  "sheet": "A6.4",
  "coordinateSpace": {
    "width": 1920,
    "height": 1280
  },
  "calibration": {
    "pixelsPerFoot": null,
    "printedScale": "UNLABELED; local roof/RCP basis",
    "checks": [
      {
        "view": "RCP13ft width",
        "pixelsPerFoot": 13.333307692307692,
        "sourcePixels": 173.333,
        "referenceFeet": 13
      },
      {
        "view": "Roof length17ft11-1/2 plus22ft",
        "pixelsPerFoot": 13.338894681960378,
        "sourcePixels": 533,
        "referenceFeet": 39.95833333333333
      },
      {
        "view": "Detail drawings",
        "status": "UNLABELED / mixed scales; no global measurement"
      }
    ]
  },
  "rows": [
    {
      "id": "dim-67",
      "label": "Printed dimension \u00b7 3'-0\"",
      "quantity": 3.0,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.4",
      "parentSheet": "Entry Canopy",
      "line": [
        [
          542.7261465567129,
          325.4866536458333
        ],
        [
          550.5964717158564,
          325.4866536458333
        ]
      ]
    },
    {
      "id": "dim-68",
      "label": "Printed dimension \u00b7 10'-9\"",
      "quantity": 10.75,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.4",
      "parentSheet": "Entry Canopy",
      "line": [
        [
          731.1732313368055,
          451.37659143518516
        ],
        [
          731.1732313368055,
          461.444679542824
        ]
      ]
    },
    {
      "id": "dim-69",
      "label": "Printed dimension \u00b7 12'-2\"",
      "quantity": 12.166666666666666,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.4",
      "parentSheet": "Entry Canopy",
      "line": [
        [
          869.0601942274305,
          438.589454933449
        ],
        [
          869.0601942274305,
          453.3043077256944
        ]
      ]
    },
    {
      "id": "dim-70",
      "label": "Printed dimension \u00b7 8'-11 3/4\"",
      "quantity": 8.979166666666666,
      "unit": "LF",
      "color": "#398d79",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.4",
      "parentSheet": "Entry Canopy",
      "line": [
        [
          543.7791838469329,
          455.09073893229163
        ],
        [
          543.7791838469329,
          479.4417317708333
        ]
      ]
    },
    {
      "id": "dim-71",
      "label": "Printed dimension \u00b7 17'-11 1/2\"",
      "quantity": 17.958333333333332,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.4",
      "parentSheet": "Entry Canopy",
      "line": [
        [
          672.7210828993055,
          324.4861970124421
        ],
        [
          700.284107349537,
          324.4861970124421
        ]
      ]
    },
    {
      "id": "dim-72",
      "label": "Printed dimension \u00b7 22'-0\"",
      "quantity": 22.0,
      "unit": "LF",
      "color": "#b06bad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.4",
      "parentSheet": "Entry Canopy",
      "line": [
        [
          945.7553891782406,
          324.4861970124421
        ],
        [
          960.4701967592592,
          324.4861970124421
        ]
      ]
    },
    {
      "id": "dim-73",
      "label": "Printed dimension \u00b7 5'-2\"",
      "quantity": 5.166666666666667,
      "unit": "LF",
      "color": "#cf4f62",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.4",
      "parentSheet": "Entry Canopy",
      "line": [
        [
          555.2884024160879,
          415.30225965711804
        ],
        [
          566.7911783854166,
          415.30225965711804
        ]
      ]
    },
    {
      "id": "dim-74",
      "label": "Printed dimension \u00b7 13'-0\"",
      "quantity": 13.0,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.4",
      "parentSheet": "Entry Canopy",
      "line": [
        [
          1526.9326895254628,
          67.9274015073423
        ],
        [
          1541.6474971064813,
          67.9274015073423
        ]
      ]
    },
    {
      "id": "dim-75",
      "label": "Printed dimension \u00b7 11'-3\"",
      "quantity": 11.25,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.4",
      "parentSheet": "Entry Canopy",
      "line": [
        [
          1527.4540653935185,
          577.8117540147568
        ],
        [
          1542.168872974537,
          577.8117540147568
        ]
      ]
    },
    {
      "id": "roof-main",
      "label": "Detached canopy roof projected area",
      "quantity": 519.4583333333333,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Dimension-based rectangle:13ft width \u00d7(17ft11-1/2 +22ft) roof length. Confirm edge offsets/step connections before procurement; sloped surface, waste, curbs and attached piece separate.",
      "sourceSheet": "A6.4",
      "parentSheet": "Entry Canopy",
      "polygons": [
        [
          [
            1183,
            71
          ],
          [
            1356,
            71
          ],
          [
            1356,
            604
          ],
          [
            1183,
            604
          ]
        ]
      ]
    },
    {
      "id": "roof-main-perimeter",
      "label": "Main canopy rectangular perimeter",
      "quantity": 105.91666666666666,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Dimension-based perimeter reference. Not automatically coping/gutter LF on every edge; distinguish gutter, attached joint and overflow details.",
      "sourceSheet": "A6.4",
      "parentSheet": "Entry Canopy",
      "line": [
        [
          1183,
          71
        ],
        [
          1356,
          71
        ],
        [
          1356,
          604
        ],
        [
          1183,
          604
        ],
        [
          1183,
          71
        ]
      ]
    },
    {
      "id": "soffit-main",
      "label": "Main canopy soffit projected trace",
      "quantity": 472.5018173129346,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Approximate clear RCP underside field between column/edge lines. Wood-look aluminum source finish. Confirm roof-to-soffit offset and separately attached strip; not added to roof area as one material.",
      "sourceSheet": "A6.4",
      "parentSheet": "Entry Canopy",
      "polygons": [
        [
          [
            1454,
            92
          ],
          [
            1614,
            92
          ],
          [
            1614,
            617
          ],
          [
            1454,
            617
          ]
        ]
      ]
    },
    {
      "id": "soffit-attached",
      "label": "Attached lower soffit strip reference",
      "quantity": 32.46762487536022,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Approximate separately attached building canopy strip in RCP. Source marks attached piece separately; verify depth/overlap and actual finish boundary before net quantities.",
      "sourceSheet": "A6.4",
      "parentSheet": "Entry Canopy",
      "polygons": [
        [
          [
            1461,
            620
          ],
          [
            1609,
            620
          ],
          [
            1609,
            659
          ],
          [
            1461,
            659
          ]
        ]
      ]
    },
    {
      "id": "gutter-main",
      "label": "Main roof transverse gutter traces",
      "quantity": 12.150023365429549,
      "unit": "LF",
      "color": "#b06bad",
      "basis": "One transverse gutter run shown; other transverse run recorded separately. Actual slopes/downpipe/attachments require trade details.",
      "sourceSheet": "A6.4",
      "parentSheet": "Entry Canopy",
      "line": [
        [
          1189,
          358
        ],
        [
          1351,
          358
        ],
        [
          1351,
          358
        ]
      ]
    },
    {
      "id": "gutter-lower",
      "label": "Lower roof transverse gutter trace",
      "quantity": 12.150023365429549,
      "unit": "LF",
      "color": "#cf4f62",
      "basis": "Second roof gutter run shown; drain appendage and connection length not inferred.",
      "sourceSheet": "A6.4",
      "parentSheet": "Entry Canopy",
      "line": [
        [
          1189,
          594
        ],
        [
          1351,
          594
        ]
      ]
    }
  ]
}