  "sheet": "A6.3",
  "coordinateSpace": {
    "width": 1920,
    "height": 1280
  },
  "calibration": {
    "pixelsPerFoot": null,
    "printedScale": "UNLABELED; local dimension basis",
    "checks": [
      {
        "view": "Patio section12ft7 horizontal dimension",
        "pixelsPerFoot": 26.701986754966885,
        "sourcePixels": 336,
        "referenceFeet": 12.583333333333334
      },
      {
        "view": "Masonry footing",
        "status": "EXPLICIT DIMENSIONS ONLY",
        "basis": "5ft width and1ft6 depth retained as stated; no geometry calibration needed for unit-rate volume."
      },
      {
        "view": "Mixed unlabelled detail scales",
        "status": "LOCAL DIMENSION BASIS ONLY"
      }
    ]
  },
  "rows": [
    {
      "id": "dim-38",
      "label": "Printed dimension \u00b7 12'-7\"",
      "quantity": 12.583333333333334,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.3",
      "parentSheet": "Site / Envelope",
      "line": [
        [
          1130.9995298032406,
          99.69627662941261
        ],
        [
          1148.9406105324074,
          99.69627662941261
        ]
      ]
    },
    {
      "id": "dim-39",
      "label": "Printed dimension \u00b7 8'-11 3/4\"",
      "quantity": 8.979166666666666,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.3",
      "parentSheet": "Site / Envelope",
      "line": [
        [
          1072.6713053385415,
          300.04267939814815
        ],
        [
          1072.6713053385415,
          329.73298249421293
        ]
      ]
    },
    {
      "id": "dim-40",
      "label": "Printed dimension \u00b7 1 1/2\"",
      "quantity": 0.125,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.3",
      "parentSheet": "Site / Envelope",
      "line": [
        [
          947.8189199942129,
          308.31381338614005
        ],
        [
          965.9853334780092,
          308.31381338614005
        ]
      ]
    },
    {
      "id": "dim-41",
      "label": "Printed dimension \u00b7 6'-0\"",
      "quantity": 6.0,
      "unit": "LF",
      "color": "#398d79",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.3",
      "parentSheet": "Site / Envelope",
      "line": [
        [
          1044.7207754629628,
          186.9834221733941
        ],
        [
          1058.7452980324074,
          186.9834221733941
        ]
      ]
    },
    {
      "id": "dim-106",
      "label": "Printed dimension \u00b7 11 1/4\"",
      "quantity": 0.9375,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.3",
      "parentSheet": "Site / Envelope",
      "line": [
        [
          839.6373155381943,
          635.6740541811342
        ],
        [
          861.7201063368055,
          635.6740541811342
        ]
      ]
    },
    {
      "id": "dim-107",
      "label": "Printed dimension \u00b7 1'-0\"",
      "quantity": 1.0,
      "unit": "LF",
      "color": "#b06bad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.3",
      "parentSheet": "Site / Envelope",
      "line": [
        [
          779.5864529079861,
          987.2007016782406
        ],
        [
          779.5864529079861,
          1001.2253146701388
        ]
      ]
    },
    {
      "id": "dim-108",
      "label": "Printed dimension \u00b7 5'-0\"",
      "quantity": 5.0,
      "unit": "LF",
      "color": "#cf4f62",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.3",
      "parentSheet": "Site / Envelope",
      "line": [
        [
          829.1816767939814,
          1167.7949128327546
        ],
        [
          843.2061993634259,
          1167.7949128327546
        ]
      ]
    },
    {
      "id": "dim-109",
      "label": "Printed dimension \u00b7 1'-6\"",
      "quantity": 1.5,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.3",
      "parentSheet": "Site / Envelope",
      "line": [
        [
          621.3301595052083,
          1087.2993525752315
        ],
        [
          621.3301595052083,
          1101.3237847222222
        ]
      ]
    },
    {
      "id": "dim-110",
      "label": "Printed dimension \u00b7 3'-6\"",
      "quantity": 3.5,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.3",
      "parentSheet": "Site / Envelope",
      "line": [
        [
          779.5864529079861,
          807.0233832465277
        ],
        [
          779.5864529079861,
          821.0479962384259
        ]
      ]
    },
    {
      "id": "dim-111",
      "label": "Printed dimension \u00b7 3'-4 3/4\"",
      "quantity": 3.3958333333333335,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.3",
      "parentSheet": "Site / Envelope",
      "line": [
        [
          1430.2760145399304,
          810.3309461805555
        ],
        [
          1430.2760145399304,
          836.1048719618055
        ]
      ]
    },
    {
      "id": "dim-112",
      "label": "Printed dimension \u00b7 10\"",
      "quantity": 0.8333333333333334,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.3",
      "parentSheet": "Site / Envelope",
      "line": [
        [
          1406.9505931712963,
          943.7482367621527
        ],
        [
          1417.2840711805554,
          943.7482367621527
        ]
      ]
    },
    {
      "id": "dim-113",
      "label": "Printed dimension \u00b7 7\"",
      "quantity": 0.5833333333333334,
      "unit": "LF",
      "color": "#398d79",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.3",
      "parentSheet": "Site / Envelope",
      "line": [
        [
          1327.2864221643517,
          672.9130045572916
        ],
        [
          1327.2864221643517,
          682.5279857494213
        ]
      ]
    },
    {
      "id": "dim-114",
      "label": "Printed dimension \u00b7 2'-0\"",
      "quantity": 2.0,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.3",
      "parentSheet": "Site / Envelope",
      "line": [
        [
          284.5246491608796,
          1067.0741554542824
        ],
        [
          298.54914912471065,
          1067.0741554542824
        ]
      ]
    },
    {
      "id": "dim-115",
      "label": "Printed dimension \u00b7 10\"",
      "quantity": 0.8333333333333334,
      "unit": "LF",
      "color": "#b06bad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.3",
      "parentSheet": "Site / Envelope",
      "line": [
        [
          328.4376921477141,
          1036.9980649594906
        ],
        [
          328.4376921477141,
          1047.3314525462963
        ]
      ]
    },
    {
      "id": "dim-116",
      "label": "Printed dimension \u00b7 4 1/2\"",
      "quantity": 0.375,
      "unit": "LF",
      "color": "#cf4f62",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.3",
      "parentSheet": "Site / Envelope",
      "line": [
        [
          347.96368634259255,
          1050.653980396412
        ],
        [
          366.1300320095486,
          1050.653980396412
        ]
      ]
    },
    {
      "id": "dim-117",
      "label": "Printed dimension \u00b7 1'-6\"",
      "quantity": 1.5,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.3",
      "parentSheet": "Site / Envelope",
      "line": [
        [
          307.15069806134255,
          749.1452817563656
        ],
        [
          321.1751980251736,
          749.1452817563656
        ]
      ]
    },
    {
      "id": "dim-118",
      "label": "Printed dimension \u00b7 10\"",
      "quantity": 0.8333333333333334,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.3",
      "parentSheet": "Site / Envelope",
      "line": [
        [
          258.2944177698206,
          716.5480776186342
        ],
        [
          258.2944177698206,
          726.8815104166666
        ]
      ]
    },
    {
      "id": "dim-119",
      "label": "Printed dimension \u00b7 1'-1 1/2\"",
      "quantity": 1.125,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Explicit source dimension; qualifiers, orientation and extension-line endpoints govern. Not an installed run or automatic page calibration. See complete source context.",
      "sourceSheet": "A6.3",
      "parentSheet": "Site / Envelope",
      "line": [
        [
          287.42133246527777,
          676.0720938223379
        ],
        [
          313.19514521846065,
          676.0720938223379
        ]
      ]
    },
    {
      "id": "trellis-projection",
      "label": "Trellis overall projected screen envelope",
      "quantity": 113.10019841269842,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Approximate overall section envelope from printed12ft7 width; 8ft11-3/4 vertical dimension supports local scale. OPEN slatted assembly, not solid cladding SF or wood volume.",
      "sourceSheet": "A6.3",
      "parentSheet": "Site / Envelope",
      "polygons": [
        [
          [
            970,
            198
          ],
          [
            1306,
            198
          ],
          [
            1306,
            438
          ],
          [
            970,
            438
          ]
        ]
      ]
    },
    {
      "id": "trellis-shown-height",
      "label": "Trellis printed vertical height",
      "quantity": 8.979166666666666,
      "unit": "LF",
      "color": "#398d79",
      "basis": "Source vertical dimension8ft11-3/4. Do not assign every slat this cut length: base, cap and connections modify member lengths.",
      "sourceSheet": "A6.3",
      "parentSheet": "Site / Envelope",
      "line": [
        [
          1066,
          201
        ],
        [
          1066,
          439
        ]
      ]
    },
    {
      "id": "footing-unit-concrete",
      "label": "5ft \u00d71ft6 footing \u00b7 volume per1LF",
      "quantity": 0.2777777777777778,
      "unit": "CY",
      "color": "#ba9138",
      "basis": "UNIT RATE ONLY from explicit footing section5ft width \u00d71ft6 depth \u00d71LF. No actual footing run assigned; do not multiply by trellis width without plan confirmation. Stem and reinforcement separate.",
      "sourceSheet": "A6.3",
      "parentSheet": "Site / Envelope",
      "polygons": [
        [
          [
            616,
            1033
          ],
          [
            1074,
            1033
          ],
          [
            1074,
            1160
          ],
          [
            616,
            1160
          ]
        ]
      ]
    },
    {
      "id": "brick-face-unit",
      "label": "3ft6 brick wall \u00b7 one-face area per1LF",
      "quantity": 3.5,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "UNIT RATE ONLY from printed3ft6 height. One face; opposite face and actual wall length separate. Masonry cores/grout/steel quantities require section and design.",
      "sourceSheet": "A6.3",
      "parentSheet": "Site / Envelope",
      "line": [
        [
          785,
          674
        ],
        [
          785,
          953
        ]
      ]
    },
    {
      "id": "cap-unit-area",
      "label": "11-1/4-inch cap \u00b7 top area per1LF",
      "quantity": 0.9375,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "UNIT RATE ONLY for stated cap width. Cap thickness, slope, lengths/joints and run extent unresolved; no precast volume inferred.",
      "sourceSheet": "A6.3",
      "parentSheet": "Site / Envelope",
      "line": [
        [
          815,
          644
        ],
        [
          890,
          644
        ]
      ]
    }
  ]
}