 0.125,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          487.05417209201386,
          1049.3873878761574
        ],
        [
          487.05417209201386,
          1051.7397280092591
        ]
      ]
    },
    {
      "id": "dim-201",
      "label": "Printed dimension \u00b7 3\"",
      "quantity": 0.25,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          543.1204562717014,
          1064.515064380787
        ],
        [
          543.1204562717014,
          1066.0643627025463
        ]
      ]
    },
    {
      "id": "dim-202",
      "label": "Printed dimension \u00b7 2'-10\"",
      "quantity": 2.8333333333333335,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          462.6502369068287,
          1091.247829861111
        ],
        [
          462.6502369068287,
          1093.5712348090276
        ]
      ]
    },
    {
      "id": "dim-203",
      "label": "Printed dimension \u00b7 10 1/2\"",
      "quantity": 0.875,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          637.0197663483796,
          983.00537109375
        ],
        [
          639.8792408130787,
          983.00537109375
        ]
      ]
    },
    {
      "id": "dim-206",
      "label": "Printed dimension \u00b7 9\"",
      "quantity": 0.75,
      "unit": "LF",
      "color": "#398d79",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          686.8313485604745,
          982.2307219328703
        ],
        [
          686.8313485604745,
          983.7800202546296
        ]
      ]
    },
    {
      "id": "dim-207",
      "label": "Printed dimension \u00b7 1'-10\"",
      "quantity": 1.8333333333333335,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          650.3792317708333,
          975.153175636574
        ],
        [
          652.7025915075232,
          975.153175636574
        ]
      ]
    },
    {
      "id": "dim-208",
      "label": "Printed dimension \u00b7 1 1/2\"",
      "quantity": 0.125,
      "unit": "LF",
      "color": "#b06bad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          676.3363986545138,
          987.4541558159722
        ],
        [
          678.6887387876156,
          987.4541558159722
        ]
      ]
    },
    {
      "id": "dim-209",
      "label": "Printed dimension \u00b7 3\"",
      "quantity": 0.25,
      "unit": "LF",
      "color": "#cf4f62",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          693.6436179832176,
          986.6795066550925
        ],
        [
          693.6436179832176,
          988.2288049768517
        ]
      ]
    },
    {
      "id": "dim-210",
      "label": "Printed dimension \u00b7 4\"",
      "quantity": 0.3333333333333333,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          622.7475766782406,
          1017.5416847511574
        ],
        [
          624.296875,
          1017.5416847511574
        ]
      ]
    },
    {
      "id": "dim-211",
      "label": "Printed dimension \u00b7 1 1/2\"",
      "quantity": 0.125,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          619.1609700520833,
          1015.0878906249999
        ],
        [
          619.1609700520833,
          1017.440140335648
        ]
      ]
    },
    {
      "id": "dim-212",
      "label": "Printed dimension \u00b7 3/4\"",
      "quantity": 0.0625,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          620.1640263310185,
          1047.6854564525463
        ],
        [
          620.1640263310185,
          1049.2769820601852
        ]
      ]
    },
    {
      "id": "dim-213",
      "label": "Printed dimension \u00b7 5\"",
      "quantity": 0.4166666666666667,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          622.7475766782406,
          1038.3260091145833
        ],
        [
          624.296875,
          1038.3260091145833
        ]
      ]
    },
    {
      "id": "dim-214",
      "label": "Printed dimension \u00b7 3/4\"",
      "quantity": 0.0625,
      "unit": "LF",
      "color": "#398d79",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          620.1640263310185,
          1033.6589445891202
        ],
        [
          620.1640263310185,
          1035.2504701967591
        ]
      ]
    },
    {
      "id": "dim-215",
      "label": "Printed dimension \u00b7 4\"",
      "quantity": 0.3333333333333333,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          622.7475766782406,
          1026.6478587962963
        ],
        [
          624.296875,
          1026.6478587962963
        ]
      ]
    },
    {
      "id": "dim-216",
      "label": "Printed dimension \u00b7 4\"",
      "quantity": 0.3333333333333333,
      "unit": "LF",
      "color": "#b06bad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          622.7475766782406,
          1085.3167046440972
        ],
        [
          624.296875,
          1085.3167046440972
        ]
      ]
    },
    {
      "id": "dim-217",
      "label": "Printed dimension \u00b7 4\"",
      "quantity": 0.3333333333333333,
      "unit": "LF",
      "color": "#cf4f62",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          694.9820059317129,
          1085.3167046440972
        ],
        [
          696.5313042534722,
          1085.3167046440972
        ]
      ]
    },
    {
      "id": "dim-218",
      "label": "Printed dimension \u00b7 2\"",
      "quantity": 0.16666666666666666,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          672.426441333912,
          998.5646791811341
        ],
        [
          673.9757396556713,
          998.5646791811341
        ]
      ]
    },
    {
      "id": "dim-219",
      "label": "Printed dimension \u00b7 9\"",
      "quantity": 0.75,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          665.703870985243,
          1024.1800491898148
        ],
        [
          665.703870985243,
          1025.729347511574
        ]
      ]
    },
    {
      "id": "dim-220",
      "label": "Printed dimension \u00b7 3'-0\"",
      "quantity": 3.0,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          614.3329535590278,
          1049.355197482639
        ],
        [
          614.3329535590278,
          1051.1713324652776
        ]
      ]
    },
    {
      "id": "dim-221",
      "label": "Printed dimension \u00b7 6\"",
      "quantity": 0.5,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          622.7475766782406,
          1003.0135091145833
        ],
        [
          624.296875,
          1003.0135091145833
        ]
      ]
    },
    {
      "id": "dim-222",
      "label": "Printed dimension \u00b7 10'-1\"",
      "quantity": 10.083333333333334,
      "unit": "LF",
      "color": "#398d79",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          323.6049397786458,
          327.4266221788194
        ],
        [
          332.10331669560185,
          327.4266221788194
        ]
      ]
    },
    {
      "id": "dim-223",
      "label": "Printed dimension \u00b7 3'-2\"",
      "quantity": 3.1666666666666665,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          166.72461615668402,
          271.0106065538194
        ],
        [
          166.72461615668402,
          277.65380859375
        ]
      ]
    },
    {
      "id": "dim-224",
      "label": "Printed dimension \u00b7 9\"",
      "quantity": 0.75,
      "unit": "LF",
      "color": "#b06bad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          164.4473718713831,
          326.8638215241608
        ],
        [
          169.00186044198495,
          326.8638215241608
        ]
      ]
    },
    {
      "id": "dim-225",
      "label": "Printed dimension \u00b7 3'-11\"",
      "quantity": 3.9166666666666665,
      "unit": "LF",
      "color": "#cf4f62",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          157.82695628978587,
          279.9634919343171
        ],
        [
          157.82695628978587,
          288.46184624565973
        ]
      ]
    },
    {
      "id": "dim-227",
      "label": "Printed dimension \u00b7 2'-0\"",
      "quantity": 2.0,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          452.30685763888886,
          165.04040753399883
        ],
        [
          458.9500596788194,
          165.04040753399883
        ]
      ]
    },
    {
      "id": "dim-228",
      "label": "Printed dimension \u00b7 7'-6\"",
      "quantity": 7.5,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          506.49323640046293,
          233.19561993634258
        ],
        [
          506.49323640046293,
          239.83884458188655
        ]
      ]
    },
    {
      "id": "dim-229",
      "label": "Printed dimension \u00b7 10\"",
      "quantity": 0.8333333333333334,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          201.69395164207174,
          228.06373878761573
        ],
        [
          206.58876772280092,
          228.06373878761573
        ]
      ]
    },
    {
      "id": "dim-230",
      "label": "Printed dimension \u00b7 8\"",
      "quantity": 0.6666666666666666,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          183.9922134964554,
          225.7864945023148
        ],
        [
          183.9922134964554,
          230.34098307291666
        ]
      ]
    },
    {
      "id": "dim-231",
      "label": "Printed dimension \u00b7 1'-6\"",
      "quantity": 1.5,
      "unit": "LF",
      "color": "#398d79",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          192.0505325882523,
          215.9913917824074
        ],
        [
          198.69384765625,
          215.9913917824074
        ]
      ]
    },
    {
      "id": "dim-232",
      "label": "Printed dimension \u00b7 9\"",
      "quantity": 0.75,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          472.0535843460648,
          213.71414749710647
        ],
        [
          472.0535843460648,
          218.26863606770831
        ]
      ]
    },
    {
      "id": "dim-233",
      "label": "Printed dimension \u00b7 1'-3\"",
      "quantity": 1.25,
      "unit": "LF",
      "color": "#b06bad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          442.29700159143516,
          215.9913917824074
        ],
        [
          448.9402036313657,
          215.9913917824074
        ]
      ]
    },
    {
      "id": "dim-234",
      "label": "Printed dimension \u00b7 1'-9 1/2\"",
      "quantity": 1.7916666666666665,
      "unit": "LF",
      "color": "#cf4f62",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          1145.3431532118054,
          331.6218171296296
        ],
        [
          1157.5519024884259,
          331.6218171296296
        ]
      ]
    },
    {
      "id": "dim-235",
      "label": "Printed dimension \u00b7 1'-8 1/2\"",
      "quantity": 1.7083333333333335,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          1192.0558449074074,
          331.6218171296296
        ],
        [
          1204.264503761574,
          331.6218171296296
        ]
      ]
    },
    {
      "id": "dim-236",
      "label": "Printed dimension \u00b7 3'-6\"",
      "quantity": 3.5,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          1171.3413266782406,
          340.51945439091435
        ],
        [
          1177.984573929398,
          340.51945439091435
        ]
      ]
    },
    {
      "id": "dim-237",
      "label": "Printed dimension \u00b7 3'-7\"",
      "quantity": 3.5833333333333335,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          1265.87890625,
          340.51945439091435
        ],
        [
          1272.5220630787037,
          340.51945439091435
        ]
      ]
    },
    {
      "id": "dim-238",
      "label": "Printed dimension \u00b7 7'-1\"",
      "quantity": 7.083333333333333,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          1219.166214554398,
          349.4170916521991
        ],
        [
          1225.8094618055554,
          349.4170916521991
        ]
      ]
    },
    {
      "id": "dim-239",
      "label": "Printed dimension \u00b7 1/2\"",
      "quantity": 0.041666666666666664,
      "unit": "LF",
      "color": "#398d79",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          1306.5965892650463,
          317.5438548900463
        ],
        [
          1312.4189814814813,
          317.5438548900463
        ]
      ]
    },
    {
      "id": "dim-240",
      "label": "Printed dimension \u00b7 3'-3\"",
      "quantity": 3.25,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          1261.430031105324,
          196.18277090567128
        ],
        [
          1268.0732783564813,
          196.18277090567128
        ]
      ]
    },
    {
      "id": "dim-241",
      "label": "Printed dimension \u00b7 9\"",
      "quantity": 0.75,
      "unit": "LF",
      "color": "#b06bad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          1318.3954987702546,
          193.90552662037035
        ],
        [
          1318.3954987702546,
          198.4600151909722
        ]
      ]
    },
    {
      "id": "dim-242",
      "label": "Printed dimension \u00b7 1'-7\"",
      "quantity": 1.5833333333333335,
      "unit": "LF",
      "color": "#cf4f62",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          1400.7150607638887,
          327.2188313802083
        ],
        [
          1407.3583984375,
          327.2188313802083
        ]
      ]
    },
    {
      "id": "dim-243",
      "label": "Printed dimension \u00b7 1'-10 1/2\"",
      "quantity": 1.875,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          1444.2850296585648,
          327.1220341435185
        ],
        [
          1458.3488859953702,
          327.1220341435185
        ]
      ]
    },
    {
      "id": "dim-244",
      "label": "Printed dimension \u00b7 1'-10 1/2\"",
      "quantity": 1.875,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          1497.6708984375,
          327.2188313802083
        ],
        [
          1511.7348451967591,
          327.2188313802083
        ]
      ]
    },
    {
      "id": "dim-245",
      "label": "Printed dimension \u00b7 1'-10 1/2\"",
      "quantity": 1.875,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          1551.0568576388887,
          327.2188313802083
        ],
        [
          1565.1206235532406,
          327.2188313802083
        ]
      ]
    },
    {
      "id": "dim-246",
      "label": "Printed dimension \u00b7 1'-10 1/2\"",
      "quantity": 1.875,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          1604.4426359953702,
          327.2188313802083
        ],
        [
          1618.5065827546296,
          327.2188313802083
        ]
      ]
    },
    {
      "id": "dim-247",
      "label": "Printed dimension \u00b7 1'-1\"",
      "quantity": 1.0833333333333333,
      "unit": "LF",
      "color": "#398d79",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          1649.8491753472222,
          327.2188313802083
        ],
        [
          1656.4925130208333,
          327.2188313802083
        ]
      ]
    },
    {
      "id": "dim-248",
      "label": "Printed dimension \u00b7 1'-2\"",
      "quantity": 1.1666666666666667,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          1438.9472113715276,
          291.46751121238424
        ],
        [
          1445.590458622685,
          291.46751121238424
        ]
      ]
    },
    {
      "id": "dim-249",
      "label": "Printed dimension \u00b7 8\"",
      "quantity": 0.6666666666666666,
      "unit": "LF",
      "color": "#b06bad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          1468.3855523003472,
          289.1902669270833
        ],
        [
          1468.3855523003472,
          293.74475549768516
        ]
      ]
    },
    {
      "id": "dim-250",
      "label": "Printed dimension \u00b7 6 3/4\"",
      "quantity": 0.5625,
      "unit": "LF",
      "color": "#cf4f62",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          1483.2703993055554,
          275.5326786747685
        ],
        [
          1491.8755425347222,
          275.5326786747685
        ]
      ]
    },
    {
      "id": "dim-251",
      "label": "Printed dimension \u00b7 1'-3\"",
      "quantity": 1.25,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          1510.2673791956017,
          275.5326786747685
        ],
        [
          1516.9106264467591,
          275.5326786747685
        ]
      ]
    },
    {
      "id": "dim-252",
      "label": "Printed dimension \u00b7 1'-2\"",
      "quantity": 1.1666666666666667,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          1545.7190393518517,
          291.5643084490741
        ],
        [
          1552.3621961805554,
          291.5643084490741
        ]
      ]
    },
    {
      "id": "dim-253",
      "label": "Printed dimension \u00b7 8\"",
      "quantity": 0.6666666666666666,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          1575.1573350694443,
          289.28706416377315
        ],
        [
          1575.1573350694443,
          293.841552734375
        ]
      ]
    },
    {
      "id": "dim-254",
      "label": "Printed dimension \u00b7 6 3/4\"",
      "quantity": 0.5625,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          1590.0421368634259,
          275.5326786747685
        ],
        [
          1598.6472800925924,
          275.5326786747685
        ]
      ]
    },
    {
      "id": "dim-255",
      "label": "Printed dimension \u00b7 1'-3\"",
      "quantity": 1.25,
      "unit": "LF",
      "color": "#398d79",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          1617.0392071759259,
          275.5326786747685
        ],
        [
          1623.6823640046296,
          275.5326786747685
        ]
      ]
    },
    {
      "id": "dim-256",
      "label": "Printed dimension \u00b7 10'-8 3/4\"",
      "quantity": 10.729166666666666,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          1516.8564633969906,
          339.2596661603009
        ],
        [
          1530.9203197337963,
          339.2596661603009
        ]
      ]
    },
    {
      "id": "dim-257",
      "label": "Printed dimension \u00b7 2'-0\"",
      "quantity": 2.0,
      "unit": "LF",
      "color": "#b06bad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          1395.154079861111,
          226.6871021412037
        ],
        [
          1401.7973271122685,
          226.6871021412037
        ]
      ]
    },
    {
      "id": "dim-259",
      "label": "Printed dimension \u00b7 3/4\"",
      "quantity": 0.0625,
      "unit": "LF",
      "color": "#cf4f62",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          1390.1030815972222,
          245.3577564380787
        ],
        [
          1395.9254738136574,
          245.3577564380787
        ]
      ]
    },
    {
      "id": "dim-260",
      "label": "Printed dimension \u00b7 1/2\"",
      "quantity": 0.041666666666666664,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          1387.8974971064813,
          317.3215512876157
        ],
        [
          1393.7198893229165,
          317.3215512876157
        ]
      ]
    },
    {
      "id": "dim-261",
      "label": "Printed dimension \u00b7 10'-8 3/4\"",
      "quantity": 10.729166666666666,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          332.9212330005787,
          791.7887821903935
        ],
        [
          346.98511194299766,
          791.7887821903935
        ]
      ]
    },
    {
      "id": "dim-262",
      "label": "Printed dimension \u00b7 4 1/4\"",
      "quantity": 0.3541666666666667,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          483.96131727430554,
          791.7887821903935
        ],
        [
          492.5664605034722,
          791.7887821903935
        ]
      ]
    },
    {
      "id": "dim-263",
      "label": "Printed dimension \u00b7 5\"",
      "quantity": 0.4166666666666667,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          191.99827971281826,
          789.5115379050925
        ],
        [
          191.99827971281826,
          794.0660264756943
        ]
      ]
    },
    {
      "id": "dim-264",
      "label": "Printed dimension \u00b7 11'-6\"",
      "quantity": 11.5,
      "unit": "LF",
      "color": "#398d79",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          335.28510199652777,
          798.1610333478009
        ],
        [
          343.78347891348375,
          798.1610333478009
        ]
      ]
    },
    {
      "id": "dim-265",
      "label": "Printed dimension \u00b7 6'-6\"",
      "quantity": 6.5,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          157.03487820095484,
          681.2369339554398
        ],
        [
          157.03487820095484,
          687.8801359953703
        ]
      ]
    },
    {
      "id": "dim-266",
      "label": "Printed dimension \u00b7 2'-1\"",
      "quantity": 2.0833333333333335,
      "unit": "LF",
      "color": "#b06bad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          587.5080023871527,
          776.7263002748841
        ],
        [
          594.1511592158564,
          776.7263002748841
        ]
      ]
    },
    {
      "id": "dim-267",
      "label": "Printed dimension \u00b7 3/4\"",
      "quantity": 0.0625,
      "unit": "LF",
      "color": "#cf4f62",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          610.3322120949074,
          775.4037814670139
        ],
        [
          616.1545591001156,
          775.4037814670139
        ]
      ]
    },
    {
      "id": "dim-268",
      "label": "Printed dimension \u00b7 1'-4 1/4\"",
      "quantity": 1.3541666666666667,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          631.8568250868055,
          776.7263002748841
        ],
        [
          644.0654387297453,
          776.7263002748841
        ]
      ]
    },
    {
      "id": "dim-269",
      "label": "Printed dimension \u00b7 3'-6\"",
      "quantity": 3.5,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          606.4154730902777,
          785.6239601417824
        ],
        [
          613.0586751302083,
          785.6239601417824
        ]
      ]
    },
    {
      "id": "dim-270",
      "label": "Printed dimension \u00b7 2\"",
      "quantity": 0.16666666666666666,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          660.2510805483217,
          707.4954788773148
        ],
        [
          660.2510805483217,
          709.5612250434027
        ]
      ]
    },
    {
      "id": "dim-271",
      "label": "Printed dimension \u00b7 9\"",
      "quantity": 0.75,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          562.1701841001156,
          658.8983380353009
        ],
        [
          562.1701841001156,
          663.4528266059027
        ]
      ]
    },
    {
      "id": "dim-272",
      "label": "Printed dimension \u00b7 3'-2\"",
      "quantity": 3.1666666666666665,
      "unit": "LF",
      "color": "#398d79",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          610.8643030237268,
          661.1755823206017
        ],
        [
          617.5074598524305,
          661.1755823206017
        ]
      ]
    },
    {
      "id": "dim-273",
      "label": "Printed dimension \u00b7 4'-11\"",
      "quantity": 4.916666666666667,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          409.47455512152777,
          198.20271809895831
        ],
        [
          409.47455512152777,
          206.70109501591435
        ]
      ]
    },
    {
      "id": "dim-274",
      "label": "Printed dimension \u00b7 2'-7\"",
      "quantity": 2.5833333333333335,
      "unit": "LF",
      "color": "#b06bad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          409.47455512152777,
          299.20502839265043
        ],
        [
          409.47455512152777,
          305.848230432581
        ]
      ]
    },
    {
      "id": "dim-275",
      "label": "Printed dimension \u00b7 11'-6\"",
      "quantity": 11.5,
      "unit": "LF",
      "color": "#cf4f62",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          324.1746916594328,
          358.3112476490162
        ],
        [
          332.67306857638886,
          358.3112476490162
        ]
      ]
    },
    {
      "id": "dim-278",
      "label": "Printed dimension \u00b7 1 3/4\"",
      "quantity": 0.14583333333333334,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          374.3808774594907,
          671.5211769386574
        ],
        [
          382.9860206886574,
          671.5211769386574
        ]
      ]
    },
    {
      "id": "desk-top-envelope",
      "label": "Registration desk composite countertop plan envelope",
      "quantity": 42.18,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Approximate digitized outline calibrated by 11 ft 6 in overall dimension. Composite envelope includes ST-01 and PL worktop surfaces; do NOT treat all as quartz. Cutouts not deducted; confirm split with fabrication drawings.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "polygons": [
        [
          [
            174,
            232
          ],
          [
            215,
            232
          ],
          [
            215,
            268
          ],
          [
            428,
            268
          ],
          [
            428,
            135
          ],
          [
            482,
            135
          ],
          [
            482,
            307
          ],
          [
            479.6402655078499,
            318.8631864033178
          ],
          [
            472.920310216783,
            328.920310216783
          ],
          [
            462.8631864033178,
            335.6402655078499
          ],
          [
            451.0,
            338.0
          ],
          [
            174,
            338
          ]
        ]
      ]
    },
    {
      "id": "desk-overall",
      "label": "Overall desk front width",
      "quantity": 11.5,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Printed 11 ft 6 in; dimension span about 308 px gives 26.78 px/ft.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          174,
          352
        ],
        [
          482,
          352
        ]
      ]
    },
    {
      "id": "desk-return",
      "label": "Overall desk return depth",
      "quantity": 7.5,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Printed 7 ft 6 in; source span about203 px gives27.07 px/ft, approximate manual endpoint selection.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          495,
          135
        ],
        [
          495,
          338
        ]
      ]
    },
    {
      "id": "desk-front-body",
      "label": "Front desk casework body width",
      "quantity": 10.7291667,
      "unit": "LF",
      "color": "#398d79",
      "basis": "Printed10 ft8 3/4 in; do not add to overall desk width.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          198,
          770
        ],
        [
          484,
          770
        ]
      ]
    },
    {
      "id": "desk-front-panel",
      "label": "Front face including ribbed portion",
      "quantity": 32.175,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Gross projected visible front face: traced 286 x 80 normalized pixels at 26.6667 px/ft. Excludes base. Ribbed face below is an included subset, not additive.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "polygons": [
        [
          [
            198,
            682
          ],
          [
            484,
            682
          ],
          [
            484,
            762
          ],
          [
            198,
            762
          ]
        ]
      ]
    },
    {
      "id": "ribbed-front",
      "label": "Ribbed front panel projected face",
      "quantity": 12.937499999999998,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Projected front face trace 115 x 80 normalized pixels. Curved return and rib profiles need developed fabrication area; printed 4ft8 paneling dimension is retained separately. Included in gross front face.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "polygons": [
        [
          [
            369,
            682
          ],
          [
            484,
            682
          ],
          [
            484,
            762
          ],
          [
            369,
            762
          ]
        ]
      ]
    },
    {
      "id": "ribbed-front-width",
      "label": "Printed paneling width reference",
      "quantity": 4.6666667,
      "unit": "LF",
      "color": "#cf4f62",
      "basis": "Printed 4ft8 of paneling. Curved corner and exposed rib edges require shop drawing development; this dimension alone does not establish developed material area.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "line": [
        [
          369,
          663
        ],
        [
          494,
          663
        ]
      ]
    },
    {
      "id": "baffle-footprints",
      "label": "Three nominal baffle module footprints",
      "quantity": 108,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "3 modules \u00d7 approximately4ft \u00d7 approximately9ft; overhead plan footprint only, not acoustical slat exposed surface area.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "polygons": [
        [
          [
            617,
            125
          ],
          [
            719,
            125
          ],
          [
            719,
            366
          ],
          [
            617,
            366
          ]
        ],
        [
          [
            731,
            125
          ],
          [
            830,
            125
          ],
          [
            830,
            366
          ],
          [
            731,
            366
          ]
        ],
        [
          [
            842,
            125
          ],
          [
            945,
            125
          ],
          [
            945,
            366
          ],
          [
            842,
            366
          ]
        ]
      ]
    },
    {
      "id": "baffle-slats",
      "label": "Thirty nominal baffle slat lengths",
      "quantity": 270,
      "unit": "LF",
      "color": "#299bba",
      "basis": "30 drawn slats \u00d7 approximately9ft module length; allowance pending ACB-01 product spacing and manufacturer details.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "lines": [
        [
          [
            617.553,
            125
          ],
          [
            617.553,
            366
          ]
        ],
        [
          [
            628.675,
            125
          ],
          [
            628.675,
            366
          ]
        ],
        [
          [
            639.797,
            125
          ],
          [
            639.797,
            366
          ]
        ],
        [
          [
            650.919,
            125
          ],
          [
            650.919,
            366
          ]
        ],
        [
          [
            662.0409999999999,
            125
          ],
          [
            662.0409999999999,
            366
          ]
        ],
        [
          [
            673.163,
            125
          ],
          [
            673.163,
            366
          ]
        ],
        [
          [
            684.285,
            125
          ],
          [
            684.285,
            366
          ]
        ],
        [
          [
            695.407,
            125
          ],
          [
            695.407,
            366
          ]
        ],
        [
          [
            706.529,
            125
          ],
          [
            706.529,
            366
          ]
        ],
        [
          [
            717.651,
            125
          ],
          [
            717.651,
            366
          ]
        ],
        [
          [
            729.885,
            125
          ],
          [
            729.885,
            366
          ]
        ],
        [
          [
            741.007,
            125
          ],
          [
            741.007,
            366
          ]
        ],
        [
          [
            752.129,
            125
          ],
          [
            752.129,
            366
          ]
        ],
        [
          [
            763.251,
            125
          ],
          [
            763.251,
            366
          ]
        ],
        [
          [
            774.373,
            125
          ],
          [
            774.373,
            366
          ]
        ],
        [
          [
            785.495,
            125
          ],
          [
            785.495,
            366
          ]
        ],
        [
          [
            796.617,
            125
          ],
          [
            796.617,
            366
          ]
        ],
        [
          [
            807.739,
            125
          ],
          [
            807.739,
            366
          ]
        ],
        [
          [
            818.861,
            125
          ],
          [
            818.861,
            366
          ]
        ],
        [
          [
            829.983,
            125
          ],
          [
            829.983,
            366
          ]
        ],
        [
          [
            842.218,
            125
          ],
          [
            842.218,
            366
          ]
        ],
        [
          [
            853.3399999999999,
            125
          ],
          [
            853.3399999999999,
            366
          ]
        ],
        [
          [
            864.462,
            125
          ],
          [
            864.462,
            366
          ]
        ],
        [
          [
            875.584,
            125
          ],
          [
            875.584,
            366
          ]
        ],
        [
          [
            886.7059999999999,
            125
          ],
          [
            886.7059999999999,
            366
          ]
        ],
        [
          [
            897.828,
            125
          ],
          [
            897.828,
            366
          ]
        ],
        [
          [
            908.9499999999999,
            125
          ],
          [
            908.9499999999999,
            366
          ]
        ],
        [
          [
            920.072,
            125
          ],
          [
            920.072,
            366
          ]
        ],
        [
          [
            931.194,
            125
          ],
          [
            931.194,
            366
          ]
        ],
        [
          [
            942.3159999999999,
            125
          ],
          [
            942.3159999999999,
            366
          ]
        ]
      ]
    },
    {
      "id": "baffle-module-rails-135",
      "label": "Module cross rails at source row 135",
      "quantity": 12,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Three4ft approximate module rails shown in this row;9 rails/36LF total for these3 rows. Separate longer mounting members also visible; not substitute for engineered suspension takeoff.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "lines": [
        [
          [
            617,
            135
          ],
          [
            719,
            135
          ]
        ],
        [
          [
            731,
            135
          ],
          [
            830,
            135
          ]
        ],
        [
          [
            842,
            135
          ],
          [
            945,
            135
          ]
        ]
      ]
    },
    {
      "id": "baffle-module-rails-246",
      "label": "Module cross rails at source row 246",
      "quantity": 12,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Three4ft approximate module rails shown in this row;9 rails/36LF total for these3 rows. Separate longer mounting members also visible; not substitute for engineered suspension takeoff.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "lines": [
        [
          [
            617,
            246
          ],
          [
            719,
            246
          ]
        ],
        [
          [
            731,
            246
          ],
          [
            830,
            246
          ]
        ],
        [
          [
            842,
            246
          ],
          [
            945,
            246
          ]
        ]
      ]
    },
    {
      "id": "baffle-module-rails-355",
      "label": "Module cross rails at source row 355",
      "quantity": 12,
      "unit": "LF",
      "color": "#398d79",
      "basis": "Three4ft approximate module rails shown in this row;9 rails/36LF total for these3 rows. Separate longer mounting members also visible; not substitute for engineered suspension takeoff.",
      "sourceSheet": "A7.10",
      "parentSheet": "Reception",
      "lines": [
        [
          [
            617,
            355
          ],
          [
            719,
            355
          ]
        ],
        [
          [
            731,
            355
          ],
          [
            830,
            355
          ]
        ],
        [
          [
            842,
            355
          ],
          [
            945,
            355
          ]
        ]
      ]
    }
  ]
}