  "sheet": "A4.2",
  "pdfPage": 39,
  "coordinateBasis": "PDF points divided by1.35 = normalized1920x1280",
  "words": [
    [
      1012.6640625,
      194.20814514160156,
      1025.349609375,
      220.168701171875,
      "A",
      0,
      0,
      0
    ],
    [
      893.6719970703125,
      194.20814514160156,
      906.3574829101562,
      220.168701171875,
      "B",
      0,
      1,
      0
    ],
    [
      745.2089233398438,
      194.20814514160156,
      758.9404296875,
      220.168701171875,
      "C",
      0,
      2,
      0
    ],
    [
      695.66015625,
      194.20814514160156,
      709.3916625976562,
      220.168701171875,
      "D",
      0,
      3,
      0
    ],
    [
      654.5615844726562,
      194.20814514160156,
      667.2470703125,
      220.168701171875,
      "E",
      0,
      4,
      0
    ],
    [
      590.8416137695312,
      194.20814514160156,
      602.4620361328125,
      220.168701171875,
      "F",
      0,
      5,
      0
    ],
    [
      449.42755126953125,
      194.20814514160156,
      464.22412109375,
      220.168701171875,
      "G",
      0,
      6,
      0
    ],
    [
      428.7724609375,
      194.20814514160156,
      442.50396728515625,
      220.168701171875,
      "H",
      0,
      7,
      0
    ],
    [
      376.79058837890625,
      194.20814514160156,
      386.2999572753906,
      220.168701171875,
      "J",
      0,
      8,
      0
    ],
    [
      356.13995361328125,
      194.20814514160156,
      381.51092529296875,
      220.168701171875,
      "J.1",
      0,
      9,
      0
    ],
    [
      1034.9056396484375,
      781.5574951171875,
      1071.0537109375,
      798.6368408203125,
      "FIRST",
      1,
      0,
      0
    ],
    [
      1074.5321044921875,
      781.5574951171875,
      1117.6370849609375,
      798.6368408203125,
      "FLOOR",
      1,
      0,
      1
    ],
    [
      1086.392578125,
      794.892333984375,
      1095.7392578125,
      811.9716796875,
      "0'",
      2,
      0,
      0
    ],
    [
      1099.2176513671875,
      794.892333984375,
      1103.38427734375,
      811.9716796875,
      "-",
      2,
      0,
      1
    ],
    [
      1106.8626708984375,
      794.892333984375,
      1118.261474609375,
      811.9716796875,
      "0\"",
      2,
      0,
      2
    ],
    [
      1017.6256103515625,
      667.4451904296875,
      1071.1533203125,
      684.5245361328125,
      "SECOND",
      3,
      0,
      0
    ],
    [
      1074.6317138671875,
      667.4451904296875,
      1117.7366943359375,
      684.5245361328125,
      "FLOOR",
      3,
      0,
      1
    ],
    [
      1079.4407958984375,
      680.780029296875,
      1095.744384765625,
      697.859375,
      "12'",
      4,
      0,
      0
    ],
    [
      1099.2227783203125,
      680.780029296875,
      1103.389404296875,
      697.859375,
      "-",
      4,
      0,
      1
    ],
    [
      1106.8677978515625,
      680.780029296875,
      1118.2666015625,
      697.859375,
      "8\"",
      4,
      0,
      2
    ],
    [
      1033.0045166015625,
      580.3594360351562,
      1071.229736328125,
      597.4387817382812,
      "THIRD",
      5,
      0,
      0
    ],
    [
      1074.7081298828125,
      580.3594360351562,
      1117.81298828125,
      597.4387817382812,
      "FLOOR",
      5,
      0,
      1
    ],
    [
      1079.4407958984375,
      593.6943359375,
      1095.744384765625,
      610.773681640625,
      "22'",
      6,
      0,
      0
    ],
    [
      1099.2227783203125,
      593.6943359375,
      1103.389404296875,
      610.773681640625,
      "-",
      6,
      0,
      1
    ],
    [
      1106.8677978515625,
      593.6943359375,
      1118.2666015625,
      610.773681640625,
      "4\"",
      6,
      0,
      2
    ],
    [
      1019.1295166015625,
      493.27374267578125,
      1071.255859375,
      510.35302734375,
      "FOURTH",
      7,
      0,
      0
    ],
    [
      1074.7342529296875,
      493.27374267578125,
      1117.839111328125,
      510.35302734375,
      "FLOOR",
      7,
      0,
      1
    ],
    [
      1079.4407958984375,
      506.608642578125,
      1095.744384765625,
      523.68798828125,
      "32'",
      8,
      0,
      0
    ],
    [
      1099.2227783203125,
      506.608642578125,
      1103.389404296875,
      523.68798828125,
      "-",
      8,
      0,
      1
    ],
    [
      1106.8677978515625,
      506.608642578125,
      1118.2666015625,
      523.68798828125,
      "0\"",
      8,
      0,
      2
    ],
    [
      1035.643310546875,
      406.18804931640625,
      1071.0908203125,
      423.267333984375,
      "FIFTH",
      9,
      0,
      0
    ],
    [
      1074.5692138671875,
      406.18804931640625,
      1117.674072265625,
      423.267333984375,
      "FLOOR",
      9,
      0,
      1
    ],
    [
      1079.4407958984375,
      419.52288818359375,
      1095.744384765625,
      436.6022033691406,
      "41'",
      10,
      0,
      0
    ],
    [
      1099.2227783203125,
      419.52288818359375,
      1103.389404296875,
      436.6022033691406,
      "-",
      10,
      0,
      1
    ],
    [
      1106.8677978515625,
      419.52288818359375,
      1118.2666015625,
      436.6022033691406,
      "8\"",
      10,
      0,
      2
    ],
    [
      1045.4041748046875,
      319.102294921875,
      1081.55224609375,
      336.1816101074219,
      "ROOF",
      11,
      0,
      0
    ],
    [
      1085.0306396484375,
      319.102294921875,
      1117.712890625,
      336.1816101074219,
      "PLAN",
      11,
      0,
      1
    ],
    [
      1079.4407958984375,
      332.43719482421875,
      1095.744384765625,
      349.5165100097656,
      "51'",
      12,
      0,
      0
    ],
    [
      1099.2227783203125,
      332.43719482421875,
      1103.389404296875,
      349.5165100097656,
      "-",
      12,
      0,
      1
    ],
    [
      1106.8677978515625,
      332.43719482421875,
      1118.2666015625,
      349.5165100097656,
      "4\"",
      12,
      0,
      2
    ],
    [
      1038.0836181640625,
      292.07568359375,
      1055.4632568359375,
      309.1549987792969,
      "TO",
      13,
      0,
      0
    ],
    [
      1058.941650390625,
      292.07568359375,
      1117.34912109375,
      309.1549987792969,
      "PARAPET",
      13,
      0,
      1
    ],
    [
      1079.4407958984375,
      305.41058349609375,
      1095.744384765625,
      322.4898986816406,
      "54'",
      14,
      0,
      0
    ],
    [
      1099.2227783203125,
      305.41058349609375,
      1103.389404296875,
      322.4898986816406,
      "-",
      14,
      0,
      1
    ],
    [
      1106.8677978515625,
      305.41058349609375,
      1118.2666015625,
      322.4898986816406,
      "4\"",
      14,
      0,
      2
    ],
    [
      333.80548095703125,
      194.20814514160156,
      359.17645263671875,
      220.168701171875,
      "J.2",
      15,
      0,
      0
    ],
    [
      1874.419189453125,
      967.15380859375,
      1884.99365234375,
      993.1143798828125,
      "1",
      16,
      0,
      0
    ],
    [
      1762.371337890625,
      967.15380859375,
      1772.94580078125,
      993.1143798828125,
      "2",
      16,
      1,
      0
    ],
    [
      1646.194580078125,
      967.15380859375,
      1656.76904296875,
      993.1143798828125,
      "3",
      16,
      2,
      0
    ],
    [
      1532.082275390625,
      967.15380859375,
      1542.65673828125,
      993.1143798828125,
      "4",
      16,
      3,
      0
    ],
    [
      1417.969970703125,
      967.15380859375,
      1428.54443359375,
      993.1143798828125,
      "5",
      16,
      4,
      0
    ],
    [
      1303.8575439453125,
      967.15380859375,
      1314.4320068359375,
      993.1143798828125,
      "6",
      16,
      5,
      0
    ],
    [
      1189.7452392578125,
      967.15380859375,
      1200.3197021484375,
      993.1143798828125,
      "7",
      16,
      6,
      0
    ],
    [
      1075.6329345703125,
      967.15380859375,
      1086.2073974609375,
      993.1143798828125,
      "8",
      16,
      7,
      0
    ],
    [
      961.5206298828125,
      967.15380859375,
      972.0950317382812,
      993.1143798828125,
      "9",
      16,
      8,
      0
    ],
    [
      842.1448974609375,
      967.15380859375,
      863.293701171875,
      993.1143798828125,
      "10",
      16,
      9,
      0
    ],
    [
      728.0325927734375,
      967.15380859375,
      749.181396484375,
      993.1143798828125,
      "11",
      16,
      10,
      0
    ],
    [
      613.9202880859375,
      967.15380859375,
      635.069091796875,
      993.1143798828125,
      "12",
      16,
      11,
      0
    ],
    [
      499.80792236328125,
      967.15380859375,
      520.9567260742188,
      993.1143798828125,
      "13",
      16,
      12,
      0
    ],
    [
      385.69561767578125,
      967.15380859375,
      406.84442138671875,
      993.1143798828125,
      "14",
      16,
      13,
      0
    ],
    [
      235.5478515625,
      967.15380859375,
      256.69671630859375,
      993.1143798828125,
      "15",
      16,
      14,
      0
    ],
    [
      1935.293701171875,
      1554.5262451171875,
      1971.441650390625,
      1571.6055908203125,
      "FIRST",
      17,
      0,
      0
    ],
    [
      1974.9200439453125,
      1554.5262451171875,
      2018.02490234375,
      1571.6055908203125,
      "FLOOR",
      17,
      0,
      1
    ],
    [
      1986.780517578125,
      1567.8612060546875,
      1996.1273193359375,
      1584.9405517578125,
      "0'",
      18,
      0,
      0
    ],
    [
      1999.605712890625,
      1567.8612060546875,
      2003.7723388671875,
      1584.9405517578125,
      "-",
      18,
      0,
      1
    ],
    [
      2007.250732421875,
      1567.8612060546875,
      2018.6494140625,
      1584.9405517578125,
      "0\"",
      18,
      0,
      2
    ],
    [
      1918.013671875,
      1440.4139404296875,
      1971.541259765625,
      1457.4932861328125,
      "SECOND",
      19,
      0,
      0
    ],
    [
      1975.01953125,
      1440.4139404296875,
      2018.12451171875,
      1457.4932861328125,
      "FLOOR",
      19,
      0,
      1
    ],
    [
      1979.828857421875,
      1453.7489013671875,
      1996.1324462890625,
      1470.8282470703125,
      "12'",
      20,
      0,
      0
    ],
    [
      1999.61083984375,
      1453.7489013671875,
      2003.7774658203125,
      1470.8282470703125,
      "-",
      20,
      0,
      1
    ],
    [
      2007.255859375,
      1453.7489013671875,
      2018.654541015625,
      1470.8282470703125,
      "8\"",
      20,
      0,
      2
    ],
    [
      1933.392578125,
      1353.3282470703125,
      1971.61767578125,
      1370.4075927734375,
      "THIRD",
      21,
      0,
      0
    ],
    [
      1975.095947265625,
      1353.3282470703125,
      2018.200927734375,
      1370.4075927734375,
      "FLOOR",
      21,
      0,
      1
    ],
    [
      1979.828857421875,
      1366.6632080078125,
      1996.1324462890625,
      1383.7425537109375,
      "22'",
      22,
      0,
      0
    ],
    [
      1999.61083984375,
      1366.6632080078125,
      2003.7774658203125,
      1383.7425537109375,
      "-",
      22,
      0,
      1
    ],
    [
      2007.255859375,
      1366.6632080078125,
      2018.654541015625,
      1383.7425537109375,
      "4\"",
      22,
      0,
      2
    ],
    [
      1919.5174560546875,
      1266.2425537109375,
      1971.643798828125,
      1283.3218994140625,
      "FOURTH",
      23,
      0,
      0
    ],
    [
      1975.1220703125,
      1266.2425537109375,
      2018.22705078125,
      1283.3218994140625,
      "FLOOR",
      23,
      0,
      1
    ],
    [
      1979.828857421875,
      1279.5775146484375,
      1996.1324462890625,
      1296.6568603515625,
      "32'",
      24,
      0,
      0
    ],
    [
      1999.61083984375,
      1279.5775146484375,
      2003.7774658203125,
      1296.6568603515625,
      "-",
      24,
      0,
      1
    ],
    [
      2007.255859375,
      1279.5775146484375,
      2018.654541015625,
      1296.6568603515625,
      "0\"",
      24,
      0,
      2
    ],
    [
      1936.0313720703125,
      1179.1568603515625,
      1971.478759765625,
      1196.2362060546875,
      "FIFTH",
      25,
      0,
      0
    ],
    [
      1974.95703125,
      1179.1568603515625,
      2018.06201171875,
      1196.2362060546875,
      "FLOOR",
      25,
      0,
      1
    ],
    [
      1979.828857421875,
      1192.49169921875,
      1996.1324462890625,
      1209.571044921875,
      "41'",
      26,
      0,
      0
    ],
    [
      1999.61083984375,
      1192.49169921875,
      2003.7774658203125,
      1209.571044921875,
      "-",
      26,
      0,
      1
    ],
    [
      2007.255859375,
      1192.49169921875,
      2018.654541015625,
      1209.571044921875,
      "8\"",
      26,
      0,
      2
    ],
    [
      1945.792236328125,
      1092.0711669921875,
      1981.940185546875,
      1109.1505126953125,
      "ROOF",
      27,
      0,
      0
    ],
    [
      1985.4185791015625,
      1092.0711669921875,
      2018.100830078125,
      1109.1505126953125,
      "PLAN",
      27,
      0,
      1
    ],
    [
      1979.828857421875,
      1105.406005859375,
      1996.1324462890625,
      1122.4853515625,
      "51'",
      28,
      0,
      0
    ],
    [
      1999.61083984375,
      1105.406005859375,
      2003.7774658203125,
      1122.4853515625,
      "-",
      28,
      0,
      1
    ],
    [
      2007.255859375,
      1105.406005859375,
      2018.654541015625,
      1122.4853515625,
      "4\"",
      28,
      0,
      2
    ],
    [
      1938.4715576171875,
      1065.0445556640625,
      1955.8511962890625,
      1082.1239013671875,
      "TO",
      29,
      0,
      0
    ],
    [
      1959.32958984375,
      1065.0445556640625,
      2017.7369384765625,
      1082.1239013671875,
      "PARAPET",
      29,
      0,
      1
    ],
    [
      1979.828857421875,
      1078.37939453125,
      1996.1324462890625,
      1095.458740234375,
      "54'",
      30,
      0,
      0
    ],
    [
      1999.61083984375,
      1078.37939453125,
      2003.7774658203125,
      1095.458740234375,
      "-",
      30,
      0,
      1
    ],
    [
      2007.255859375,
      1078.37939453125,
      2018.654541015625,
      1095.458740234375,
      "4\"",
      30,
      0,
      2
    ],
    [
      565.3025512695312,
      1147.66015625,
      569.6387939453125,
      1160.9066162109375,
      "8",
      31,
      0,
      0
    ],
    [
      679.4148559570312,
      1147.66015625,
      683.7510986328125,
      1160.9066162109375,
      "8",
      31,
      1,
      0
    ],
    [
      793.5271606445312,
      1147.66015625,
      797.8634033203125,
      1160.9066162109375,
      "8",
      31,
      2,
      0
    ],
    [
      907.6394653320312,
      1147.66015625,
      911.9757080078125,
      1160.9066162109375,
      "8",
      31,
      3,
      0
    ],
    [
      1021.7518310546875,
      1147.66015625,
      1026.088134765625,
      1160.9066162109375,
      "8",
      31,
      4,
      0
    ],
    [
      1135.8641357421875,
      1147.66015625,
      1140.200439453125,
      1160.9066162109375,
      "8",
      31,
      5,
      0
    ],
    [
      1249.9764404296875,
      1147.66015625,
      1254.312744140625,
      1160.9066162109375,
      "8",
      31,
      6,
      0
    ],
    [
      1363.6429443359375,
      1147.66015625,
      1367.979248046875,
      1160.9066162109375,
      "8",
      31,
      7,
      0
    ],
    [
      1477.82568359375,
      1147.66015625,
      1482.1619873046875,
      1160.9066162109375,
      "8",
      31,
      8,
      0
    ],
    [
      1592.4775390625,
      1147.66015625,
      1596.8138427734375,
      1160.9066162109375,
      "8",
      31,
      9,
      0
    ],
    [
      1707.4580078125,
      1147.66015625,
      1711.7943115234375,
      1160.9066162109375,
      "8",
      31,
      10,
      0
    ],
    [
      1821.5703125,
      1147.66015625,
      1825.9066162109375,
      1160.9066162109375,
      "8",
      31,
      11,
      0
    ],
    [
      565.3025512695312,
      1234.745849609375,
      569.6387939453125,
      1247.9923095703125,
      "8",
      32,
      0,
      0
    ],
    [
      679.4148559570312,
      1234.745849609375,
      683.7510986328125,
      1247.9923095703125,
      "8",
      32,
      1,
      0
    ],
    [
      793.5271606445312,
      1234.745849609375,
      797.8634033203125,
      1247.9923095703125,
      "8",
      32,
      2,
      0
    ],
    [
      907.6394653320312,
      1234.745849609375,
      911.9757080078125,
      1247.9923095703125,
      "8",
      32,
      3,
      0
    ],
    [
      1021.7518310546875,
      1234.745849609375,
      1026.088134765625,
      1247.9923095703125,
      "8",
      32,
      4,
      0
    ],
    [
      1135.8641357421875,
      1234.745849609375,
      1140.200439453125,
      1247.9923095703125,
      "8",
      32,
      5,
      0
    ],
    [
      1249.9764404296875,
      1234.745849609375,
      1254.312744140625,
      1247.9923095703125,
      "8",
      32,
      6,
      0
    ],
    [
      1363.6429443359375,
      1234.745849609375,
      1367.979248046875,
      1247.9923095703125,
      "8",
      32,
      7,
      0
    ],
    [
      1477.82568359375,
      1234.745849609375,
      1482.1619873046875,
      1247.9923095703125,
      "8",
      32,
      8,
      0
    ],
    [
      1592.4775390625,
      1234.745849609375,
      1596.8138427734375,
      1247.9923095703125,
      "8",
      32,
      9,
      0
    ],
    [
      1707.4580078125,
      1234.745849609375,
      1711.7943115234375,
      1247.9923095703125,
      "8",
      32,
      10,
      0
    ],
    [
      1821.5703125,
      1234.745849609375,
      1825.9066162109375,
      1247.9923095703125,
      "8",
      32,
      11,
      0
    ],
    [
      565.3025512695312,
      1321.83154296875,
      569.6387939453125,
      1335.0780029296875,
      "8",
      33,
      0,
      0
    ],
    [
      679.4148559570312,
      1321.83154296875,
      683.7510986328125,
      1335.0780029296875,
      "8",
      33,
      1,
      0
    ],
    [
      793.5271606445312,
      1321.83154296875,
      797.8634033203125,
      1335.0780029296875,
      "8",
      33,
      2,
      0
    ],
    [
      907.6394653320312,
      1321.83154296875,
      911.9757080078125,
      1335.0780029296875,
      "8",
      33,
      3,
      0
    ],
    [
      1021.7518310546875,
      1321.83154296875,
      1026.088134765625,
      1335.0780029296875,
      "8",
      33,
      4,
      0
    ],
    [
      1135.8641357421875,
      1321.83154296875,
      1140.200439453125,
      1335.0780029296875,
      "8",
      33,
      5,
      0
    ],
    [
      1249.9764404296875,
      1321.83154296875,
      1254.312744140625,
      1335.0780029296875,
      "8",
      33,
      6,
      0
    ],
    [
      1363.6429443359375,
      1321.83154296875,
      1367.979248046875,
      1335.0780029296875,
      "8",
      33,
      7,
      0
    ],
    [
      1477.82568359375,
      1321.83154296875,
      1482.1619873046875,
      1335.0780029296875,
      "8",
      33,
      8,
      0
    ],
    [
      1592.4775390625,
      1321.83154296875,
      1596.8138427734375,
      1335.0780029296875,
      "8",
      33,
      9,
      0
    ],
    [
      1707.4580078125,
      1321.83154296875,
      1711.7943115234375,
      1335.0780029296875,
      "8",
      33,
      10,
      0
    ],
    [
      1821.5703125,
      1321.83154296875,
      1825.9066162109375,
      1335.0780029296875,
      "8",
      33,
      11,
      0
    ],
    [
      565.3025512695312,
      1408.917236328125,
      569.6387939453125,
      1422.1636962890625,
      "8",
      34,
      0,
      0
    ],
    [
      679.4148559570312,
      1408.917236328125,
      683.7510986328125,
      1422.1636962890625,
      "8",
      34,
      1,
      0
    ],
    [
      793.5271606445312,
      1408.917236328125,
      797.8634033203125,
      1422.1636962890625,
      "8",
      34,
      2,
      0
    ],
    [
      907.6394653320312,
      1408.917236328125,
      911.9757080078125,
      1422.1636962890625,
      "8",
      34,
      3,
      0
    ],
    [
      1021.7518310546875,
      1408.917236328125,
      1026.088134765625,
      1422.1636962890625,
      "8",
      34,
      4,
      0
    ],
    [
      1135.8641357421875,
      1408.917236328125,
      1140.200439453125,
      1422.1636962890625,
      "8",
      34,
      5,
      0
    ],
    [
      1249.9764404296875,
      1408.917236328125,
      1254.312744140625,
      1422.1636962890625,
      "8",
      34,
      6,
      0
    ],
    [
      1363.6429443359375,
      1408.917236328125,
      1367.979248046875,
      1422.1636962890625,
      "8",
      34,
      7,
      0
    ],
    [
      1477.82568359375,
      1408.917236328125,
      1482.1619873046875,
      1422.1636962890625,
      "8",
      34,
      8,
      0
    ],
    [
      1592.4775390625,
      1408.917236328125,
      1596.8138427734375,
      1422.1636962890625,
      "8",
      34,
      9,
      0
    ],
    [
      1707.4580078125,
      1408.917236328125,
      1711.7943115234375,
      1422.1636962890625,
      "8",
      34,
      10,
      0
    ],
    [
      1821.5703125,
      1408.917236328125,
      1825.9066162109375,
      1422.1636962890625,
      "8",
      34,
      11,
      0
    ],
    [
      1361.69580078125,
      1523.029541015625,
      1366.0321044921875,
      1536.2760009765625,
      "8",
      35,
      0,
      0
    ],
    [
      1475.87841796875,
      1523.029541015625,
      1480.2147216796875,
      1536.2760009765625,
      "8",
      35,
      1,
      0
    ],
    [
      1590.5303955078125,
      1523.029541015625,
      1594.86669921875,
      1536.2760009765625,
      "8",
      35,
      2,
      0
    ],
    [
      1705.5107421875,
      1523.029541015625,
      1709.8470458984375,
      1536.2760009765625,
      "8",
      35,
      3,
      0
    ],
    [
      1819.623046875,
      1523.029541015625,
      1823.9593505859375,
      1536.2760009765625,
      "8",
      35,
      4,
      0
    ],
    [
      1020.2503051757812,
      1521.528076171875,
      1028.9228515625,
      1534.7745361328125,
      "10",
      35,
      5,
      0
    ],
    [
      298.64959716796875,
      1321.83154296875,
      309.0528259277344,
      1335.0780029296875,
      "EX",
      36,
      0,
      0
    ],
    [
      311.220947265625,
      1321.83154296875,
      313.8169860839844,
      1335.0780029296875,
      "-",
      36,
      0,
      1
    ],
    [
      315.98516845703125,
      1321.83154296875,
      320.3214416503906,
      1335.0780029296875,
      "2",
      36,
      0,
      2
    ],
    [
      891.798095703125,
      1090.1224365234375,
      902.2013549804688,
      1103.368896484375,
      "EX",
      37,
      0,
      0
    ],
    [
      904.3695068359375,
      1090.1224365234375,
      906.965576171875,
      1103.368896484375,
      "-",
      37,
      0,
      1
    ],
    [
      909.1336669921875,
      1090.1224365234375,
      913.4699096679688,
      1103.368896484375,
      "2",
      37,
      0,
      2
    ],
    [
      559.0689086914062,
      1521.528076171875,
      569.4721069335938,
      1534.7745361328125,
      "EX",
      38,
      0,
      0
    ],
    [
      571.6402587890625,
      1521.528076171875,
      574.236328125,
      1534.7745361328125,
      "-",
      38,
      0,
      1
    ],
    [
      576.4044799804688,
      1521.528076171875,
      580.74072265625,
      1534.7745361328125,
      "1",
      38,
      0,
      2
    ],
    [
      1126.6275634765625,
      1521.528076171875,
      1137.03076171875,
      1534.7745361328125,
      "EX",
      38,
      1,
      0
    ],
    [
      1139.1988525390625,
      1521.528076171875,
      1141.794921875,
      1534.7745361328125,
      "-",
      38,
      1,
      1
    ],
    [
      1143.963134765625,
      1521.528076171875,
      1148.2994384765625,
      1534.7745361328125,
      "1",
      38,
      1,
      2
    ],
    [
      1126.6275634765625,
      1457.71533203125,
      1137.03076171875,
      1470.9617919921875,
      "EX",
      39,
      0,
      0
    ],
    [
      1139.1988525390625,
      1457.71533203125,
      1141.794921875,
      1470.9617919921875,
      "-",
      39,
      0,
      1
    ],
    [
      1143.963134765625,
      1457.71533203125,
      1148.2994384765625,
      1470.9617919921875,
      "5",
      39,
      0,
      2
    ],
    [
      1126.6275634765625,
      1370.6295166015625,
      1137.03076171875,
      1383.8759765625,
      "EX",
      40,
      0,
      0
    ],
    [
      1139.1988525390625,
      1370.6295166015625,
      1141.794921875,
      1383.8759765625,
      "-",
      40,
      0,
      1
    ],
    [
      1143.963134765625,
      1370.6295166015625,
      1148.2994384765625,
      1383.8759765625,
      "5",
      40,
      0,
      2
    ],
    [
      1126.6275634765625,
      1283.5438232421875,
      1137.03076171875,
      1296.790283203125,
      "EX",
      41,
      0,
      0
    ],
    [
      1139.1988525390625,
      1283.5438232421875,
      1141.794921875,
      1296.790283203125,
      "-",
      41,
      0,
      1
    ],
    [
      1143.963134765625,
      1283.5438232421875,
      1148.2994384765625,
      1296.790283203125,
      "5",
      41,
      0,
      2
    ],
    [
      1126.6275634765625,
      1196.4581298828125,
      1137.03076171875,
      1209.70458984375,
      "EX",
      42,
      0,
      0
    ],
    [
      1139.1988525390625,
      1196.4581298828125,
      1141.794921875,
      1209.70458984375,
      "-",
      42,
      0,
      1
    ],
    [
      1143.963134765625,
      1196.4581298828125,
      1148.2994384765625,
      1209.70458984375,
      "5",
      42,
      0,
      2
    ],
    [
      1126.6275634765625,
      1109.3724365234375,
      1137.03076171875,
      1122.618896484375,
      "EX",
      43,
      0,
      0
    ],
    [
      1139.1988525390625,
      1109.3724365234375,
      1141.794921875,
      1122.618896484375,
      "-",
      43,
      0,
      1
    ],
    [
      1143.963134765625,
      1109.3724365234375,
      1148.2994384765625,
      1122.618896484375,
      "5",
      43,
      0,
      2
    ],
    [
      587.5969848632812,
      1457.71533203125,
      598.0001831054688,
      1470.9617919921875,
      "EX",
      44,
      0,
      0
    ],
    [
      600.1683349609375,
      1457.71533203125,
      602.764404296875,
      1470.9617919921875,
      "-",
      44,
      0,
      1
    ],
    [
      604.9325561523438,
      1457.71533203125,
      609.268798828125,
      1470.9617919921875,
      "5",
      44,
      0,
      2
    ],
    [
      587.5969848632812,
      1370.6295166015625,
      598.0001831054688,
      1383.8759765625,
      "EX",
      45,
      0,
      0
    ],
    [
      600.1683349609375,
      1370.6295166015625,
      602.764404296875,
      1383.8759765625,
      "-",
      45,
      0,
      1
    ],
    [
      604.9325561523438,
      1370.6295166015625,
      609.268798828125,
      1383.8759765625,
      "5",
      45,
      0,
      2
    ],
    [
      587.5969848632812,
      1283.5438232421875,
      598.0001831054688,
      1296.790283203125,
      "EX",
      46,
      0,
      0
    ],
    [
      600.1683349609375,
      1283.5438232421875,
      602.764404296875,
      1296.790283203125,
      "-",
      46,
      0,
      1
    ],
    [
      604.9325561523438,
      1283.5438232421875,
      609.268798828125,
      1296.790283203125,
      "5",
      46,
      0,
      2
    ],
    [
      587.5969848632812,
      1196.4581298828125,
      598.0001831054688,
      1209.70458984375,
      "EX",
      47,
      0,
      0
    ],
    [
      600.1683349609375,
      1196.4581298828125,
      602.764404296875,
      1209.70458984375,
      "-",
      47,
      0,
      1
    ],
    [
      604.9325561523438,
      1196.4581298828125,
      609.268798828125,
      1209.70458984375,
      "5",
      47,
      0,
      2
    ],
    [
      587.5969848632812,
      1109.3724365234375,
      598.0001831054688,
      1122.618896484375,
      "EX",
      48,
      0,
      0
    ],
    [
      600.1683349609375,
      1109.3724365234375,
      602.764404296875,
      1122.618896484375,
      "-",
      48,
      0,
      1
    ],
    [
      604.9325561523438,
      1109.3724365234375,
      609.268798828125,
      1122.618896484375,
      "5",
      48,
      0,
      2
    ],
    [
      958.170654296875,
      1242.253173828125,
      968.5738525390625,
      1255.4996337890625,
      "EX",
      49,
      0,
      0
    ],
    [
      970.7420043945312,
      1242.253173828125,
      973.3380737304688,
      1255.4996337890625,
      "-",
      49,
      0,
      1
    ],
    [
      975.5061645507812,
      1242.253173828125,
      979.8424072265625,
      1255.4996337890625,
      "1",
      49,
      0,
      2
    ],
    [
      1539.5657958984375,
      1297.1966552734375,
      1549.9691162109375,
      1310.443115234375,
      "EX",
      50,
      0,
      0
    ],
    [
      1552.13720703125,
      1297.1966552734375,
      1554.7332763671875,
      1310.443115234375,
      "-",
      50,
      0,
      1
    ],
    [
      1556.9013671875,
      1297.1966552734375,
      1561.2376708984375,
      1310.443115234375,
      "2",
      50,
      0,
      2
    ],
    [
      1411.9415283203125,
      1297.1966552734375,
      1422.3448486328125,
      1310.443115234375,
      "EX",
      50,
      1,
      0
    ],
    [
      1424.512939453125,
      1297.1966552734375,
      1427.1090087890625,
      1310.443115234375,
      "-",
      50,
      1,
      1
    ],
    [
      1429.277099609375,
      1297.1966552734375,
      1433.6134033203125,
      1310.443115234375,
      "3",
      50,
      1,
      2
    ],
    [
      1284.197265625,
      1297.1966552734375,
      1294.6005859375,
      1310.443115234375,
      "EX",
      50,
      2,
      0
    ],
    [
      1296.7685546875,
      1297.1966552734375,
      1299.3646240234375,
      1310.443115234375,
      "-",
      50,
      2,
      1
    ],
    [
      1301.5328369140625,
      1297.1966552734375,
      1305.869140625,
      1310.443115234375,
      "2",
      50,
      2,
      2
    ],
    [
      1699.253662109375,
      1457.71533203125,
      1709.656982421875,
      1470.9617919921875,
      "EX",
      51,
      0,
      0
    ],
    [
      1711.8250732421875,
      1457.71533203125,
      1714.421142578125,
      1470.9617919921875,
      "-",
      51,
      0,
      1
    ],
    [
      1716.5892333984375,
      1457.71533203125,
      1720.925537109375,
      1470.9617919921875,
      "5",
      51,
      0,
      2
    ],
    [
      1699.253662109375,
      1370.6295166015625,
      1709.656982421875,
      1383.8759765625,
      "EX",
      52,
      0,
      0
    ],
    [
      1711.8250732421875,
      1370.6295166015625,
      1714.421142578125,
      1383.8759765625,
      "-",
      52,
      0,
      1
    ],
    [
      1716.5892333984375,
      1370.6295166015625,
      1720.925537109375,
      1383.8759765625,
      "5",
      52,
      0,
      2
    ],
    [
      1699.253662109375,
      1283.5438232421875,
      1709.656982421875,
      1296.790283203125,
      "EX",
      53,
      0,
      0
    ],
    [
      1711.8250732421875,
      1283.5438232421875,
      1714.421142578125,
      1296.790283203125,
      "-",
      53,
      0,
      1
    ],
    [
      1716.5892333984375,
      1283.5438232421875,
      1720.925537109375,
      1296.790283203125,
      "5",
      53,
      0,
      2
    ],
    [
      1699.253662109375,
      1196.4581298828125,
      1709.656982421875,
      1209.70458984375,
      "EX",
      54,
      0,
      0
    ],
    [
      1711.8250732421875,
      1196.4581298828125,
      1714.421142578125,
      1209.70458984375,
      "-",
      54,
      0,
      1
    ],
    [
      1716.5892333984375,
      1196.4581298828125,
      1720.925537109375,
      1209.70458984375,
      "5",
      54,
      0,
      2
    ],
    [
      1699.253662109375,
      1109.3724365234375,
      1709.656982421875,
      1122.618896484375,
      "EX",
      55,
      0,
      0
    ],
    [
      1711.8250732421875,
      1109.3724365234375,
      1714.421142578125,
      1122.618896484375,
      "-",
      55,
      0,
      1
    ],
    [
      1716.5892333984375,
      1109.3724365234375,
      1720.925537109375,
      1122.618896484375,
      "5",
      55,
      0,
      2
    ],
    [
      1692.64892578125,
      1090.1224365234375,
      1703.0521240234375,
      1103.368896484375,
      "EX",
      56,
      0,
      0
    ],
    [
      1705.22021484375,
      1090.1224365234375,
      1707.8162841796875,
      1103.368896484375,
      "-",
      56,
      0,
      1
    ],
    [
      1709.984375,
      1090.1224365234375,
      1714.3206787109375,
      1103.368896484375,
      "2",
      56,
      0,
      2
    ],
    [
      1759.959716796875,
      1242.253173828125,
      1770.363037109375,
      1255.4996337890625,
      "EX",
      57,
      0,
      0
    ],
    [
      1772.5311279296875,
      1242.253173828125,
      1775.127197265625,
      1255.4996337890625,
      "-",
      57,
      0,
      1
    ],
    [
      1777.2952880859375,
      1242.253173828125,
      1781.631591796875,
      1255.4996337890625,
      "1",
      57,
      0,
      2
    ],
    [
      1380.47802734375,
      1043.169921875,
      1389.150634765625,
      1056.4163818359375,
      "19",
      58,
      0,
      0
    ],
    [
      1446.4046630859375,
      1043.169921875,
      1455.0772705078125,
      1056.4163818359375,
      "25",
      58,
      1,
      0
    ],
    [
      1549.9368896484375,
      1043.169921875,
      1558.6094970703125,
      1056.4163818359375,
      "18",
      58,
      2,
      0
    ],
    [
      1642.2281494140625,
      1043.169921875,
      1650.9007568359375,
      1056.4163818359375,
      "19",
      58,
      3,
      0
    ],
    [
      1757.3536376953125,
      1043.169921875,
      1766.0262451171875,
      1056.4163818359375,
      "19",
      58,
      4,
      0
    ],
    [
      1608.5205078125,
      1111.690673828125,
      1617.1929931640625,
      1124.9371337890625,
      "18",
      59,
      0,
      0
    ],
    [
      1608.5205078125,
      1198.7763671875,
      1617.1929931640625,
      1212.0228271484375,
      "18",
      60,
      0,
      0
    ],
    [
      1608.5205078125,
      1285.862060546875,
      1617.1929931640625,
      1299.1085205078125,
      "18",
      61,
      0,
      0
    ],
    [
      1608.5205078125,
      1372.94775390625,
      1617.1929931640625,
      1386.1942138671875,
      "18",
      62,
      0,
      0
    ],
    [
      1608.5205078125,
      1460.0335693359375,
      1617.1929931640625,
      1473.280029296875,
      "18",
      63,
      0,
      0
    ],
    [
      1089.63427734375,
      1020.572509765625,
      1098.3067626953125,
      1033.8189697265625,
      "24",
      64,
      0,
      0
    ],
    [
      1057.6483154296875,
      1020.572509765625,
      1066.3209228515625,
      1033.8189697265625,
      "19",
      64,
      1,
      0
    ],
    [
      773.3628540039062,
      1020.572509765625,
      782.0353393554688,
      1033.8189697265625,
      "19",
      64,
      2,
      0
    ],
    [
      1757.6705322265625,
      1539.5457763671875,
      1768.0738525390625,
      1552.792236328125,
      "EX",
      65,
      0,
      0
    ],
    [
      1770.241943359375,
      1539.5457763671875,
      1772.8380126953125,
      1552.792236328125,
      "-",
      65,
      0,
      1
    ],
    [
      1775.006103515625,
      1539.5457763671875,
      1779.3424072265625,
      1552.792236328125,
      "1",
      65,
      0,
      2
    ],
    [
      1204.565185546875,
      80.22163391113281,
      1400.809814453125,
      119.96124267578125,
      "ARCHITECTURAL",
      66,
      0,
      0
    ],
    [
      1407.314208984375,
      80.22163391113281,
      1533.4083251953125,
      119.96124267578125,
      "ELEMENTS",
      66,
      0,
      1
    ],
    [
      1331.6619873046875,
      139.6658477783203,
      1368.0557861328125,
      159.1870574951172,
      "CORE:",
      67,
      0,
      0
    ],
    [
      1371.2509765625,
      139.6658477783203,
      1396.1673583984375,
      159.1870574951172,
      "body",
      67,
      0,
      1
    ],
    [
      1331.6619873046875,
      156.2759552001953,
      1392.986328125,
      175.7971649169922,
      "Background",
      67,
      1,
      0
    ],
    [
      1396.181396484375,
      156.2759552001953,
      1409.5926513671875,
      175.7971649169922,
      "for",
      67,
      1,
      1
    ],
    [
      1412.787841796875,
      156.2759552001953,
      1453.0213623046875,
      175.7971649169922,
      "layering",
      67,
      1,
      2
    ],
    [
      1456.216552734375,
      156.2759552001953,
      1465.802001953125,
      175.7971649169922,
      "of",
      67,
      1,
      3
    ],
    [
      1468.9970703125,
      156.2759552001953,
      1480.4884033203125,
      175.7971649169922,
      "all",
      67,
      1,
      4
    ],
    [
      1483.68359375,
      156.2759552001953,
      1509.8753662109375,
      175.7971649169922,
      "other",
      67,
      1,
      5
    ],
    [
      1331.6619873046875,
      172.7921905517578,
      1378.271728515625,
      192.3134002685547,
      "materials",
      67,
      2,
      0
    ],
    [
      1331.6619873046875,
      187.24391174316406,
      1369.3310546875,
      206.76512145996094,
      "WRAP:",
      67,
      3,
      0
    ],
    [
      1372.526123046875,
      187.24391174316406,
      1408.289306640625,
      206.76512145996094,
      "Unified",
      67,
      3,
      1
    ],
    [
      1411.4844970703125,
      187.24391174316406,
      1452.36279296875,
      206.76512145996094,
      "element",
      67,
      3,
      2
    ],
    [
      1455.557861328125,
      187.24391174316406,
      1470.8890380859375,
      206.76512145996094,
      "set",
      67,
      3,
      3
    ],
    [
      1474.0841064453125,
      187.24391174316406,
      1503.4710693359375,
      206.76512145996094,
      "proud",
      67,
      3,
      4
    ],
    [
      1506.6661376953125,
      187.24391174316406,
      1527.3504638671875,
      206.76512145996094,
      "(12\"",
      67,
      3,
      5
    ],
    [
      1530.545654296875,
      187.24391174316406,
      1552.8836669921875,
      206.76512145996094,
      "min)",
      67,
      3,
      6
    ],
    [
      1331.6619873046875,
      203.85401916503906,
      1354.64453125,
      223.37522888183594,
      "from",
      67,
      4,
      0
    ],
    [
      1357.8397216796875,
      203.85401916503906,
      1373.8154296875,
      223.37522888183594,
      "the",
      67,
      4,
      1
    ],
    [
      1377.0106201171875,
      203.85401916503906,
      1410.209228515625,
      223.37522888183594,
      "CORE",
      67,
      4,
      2
    ],
    [
      1331.6619873046875,
      234.8219757080078,
      1360.404296875,
      254.3431854248047,
      "LINK:",
      68,
      0,
      0
    ],
    [
      1363.599365234375,
      234.8219757080078,
      1421.728515625,
      254.3431854248047,
      "Connection",
      68,
      0,
      1
    ],
    [
      1424.9237060546875,
      234.8219757080078,
      1453.666015625,
      254.3431854248047,
      "Piece",
      68,
      0,
      2
    ],
    [
      1456.8612060546875,
      234.8219757080078,
      1466.446533203125,
      254.3431854248047,
      "to",
      68,
      0,
      3
    ],
    [
      1469.6417236328125,
      234.8219757080078,
      1498.384033203125,
      254.3431854248047,
      "break",
      68,
      0,
      4
    ],
    [
      1501.5791015625,
      234.8219757080078,
      1514.3597412109375,
      254.3431854248047,
      "up",
      68,
      0,
      5
    ],
    [
      1517.554931640625,
      234.8219757080078,
      1543.1019287109375,
      254.3431854248047,
      "large",
      68,
      0,
      6
    ],
    [
      1331.6619873046875,
      251.4319610595703,
      1381.48095703125,
      270.95318603515625,
      "segments",
      68,
      1,
      0
    ],
    [
      1384.6761474609375,
      251.4319610595703,
      1394.2615966796875,
      270.95318603515625,
      "of",
      68,
      1,
      1
    ],
    [
      1397.4566650390625,
      251.4319610595703,
      1413.432373046875,
      270.95318603515625,
      "the",
      68,
      1,
      2
    ],
    [
      1416.6275634765625,
      251.4319610595703,
      1451.1014404296875,
      270.95318603515625,
      "WRAP",
      68,
      1,
      3
    ],
    [
      1331.6619873046875,
      282.4000549316406,
      1365.519287109375,
      301.9212646484375,
      "KEEP:",
      69,
      0,
      0
    ],
    [
      1368.7144775390625,
      282.4000549316406,
      1424.2930908203125,
      301.9212646484375,
      "foreground",
      69,
      0,
      1
    ],
    [
      1427.48828125,
      282.4000549316406,
      1468.3665771484375,
      301.9212646484375,
      "element",
      69,
      0,
      2
    ],
    [
      1471.5616455078125,
      282.4000549316406,
      1481.1470947265625,
      301.9212646484375,
      "of",
      69,
      0,
      3
    ],
    [
      1484.34228515625,
      282.4000549316406,
      1532.8719482421875,
      301.9212646484375,
      "BEACON",
      69,
      0,
      4
    ],
    [
      1331.6619873046875,
      299.0101623535156,
      1365.519287109375,
      318.5313720703125,
      "stands",
      69,
      1,
      0
    ],
    [
      1368.7144775390625,
      299.0101623535156,
      1393.616943359375,
      318.5313720703125,
      "most",
      69,
      1,
      1
    ],
    [
      1396.81201171875,
      299.0101623535156,
      1426.198974609375,
      318.5313720703125,
      "proud",
      69,
      1,
      2
    ],
    [
      1429.3941650390625,
      299.0101623535156,
      1438.9796142578125,
      318.5313720703125,
      "of",
      69,
      1,
      3
    ],
    [
      1442.1746826171875,
      299.0101623535156,
      1453.666015625,
      318.5313720703125,
      "all",
      69,
      1,
      4
    ],
    [
      1460.0562744140625,
      299.0101623535156,
      1499.6593017578125,
      318.5313720703125,
      "building",
      69,
      1,
      5
    ],
    [
      1502.8543701171875,
      299.0101623535156,
      1549.4783935546875,
      318.5313720703125,
      "surfaces.",
      69,
      1,
      6
    ],
    [
      1331.6619873046875,
      315.6202697753906,
      1366.7945556640625,
      335.1414794921875,
      "Placed",
      69,
      2,
      0
    ],
    [
      1369.9896240234375,
      315.6202697753906,
      1382.770263671875,
      335.1414794921875,
      "on",
      69,
      2,
      1
    ],
    [
      1385.9654541015625,
      315.6202697753906,
      1424.2650146484375,
      335.1414794921875,
      "primary",
      69,
      2,
      2
    ],
    [
      1427.460205078125,
      315.6202697753906,
      1467.0631103515625,
      335.1414794921875,
      "building",
      69,
      2,
      3
    ],
    [
      1470.25830078125,
      315.6202697753906,
      1495.805419921875,
      335.1414794921875,
      "entry",
      69,
      2,
      4
    ],
    [
      1499.0006103515625,
      315.6202697753906,
      1544.993896484375,
      335.1414794921875,
      "elevation",
      69,
      2,
      5
    ],
    [
      1548.18896484375,
      315.6202697753906,
      1557.1297607421875,
      335.1414794921875,
      "in",
      69,
      2,
      6
    ],
    [
      1331.6619873046875,
      332.2302551269531,
      1389.7911376953125,
      351.75146484375,
      "conjunction",
      69,
      3,
      0
    ],
    [
      1392.986328125,
      332.2302551269531,
      1413.4183349609375,
      351.75146484375,
      "with",
      69,
      3,
      1
    ],
    [
      1416.613525390625,
      332.2302551269531,
      1432.5892333984375,
      351.75146484375,
      "the",
      69,
      3,
      2
    ],
    [
      1435.784423828125,
      332.2302551269531,
      1461.9761962890625,
      351.75146484375,
      "porte",
      69,
      3,
      3
    ],
    [
      1465.17138671875,
      332.2302551269531,
      1506.049560546875,
      351.75146484375,
      "cochere",
      69,
      3,
      4
    ],
    [
      1509.2447509765625,
      332.2302551269531,
      1528.41552734375,
      351.75146484375,
      "and",
      69,
      3,
      5
    ],
    [
      1531.6107177734375,
      332.2302551269531,
      1552.0428466796875,
      351.75146484375,
      "with",
      69,
      3,
      6
    ],
    [
      1331.6619873046875,
      348.84039306640625,
      1356.564453125,
      368.3616027832031,
      "clear",
      69,
      4,
      0
    ],
    [
      1359.7596435546875,
      348.84039306640625,
      1399.33447265625,
      368.3616027832031,
      "visibility",
      69,
      4,
      1
    ],
    [
      1402.5296630859375,
      348.84039306640625,
      1425.5123291015625,
      368.3616027832031,
      "from",
      69,
      4,
      2
    ],
    [
      1428.7073974609375,
      348.84039306640625,
      1444.68310546875,
      368.3616027832031,
      "the",
      69,
      4,
      3
    ],
    [
      1447.8782958984375,
      348.84039306640625,
      1490.0457763671875,
      368.3616027832031,
      "frontage",
      69,
      4,
      4
    ],
    [
      1493.240966796875,
      348.84039306640625,
      1519.4327392578125,
      368.3616027832031,
      "road.",
      69,
      4,
      5
    ],
    [
      1331.6619873046875,
      365.4505310058594,
      1373.184814453125,
      384.97174072265625,
      "Extends",
      69,
      5,
      0
    ],
    [
      1376.3800048828125,
      365.4505310058594,
      1389.1605224609375,
      384.97174072265625,
      "up",
      69,
      5,
      1
    ],
    [
      1392.355712890625,
      365.4505310058594,
      1430.052734375,
      384.97174072265625,
      "beyond",
      69,
      5,
      2
    ],
    [
      1433.2479248046875,
      365.4505310058594,
      1449.2236328125,
      384.97174072265625,
      "the",
      69,
      5,
      3
    ],
    [
      1452.4188232421875,
      365.4505310058594,
      1490.087890625,
      384.97174072265625,
      "WRAP.",
      69,
      5,
      4
    ],
    [
      1493.282958984375,
      365.4505310058594,
      1554.6072998046875,
      384.97174072265625,
      "Background",
      69,
      5,
      5
    ],
    [
      1331.6619873046875,
      382.0605163574219,
      1345.0732421875,
      401.58172607421875,
      "for",
      69,
      6,
      0
    ],
    [
      1348.268310546875,
      382.0605163574219,
      1386.5679931640625,
      401.58172607421875,
      "primary",
      69,
      6,
      1
    ],
    [
      1389.76318359375,
      382.0605163574219,
      1429.3660888671875,
      401.58172607421875,
      "building",
      69,
      6,
      2
    ],
    [
      1432.561279296875,
      382.0605163574219,
      1456.8331298828125,
      401.58172607421875,
      "sign.",
      69,
      6,
      3
    ],
    [
      1331.6619873046875,
      413.0285949707031,
      1378.9024658203125,
      432.5498046875,
      "ACCENT",
      70,
      0,
      0
    ],
    [
      1382.09765625,
      413.0285949707031,
      1417.2161865234375,
      432.5498046875,
      "BAND:",
      70,
      0,
      1
    ],
    [
      1420.4112548828125,
      413.0285949707031,
      1475.9759521484375,
      432.5498046875,
      "articulation",
      70,
      0,
      2
    ],
    [
      1331.6619873046875,
      429.6385803222656,
      1383.3868408203125,
      449.1597900390625,
      "Horizontal",
      70,
      1,
      0
    ],
    [
      1386.58203125,
      429.6385803222656,
      1401.2684326171875,
      449.1597900390625,
      "3D",
      70,
      1,
      1
    ],
    [
      1404.463623046875,
      429.6385803222656,
      1430.0247802734375,
      449.1597900390625,
      "band",
      70,
      1,
      2
    ],
    [
      1433.2198486328125,
      429.6385803222656,
      1462.6068115234375,
      449.1597900390625,
      "proud",
      70,
      1,
      3
    ],
    [
      1465.802001953125,
      429.6385803222656,
      1475.387451171875,
      449.1597900390625,
      "of",
      70,
      1,
      4
    ],
    [
      1478.58251953125,
      429.6385803222656,
      1514.9764404296875,
      449.1597900390625,
      "CORE.",
      70,
      1,
      5
    ],
    [
      1331.6619873046875,
      446.24871826171875,
      1378.9305419921875,
      465.7699279785156,
      "Sufficient",
      70,
      2,
      0
    ],
    [
      1382.1256103515625,
      446.24871826171875,
      1410.8818359375,
      465.7699279785156,
      "depth",
      70,
      2,
      1
    ],
    [
      1414.0770263671875,
      446.24871826171875,
      1428.37109375,
      465.7699279785156,
      "(2\"",
      70,
      2,
      2
    ],
    [
      1431.5662841796875,
      446.24871826171875,
      1453.904296875,
      465.7699279785156,
      "min)",
      70,
      2,
      3
    ],
    [
      1457.099365234375,
      446.24871826171875,
      1466.684814453125,
      465.7699279785156,
      "to",
      70,
      2,
      4
    ],
    [
      1469.8800048828125,
      446.24871826171875,
      1501.8173828125,
      465.7699279785156,
      "create",
      70,
      2,
      5
    ],
    [
      1505.0125732421875,
      446.24871826171875,
      1540.7757568359375,
      465.7699279785156,
      "distinct",
      70,
      2,
      6
    ],
    [
      1331.6619873046875,
      462.8588562011719,
      1371.264892578125,
      482.38006591796875,
      "shadow",
      70,
      3,
      0
    ],
    [
      1374.4600830078125,
      462.8588562011719,
      1395.536865234375,
      482.38006591796875,
      "line.",
      70,
      3,
      1
    ],
    [
      1398.73193359375,
      462.8588562011719,
      1413.4183349609375,
      482.38006591796875,
      "No",
      70,
      3,
      2
    ],
    [
      1416.613525390625,
      462.8588562011719,
      1448.5369873046875,
      482.38006591796875,
      "visible",
      70,
      3,
      3
    ],
    [
      1451.732177734375,
      462.8588562011719,
      1481.7496337890625,
      482.38006591796875,
      "joints.",
      70,
      3,
      4
    ],
    [
      1331.6619873046875,
      493.8268127441406,
      1390.4078369140625,
      513.3480224609375,
      "SUPPORT:",
      71,
      0,
      0
    ],
    [
      1393.6029052734375,
      493.8268127441406,
      1418.5194091796875,
      513.3480224609375,
      "base",
      71,
      0,
      1
    ],
    [
      1331.6619873046875,
      524.7947387695312,
      1363.5853271484375,
      544.3159790039062,
      "PORT",
      72,
      0,
      0
    ],
    [
      1366.780517578125,
      524.7947387695312,
      1424.237060546875,
      544.3159790039062,
      "COCHERE",
      72,
      0,
      1
    ],
    [
      1331.6619873046875,
      555.7626953125,
      1383.3868408203125,
      575.283935546875,
      "BEACON:",
      73,
      0,
      0
    ],
    [
      1386.58203125,
      555.7626953125,
      1422.975830078125,
      575.283935546875,
      "vertical",
      73,
      0,
      1
    ],
    [
      1426.1708984375,
      555.7626953125,
      1470.244384765625,
      575.283935546875,
      "element.",
      73,
      0,
      2
    ],
    [
      1473.439453125,
      555.7626953125,
      1490.6905517578125,
      575.283935546875,
      "Set",
      73,
      0,
      3
    ],
    [
      1493.8856201171875,
      555.7626953125,
      1525.1923828125,
      575.283935546875,
      "above",
      73,
      0,
      4
    ],
    [
      1528.3875732421875,
      555.7626953125,
      1547.558349609375,
      575.283935546875,
      "and",
      73,
      0,
      5
    ],
    [
      1331.6619873046875,
      572.372802734375,
      1355.933837890625,
      591.89404296875,
      "back",
      73,
      1,
      0
    ],
    [
      1359.1290283203125,
      572.372802734375,
      1368.0697021484375,
      591.89404296875,
      "in",
      73,
      1,
      1
    ],
    [
      1371.264892578125,
      572.372802734375,
      1399.3765869140625,
      591.89404296875,
      "plane",
      73,
      1,
      2
    ],
    [
      1402.57177734375,
      572.372802734375,
      1425.5543212890625,
      591.89404296875,
      "from",
      73,
      1,
      3
    ],
    [
      1428.74951171875,
      572.372802734375,
      1444.7252197265625,
      591.89404296875,
      "the",
      73,
      1,
      4
    ],
    [
      1447.92041015625,
      572.372802734375,
      1481.7777099609375,
      591.89404296875,
      "KEEP,",
      73,
      1,
      5
    ],
    [
      1484.972900390625,
      572.372802734375,
      1525.220458984375,
      591.89404296875,
      "extends",
      73,
      1,
      6
    ],
    [
      1528.41552734375,
      572.372802734375,
      1538.0009765625,
      591.89404296875,
      "to",
      73,
      1,
      7
    ],
    [
      1541.1961669921875,
      572.372802734375,
      1557.171875,
      591.89404296875,
      "the",
      73,
      1,
      8
    ],
    [
      1331.6619873046875,
      588.9829711914062,
      1370.6343994140625,
      608.5042114257812,
      "ground.",
      73,
      2,
      0
    ],
    [
      1373.8294677734375,
      588.9829711914062,
      1429.3941650390625,
      608.5042114257812,
      "Composed",
      73,
      2,
      1
    ],
    [
      1432.5892333984375,
      588.9829711914062,
      1442.1748046875,
      608.5042114257812,
      "of",
      73,
      2,
      2
    ],
    [
      1445.369873046875,
      588.9829711914062,
      1463.25146484375,
      608.5042114257812,
      "two",
      73,
      2,
      3
    ],
    [
      1466.446533203125,
      588.9829711914062,
      1507.3248291015625,
      608.5042114257812,
      "element",
      73,
      2,
      4
    ],
    [
      1512.1429443359375,
      588.9829711914062,
      1517.8885498046875,
      608.5042114257812,
      "s",
      73,
      2,
      5
    ],
    [
      1521.083740234375,
      588.9829711914062,
      1546.0001220703125,
      608.5042114257812,
      "each",
      73,
      2,
      6
    ],
    [
      1549.1953125,
      588.9829711914062,
      1558.1361083984375,
      608.5042114257812,
      "in",
      73,
      2,
      7
    ],
    [
      1331.6619873046875,
      606.1617431640625,
      1370.2698974609375,
      625.6829833984375,
      "Brand's",
      73,
      3,
      0
    ],
    [
      1373.465087890625,
      606.1617431640625,
      1402.837890625,
      625.6829833984375,
      "iconic",
      73,
      3,
      1
    ],
    [
      1406.0330810546875,
      606.1617431640625,
      1435.4200439453125,
      625.6829833984375,
      "green",
      73,
      3,
      2
    ],
    [
      1438.615234375,
      606.1617431640625,
      1467.343505859375,
      625.6829833984375,
      "(PMS",
      73,
      3,
      3
    ],
    [
      1470.53857421875,
      606.1617431640625,
      1489.70947265625,
      625.6829833984375,
      "383",
      73,
      3,
      4
    ],
    [
      1492.9046630859375,
      606.1617431640625,
      1501.2008056640625,
      625.6829833984375,
      "C",
      73,
      3,
      5
    ],
    [
      1504.3958740234375,
      606.1617431640625,
      1507.591064453125,
      625.6829833984375,
      "/",
      73,
      3,
      6
    ],
    [
      1510.7862548828125,
      606.1617431640625,
      1528.023193359375,
      625.6829833984375,
      "BM",
      73,
      3,
      7
    ],
    [
      1531.21826171875,
      606.1617431640625,
      1550.38916015625,
      625.6829833984375,
      "398",
      73,
      3,
      8
    ],
    [
      1331.6619873046875,
      623.340576171875,
      1362.3101806640625,
      642.86181640625,
      "flower",
      73,
      4,
      0
    ],
    [
      1365.5052490234375,
      623.340576171875,
      1403.8189697265625,
      642.86181640625,
      "power):",
      73,
      4,
      1
    ],
    [
      1331.6619873046875,
      652.5885009765625,
      1380.205810546875,
      672.1097412109375,
      "REVEAL:",
      74,
      0,
      0
    ],
    [
      1383.40087890625,
      652.5885009765625,
      1419.794677734375,
      672.1097412109375,
      "vertical",
      74,
      0,
      1
    ],
    [
      1422.9898681640625,
      652.5885009765625,
      1463.8680419921875,
      672.1097412109375,
      "element",
      74,
      0,
      2
    ],
    [
      1467.063232421875,
      652.5885009765625,
      1516.896240234375,
      672.1097412109375,
      "extending",
      74,
      0,
      3
    ],
    [
      1520.0914306640625,
      652.5885009765625,
      1559.063720703125,
      672.1097412109375,
      "through",
      74,
      0,
      4
    ],
    [
      1331.6619873046875,
      669.1986083984375,
      1347.6376953125,
      688.7198486328125,
      "the",
      74,
      1,
      0
    ],
    [
      1350.832763671875,
      669.1986083984375,
      1384.690185546875,
      688.7198486328125,
      "KEEP.",
      74,
      1,
      1
    ],
    [
      1387.88525390625,
      669.1986083984375,
      1426.8436279296875,
      688.7198486328125,
      "Highest",
      74,
      1,
      2
    ],
    [
      1430.038818359375,
      669.1986083984375,
      1461.3455810546875,
      688.7198486328125,
      "above",
      74,
      1,
      3
    ],
    [
      1464.540771484375,
      669.1986083984375,
      1479.2271728515625,
      688.7198486328125,
      "all.",
      74,
      1,
      4
    ],
    [
      1331.6619873046875,
      699.0404052734375,
      1367.4251708984375,
      718.5616455078125,
      "BEAM:",
      75,
      0,
      0
    ],
    [
      1370.6202392578125,
      699.0404052734375,
      1407.01416015625,
      718.5616455078125,
      "vertical",
      75,
      0,
      1
    ],
    [
      1410.209228515625,
      699.0404052734375,
      1444.052490234375,
      718.5616455078125,
      "recess",
      75,
      0,
      2
    ],
    [
      1447.2476806640625,
      699.0404052734375,
      1470.2303466796875,
      718.5616455078125,
      "from",
      75,
      0,
      3
    ],
    [
      1473.4254150390625,
      699.0404052734375,
      1489.401123046875,
      718.5616455078125,
      "the",
      75,
      0,
      4
    ],
    [
      1492.5963134765625,
      699.0404052734375,
      1528.37353515625,
      718.5616455078125,
      "ground",
      75,
      0,
      5
    ],
    [
      1531.5687255859375,
      699.0404052734375,
      1541.154052734375,
      718.5616455078125,
      "to",
      75,
      0,
      6
    ],
    [
      1544.3492431640625,
      699.0404052734375,
      1560.324951171875,
      718.5616455078125,
      "the",
      75,
      0,
      7
    ],
    [
      1331.6619873046875,
      715.6505126953125,
      1380.205810546875,
      735.1717529296875,
      "REVEAL.",
      75,
      1,
      0
    ],
    [
      1290.50244140625,
      139.34347534179688,
      1316.049560546875,
      159.18699645996094,
      "EX-1",
      76,
      0,
      0
    ],
    [
      1290.50244140625,
      186.92153930664062,
      1316.049560546875,
      206.7650604248047,
      "EX-2",
      77,
      0,
      0
    ],
    [
      1290.50244140625,
      234.49960327148438,
      1316.049560546875,
      254.34312438964844,
      "EX-3",
      78,
      0,
      0
    ],
    [
      1290.50244140625,
      282.0776672363281,
      1316.049560546875,
      301.92120361328125,
      "EX-4",
      79,
      0,
      0
    ],
    [
      1290.50244140625,
      412.70623779296875,
      1316.049560546875,
      432.5497741699219,
      "EX-5",
      80,
      0,
      0
    ],
    [
      1290.50244140625,
      493.5044250488281,
      1316.049560546875,
      513.3479614257812,
      "EX-6",
      81,
      0,
      0
    ],
    [
      1290.50244140625,
      524.4723510742188,
      1316.049560546875,
      544.31591796875,
      "EX-7",
      82,
      0,
      0
    ],
    [
      1290.50244140625,
      555.4403076171875,
      1316.049560546875,
      575.2838745117188,
      "EX-8",
      83,
      0,
      0
    ],
    [
      1570.08544921875,
      80.22163391113281,
      1750.7822265625,
      119.96124267578125,
      "PROTOTYPICAL",
      84,
      0,
      0
    ],
    [
      1757.2867431640625,
      80.22163391113281,
      1889.8851318359375,
      119.96124267578125,
      "MATERIALS",
      84,
      0,
      1
    ],
    [
      1561.0765380859375,
      139.34353637695312,
      1616.6273193359375,
      159.1870574951172,
      "SUPPORT",
      85,
      0,
      0
    ],
    [
      1561.0765380859375,
      156.2759552001953,
      1616.6273193359375,
      175.7971649169922,
      "Materiality:",
      85,
      1,
      0
    ],
    [
      1561.0765380859375,
      206.10621643066406,
      1591.7247314453125,
      225.62742614746094,
      "Color:",
      86,
      0,
      0
    ],
    [
      1561.0765380859375,
      222.71632385253906,
      1603.2301025390625,
      242.23753356933594,
      "Texture:",
      86,
      1,
      0
    ],
    [
      1561.0765380859375,
      255.93641662597656,
      1607.7005615234375,
      275.4576416015625,
      "Contrast:",
      87,
      0,
      0
    ],
    [
      1561.0765380859375,
      305.4444885253906,
      1594.2752685546875,
      325.28802490234375,
      "CORE",
      88,
      0,
      0
    ],
    [
      1561.0765380859375,
      322.3769226074219,
      1616.6273193359375,
      341.89813232421875,
      "Materiality:",
      88,
      1,
      0
    ],
    [
      1561.0765380859375,
      388.8172912597656,
      1591.7247314453125,
      408.3385009765625,
      "Color:",
      89,
      0,
      0
    ],
    [
      1561.0765380859375,
      422.0373840332031,
      1603.2301025390625,
      441.55859375,
      "Texture:",
      90,
      0,
      0
    ],
    [
      1561.0765380859375,
      438.64752197265625,
      1607.7005615234375,
      458.1687316894531,
      "Contrast:",
      90,
      1,
      0
    ],
    [
      1561.0765380859375,
      504.7655334472656,
      1596.18115234375,
      524.6090698242188,
      "WRAP",
      91,
      0,
      0
    ],
    [
      1561.0765380859375,
      521.697998046875,
      1616.6273193359375,
      541.21923828125,
      "Materiality:",
      91,
      1,
      0
    ],
    [
      1561.0765380859375,
      571.5281982421875,
      1591.7247314453125,
      591.0494384765625,
      "Color:",
      92,
      0,
      0
    ],
    [
      1561.0765380859375,
      588.1383056640625,
      1603.2301025390625,
      607.6595458984375,
      "Texture:",
      92,
      1,
      0
    ],
    [
      1561.0765380859375,
      604.7484741210938,
      1607.7005615234375,
      624.2697143554688,
      "Contrast:",
      92,
      2,
      0
    ],
    [
      1561.0765380859375,
      670.8665161132812,
      1587.8848876953125,
      690.7100830078125,
      "LINK",
      93,
      0,
      0
    ],
    [
      1591.080078125,
      670.8665161132812,
      1599.376220703125,
      690.7100830078125,
      "&",
      93,
      0,
      1
    ],
    [
      1602.5714111328125,
      670.8665161132812,
      1633.8642578125,
      690.7100830078125,
      "KEEP",
      93,
      0,
      2
    ],
    [
      1561.0765380859375,
      687.7989501953125,
      1616.6273193359375,
      707.3201904296875,
      "Materiality:",
      93,
      1,
      0
    ],
    [
      1561.0765380859375,
      754.2392578125,
      1591.7247314453125,
      773.760498046875,
      "Color:",
      94,
      0,
      0
    ],
    [
      1561.0765380859375,
      787.4594116210938,
      1603.2301025390625,
      806.9806518554688,
      "Texture:",
      95,
      0,
      0
    ],
    [
      1561.0765380859375,
      804.0695190429688,
      1607.7005615234375,
      823.5907592773438,
      "Contrast:",
      95,
      1,
      0
    ],
    [
      1973.062744140625,
      151.44912719726562,
      2020.9337158203125,
      171.2926483154297,
      "ACCENT",
      96,
      0,
      0
    ],
    [
      1973.062744140625,
      168.05923461914062,
      2006.247314453125,
      187.9027557373047,
      "BAND",
      96,
      1,
      0
    ],
    [
      1973.062744140625,
      184.9916534423828,
      2028.6134033203125,
      204.5128631591797,
      "Materiality:",
      96,
      2,
      0
    ],
    [
      1973.062744140625,
      218.2117462158203,
      2003.7108154296875,
      237.7329559326172,
      "Color:",
      97,
      0,
      0
    ],
    [
      1973.062744140625,
      251.4318389892578,
      2015.2161865234375,
      270.95306396484375,
      "Texture:",
      98,
      0,
      0
    ],
    [
      1973.062744140625,
      268.0419616699219,
      2019.6864013671875,
      287.56317138671875,
      "Contrast:",
      98,
      1,
      0
    ],
    [
      1973.062744140625,
      334.1601257324219,
      2012.651611328125,
      354.003662109375,
      "PORTE",
      99,
      0,
      0
    ],
    [
      1973.062744140625,
      350.7701110839844,
      2030.51904296875,
      370.6136474609375,
      "COCHERE",
      99,
      1,
      0
    ],
    [
      1973.062744140625,
      367.70257568359375,
      2028.6134033203125,
      387.2237854003906,
      "Materiality:",
      99,
      2,
      0
    ],
    [
      1973.062744140625,
      400.9228210449219,
      2003.7108154296875,
      420.44403076171875,
      "Color:",
      100,
      0,
      0
    ],
    [
      1973.062744140625,
      434.1429138183594,
      2015.2161865234375,
      453.66412353515625,
      "Texture:",
      101,
      0,
      0
    ],
    [
      1641.2916259765625,
      156.27577209472656,
      1682.1697998046875,
      175.79698181152344,
      "Building",
      102,
      0,
      0
    ],
    [
      1685.364990234375,
      156.27577209472656,
      1726.229248046875,
      175.79698181152344,
      "material",
      102,
      0,
      1
    ],
    [
      1729.42431640625,
      156.27577209472656,
      1776.0621337890625,
      175.79698181152344,
      "authentic",
      102,
      0,
      2
    ],
    [
      1779.25732421875,
      156.27577209472656,
      1798.42822265625,
      175.79698181152344,
      "and",
      102,
      0,
      3
    ],
    [
      1801.623291015625,
      156.27577209472656,
      1856.557373046875,
      175.79698181152344,
      "substantial",
      102,
      0,
      4
    ],
    [
      1859.75244140625,
      156.27577209472656,
      1900.6165771484375,
      175.79698181152344,
      "material",
      102,
      0,
      5
    ],
    [
      1903.811767578125,
      156.27577209472656,
      1924.2437744140625,
      175.79698181152344,
      "with",
      102,
      0,
      6
    ],
    [
      1927.43896484375,
      156.27577209472656,
      1954.9058837890625,
      175.79698181152344,
      "clean",
      102,
      0,
      7
    ],
    [
      1641.2916259765625,
      172.88587951660156,
      1665.549560546875,
      192.40708923339844,
      "crisp",
      102,
      1,
      0
    ],
    [
      1668.74462890625,
      172.88587951660156,
      1692.371826171875,
      192.40708923339844,
      "lines",
      102,
      1,
      1
    ],
    [
      1695.567138671875,
      172.88587951660156,
      1719.8389892578125,
      192.40708923339844,
      "such",
      102,
      1,
      2
    ],
    [
      1723.0341796875,
      172.88587951660156,
      1735.1700439453125,
      192.40708923339844,
      "as",
      102,
      1,
      3
    ],
    [
      1738.365234375,
      172.88587951660156,
      1756.246826171875,
      192.40708923339844,
      "tile,",
      102,
      1,
      4
    ],
    [
      1759.44189453125,
      172.88587951660156,
      1774.7730712890625,
      192.40708923339844,
      "cut",
      102,
      1,
      5
    ],
    [
      1777.9681396484375,
      172.88587951660156,
      1809.2750244140625,
      192.40708923339844,
      "stone,",
      102,
      1,
      6
    ],
    [
      1812.469970703125,
      172.88587951660156,
      1833.5467529296875,
      192.40708923339844,
      "cast",
      102,
      1,
      7
    ],
    [
      1836.741943359375,
      172.88587951660156,
      1868.0487060546875,
      192.40708923339844,
      "stone,",
      102,
      1,
      8
    ],
    [
      1871.24365234375,
      172.88587951660156,
      1924.2576904296875,
      192.40708923339844,
      "decorative",
      102,
      1,
      9
    ],
    [
      1641.2916259765625,
      189.49598693847656,
      1685.3509521484375,
      209.01719665527344,
      "masonry",
      102,
      2,
      0
    ],
    [
      1688.546142578125,
      189.49598693847656,
      1712.8179931640625,
      209.01719665527344,
      "units",
      102,
      2,
      1
    ],
    [
      1716.01318359375,
      189.49598693847656,
      1745.3721923828125,
      209.01719665527344,
      "(cmu)",
      102,
      2,
      2
    ],
    [
      1748.5672607421875,
      189.49598693847656,
      1758.7833251953125,
      209.01719665527344,
      "or",
      102,
      2,
      3
    ],
    [
      1761.9783935546875,
      189.49598693847656,
      1786.236328125,
      209.01719665527344,
      "brick",
      102,
      2,
      4
    ],
    [
      1641.2916259765625,
      206.10597229003906,
      1666.208251953125,
      225.62718200683594,
      "Light",
      102,
      3,
      0
    ],
    [
      1669.4033203125,
      206.10597229003906,
      1678.9886474609375,
      225.62718200683594,
      "to",
      102,
      3,
      1
    ],
    [
      1682.183837890625,
      206.10597229003906,
      1723.0479736328125,
      225.62718200683594,
      "Medium",
      102,
      3,
      2
    ],
    [
      1726.2431640625,
      206.10597229003906,
      1792.0379638671875,
      225.62718200683594,
      "value,natural",
      102,
      3,
      3
    ],
    [
      1795.2330322265625,
      206.10597229003906,
      1836.7557373046875,
      225.62718200683594,
      "inherent",
      102,
      3,
      4
    ],
    [
      1839.950927734375,
      206.10597229003906,
      1848.8917236328125,
      225.62718200683594,
      "in",
      102,
      3,
      5
    ],
    [
      1852.0867919921875,
      206.10597229003906,
      1868.0623779296875,
      225.62718200683594,
      "the",
      102,
      3,
      6
    ],
    [
      1871.257568359375,
      206.10597229003906,
      1912.1217041015625,
      225.62718200683594,
      "material",
      102,
      3,
      7
    ],
    [
      1641.2916259765625,
      222.71607971191406,
      1720.4976806640625,
      242.23728942871094,
      "Sandstone-like,",
      102,
      4,
      0
    ],
    [
      1723.6927490234375,
      222.71607971191406,
      1759.469970703125,
      242.23728942871094,
      "ground",
      102,
      4,
      1
    ],
    [
      1762.6650390625,
      222.71607971191406,
      1787.5816650390625,
      242.23728942871094,
      "face,",
      102,
      4,
      2
    ],
    [
      1790.7767333984375,
      222.71607971191406,
      1815.6932373046875,
      242.23728942871094,
      "bush",
      102,
      4,
      3
    ],
    [
      1818.888427734375,
      222.71607971191406,
      1873.8082275390625,
      242.23728942871094,
      "hammered",
      102,
      4,
      4
    ],
    [
      1877.00341796875,
      222.71607971191406,
      1887.2193603515625,
      242.23728942871094,
      "or",
      102,
      4,
      5
    ],
    [
      1890.41455078125,
      222.71607971191406,
      1928.0975341796875,
      242.23728942871094,
      "smooth",
      102,
      4,
      6
    ],
    [
      1641.2916259765625,
      239.32618713378906,
      1664.9188232421875,
      258.847412109375,
      "High",
      102,
      5,
      0
    ],
    [
      1668.114013671875,
      239.32618713378906,
      1705.797119140625,
      258.847412109375,
      "textural",
      102,
      5,
      1
    ],
    [
      1708.9921875,
      239.32618713378906,
      1749.8704833984375,
      258.847412109375,
      "contrast",
      102,
      5,
      2
    ],
    [
      1753.065673828125,
      239.32618713378906,
      1762.6510009765625,
      258.847412109375,
      "to",
      102,
      5,
      3
    ],
    [
      1765.84619140625,
      239.32618713378906,
      1800.320068359375,
      258.847412109375,
      "WRAP",
      102,
      5,
      4
    ],
    [
      1803.5152587890625,
      239.32618713378906,
      1822.68603515625,
      258.847412109375,
      "and",
      102,
      5,
      5
    ],
    [
      1825.881103515625,
      239.32618713378906,
      1873.1214599609375,
      258.847412109375,
      "ACCENT",
      102,
      5,
      6
    ],
    [
      1876.316650390625,
      239.32618713378906,
      1911.4351806640625,
      258.847412109375,
      "BAND.",
      102,
      5,
      7
    ],
    [
      1641.2916259765625,
      255.93617248535156,
      1682.1558837890625,
      275.4573974609375,
      "Medium",
      102,
      6,
      0
    ],
    [
      1685.3509521484375,
      255.93617248535156,
      1710.2535400390625,
      275.4573974609375,
      "color",
      102,
      6,
      1
    ],
    [
      1713.4486083984375,
      255.93617248535156,
      1754.326904296875,
      275.4573974609375,
      "contrast",
      102,
      6,
      2
    ],
    [
      1757.52197265625,
      255.93617248535156,
      1767.107421875,
      275.4573974609375,
      "to",
      102,
      6,
      3
    ],
    [
      1770.302490234375,
      255.93617248535156,
      1781.7939453125,
      275.4573974609375,
      "all",
      102,
      6,
      4
    ],
    [
      1784.989013671875,
      255.93617248535156,
      1811.1807861328125,
      275.4573974609375,
      "other",
      102,
      6,
      5
    ],
    [
      1814.3758544921875,
      255.93617248535156,
      1864.19482421875,
      275.4573974609375,
      "elements.",
      102,
      6,
      6
    ],
    [
      1867.389892578125,
      255.93617248535156,
      1891.01708984375,
      275.4573974609375,
      "High",
      102,
      6,
      7
    ],
    [
      1894.212158203125,
      255.93617248535156,
      1935.076416015625,
      275.4573974609375,
      "material",
      102,
      6,
      8
    ],
    [
      1641.2916259765625,
      272.5462951660156,
      1682.169921875,
      292.0675048828125,
      "contrast",
      102,
      7,
      0
    ],
    [
      1685.364990234375,
      272.5462951660156,
      1694.950439453125,
      292.0675048828125,
      "to",
      102,
      7,
      1
    ],
    [
      1698.1455078125,
      272.5462951660156,
      1709.636962890625,
      292.0675048828125,
      "all",
      102,
      7,
      2
    ],
    [
      1712.83203125,
      272.5462951660156,
      1739.0238037109375,
      292.0675048828125,
      "other",
      102,
      7,
      3
    ],
    [
      1742.2188720703125,
      272.5462951660156,
      1792.0379638671875,
      292.0675048828125,
      "elements.",
      102,
      7,
      4
    ],
    [
      1641.2916259765625,
      322.3766784667969,
      1682.1697998046875,
      341.89788818359375,
      "Building",
      103,
      0,
      0
    ],
    [
      1685.364990234375,
      322.3766784667969,
      1726.229248046875,
      341.89788818359375,
      "material",
      103,
      0,
      1
    ],
    [
      1729.42431640625,
      322.3766784667969,
      1749.8564453125,
      341.89788818359375,
      "with",
      103,
      0,
      2
    ],
    [
      1753.051513671875,
      322.3766784667969,
      1784.989013671875,
      341.89788818359375,
      "strong",
      103,
      0,
      3
    ],
    [
      1788.18408203125,
      322.3766784667969,
      1852.044921875,
      341.89788818359375,
      "directionality",
      103,
      0,
      4
    ],
    [
      1855.2401123046875,
      322.3766784667969,
      1874.410888671875,
      341.89788818359375,
      "and",
      103,
      0,
      5
    ],
    [
      1877.60595703125,
      322.3766784667969,
      1899.3272705078125,
      341.89788818359375,
      "high",
      103,
      0,
      6
    ],
    [
      1641.2916259765625,
      338.9866638183594,
      1666.1942138671875,
      358.50787353515625,
      "relief",
      103,
      1,
      0
    ],
    [
      1669.3892822265625,
      338.9866638183594,
      1678.9747314453125,
      358.50787353515625,
      "to",
      103,
      1,
      1
    ],
    [
      1682.1697998046875,
      338.9866638183594,
      1714.1072998046875,
      358.50787353515625,
      "create",
      103,
      1,
      2
    ],
    [
      1717.3023681640625,
      338.9866638183594,
      1748.6092529296875,
      358.50787353515625,
      "shade",
      103,
      1,
      3
    ],
    [
      1751.8043212890625,
      338.9866638183594,
      1770.9752197265625,
      358.50787353515625,
      "and",
      103,
      1,
      4
    ],
    [
      1774.17041015625,
      338.9866638183594,
      1813.7733154296875,
      358.50787353515625,
      "shadow",
      103,
      1,
      5
    ],
    [
      1816.968505859375,
      338.9866638183594,
      1841.2403564453125,
      358.50787353515625,
      "such",
      103,
      1,
      6
    ],
    [
      1844.4354248046875,
      338.9866638183594,
      1856.5712890625,
      358.50787353515625,
      "as",
      103,
      1,
      7
    ],
    [
      1859.7664794921875,
      338.9866638183594,
      1901.2891845703125,
      358.50787353515625,
      "textured",
      103,
      1,
      8
    ],
    [
      1904.484375,
      338.9866638183594,
      1933.2266845703125,
      358.50787353515625,
      "EIFS,",
      103,
      1,
      9
    ],
    [
      1641.2916259765625,
      355.5968017578125,
      1677.6995849609375,
      375.1180114746094,
      "stucco,",
      103,
      2,
      0
    ],
    [
      1680.8946533203125,
      355.5968017578125,
      1705.1524658203125,
      375.1180114746094,
      "brick",
      103,
      2,
      1
    ],
    [
      1708.34765625,
      355.5968017578125,
      1735.814697265625,
      375.1180114746094,
      "wood",
      103,
      2,
      2
    ],
    [
      1739.009765625,
      355.5968017578125,
      1774.1424560546875,
      375.1180114746094,
      "Siding,",
      103,
      2,
      3
    ],
    [
      1777.3375244140625,
      355.5968017578125,
      1815.0206298828125,
      375.1180114746094,
      "cement",
      103,
      2,
      4
    ],
    [
      1818.2156982421875,
      355.5968017578125,
      1840.5677490234375,
      375.1180114746094,
      "fiber",
      103,
      2,
      5
    ],
    [
      1843.7626953125,
      355.5968017578125,
      1873.1495361328125,
      375.1180114746094,
      "board",
      103,
      2,
      6
    ],
    [
      1876.3447265625,
      355.5968017578125,
      1886.5606689453125,
      375.1180114746094,
      "or",
      103,
      2,
      7
    ],
    [
      1889.755859375,
      355.5968017578125,
      1944.6895751953125,
      375.1180114746094,
      "corrugated",
      103,
      2,
      8
    ],
    [
      1641.2916259765625,
      372.2069396972656,
      1669.3892822265625,
      391.7281494140625,
      "metal",
      103,
      3,
      0
    ],
    [
      1641.2916259765625,
      388.81707763671875,
      1682.1558837890625,
      408.3382873535156,
      "Medium",
      103,
      4,
      0
    ],
    [
      1685.3509521484375,
      388.81707763671875,
      1716.01318359375,
      408.3382873535156,
      "value,",
      103,
      4,
      1
    ],
    [
      1719.208251953125,
      388.81707763671875,
      1758.811279296875,
      408.3382873535156,
      "40-60%",
      103,
      4,
      2
    ],
    [
      1762.00634765625,
      388.81707763671875,
      1792.6685791015625,
      408.3382873535156,
      "value,",
      103,
      4,
      3
    ],
    [
      1795.86376953125,
      388.81707763671875,
      1822.055419921875,
      408.3382873535156,
      "earth",
      103,
      4,
      4
    ],
    [
      1825.25048828125,
      388.81707763671875,
      1894.8988037109375,
      408.3382873535156,
      "toned,painted",
      103,
      4,
      5
    ],
    [
      1898.093994140625,
      388.81707763671875,
      1908.3099365234375,
      408.3382873535156,
      "or",
      103,
      4,
      6
    ],
    [
      1911.505126953125,
      388.81707763671875,
      1946.637451171875,
      408.3382873535156,
      "natural",
      103,
      4,
      7
    ],
    [
      1641.2916259765625,
      405.4272155761719,
      1694.9644775390625,
      424.94842529296875,
      "depending",
      103,
      5,
      0
    ],
    [
      1698.15966796875,
      405.4272155761719,
      1710.940185546875,
      424.94842529296875,
      "on",
      103,
      5,
      1
    ],
    [
      1714.13525390625,
      405.4272155761719,
      1754.99951171875,
      424.94842529296875,
      "material",
      103,
      5,
      2
    ],
    [
      1641.2916259765625,
      422.0372009277344,
      1682.1558837890625,
      441.55841064453125,
      "Medium",
      103,
      6,
      0
    ],
    [
      1685.3509521484375,
      422.0372009277344,
      1694.9364013671875,
      441.55841064453125,
      "to",
      103,
      6,
      1
    ],
    [
      1698.131591796875,
      422.0372009277344,
      1732.6195068359375,
      441.55841064453125,
      "coarse",
      103,
      6,
      2
    ],
    [
      1735.814697265625,
      422.0372009277344,
      1770.9471435546875,
      441.55841064453125,
      "texture",
      103,
      6,
      3
    ],
    [
      1641.2916259765625,
      438.6473388671875,
      1664.9188232421875,
      458.1685485839844,
      "High",
      103,
      7,
      0
    ],
    [
      1668.114013671875,
      438.6473388671875,
      1705.797119140625,
      458.1685485839844,
      "textural",
      103,
      7,
      1
    ],
    [
      1708.9921875,
      438.6473388671875,
      1749.8704833984375,
      458.1685485839844,
      "contrast",
      103,
      7,
      2
    ],
    [
      1753.065673828125,
      438.6473388671875,
      1762.6510009765625,
      458.1685485839844,
      "to",
      103,
      7,
      3
    ],
    [
      1765.84619140625,
      438.6473388671875,
      1800.320068359375,
      458.1685485839844,
      "WRAP",
      103,
      7,
      4
    ],
    [
      1803.5152587890625,
      438.6473388671875,
      1822.68603515625,
      458.1685485839844,
      "and",
      103,
      7,
      5
    ],
    [
      1825.881103515625,
      438.6473388671875,
      1873.1214599609375,
      458.1685485839844,
      "ACCENT",
      103,
      7,
      6
    ],
    [
      1876.316650390625,
      438.6473388671875,
      1911.4351806640625,
      458.1685485839844,
      "BAND.",
      103,
      7,
      7
    ],
    [
      1641.2916259765625,
      455.2574768066406,
      1682.1558837890625,
      474.7786865234375,
      "Medium",
      103,
      8,
      0
    ],
    [
      1685.3509521484375,
      455.2574768066406,
      1694.9364013671875,
      474.7786865234375,
      "to",
      103,
      8,
      1
    ],
    [
      1698.131591796875,
      455.2574768066406,
      1721.7587890625,
      474.7786865234375,
      "High",
      103,
      8,
      2
    ],
    [
      1724.953857421875,
      455.2574768066406,
      1734.539306640625,
      474.7786865234375,
      "to",
      103,
      8,
      3
    ],
    [
      1737.7344970703125,
      455.2574768066406,
      1772.2083740234375,
      474.7786865234375,
      "WRAP",
      103,
      8,
      4
    ],
    [
      1775.403564453125,
      455.2574768066406,
      1794.5743408203125,
      474.7786865234375,
      "and",
      103,
      8,
      5
    ],
    [
      1797.76953125,
      455.2574768066406,
      1845.0098876953125,
      474.7786865234375,
      "ACCENT",
      103,
      8,
      6
    ],
    [
      1848.205078125,
      455.2574768066406,
      1883.3236083984375,
      474.7786865234375,
      "BAND.",
      103,
      8,
      7
    ],
    [
      1886.518798828125,
      455.2574768066406,
      1907.595458984375,
      474.7786865234375,
      "Low",
      103,
      8,
      8
    ],
    [
      1910.79052734375,
      455.2574768066406,
      1920.3758544921875,
      474.7786865234375,
      "to",
      103,
      8,
      9
    ],
    [
      1641.2916259765625,
      471.86761474609375,
      1682.1558837890625,
      491.3888244628906,
      "medium",
      103,
      9,
      0
    ],
    [
      1685.3509521484375,
      471.86761474609375,
      1726.2152099609375,
      491.3888244628906,
      "material",
      103,
      9,
      1
    ],
    [
      1729.4102783203125,
      471.86761474609375,
      1770.28857421875,
      491.3888244628906,
      "contrast",
      103,
      9,
      2
    ],
    [
      1773.483642578125,
      471.86761474609375,
      1783.069091796875,
      491.3888244628906,
      "to",
      103,
      9,
      3
    ],
    [
      1786.26416015625,
      471.86761474609375,
      1820.7381591796875,
      491.3888244628906,
      "WRAP",
      103,
      9,
      4
    ],
    [
      1823.933349609375,
      471.86761474609375,
      1831.598876953125,
      491.3888244628906,
      "&",
      103,
      9,
      5
    ],
    [
      1834.7939453125,
      471.86761474609375,
      1882.0343017578125,
      491.3888244628906,
      "ACCENT",
      103,
      9,
      6
    ],
    [
      1885.2294921875,
      471.86761474609375,
      1917.15283203125,
      491.3888244628906,
      "BAND",
      103,
      9,
      7
    ],
    [
      1641.2916259765625,
      521.6978149414062,
      1682.1697998046875,
      541.2190551757812,
      "Building",
      104,
      0,
      0
    ],
    [
      1685.364990234375,
      521.6978149414062,
      1726.229248046875,
      541.2190551757812,
      "material",
      104,
      0,
      1
    ],
    [
      1729.42431640625,
      521.6978149414062,
      1749.8564453125,
      541.2190551757812,
      "with",
      104,
      0,
      2
    ],
    [
      1753.051513671875,
      521.6978149414062,
      1759.4417724609375,
      541.2190551757812,
      "a",
      104,
      0,
      3
    ],
    [
      1762.636962890625,
      521.6978149414062,
      1802.2119140625,
      541.2190551757812,
      "minimal",
      104,
      0,
      4
    ],
    [
      1805.406982421875,
      521.6978149414062,
      1843.7347412109375,
      541.2190551757812,
      "amount",
      104,
      0,
      5
    ],
    [
      1846.9296875,
      521.6978149414062,
      1856.5152587890625,
      541.2190551757812,
      "of",
      104,
      0,
      6
    ],
    [
      1859.710205078125,
      521.6978149414062,
      1886.5325927734375,
      541.2190551757812,
      "joints",
      104,
      0,
      7
    ],
    [
      1889.727783203125,
      521.6978149414062,
      1908.8985595703125,
      541.2190551757812,
      "and",
      104,
      0,
      8
    ],
    [
      1641.2916259765625,
      538.3079833984375,
      1702.615966796875,
      557.8292236328125,
      "connections",
      104,
      1,
      0
    ],
    [
      1705.8111572265625,
      538.3079833984375,
      1724.9820556640625,
      557.8292236328125,
      "and",
      104,
      1,
      1
    ],
    [
      1728.1771240234375,
      538.3079833984375,
      1734.5673828125,
      557.8292236328125,
      "a",
      104,
      1,
      2
    ],
    [
      1737.7625732421875,
      538.3079833984375,
      1775.4456787109375,
      557.8292236328125,
      "smooth",
      104,
      1,
      3
    ],
    [
      1778.6407470703125,
      538.3079833984375,
      1805.463134765625,
      557.8292236328125,
      "finish",
      104,
      1,
      4
    ],
    [
      1808.6583251953125,
      538.3079833984375,
      1832.93017578125,
      557.8292236328125,
      "such",
      104,
      1,
      5
    ],
    [
      1836.125244140625,
      538.3079833984375,
      1848.26123046875,
      557.8292236328125,
      "as",
      104,
      1,
      6
    ],
    [
      1851.456298828125,
      538.3079833984375,
      1880.1986083984375,
      557.8292236328125,
      "EIFS,",
      104,
      1,
      7
    ],
    [
      1883.393798828125,
      538.3079833984375,
      1916.6063232421875,
      557.8292236328125,
      "stucco",
      104,
      1,
      8
    ],
    [
      1919.801513671875,
      538.3079833984375,
      1930.017578125,
      557.8292236328125,
      "or",
      104,
      1,
      9
    ],
    [
      1641.2916259765625,
      554.9180908203125,
      1669.3892822265625,
      574.4393310546875,
      "metal",
      104,
      2,
      0
    ],
    [
      1672.58447265625,
      554.9180908203125,
      1706.441650390625,
      574.4393310546875,
      "panels",
      104,
      2,
      1
    ],
    [
      1641.2916259765625,
      571.528076171875,
      1666.208251953125,
      591.04931640625,
      "Light",
      104,
      3,
      0
    ],
    [
      1669.4033203125,
      571.528076171875,
      1678.9886474609375,
      591.04931640625,
      "to",
      104,
      3,
      1
    ],
    [
      1682.183837890625,
      571.528076171875,
      1723.0479736328125,
      591.04931640625,
      "medium",
      104,
      3,
      2
    ],
    [
      1726.2431640625,
      571.528076171875,
      1756.9053955078125,
      591.04931640625,
      "value,",
      104,
      3,
      3
    ],
    [
      1760.1004638671875,
      571.528076171875,
      1797.7974853515625,
      591.04931640625,
      "painted",
      104,
      3,
      4
    ],
    [
      1641.2916259765625,
      588.13818359375,
      1680.8946533203125,
      607.659423828125,
      "Smooth",
      104,
      4,
      0
    ],
    [
      1684.0897216796875,
      588.13818359375,
      1694.3057861328125,
      607.659423828125,
      "or",
      104,
      4,
      1
    ],
    [
      1697.5009765625,
      588.13818359375,
      1719.8529052734375,
      607.659423828125,
      "Fine",
      104,
      4,
      2
    ],
    [
      1723.048095703125,
      588.13818359375,
      1749.8704833984375,
      607.659423828125,
      "finish",
      104,
      4,
      3
    ],
    [
      1641.2916259765625,
      604.7483520507812,
      1662.368408203125,
      624.2695922851562,
      "Low",
      104,
      5,
      0
    ],
    [
      1665.5634765625,
      604.7483520507812,
      1703.24658203125,
      624.2695922851562,
      "textural",
      104,
      5,
      1
    ],
    [
      1706.4417724609375,
      604.7483520507812,
      1747.320068359375,
      624.2695922851562,
      "contrast",
      104,
      5,
      2
    ],
    [
      1750.51513671875,
      604.7483520507812,
      1760.1004638671875,
      624.2695922851562,
      "to",
      104,
      5,
      3
    ],
    [
      1763.295654296875,
      604.7483520507812,
      1822.0416259765625,
      624.2695922851562,
      "SUPPORT.",
      104,
      5,
      4
    ],
    [
      1825.236572265625,
      604.7483520507812,
      1866.1007080078125,
      624.2695922851562,
      "Medium",
      104,
      5,
      5
    ],
    [
      1869.2958984375,
      604.7483520507812,
      1878.8812255859375,
      624.2695922851562,
      "to",
      104,
      5,
      6
    ],
    [
      1882.076416015625,
      604.7483520507812,
      1903.7977294921875,
      624.2695922851562,
      "high",
      104,
      5,
      7
    ],
    [
      1906.992919921875,
      604.7483520507812,
      1944.67578125,
      624.2695922851562,
      "textural",
      104,
      5,
      8
    ],
    [
      1641.2916259765625,
      621.3584594726562,
      1682.169921875,
      640.8796997070312,
      "contrast",
      104,
      6,
      0
    ],
    [
      1685.364990234375,
      621.3584594726562,
      1694.950439453125,
      640.8796997070312,
      "to",
      104,
      6,
      1
    ],
    [
      1698.1455078125,
      621.3584594726562,
      1734.5394287109375,
      640.8796997070312,
      "CORE,",
      104,
      6,
      2
    ],
    [
      1737.7344970703125,
      621.3584594726562,
      1758.811279296875,
      640.8796997070312,
      "Low",
      104,
      6,
      3
    ],
    [
      1762.00634765625,
      621.3584594726562,
      1771.591796875,
      640.8796997070312,
      "to",
      104,
      6,
      4
    ],
    [
      1774.7869873046875,
      621.3584594726562,
      1798.4141845703125,
      640.8796997070312,
      "High",
      104,
      6,
      5
    ],
    [
      1801.609375,
      621.3584594726562,
      1842.487548828125,
      640.8796997070312,
      "contrast",
      104,
      6,
      6
    ],
    [
      1845.6826171875,
      621.3584594726562,
      1855.2679443359375,
      640.8796997070312,
      "to",
      104,
      6,
      7
    ],
    [
      1858.463134765625,
      621.3584594726562,
      1914.013671875,
      640.8796997070312,
      "SUPPORT",
      104,
      6,
      8
    ],
    [
      1917.2088623046875,
      621.3584594726562,
      1936.379638671875,
      640.8796997070312,
      "and",
      104,
      6,
      9
    ],
    [
      1641.2916259765625,
      637.9684448242188,
      1688.5321044921875,
      657.4896850585938,
      "ACCENT",
      104,
      7,
      0
    ],
    [
      1691.727294921875,
      637.9684448242188,
      1726.845947265625,
      657.4896850585938,
      "BAND.",
      104,
      7,
      1
    ],
    [
      1730.041015625,
      637.9684448242188,
      1751.1177978515625,
      657.4896850585938,
      "Low",
      104,
      7,
      2
    ],
    [
      1754.31298828125,
      637.9684448242188,
      1763.8983154296875,
      657.4896850585938,
      "to",
      104,
      7,
      3
    ],
    [
      1767.093505859375,
      637.9684448242188,
      1790.720703125,
      657.4896850585938,
      "High",
      104,
      7,
      4
    ],
    [
      1793.9158935546875,
      637.9684448242188,
      1834.780029296875,
      657.4896850585938,
      "material",
      104,
      7,
      5
    ],
    [
      1837.97509765625,
      637.9684448242188,
      1878.8533935546875,
      657.4896850585938,
      "contrast",
      104,
      7,
      6
    ],
    [
      1882.04833984375,
      637.9684448242188,
      1891.6337890625,
      657.4896850585938,
      "to",
      104,
      7,
      7
    ],
    [
      1894.828857421875,
      637.9684448242188,
      1928.027587890625,
      657.4896850585938,
      "CORE",
      104,
      7,
      8
    ],
    [
      1641.2916259765625,
      687.798828125,
      1682.1697998046875,
      707.320068359375,
      "Building",
      105,
      0,
      0
    ],
    [
      1685.364990234375,
      687.798828125,
      1726.229248046875,
      707.320068359375,
      "material",
      105,
      0,
      1
    ],
    [
      1729.42431640625,
      687.798828125,
      1749.8564453125,
      707.320068359375,
      "with",
      105,
      0,
      2
    ],
    [
      1753.051513671875,
      687.798828125,
      1759.4417724609375,
      707.320068359375,
      "a",
      105,
      0,
      3
    ],
    [
      1762.636962890625,
      687.798828125,
      1794.5743408203125,
      707.320068359375,
      "strong",
      105,
      0,
      4
    ],
    [
      1797.76953125,
      687.798828125,
      1847.5885009765625,
      707.320068359375,
      "horizontal",
      105,
      0,
      5
    ],
    [
      1850.78369140625,
      687.798828125,
      1894.2122802734375,
      707.320068359375,
      "direction",
      105,
      0,
      6
    ],
    [
      1897.407470703125,
      687.798828125,
      1916.5782470703125,
      707.320068359375,
      "and",
      105,
      0,
      7
    ],
    [
      1919.7733154296875,
      687.798828125,
      1941.49462890625,
      707.320068359375,
      "high",
      105,
      0,
      8
    ],
    [
      1641.2916259765625,
      704.4088134765625,
      1666.1942138671875,
      723.9300537109375,
      "relief",
      105,
      1,
      0
    ],
    [
      1669.3892822265625,
      704.4088134765625,
      1678.9747314453125,
      723.9300537109375,
      "to",
      105,
      1,
      1
    ],
    [
      1682.1697998046875,
      704.4088134765625,
      1714.1072998046875,
      723.9300537109375,
      "create",
      105,
      1,
      2
    ],
    [
      1717.3023681640625,
      704.4088134765625,
      1748.6092529296875,
      723.9300537109375,
      "shade",
      105,
      1,
      3
    ],
    [
      1751.8043212890625,
      704.4088134765625,
      1770.9752197265625,
      723.9300537109375,
      "and",
      105,
      1,
      4
    ],
    [
      1774.17041015625,
      704.4088134765625,
      1816.968505859375,
      723.9300537109375,
      "shadow.",
      105,
      1,
      5
    ],
    [
      1820.16357421875,
      704.4088134765625,
      1859.7664794921875,
      723.9300537109375,
      "Smooth",
      105,
      1,
      6
    ],
    [
      1862.9615478515625,
      704.4088134765625,
      1889.783935546875,
      723.9300537109375,
      "finish",
      105,
      1,
      7
    ],
    [
      1892.97900390625,
      704.4088134765625,
      1937.0384521484375,
      723.9300537109375,
      "material:",
      105,
      1,
      8
    ],
    [
      1641.2916259765625,
      721.0189208984375,
      1666.8387451171875,
      740.5401611328125,
      "EIFS",
      105,
      2,
      0
    ],
    [
      1670.033935546875,
      721.0189208984375,
      1689.2047119140625,
      740.5401611328125,
      "and",
      105,
      2,
      1
    ],
    [
      1692.39990234375,
      721.0189208984375,
      1728.807861328125,
      740.5401611328125,
      "stucco.",
      105,
      2,
      2
    ],
    [
      1732.0029296875,
      721.0189208984375,
      1765.8602294921875,
      740.5401611328125,
      "Strong",
      105,
      2,
      3
    ],
    [
      1769.055419921875,
      721.0189208984375,
      1818.8743896484375,
      740.5401611328125,
      "horizontal",
      105,
      2,
      4
    ],
    [
      1822.069580078125,
      721.0189208984375,
      1871.87451171875,
      740.5401611328125,
      "materials:",
      105,
      2,
      5
    ],
    [
      1875.069580078125,
      721.0189208984375,
      1902.5225830078125,
      740.5401611328125,
      "brick,",
      105,
      2,
      6
    ],
    [
      1905.7177734375,
      721.0189208984375,
      1933.1846923828125,
      740.5401611328125,
      "wood",
      105,
      2,
      7
    ],
    [
      1641.2916259765625,
      737.6290283203125,
      1678.9747314453125,
      757.1502685546875,
      "cement",
      105,
      3,
      0
    ],
    [
      1682.169921875,
      737.6290283203125,
      1704.5218505859375,
      757.1502685546875,
      "fiber",
      105,
      3,
      1
    ],
    [
      1707.717041015625,
      737.6290283203125,
      1737.1038818359375,
      757.1502685546875,
      "board",
      105,
      3,
      2
    ],
    [
      1740.299072265625,
      737.6290283203125,
      1750.51513671875,
      757.1502685546875,
      "or",
      105,
      3,
      3
    ],
    [
      1753.710205078125,
      737.6290283203125,
      1781.807861328125,
      757.1502685546875,
      "metal",
      105,
      3,
      4
    ],
    [
      1641.2916259765625,
      754.2391967773438,
      1682.1558837890625,
      773.7604370117188,
      "Medium",
      105,
      4,
      0
    ],
    [
      1685.3509521484375,
      754.2391967773438,
      1694.9364013671875,
      773.7604370117188,
      "to",
      105,
      4,
      1
    ],
    [
      1698.131591796875,
      754.2391967773438,
      1722.389404296875,
      773.7604370117188,
      "Dark",
      105,
      4,
      2
    ],
    [
      1725.5845947265625,
      754.2391967773438,
      1756.246826171875,
      773.7604370117188,
      "value,",
      105,
      4,
      3
    ],
    [
      1759.44189453125,
      754.2391967773438,
      1797.138916015625,
      773.7604370117188,
      "painted",
      105,
      4,
      4
    ],
    [
      1800.3341064453125,
      754.2391967773438,
      1810.5501708984375,
      773.7604370117188,
      "or",
      105,
      4,
      5
    ],
    [
      1813.7452392578125,
      754.2391967773438,
      1848.877685546875,
      773.7604370117188,
      "natural",
      105,
      4,
      6
    ],
    [
      1852.07275390625,
      754.2391967773438,
      1905.7454833984375,
      773.7604370117188,
      "depending",
      105,
      4,
      7
    ],
    [
      1641.2916259765625,
      770.8493041992188,
      1654.0721435546875,
      790.3705444335938,
      "on",
      105,
      5,
      0
    ],
    [
      1657.267333984375,
      770.8493041992188,
      1698.131591796875,
      790.3705444335938,
      "material",
      105,
      5,
      1
    ],
    [
      1641.2916259765625,
      787.4592895507812,
      1680.8946533203125,
      806.9805297851562,
      "Smooth",
      105,
      6,
      0
    ],
    [
      1684.0897216796875,
      787.4592895507812,
      1693.6751708984375,
      806.9805297851562,
      "to",
      105,
      6,
      1
    ],
    [
      1696.870361328125,
      787.4592895507812,
      1733.9088134765625,
      806.9805297851562,
      "Coarse",
      105,
      6,
      2
    ],
    [
      1641.2916259765625,
      804.0693969726562,
      1662.368408203125,
      823.5906372070312,
      "Low",
      105,
      7,
      0
    ],
    [
      1665.5634765625,
      804.0693969726562,
      1675.14892578125,
      823.5906372070312,
      "to",
      105,
      7,
      1
    ],
    [
      1678.3441162109375,
      804.0693969726562,
      1701.9713134765625,
      823.5906372070312,
      "High",
      105,
      7,
      2
    ],
    [
      1705.16650390625,
      804.0693969726562,
      1742.849609375,
      823.5906372070312,
      "textural",
      105,
      7,
      3
    ],
    [
      1746.044677734375,
      804.0693969726562,
      1786.9229736328125,
      823.5906372070312,
      "contrast",
      105,
      7,
      4
    ],
    [
      1790.1180419921875,
      804.0693969726562,
      1799.7034912109375,
      823.5906372070312,
      "to",
      105,
      7,
      5
    ],
    [
      1802.8985595703125,
      804.0693969726562,
      1837.3724365234375,
      823.5906372070312,
      "WRAP",
      105,
      7,
      6
    ],
    [
      1840.567626953125,
      804.0693969726562,
      1859.7384033203125,
      823.5906372070312,
      "and",
      105,
      7,
      7
    ],
    [
      1862.9334716796875,
      804.0693969726562,
      1910.173828125,
      823.5906372070312,
      "ACCENT",
      105,
      7,
      8
    ],
    [
      1913.3690185546875,
      804.0693969726562,
      1948.487548828125,
      823.5906372070312,
      "BAND,",
      105,
      7,
      9
    ],
    [
      1641.2916259765625,
      820.6795654296875,
      1664.9188232421875,
      840.2008056640625,
      "High",
      105,
      8,
      0
    ],
    [
      1668.114013671875,
      820.6795654296875,
      1693.0166015625,
      840.2008056640625,
      "color",
      105,
      8,
      1
    ],
    [
      1696.211669921875,
      820.6795654296875,
      1737.0899658203125,
      840.2008056640625,
      "contrast",
      105,
      8,
      2
    ],
    [
      1740.2850341796875,
      820.6795654296875,
      1749.8704833984375,
      840.2008056640625,
      "to",
      105,
      8,
      3
    ],
    [
      1753.065673828125,
      820.6795654296875,
      1790.7347412109375,
      840.2008056640625,
      "WRAP.",
      105,
      8,
      4
    ],
    [
      1793.9298095703125,
      820.6795654296875,
      1815.006591796875,
      840.2008056640625,
      "Low",
      105,
      8,
      5
    ],
    [
      1818.20166015625,
      820.6795654296875,
      1827.787109375,
      840.2008056640625,
      "to",
      105,
      8,
      6
    ],
    [
      1830.982177734375,
      820.6795654296875,
      1854.6094970703125,
      840.2008056640625,
      "High",
      105,
      8,
      7
    ],
    [
      1857.8045654296875,
      820.6795654296875,
      1898.668701171875,
      840.2008056640625,
      "material",
      105,
      8,
      8
    ],
    [
      1901.86376953125,
      820.6795654296875,
      1942.7420654296875,
      840.2008056640625,
      "contrast",
      105,
      8,
      9
    ],
    [
      1945.93701171875,
      820.6795654296875,
      1955.5224609375,
      840.2008056640625,
      "to",
      105,
      8,
      10
    ],
    [
      1641.2916259765625,
      837.2896728515625,
      1678.9608154296875,
      856.8109130859375,
      "WRAP.",
      105,
      9,
      0
    ],
    [
      2053.277587890625,
      184.99159240722656,
      2094.156005859375,
      204.51280212402344,
      "Building",
      106,
      0,
      0
    ],
    [
      2097.350830078125,
      184.99159240722656,
      2138.215087890625,
      204.51280212402344,
      "material",
      106,
      0,
      1
    ],
    [
      2141.41015625,
      184.99159240722656,
      2161.84228515625,
      204.51280212402344,
      "with",
      106,
      0,
      2
    ],
    [
      2165.037353515625,
      184.99159240722656,
      2171.427734375,
      204.51280212402344,
      "a",
      106,
      0,
      3
    ],
    [
      2174.622802734375,
      184.99159240722656,
      2221.21875,
      204.51280212402344,
      "minimum",
      106,
      0,
      4
    ],
    [
      2224.41357421875,
      184.99159240722656,
      2262.7412109375,
      204.51280212402344,
      "amount",
      106,
      0,
      5
    ],
    [
      2265.9365234375,
      184.99159240722656,
      2275.521728515625,
      204.51280212402344,
      "of",
      106,
      0,
      6
    ],
    [
      2278.716796875,
      184.99159240722656,
      2305.539306640625,
      204.51280212402344,
      "joints",
      106,
      0,
      7
    ],
    [
      2308.734375,
      184.99159240722656,
      2327.905517578125,
      204.51280212402344,
      "and",
      106,
      0,
      8
    ],
    [
      2053.277587890625,
      201.60157775878906,
      2114.601806640625,
      221.12278747558594,
      "connections",
      106,
      1,
      0
    ],
    [
      2117.796875,
      201.60157775878906,
      2136.9677734375,
      221.12278747558594,
      "and",
      106,
      1,
      1
    ],
    [
      2140.162841796875,
      201.60157775878906,
      2177.845947265625,
      221.12278747558594,
      "smooth",
      106,
      1,
      2
    ],
    [
      2181.041015625,
      201.60157775878906,
      2211.058349609375,
      221.12278747558594,
      "finish:",
      106,
      1,
      3
    ],
    [
      2214.253662109375,
      201.60157775878906,
      2245.546142578125,
      221.12278747558594,
      "metal,",
      106,
      1,
      4
    ],
    [
      2248.741455078125,
      201.60157775878906,
      2274.28857421875,
      221.12278747558594,
      "EIFS",
      106,
      1,
      5
    ],
    [
      2277.483642578125,
      201.60157775878906,
      2287.69970703125,
      221.12278747558594,
      "or",
      106,
      1,
      6
    ],
    [
      2290.894775390625,
      201.60157775878906,
      2329.222412109375,
      221.12278747558594,
      "Stucco.",
      106,
      1,
      7
    ],
    [
      2053.277587890625,
      218.21168518066406,
      2078.194091796875,
      237.73289489746094,
      "Light",
      106,
      2,
      0
    ],
    [
      2081.38916015625,
      218.21168518066406,
      2090.974609375,
      237.73289489746094,
      "to",
      106,
      2,
      1
    ],
    [
      2094.169677734375,
      218.21168518066406,
      2118.427490234375,
      237.73289489746094,
      "Dark",
      106,
      2,
      2
    ],
    [
      2121.62255859375,
      218.21168518066406,
      2152.28466796875,
      237.73289489746094,
      "value.",
      106,
      2,
      3
    ],
    [
      2155.47998046875,
      218.21168518066406,
      2182.9326171875,
      237.73289489746094,
      "Color",
      106,
      2,
      4
    ],
    [
      2186.1279296875,
      218.21168518066406,
      2211.0302734375,
      237.73289489746094,
      "must",
      106,
      2,
      5
    ],
    [
      2214.2255859375,
      218.21168518066406,
      2245.518310546875,
      237.73289489746094,
      "match",
      106,
      2,
      6
    ],
    [
      2248.71337890625,
      218.21168518066406,
      2258.92919921875,
      237.73289489746094,
      "or",
      106,
      2,
      7
    ],
    [
      2262.12451171875,
      218.21168518066406,
      2324.7099609375,
      237.73289489746094,
      "complement",
      106,
      2,
      8
    ],
    [
      2053.277587890625,
      234.82179260253906,
      2091.591064453125,
      254.34300231933594,
      "window",
      106,
      3,
      0
    ],
    [
      2094.786376953125,
      234.82179260253906,
      2113.957275390625,
      254.34300231933594,
      "and",
      106,
      3,
      1
    ],
    [
      2117.15234375,
      234.82179260253906,
      2140.148681640625,
      254.34300231933594,
      "door",
      106,
      3,
      2
    ],
    [
      2143.34375,
      234.82179260253906,
      2178.46240234375,
      254.34300231933594,
      "frames",
      106,
      3,
      3
    ],
    [
      2181.657470703125,
      234.82179260253906,
      2236.605224609375,
      254.34300231933594,
      "throughout",
      106,
      3,
      4
    ],
    [
      2239.80029296875,
      234.82179260253906,
      2255.776123046875,
      254.34300231933594,
      "the",
      106,
      3,
      5
    ],
    [
      2258.97119140625,
      234.82179260253906,
      2292.82861328125,
      254.34300231933594,
      "design",
      106,
      3,
      6
    ],
    [
      2053.277587890625,
      251.43177795410156,
      2092.880615234375,
      270.9530029296875,
      "Smooth",
      106,
      4,
      0
    ],
    [
      2096.07568359375,
      251.43177795410156,
      2105.660888671875,
      270.9530029296875,
      "of",
      106,
      4,
      1
    ],
    [
      2108.85595703125,
      251.43177795410156,
      2131.208251953125,
      270.9530029296875,
      "Fine",
      106,
      4,
      2
    ],
    [
      2134.4033203125,
      251.43177795410156,
      2161.225830078125,
      270.9530029296875,
      "finish",
      106,
      4,
      3
    ],
    [
      2053.277587890625,
      268.0419006347656,
      2074.354248046875,
      287.5631103515625,
      "Low",
      106,
      5,
      0
    ],
    [
      2077.54931640625,
      268.0419006347656,
      2115.232421875,
      287.5631103515625,
      "textural",
      106,
      5,
      1
    ],
    [
      2118.427490234375,
      268.0419006347656,
      2159.305419921875,
      287.5631103515625,
      "contrast",
      106,
      5,
      2
    ],
    [
      2162.500732421875,
      268.0419006347656,
      2172.086181640625,
      287.5631103515625,
      "to",
      106,
      5,
      3
    ],
    [
      2175.28125,
      268.0419006347656,
      2212.9501953125,
      287.5631103515625,
      "WRAP.",
      106,
      5,
      4
    ],
    [
      2216.1455078125,
      268.0419006347656,
      2257.009521484375,
      287.5631103515625,
      "Medium",
      106,
      5,
      5
    ],
    [
      2260.20458984375,
      268.0419006347656,
      2269.790283203125,
      287.5631103515625,
      "to",
      106,
      5,
      6
    ],
    [
      2272.985107421875,
      268.0419006347656,
      2296.612548828125,
      287.5631103515625,
      "High",
      106,
      5,
      7
    ],
    [
      2299.8076171875,
      268.0419006347656,
      2324.7099609375,
      287.5631103515625,
      "color",
      106,
      5,
      8
    ],
    [
      2053.277587890625,
      284.6520080566406,
      2094.155517578125,
      304.1732177734375,
      "contrast",
      106,
      6,
      0
    ],
    [
      2097.350830078125,
      284.6520080566406,
      2106.936279296875,
      304.1732177734375,
      "to",
      106,
      6,
      1
    ],
    [
      2110.13134765625,
      284.6520080566406,
      2144.605224609375,
      304.1732177734375,
      "WRAP",
      106,
      6,
      2
    ],
    [
      2147.80029296875,
      284.6520080566406,
      2166.97119140625,
      304.1732177734375,
      "and",
      106,
      6,
      3
    ],
    [
      2170.166259765625,
      284.6520080566406,
      2206.559814453125,
      304.1732177734375,
      "CORE.",
      106,
      6,
      4
    ],
    [
      2209.755126953125,
      284.6520080566406,
      2230.831787109375,
      304.1732177734375,
      "Low",
      106,
      6,
      5
    ],
    [
      2234.02685546875,
      284.6520080566406,
      2274.89111328125,
      304.1732177734375,
      "material",
      106,
      6,
      6
    ],
    [
      2278.086181640625,
      284.6520080566406,
      2318.964111328125,
      304.1732177734375,
      "contrast",
      106,
      6,
      7
    ],
    [
      2322.159423828125,
      284.6520080566406,
      2331.744873046875,
      304.1732177734375,
      "to",
      106,
      6,
      8
    ],
    [
      2053.277587890625,
      301.2621154785156,
      2090.946533203125,
      320.7833251953125,
      "WRAP.",
      106,
      7,
      0
    ],
    [
      2094.1416015625,
      301.2621154785156,
      2115.218505859375,
      320.7833251953125,
      "Low",
      106,
      7,
      1
    ],
    [
      2118.41357421875,
      301.2621154785156,
      2127.9990234375,
      320.7833251953125,
      "to",
      106,
      7,
      2
    ],
    [
      2131.194091796875,
      301.2621154785156,
      2154.8212890625,
      320.7833251953125,
      "High",
      106,
      7,
      3
    ],
    [
      2158.016357421875,
      301.2621154785156,
      2198.880615234375,
      320.7833251953125,
      "material",
      106,
      7,
      4
    ],
    [
      2202.07568359375,
      301.2621154785156,
      2242.95361328125,
      320.7833251953125,
      "contrast",
      106,
      7,
      5
    ],
    [
      2246.14892578125,
      301.2621154785156,
      2255.734375,
      320.7833251953125,
      "to",
      106,
      7,
      6
    ],
    [
      2258.929443359375,
      301.2621154785156,
      2295.322998046875,
      320.7833251953125,
      "CORE.",
      106,
      7,
      7
    ],
    [
      2053.277587890625,
      367.7024841308594,
      2079.46923828125,
      387.22369384765625,
      "Steel",
      107,
      0,
      0
    ],
    [
      2082.66455078125,
      367.7024841308594,
      2125.448486328125,
      387.22369384765625,
      "columns",
      107,
      0,
      1
    ],
    [
      2128.6435546875,
      367.7024841308594,
      2147.814453125,
      387.22369384765625,
      "and",
      107,
      0,
      2
    ],
    [
      2151.009521484375,
      367.7024841308594,
      2185.497314453125,
      387.22369384765625,
      "beams",
      107,
      0,
      3
    ],
    [
      2188.6923828125,
      367.7024841308594,
      2209.124755859375,
      387.22369384765625,
      "with",
      107,
      0,
      4
    ],
    [
      2212.31982421875,
      367.7024841308594,
      2235.947021484375,
      387.22369384765625,
      "T&G",
      107,
      0,
      5
    ],
    [
      2239.14208984375,
      367.7024841308594,
      2266.609130859375,
      387.22369384765625,
      "wood",
      107,
      0,
      6
    ],
    [
      2269.80419921875,
      367.7024841308594,
      2297.27099609375,
      387.22369384765625,
      "plank",
      107,
      0,
      7
    ],
    [
      2300.46630859375,
      367.7024841308594,
      2324.738037109375,
      387.22369384765625,
      "soffit",
      107,
      0,
      8
    ],
    [
      2053.277587890625,
      384.3126220703125,
      2072.448486328125,
      403.8338317871094,
      "and",
      107,
      1,
      0
    ],
    [
      2075.6435546875,
      384.3126220703125,
      2124.187255859375,
      403.8338317871094,
      "insulation",
      107,
      1,
      1
    ],
    [
      2127.38232421875,
      384.3126220703125,
      2140.79345703125,
      403.8338317871094,
      "for",
      107,
      1,
      2
    ],
    [
      2143.988525390625,
      384.3126220703125,
      2171.455810546875,
      403.8338317871094,
      "slope",
      107,
      1,
      3
    ],
    [
      2174.650634765625,
      384.3126220703125,
      2193.821533203125,
      403.8338317871094,
      "and",
      107,
      1,
      4
    ],
    [
      2197.0166015625,
      384.3126220703125,
      2251.9365234375,
      403.8338317871094,
      "membrane",
      107,
      1,
      5
    ],
    [
      2255.131591796875,
      384.3126220703125,
      2293.459228515625,
      403.8338317871094,
      "roofing.",
      107,
      1,
      6
    ],
    [
      2053.277587890625,
      400.9227600097656,
      2077.535400390625,
      420.4439697265625,
      "Dark",
      107,
      2,
      0
    ],
    [
      2080.73046875,
      400.9227600097656,
      2108.197509765625,
      420.4439697265625,
      "value",
      107,
      2,
      1
    ],
    [
      2111.392578125,
      400.9227600097656,
      2124.17333984375,
      420.4439697265625,
      "on",
      107,
      2,
      2
    ],
    [
      2127.3681640625,
      400.9227600097656,
      2154.835205078125,
      420.4439697265625,
      "steel,",
      107,
      2,
      3
    ],
    [
      2158.0302734375,
      400.9227600097656,
      2185.497314453125,
      420.4439697265625,
      "wood",
      107,
      2,
      4
    ],
    [
      2188.6923828125,
      400.9227600097656,
      2216.159423828125,
      420.4439697265625,
      "plank",
      107,
      2,
      5
    ],
    [
      2219.3544921875,
      400.9227600097656,
      2228.940185546875,
      420.4439697265625,
      "to",
      107,
      2,
      6
    ],
    [
      2232.135009765625,
      400.9227600097656,
      2244.915771484375,
      420.4439697265625,
      "be",
      107,
      2,
      7
    ],
    [
      2248.11083984375,
      400.9227600097656,
      2273.01318359375,
      420.4439697265625,
      "clear",
      107,
      2,
      8
    ],
    [
      2276.208251953125,
      400.9227600097656,
      2303.67529296875,
      420.4439697265625,
      "stain,",
      107,
      2,
      9
    ],
    [
      2053.277587890625,
      417.5327453613281,
      2108.197509765625,
      437.053955078125,
      "membrane",
      107,
      3,
      0
    ],
    [
      2111.392578125,
      417.5327453613281,
      2146.525146484375,
      437.053955078125,
      "roofing",
      107,
      3,
      1
    ],
    [
      2149.72021484375,
      417.5327453613281,
      2174.62255859375,
      437.053955078125,
      "color",
      107,
      3,
      2
    ],
    [
      2177.81787109375,
      417.5327453613281,
      2187.4033203125,
      437.053955078125,
      "to",
      107,
      3,
      3
    ],
    [
      2190.59814453125,
      417.5327453613281,
      2221.89111328125,
      437.053955078125,
      "match",
      107,
      3,
      4
    ],
    [
      2225.086181640625,
      417.5327453613281,
      2249.98876953125,
      437.053955078125,
      "main",
      107,
      3,
      5
    ],
    [
      2253.18359375,
      417.5327453613281,
      2276.18017578125,
      437.053955078125,
      "roof.",
      107,
      3,
      6
    ],
    [
      2053.277587890625,
      434.14288330078125,
      2096.075439453125,
      453.6640930175781,
      "Smooth,",
      107,
      4,
      0
    ],
    [
      2099.270751953125,
      434.14288330078125,
      2136.9677734375,
      453.6640930175781,
      "painted",
      107,
      4,
      1
    ],
    [
      2140.162841796875,
      434.14288330078125,
      2170.18017578125,
      453.6640930175781,
      "finish.",
      107,
      4,
      2
    ],
    [
      2375.615234375,
      1428.5606689453125,
      2426.309814453125,
      1441.80712890625,
      "KRISTOPHER",
      108,
      0,
      0
    ],
    [
      2428.477783203125,
      1428.5606689453125,
      2456.644775390625,
      1441.80712890625,
      "PELOW",
      108,
      0,
      1
    ],
    [
      2375.615234375,
      1439.634033203125,
      2408.127685546875,
      1452.8804931640625,
      "AR99671",
      108,
      1,
      0
    ],
    [
      2410.2958984375,
      1439.634033203125,
      2415.49755859375,
      1452.8804931640625,
      "&",
      108,
      1,
      1
    ],
    [
      2417.665771484375,
      1439.634033203125,
      2425.463623046875,
      1452.8804931640625,
      "ID",
      108,
      1,
      2
    ],
    [
      2427.63134765625,
      1439.634033203125,
      2444.9765625,
      1452.8804931640625,
      "6707",
      108,
      1,
      3
    ],
    [
      2372.92138671875,
      1204.083251953125,
      2415.39013671875,
      1217.3297119140625,
      "REVISIONS",
      109,
      0,
      0
    ],
    [
      2375.615234375,
      1474.84326171875,
      2412.007568359375,
      1488.0897216796875,
      "PROJECT",
      110,
      0,
      0
    ],
    [
      2414.17578125,
      1474.84326171875,
      2428.040283203125,
      1488.0897216796875,
      "NO:",
      110,
      0,
      1
    ],
    [
      2375.615234375,
      1485.9166259765625,
      2405.065673828125,
      1499.1630859375,
      "DRAWN",
      110,
      1,
      0
    ],
    [
      2407.23388671875,
      1485.9166259765625,
      2419.805419921875,
      1499.1630859375,
      "BY:",
      110,
      1,
      1
    ],
    [
      2421.97314453125,
      1485.9166259765625,
      2436.275390625,
      1499.1630859375,
      "KJP",
      110,
      1,
      2
    ],
    [
      2375.615234375,
      1496.989990234375,
      2413.738525390625,
      1510.2364501953125,
      "CHECKED",
      110,
      2,
      0
    ],
    [
      2415.90625,
      1496.989990234375,
      2428.477783203125,
      1510.2364501953125,
      "BY:",
      110,
      2,
      1
    ],
    [
      2430.64599609375,
      1496.989990234375,
      2457.947509765625,
      1510.2364501953125,
      "KJP/EC",
      110,
      2,
      2
    ],
    [
      2487.87109375,
      534.5542602539062,
      2501.11767578125,
      547.56298828125,
      "205",
      111,
      0,
      0
    ],
    [
      2487.87109375,
      524.58837890625,
      2501.11767578125,
      532.3861083984375,
      "N.",
      111,
      0,
      1
    ],
    [
      2487.87109375,
      496.4122009277344,
      2501.11767578125,
      522.4202880859375,
      "Orange",
      111,
      0,
      2
    ],
    [
      2487.87109375,
      478.63922119140625,
      2501.11767578125,
      494.24407958984375,
      "Ave,",
      111,
      0,
      3
    ],
    [
      2487.87109375,
      458.6980895996094,
      2501.11767578125,
      476.4710998535156,
      "Suite",
      111,
      0,
      4
    ],
    [
      2487.87109375,
      441.35302734375,
      2501.11767578125,
      456.52996826171875,
      "301,",
      111,
      0,
      5
    ],
    [
      2487.87109375,
      405.80706787109375,
      2501.11767578125,
      439.1849060058594,
      "Sarasota,",
      111,
      0,
      6
    ],
    [
      2487.87109375,
      394.5384826660156,
      2501.11767578125,
      403.6389465332031,
      "FL",
      111,
      0,
      7
    ],
    [
      2487.87109375,
      370.6889953613281,
      2501.11767578125,
      392.370361328125,
      "34236",
      111,
      0,
      8
    ],
    [
      2347.4072265625,
      499.3835754394531,
      2364.486328125,
      608.5408935546875,
      "DESIGN/BUILDER:",
      112,
      0,
      0
    ],
    [
      2347.4072265625,
      211.40475463867188,
      2364.486328125,
      286.478515625,
      "ARCHITECT:",
      112,
      1,
      0
    ],
    [
      2347.4072265625,
      725.6925048828125,
      2364.486328125,
      767.4085693359375,
      "HOTEL",
      112,
      2,
      0
    ],
    [
      2347.4072265625,
      674.9425659179688,
      2364.486328125,
      722.2140502929688,
      "BRAND:",
      112,
      2,
      1
    ],
    [
      2461.993896484375,
      273.4696960449219,
      2475.240478515625,
      286.47845458984375,
      "205",
      113,
      0,
      0
    ],
    [
      2461.993896484375,
      263.5039367675781,
      2475.240478515625,
      271.30157470703125,
      "N.",
      113,
      0,
      1
    ],
    [
      2461.993896484375,
      235.32774353027344,
      2475.240478515625,
      261.33575439453125,
      "Orange",
      113,
      0,
      2
    ],
    [
      2461.993896484375,
      217.55482482910156,
      2475.240478515625,
      233.15960693359375,
      "Ave,",
      113,
      0,
      3
    ],
    [
      2461.993896484375,
      197.6136932373047,
      2475.240478515625,
      215.38665771484375,
      "Suite",
      113,
      0,
      4
    ],
    [
      2461.993896484375,
      180.26869201660156,
      2475.240478515625,
      195.445556640625,
      "301,",
      113,
      0,
      5
    ],
    [
      2461.993896484375,
      144.72279357910156,
      2475.240478515625,
      178.10052490234375,
      "Sarasota,",
      113,
      0,
      6
    ],
    [
      2461.993896484375,
      133.45420837402344,
      2475.240478515625,
      142.55462646484375,
      "FL",
      113,
      0,
      7
    ],
    [
      2461.993896484375,
      109.6048355102539,
      2475.240478515625,
      131.28607177734375,
      "34236",
      113,
      0,
      8
    ],
    [
      2375.615234375,
      1618.4561767578125,
      2452.82861328125,
      1669.694091796875,
      "A4.2",
      114,
      0,
      0
    ],
    [
      2375.615234375,
      1539.6614990234375,
      2495.05322265625,
      1565.6219482421875,
      "ELEVATIONS",
      115,
      0,
      0
    ],
    [
      2399.079833984375,
      1019.5123291015625,
      2433.238525390625,
      1094.586181640625,
      "HOME",
      116,
      0,
      0
    ],
    [
      2399.079833984375,
      998.6417846679688,
      2433.238525390625,
      1012.5554809570312,
      "2",
      116,
      0,
      1
    ],
    [
      2399.079833984375,
      901.2960205078125,
      2433.238525390625,
      991.6849365234375,
      "SUITES",
      116,
      0,
      2
    ],
    [
      2437.09033203125,
      1118.8070068359375,
      2454.16943359375,
      1143.8441162109375,
      "90%",
      117,
      0,
      0
    ],
    [
      2437.09033203125,
      1014.5419311523438,
      2454.16943359375,
      1115.32861328125,
      "CONSTRUCTION",
      117,
      0,
      1
    ],
    [
      2437.09033203125,
      930.4342041015625,
      2454.16943359375,
      1011.0634765625,
      "DOCUMENTS",
      117,
      0,
      2
    ],
    [
      2437.09033203125,
      922.7891235351562,
      2454.16943359375,
      926.9557495117188,
      "-",
      117,
      0,
      3
    ],
    [
      2437.09033203125,
      853.220703125,
      2454.16943359375,
      915.832275390625,
      "04.30.2025",
      117,
      0,
      4
    ],
    [
      2465.547119140625,
      968.163818359375,
      2482.626220703125,
      1050.194580078125,
      "BRADENTON,",
      118,
      0,
      0
    ],
    [
      2465.547119140625,
      946.6051025390625,
      2482.626220703125,
      964.6853637695312,
      "FL.",
      118,
      0,
      1
    ],
    [
      2437.225830078125,
      1474.84326171875,
      2463.243408203125,
      1488.0897216796875,
      "210729",
      119,
      0,
      0
    ],
    [
      135.5579833984375,
      848.0594482421875,
      157.39181518554688,
      865.1387939453125,
      "1/8\"",
      120,
      0,
      0
    ],
    [
      160.8702392578125,
      848.0594482421875,
      168.17742919921875,
      865.1387939453125,
      "=",
      120,
      0,
      1
    ],
    [
      171.65576171875,
      848.0594482421875,
      196.56771850585938,
      865.1387939453125,
      "1'-0\"",
      120,
      0,
      2
    ],
    [
      114.8919677734375,
      839.919677734375,
      121.84881591796875,
      856.9990234375,
      "1",
      120,
      1,
      0
    ],
    [
      132.8570556640625,
      833.5369262695312,
      184.31988525390625,
      850.6162719726562,
      "Elevation",
      120,
      2,
      0
    ],
    [
      187.7982177734375,
      833.5369262695312,
      194.75506591796875,
      850.6162719726562,
      "3",
      120,
      2,
      1
    ],
    [
      198.2333984375,
      833.5369262695312,
      202.39999389648438,
      850.6162719726562,
      "-",
      120,
      2,
      2
    ],
    [
      205.87841796875,
      833.5369262695312,
      212.83526611328125,
      850.6162719726562,
      "a",
      120,
      2,
      3
    ],
    [
      135.5579833984375,
      1656.9730224609375,
      157.39181518554688,
      1674.0523681640625,
      "1/8\"",
      121,
      0,
      0
    ],
    [
      160.8702392578125,
      1656.9730224609375,
      168.17742919921875,
      1674.0523681640625,
      "=",
      121,
      0,
      1
    ],
    [
      171.65576171875,
      1656.9730224609375,
      196.56771850585938,
      1674.0523681640625,
      "1'-0\"",
      121,
      0,
      2
    ],
    [
      114.8919677734375,
      1648.8331298828125,
      121.84881591796875,
      1665.9124755859375,
      "2",
      121,
      1,
      0
    ],
    [
      132.8570556640625,
      1642.450439453125,
      184.31988525390625,
      1659.52978515625,
      "Elevation",
      121,
      2,
      0
    ],
    [
      187.7982177734375,
      1642.450439453125,
      194.75506591796875,
      1659.52978515625,
      "4",
      121,
      2,
      1
    ],
    [
      198.2333984375,
      1642.450439453125,
      202.39999389648438,
      1659.52978515625,
      "-",
      121,
      2,
      2
    ],
    [
      205.87841796875,
      1642.450439453125,
      212.83526611328125,
      1659.52978515625,
      "a",
      121,
      2,
      3
    ],
    [
      2373.92431640625,
      1219.7752685546875,
      2388.720947265625,
      1232.755615234375,
      "No.",
      122,
      0,
      0
    ],
    [
      2413.19921875,
      1219.7752685546875,
      2460.75537109375,
      1232.755615234375,
      "Description",
      122,
      1,
      0
    ],
    [
      2491.61279296875,
      1219.7752685546875,
      2511.6962890625,
      1232.755615234375,
      "Date",
      122,
      2,
      0
    ],
    [
      469.7718505859375,
      277.0003662109375,
      480.1750793457031,
      290.24688720703125,
      "EX",
      123,
      0,
      0
    ],
    [
      482.34320068359375,
      277.0003662109375,
      484.9392395019531,
      290.24688720703125,
      "-",
      123,
      0,
      1
    ],
    [
      487.107421875,
      277.0003662109375,
      491.4436950683594,
      290.24688720703125,
      "8",
      123,
      0,
      2
    ],
    [
      469.7718505859375,
      313.03582763671875,
      480.1750793457031,
      326.2823486328125,
      "EX",
      124,
      0,
      0
    ],
    [
      482.34320068359375,
      313.03582763671875,
      484.9392395019531,
      326.2823486328125,
      "-",
      124,
      0,
      1
    ],
    [
      487.107421875,
      313.03582763671875,
      491.4436950683594,
      326.2823486328125,
      "2",
      124,
      0,
      2
    ],
    [
      566.0050659179688,
      335.25299072265625,
      576.4082641601562,
      348.49951171875,
      "EX",
      125,
      0,
      0
    ],
    [
      578.576416015625,
      335.25299072265625,
      581.1724853515625,
      348.49951171875,
      "-",
      125,
      0,
      1
    ],
    [
      583.3406372070312,
      335.25299072265625,
      587.6768798828125,
      348.49951171875,
      "5",
      125,
      0,
      2
    ],
    [
      375.82232666015625,
      524.0499267578125,
      386.2255554199219,
      537.2964477539062,
      "EX",
      126,
      0,
      0
    ],
    [
      388.3936767578125,
      524.0499267578125,
      390.9897155761719,
      537.2964477539062,
      "-",
      126,
      0,
      1
    ],
    [
      393.15789794921875,
      524.0499267578125,
      397.4941711425781,
      537.2964477539062,
      "2",
      126,
      0,
      2
    ],
    [
      566.0050659179688,
      422.3387145996094,
      576.4082641601562,
      435.5852355957031,
      "EX",
      127,
      0,
      0
    ],
    [
      578.576416015625,
      422.3387145996094,
      581.1724853515625,
      435.5852355957031,
      "-",
      127,
      0,
      1
    ],
    [
      583.3406372070312,
      422.3387145996094,
      587.6768798828125,
      435.5852355957031,
      "5",
      127,
      0,
      2
    ],
    [
      566.0050659179688,
      509.4244384765625,
      576.4082641601562,
      522.6709594726562,
      "EX",
      128,
      0,
      0
    ],
    [
      578.576416015625,
      509.4244384765625,
      581.1724853515625,
      522.6709594726562,
      "-",
      128,
      0,
      1
    ],
    [
      583.3406372070312,
      509.4244384765625,
      587.6768798828125,
      522.6709594726562,
      "5",
      128,
      0,
      2
    ],
    [
      566.0050659179688,
      596.5101318359375,
      576.4082641601562,
      609.7566528320312,
      "EX",
      129,
      0,
      0
    ],
    [
      578.576416015625,
      596.5101318359375,
      581.1724853515625,
      609.7566528320312,
      "-",
      129,
      0,
      1
    ],
    [
      583.3406372070312,
      596.5101318359375,
      587.6768798828125,
      609.7566528320312,
      "5",
      129,
      0,
      2
    ],
    [
      520.4968872070312,
      684.7273559570312,
      530.9000854492188,
      697.973876953125,
      "EX",
      130,
      0,
      0
    ],
    [
      533.0682373046875,
      684.7273559570312,
      535.664306640625,
      697.973876953125,
      "-",
      130,
      0,
      1
    ],
    [
      537.8324584960938,
      684.7273559570312,
      542.168701171875,
      697.973876953125,
      "2",
      130,
      0,
      2
    ],
    [
      469.7718505859375,
      379.4800109863281,
      480.1750793457031,
      392.7265319824219,
      "EX",
      131,
      0,
      0
    ],
    [
      482.34320068359375,
      379.4800109863281,
      484.9392395019531,
      392.7265319824219,
      "-",
      131,
      0,
      1
    ],
    [
      487.107421875,
      379.4800109863281,
      491.4436950683594,
      392.7265319824219,
      "1",
      131,
      0,
      2
    ],
    [
      469.7718505859375,
      469.56866455078125,
      480.1750793457031,
      482.815185546875,
      "EX",
      132,
      0,
      0
    ],
    [
      482.34320068359375,
      469.56866455078125,
      484.9392395019531,
      482.815185546875,
      "-",
      132,
      0,
      1
    ],
    [
      487.107421875,
      469.56866455078125,
      491.4436950683594,
      482.815185546875,
      "1",
      132,
      0,
      2
    ],
    [
      469.7718505859375,
      554.008056640625,
      480.1750793457031,
      567.2545776367188,
      "EX",
      133,
      0,
      0
    ],
    [
      482.34320068359375,
      554.008056640625,
      484.9392395019531,
      567.2545776367188,
      "-",
      133,
      0,
      1
    ],
    [
      487.107421875,
      554.008056640625,
      491.4436950683594,
      567.2545776367188,
      "1",
      133,
      0,
      2
    ],
    [
      469.7718505859375,
      640.5706176757812,
      480.1750793457031,
      653.817138671875,
      "EX",
      134,
      0,
      0
    ],
    [
      482.34320068359375,
      640.5706176757812,
      484.9392395019531,
      653.817138671875,
      "-",
      134,
      0,
      1
    ],
    [
      487.107421875,
      640.5706176757812,
      491.4436950683594,
      653.817138671875,
      "1",
      134,
      0,
      2
    ],
    [
      659.5278930664062,
      423.76605224609375,
      668.2003784179688,
      437.0125732421875,
      "18",
      135,
      0,
      0
    ],
    [
      659.5278930664062,
      336.25299072265625,
      668.2003784179688,
      349.49951171875,
      "18",
      136,
      0,
      0
    ],
    [
      659.5278930664062,
      510.5889892578125,
      668.2003784179688,
      523.8355102539062,
      "18",
      137,
      0,
      0
    ],
    [
      659.5278930664062,
      597.691650390625,
      668.2003784179688,
      610.9381713867188,
      "18",
      138,
      0,
      0
    ],
    [
      659.5278930664062,
      687.7802734375,
      668.2003784179688,
      701.0267944335938,
      "18",
      139,
      0,
      0
    ],
    [
      802.5079345703125,
      379.4800109863281,
      812.9111328125,
      392.7265319824219,
      "EX",
      140,
      0,
      0
    ],
    [
      815.0792846679688,
      379.4800109863281,
      817.6753540039062,
      392.7265319824219,
      "-",
      140,
      0,
      1
    ],
    [
      819.8434448242188,
      379.4800109863281,
      824.1796875,
      392.7265319824219,
      "3",
      140,
      0,
      2
    ],
    [
      802.5079345703125,
      466.76470947265625,
      812.9111328125,
      480.01123046875,
      "EX",
      141,
      0,
      0
    ],
    [
      815.0792846679688,
      466.76470947265625,
      817.6753540039062,
      480.01123046875,
      "-",
      141,
      0,
      1
    ],
    [
      819.8434448242188,
      466.76470947265625,
      824.1796875,
      480.01123046875,
      "3",
      141,
      0,
      2
    ],
    [
      802.5079345703125,
      553.4650268554688,
      812.9111328125,
      566.7115478515625,
      "EX",
      142,
      0,
      0
    ],
    [
      815.0792846679688,
      553.4650268554688,
      817.6753540039062,
      566.7115478515625,
      "-",
      142,
      0,
      1
    ],
    [
      819.8434448242188,
      553.4650268554688,
      824.1796875,
      566.7115478515625,
      "3",
      142,
      0,
      2
    ],
    [
      802.5079345703125,
      643.5537109375,
      812.9111328125,
      656.8002319335938,
      "EX",
      143,
      0,
      0
    ],
    [
      815.0792846679688,
      643.5537109375,
      817.6753540039062,
      656.8002319335938,
      "-",
      143,
      0,
      1
    ],
    [
      819.8434448242188,
      643.5537109375,
      824.1796875,
      656.8002319335938,
      "3",
      143,
      0,
      2
    ],
    [
      916.3543701171875,
      524.0499267578125,
      926.757568359375,
      537.2964477539062,
      "EX",
      144,
      0,
      0
    ],
    [
      928.9257202148438,
      524.0499267578125,
      931.5217895507812,
      537.2964477539062,
      "-",
      144,
      0,
      1
    ],
    [
      933.6898803710938,
      524.0499267578125,
      938.026123046875,
      537.2964477539062,
      "2",
      144,
      0,
      2
    ],
    [
      617.1573486328125,
      747.4993896484375,
      627.560546875,
      760.7459106445312,
      "EX",
      145,
      0,
      0
    ],
    [
      629.7286987304688,
      747.4993896484375,
      632.3247680664062,
      760.7459106445312,
      "-",
      145,
      0,
      1
    ],
    [
      634.492919921875,
      747.4993896484375,
      638.8291625976562,
      760.7459106445312,
      "6",
      145,
      0,
      2
    ],
    [
      720.7291259765625,
      370.51715087890625,
      729.401611328125,
      383.763671875,
      "10",
      146,
      0,
      0
    ],
    [
      720.7291259765625,
      460.6058349609375,
      729.401611328125,
      473.85235595703125,
      "10",
      147,
      0,
      0
    ],
    [
      720.7291259765625,
      544.8720703125,
      729.401611328125,
      558.1185913085938,
      "10",
      148,
      0,
      0
    ],
    [
      720.7291259765625,
      632.0452880859375,
      729.401611328125,
      645.2918090820312,
      "10",
      149,
      0,
      0
    ],
    [
      473.82879638671875,
      741.9723510742188,
      478.1650695800781,
      755.2188720703125,
      "9",
      150,
      0,
      0
    ],
    [
      2078.11767578125,
      1248.2119140625,
      2084.6220703125,
      1261.4583740234375,
      "1.",
      151,
      0,
      0
    ],
    [
      2086.7900390625,
      1248.2119140625,
      2143.12353515625,
      1261.4583740234375,
      "APPROXIMATE",
      151,
      0,
      1
    ],
    [
      2145.29150390625,
      1248.2119140625,
      2162.627197265625,
      1261.4583740234375,
      "LINE",
      151,
      0,
      2
    ],
    [
      2164.795166015625,
      1248.2119140625,
      2175.62646484375,
      1261.4583740234375,
      "OF",
      151,
      0,
      3
    ],
    [
      2177.79443359375,
      1248.2119140625,
      2205.523681640625,
      1261.4583740234375,
      "GRADE",
      151,
      0,
      4
    ],
    [
      2078.11767578125,
      1259.285400390625,
      2084.6220703125,
      1272.5318603515625,
      "2.",
      151,
      1,
      0
    ],
    [
      2086.7900390625,
      1259.285400390625,
      2113.66357421875,
      1272.5318603515625,
      "ABOVE",
      151,
      1,
      1
    ],
    [
      2115.83154296875,
      1259.285400390625,
      2143.56103515625,
      1272.5318603515625,
      "GRADE",
      151,
      1,
      2
    ],
    [
      2145.72900390625,
      1259.285400390625,
      2183.43359375,
      1272.5318603515625,
      "EXPOSED",
      151,
      1,
      3
    ],
    [
      2185.6015625,
      1259.285400390625,
      2237.15185546875,
      1272.5318603515625,
      "FOUNDATION",
      151,
      1,
      4
    ],
    [
      2239.31982421875,
      1259.285400390625,
      2260.553955078125,
      1272.5318603515625,
      "WALL",
      151,
      1,
      5
    ],
    [
      2078.11767578125,
      1270.3587646484375,
      2084.6220703125,
      1283.605224609375,
      "4.",
      151,
      2,
      0
    ],
    [
      2086.7900390625,
      1270.3587646484375,
      2120.58642578125,
      1283.605224609375,
      "PAINTED",
      151,
      2,
      1
    ],
    [
      2122.75439453125,
      1270.3587646484375,
      2143.55126953125,
      1283.605224609375,
      "TUBE",
      151,
      2,
      2
    ],
    [
      2145.719482421875,
      1270.3587646484375,
      2170.424560546875,
      1283.605224609375,
      "STEEL",
      151,
      2,
      3
    ],
    [
      2172.5927734375,
      1270.3587646484375,
      2205.523681640625,
      1283.605224609375,
      "CANOPY",
      151,
      2,
      4
    ],
    [
      2207.69189453125,
      1270.3587646484375,
      2227.614013671875,
      1283.605224609375,
      "WITH",
      151,
      2,
      5
    ],
    [
      2229.781982421875,
      1270.3587646484375,
      2254.90576171875,
      1283.605224609375,
      "WOOD",
      151,
      2,
      6
    ],
    [
      2257.07373046875,
      1270.3587646484375,
      2293.466064453125,
      1283.605224609375,
      "FINISHED",
      151,
      2,
      7
    ],
    [
      2295.63427734375,
      1270.3587646484375,
      2323.36328125,
      1283.605224609375,
      "SOFFIT",
      151,
      2,
      8
    ],
    [
      2078.11767578125,
      1281.43212890625,
      2084.6220703125,
      1294.6785888671875,
      "5.",
      151,
      3,
      0
    ],
    [
      2086.7900390625,
      1281.43212890625,
      2124.913330078125,
      1294.6785888671875,
      "MODIFIED",
      151,
      3,
      1
    ],
    [
      2127.081298828125,
      1281.43212890625,
      2152.205078125,
      1294.6785888671875,
      "WOOD",
      151,
      3,
      2
    ],
    [
      2154.373046875,
      1281.43212890625,
      2187.303955078125,
      1294.6785888671875,
      "CANOPY",
      151,
      3,
      3
    ],
    [
      2189.471923828125,
      1281.43212890625,
      2209.394287109375,
      1294.6785888671875,
      "WITH",
      151,
      3,
      4
    ],
    [
      2211.562255859375,
      1281.43212890625,
      2236.267333984375,
      1294.6785888671875,
      "STEEL",
      151,
      3,
      5
    ],
    [
      2238.435546875,
      1281.43212890625,
      2276.13037109375,
      1294.6785888671875,
      "SUPPORT",
      151,
      3,
      6
    ],
    [
      2078.11767578125,
      1292.505615234375,
      2084.6220703125,
      1305.7520751953125,
      "6.",
      151,
      4,
      0
    ],
    [
      2086.7900390625,
      1292.505615234375,
      2137.912353515625,
      1305.7520751953125,
      "MECHANICAL",
      151,
      4,
      1
    ],
    [
      2140.08056640625,
      1292.505615234375,
      2186.4384765625,
      1305.7520751953125,
      "EQUIPMENT",
      151,
      4,
      2
    ],
    [
      2188.6064453125,
      1292.505615234375,
      2221.10009765625,
      1305.7520751953125,
      "SCREEN",
      151,
      4,
      3
    ],
    [
      2223.26806640625,
      1292.505615234375,
      2225.864013671875,
      1305.7520751953125,
      "-",
      151,
      4,
      4
    ],
    [
      2228.0322265625,
      1292.505615234375,
      2258.795166015625,
      1305.7520751953125,
      "REVIEW",
      151,
      4,
      5
    ],
    [
      2260.963134765625,
      1292.505615234375,
      2274.837158203125,
      1305.7520751953125,
      "ALL",
      151,
      4,
      6
    ],
    [
      2277.00537109375,
      1292.505615234375,
      2302.138671875,
      1305.7520751953125,
      "VIEWS",
      151,
      4,
      7
    ],
    [
      2304.306640625,
      1292.505615234375,
      2338.093505859375,
      1305.7520751953125,
      "AROUND",
      151,
      4,
      8
    ],
    [
      2078.11767578125,
      1303.5789794921875,
      2121.01416015625,
      1316.825439453125,
      "PROPERTY",
      151,
      5,
      0
    ],
    [
      2123.182373046875,
      1303.5789794921875,
      2155.247802734375,
      1316.825439453125,
      "BEFORE",
      151,
      5,
      1
    ],
    [
      2157.416015625,
      1303.5789794921875,
      2197.27880859375,
      1316.825439453125,
      "LOCATING",
      151,
      5,
      2
    ],
    [
      2199.447265625,
      1303.5789794921875,
      2213.321044921875,
      1316.825439453125,
      "ALL",
      151,
      5,
      3
    ],
    [
      2215.4892578125,
      1303.5789794921875,
      2238.01708984375,
      1316.825439453125,
      "ROOF",
      151,
      5,
      4
    ],
    [
      2240.18505859375,
      1303.5789794921875,
      2256.2177734375,
      1316.825439453125,
      "TOP",
      151,
      5,
      5
    ],
    [
      2258.385986328125,
      1303.5789794921875,
      2309.508056640625,
      1316.825439453125,
      "MECHANICAL",
      151,
      5,
      6
    ],
    [
      2311.67626953125,
      1303.5789794921875,
      2337.237548828125,
      1316.825439453125,
      "UNITS.",
      151,
      5,
      7
    ],
    [
      2078.11767578125,
      1314.65234375,
      2106.2841796875,
      1327.8988037109375,
      "VERIFY",
      151,
      6,
      0
    ],
    [
      2108.452392578125,
      1314.65234375,
      2122.326416015625,
      1327.8988037109375,
      "ALL",
      151,
      6,
      1
    ],
    [
      2124.49462890625,
      1314.65234375,
      2170.8525390625,
      1327.8988037109375,
      "EQUIPMENT",
      151,
      6,
      2
    ],
    [
      2173.020751953125,
      1314.65234375,
      2180.390625,
      1327.8988037109375,
      "IS",
      151,
      6,
      3
    ],
    [
      2182.55859375,
      1314.65234375,
      2234.9931640625,
      1327.8988037109375,
      "ADEQUATELY",
      151,
      6,
      4
    ],
    [
      2237.1611328125,
      1314.65234375,
      2282.65380859375,
      1327.8988037109375,
      "SCREENED.",
      151,
      6,
      5
    ],
    [
      2078.11767578125,
      1325.725830078125,
      2084.6220703125,
      1338.9722900390625,
      "8.",
      151,
      7,
      0
    ],
    [
      2086.7900390625,
      1325.725830078125,
      2130.542724609375,
      1338.9722900390625,
      "ALUMINIUM",
      151,
      7,
      1
    ],
    [
      2132.710693359375,
      1325.725830078125,
      2155.676025390625,
      1338.9722900390625,
      "FIXED",
      151,
      7,
      2
    ],
    [
      2157.843994140625,
      1325.725830078125,
      2192.05859375,
      1338.9722900390625,
      "WINDOW",
      151,
      7,
      3
    ],
    [
      2194.2265625,
      1325.725830078125,
      2214.14892578125,
      1338.9722900390625,
      "WITH",
      151,
      7,
      4
    ],
    [
      2216.31689453125,
      1325.725830078125,
      2253.574462890625,
      1338.9722900390625,
      "THERMAL",
      151,
      7,
      5
    ],
    [
      2255.74267578125,
      1325.725830078125,
      2288.673583984375,
      1338.9722900390625,
      "BROKEN",
      151,
      7,
      6
    ],
    [
      2290.841552734375,
      1325.725830078125,
      2320.301513671875,
      1338.9722900390625,
      "FRAME,",
      151,
      7,
      7
    ],
    [
      2078.11767578125,
      1336.7991943359375,
      2121.879638671875,
      1350.045654296875,
      "INSULATED",
      151,
      8,
      0
    ],
    [
      2124.047607421875,
      1336.7991943359375,
      2158.28125,
      1350.045654296875,
      "GLAZING",
      151,
      8,
      1
    ],
    [
      2160.449462890625,
      1336.7991943359375,
      2180.37158203125,
      1350.045654296875,
      "WITH",
      151,
      8,
      2
    ],
    [
      2182.53955078125,
      1336.7991943359375,
      2221.537353515625,
      1350.045654296875,
      "INTEGRAL",
      151,
      8,
      3
    ],
    [
      2223.70556640625,
      1336.7991943359375,
      2267.4580078125,
      1350.045654296875,
      "ALUMINIUM",
      151,
      8,
      4
    ],
    [
      2269.6259765625,
      1336.7991943359375,
      2301.691650390625,
      1350.045654296875,
      "LOUVER",
      151,
      8,
      5
    ],
    [
      2303.859619140625,
      1336.7991943359375,
      2313.825439453125,
      1350.045654296875,
      "AT",
      151,
      8,
      6
    ],
    [
      2315.99365234375,
      1336.7991943359375,
      2336.790771484375,
      1350.045654296875,
      "PTAC",
      151,
      8,
      7
    ],
    [
      2078.11767578125,
      1347.87255859375,
      2103.6787109375,
      1361.1190185546875,
      "UNITS.",
      151,
      9,
      0
    ],
    [
      2078.11767578125,
      1358.946044921875,
      2084.6220703125,
      1372.1925048828125,
      "9.",
      151,
      10,
      0
    ],
    [
      2086.7900390625,
      1358.946044921875,
      2130.542724609375,
      1372.1925048828125,
      "ALUMINIUM",
      151,
      10,
      1
    ],
    [
      2132.710693359375,
      1358.946044921875,
      2186.428955078125,
      1372.1925048828125,
      "STOREFRONT",
      151,
      10,
      2
    ],
    [
      2188.59716796875,
      1358.946044921875,
      2220.662353515625,
      1372.1925048828125,
      "SYSTEM",
      151,
      10,
      3
    ],
    [
      2222.83056640625,
      1358.946044921875,
      2242.752685546875,
      1372.1925048828125,
      "WITH",
      151,
      10,
      4
    ],
    [
      2244.9208984375,
      1358.946044921875,
      2282.17822265625,
      1372.1925048828125,
      "THERMAL",
      151,
      10,
      5
    ],
    [
      2284.346435546875,
      1358.946044921875,
      2317.27734375,
      1372.1925048828125,
      "BROKEN",
      151,
      10,
      6
    ],
    [
      2319.4453125,
      1358.946044921875,
      2346.7373046875,
      1372.1925048828125,
      "FRAME",
      151,
      10,
      7
    ],
    [
      2078.11767578125,
      1370.019287109375,
      2094.578369140625,
      1383.2657470703125,
      "AND",
      151,
      11,
      0
    ],
    [
      2096.746337890625,
      1370.019287109375,
      2140.508544921875,
      1383.2657470703125,
      "INSULATED",
      151,
      11,
      1
    ],
    [
      2142.676513671875,
      1370.019287109375,
      2176.909912109375,
      1383.2657470703125,
      "GLAZING",
      151,
      11,
      2
    ],
    [
      2078.11767578125,
      1381.0927734375,
      2088.958251953125,
      1394.3392333984375,
      "10.",
      151,
      12,
      0
    ],
    [
      2091.12646484375,
      1381.0927734375,
      2134.87890625,
      1394.3392333984375,
      "ALUMINIUM",
      151,
      12,
      1
    ],
    [
      2137.046875,
      1381.0927734375,
      2160.01220703125,
      1394.3392333984375,
      "FIXED",
      151,
      12,
      2
    ],
    [
      2162.18017578125,
      1381.0927734375,
      2196.39501953125,
      1394.3392333984375,
      "WINDOW",
      151,
      12,
      3
    ],
    [
      2198.56298828125,
      1381.0927734375,
      2218.485107421875,
      1394.3392333984375,
      "WITH",
      151,
      12,
      4
    ],
    [
      2220.653076171875,
      1381.0927734375,
      2257.91064453125,
      1394.3392333984375,
      "THERMAL",
      151,
      12,
      5
    ],
    [
      2260.078857421875,
      1381.0927734375,
      2293.009765625,
      1394.3392333984375,
      "BROKEN",
      151,
      12,
      6
    ],
    [
      2295.177734375,
      1381.0927734375,
      2322.469482421875,
      1394.3392333984375,
      "FRAME",
      151,
      12,
      7
    ],
    [
      2324.6376953125,
      1381.0927734375,
      2341.098388671875,
      1394.3392333984375,
      "AND",
      151,
      12,
      8
    ],
    [
      2078.11767578125,
      1392.1661376953125,
      2121.879638671875,
      1405.41259765625,
      "INSULATED",
      151,
      13,
      0
    ],
    [
      2124.047607421875,
      1392.1661376953125,
      2158.28125,
      1405.41259765625,
      "GLAZING",
      151,
      13,
      1
    ],
    [
      2078.11767578125,
      1403.239501953125,
      2088.958251953125,
      1416.4859619140625,
      "11.",
      151,
      14,
      0
    ],
    [
      2091.12646484375,
      1403.239501953125,
      2132.729736328125,
      1416.4859619140625,
      "ELEVATOR",
      151,
      14,
      1
    ],
    [
      2134.89794921875,
      1403.239501953125,
      2173.88623046875,
      1416.4859619140625,
      "OVERRUN",
      151,
      14,
      2
    ],
    [
      2078.11767578125,
      1414.31298828125,
      2088.958251953125,
      1427.5594482421875,
      "13.",
      151,
      15,
      0
    ],
    [
      2091.12646484375,
      1414.31298828125,
      2128.384033203125,
      1427.5594482421875,
      "LAUNDRY",
      151,
      15,
      1
    ],
    [
      2130.552001953125,
      1414.31298828125,
      2157.406494140625,
      1427.5594482421875,
      "CHUTE",
      151,
      15,
      2
    ],
    [
      2159.574462890625,
      1414.31298828125,
      2198.562744140625,
      1427.5594482421875,
      "OVERRUN",
      151,
      15,
      3
    ],
    [
      2078.11767578125,
      1425.3863525390625,
      2088.958251953125,
      1438.6328125,
      "18.",
      151,
      16,
      0
    ],
    [
      2091.12646484375,
      1425.3863525390625,
      2116.687744140625,
      1438.6328125,
      "FINISH",
      151,
      16,
      1
    ],
    [
      2118.855712890625,
      1425.3863525390625,
      2156.978515625,
      1438.6328125,
      "CONTROL",
      151,
      16,
      2
    ],
    [
      2159.146728515625,
      1425.3863525390625,
      2181.67431640625,
      1438.6328125,
      "JOINT",
      151,
      16,
      3
    ],
    [
      2078.11767578125,
      1436.459716796875,
      2088.958251953125,
      1449.7061767578125,
      "19.",
      151,
      17,
      0
    ],
    [
      2091.12646484375,
      1436.459716796875,
      2135.75390625,
      1449.7061767578125,
      "OVERFLOW",
      151,
      17,
      1
    ],
    [
      2137.921875,
      1436.459716796875,
      2175.616943359375,
      1449.7061767578125,
      "SCUPPER",
      151,
      17,
      2
    ],
    [
      2177.784912109375,
      1436.459716796875,
      2180.380859375,
      1449.7061767578125,
      "-",
      151,
      17,
      3
    ],
    [
      2182.549072265625,
      1436.459716796875,
      2205.523681640625,
      1449.7061767578125,
      "BASIS",
      151,
      17,
      4
    ],
    [
      2207.69189453125,
      1436.459716796875,
      2218.52294921875,
      1449.7061767578125,
      "OF",
      151,
      17,
      5
    ],
    [
      2220.691162109375,
      1436.459716796875,
      2250.588623046875,
      1449.7061767578125,
      "DESIGN",
      151,
      17,
      6
    ],
    [
      2252.756591796875,
      1436.459716796875,
      2280.48583984375,
      1449.7061767578125,
      "NESCO",
      151,
      17,
      7
    ],
    [
      2282.65380859375,
      1436.459716796875,
      2299.97998046875,
      1449.7061767578125,
      "MFG",
      151,
      17,
      8
    ],
    [
      2302.14794921875,
      1436.459716796875,
      2317.743408203125,
      1449.7061767578125,
      "INC.",
      151,
      17,
      9
    ],
    [
      2319.91162109375,
      1436.459716796875,
      2322.507568359375,
      1449.7061767578125,
      "-",
      151,
      17,
      10
    ],
    [
      2324.67578125,
      1436.459716796875,
      2352.405029296875,
      1449.7061767578125,
      "MODEL",
      151,
      17,
      11
    ],
    [
      2078.11767578125,
      1447.5330810546875,
      2116.6875,
      1460.779541015625,
      "#SCT914R",
      151,
      18,
      0
    ],
    [
      2078.11767578125,
      1458.6064453125,
      2088.958251953125,
      1471.8529052734375,
      "20.",
      151,
      19,
      0
    ],
    [
      2091.12646484375,
      1458.6064453125,
      2123.619873046875,
      1471.8529052734375,
      "TAMPER",
      151,
      19,
      1
    ],
    [
      2125.787841796875,
      1458.6064453125,
      2171.718017578125,
      1471.8529052734375,
      "RESISTANT,",
      151,
      19,
      2
    ],
    [
      2173.88623046875,
      1458.6064453125,
      2216.78271484375,
      1471.8529052734375,
      "RECESSED",
      151,
      19,
      3
    ],
    [
      2218.95068359375,
      1458.6064453125,
      2241.050537109375,
      1471.8529052734375,
      "HOSE",
      151,
      19,
      4
    ],
    [
      2243.21875,
      1458.6064453125,
      2260.99169921875,
      1471.8529052734375,
      "BIBB",
      151,
      19,
      5
    ],
    [
      2263.15966796875,
      1458.6064453125,
      2265.755615234375,
      1471.8529052734375,
      "-",
      151,
      19,
      6
    ],
    [
      2267.923828125,
      1458.6064453125,
      2296.509033203125,
      1471.8529052734375,
      "MOUNT",
      151,
      19,
      7
    ],
    [
      2298.67724609375,
      1458.6064453125,
      2314.7099609375,
      1471.8529052734375,
      "TOP",
      151,
      19,
      8
    ],
    [
      2316.8779296875,
      1458.6064453125,
      2326.84375,
      1471.8529052734375,
      "AT",
      151,
      19,
      9
    ],
    [
      2329.01171875,
      1458.6064453125,
      2345.006591796875,
      1471.8529052734375,
      "+12\"",
      151,
      19,
      10
    ],
    [
      2078.11767578125,
      1469.679931640625,
      2097.183837890625,
      1482.9263916015625,
      "A.F.F",
      151,
      20,
      0
    ],
    [
      2078.11767578125,
      1480.7532958984375,
      2088.958251953125,
      1493.999755859375,
      "23.",
      151,
      21,
      0
    ],
    [
      2091.12646484375,
      1480.7532958984375,
      2129.2587890625,
      1493.999755859375,
      "SIGNAGE-",
      151,
      21,
      1
    ],
    [
      2131.427001953125,
      1480.7532958984375,
      2157.853515625,
      1493.999755859375,
      "REFER",
      151,
      21,
      2
    ],
    [
      2160.021484375,
      1480.7532958984375,
      2170.8525390625,
      1493.999755859375,
      "TO",
      151,
      21,
      3
    ],
    [
      2173.020751953125,
      1480.7532958984375,
      2212.884033203125,
      1493.999755859375,
      "EXTERIOR",
      151,
      21,
      4
    ],
    [
      2215.052001953125,
      1480.7532958984375,
      2256.218017578125,
      1493.999755859375,
      "SIGNANGE",
      151,
      21,
      5
    ],
    [
      2258.38623046875,
      1480.7532958984375,
      2323.38232421875,
      1493.999755859375,
      "SPECIFICATIONS",
      151,
      21,
      6
    ],
    [
      2078.11767578125,
      1491.82666015625,
      2088.958251953125,
      1505.0731201171875,
      "24.",
      151,
      22,
      0
    ],
    [
      2091.12646484375,
      1491.82666015625,
      2117.990478515625,
      1505.0731201171875,
      "KYNAR",
      151,
      22,
      1
    ],
    [
      2120.158447265625,
      1491.82666015625,
      2145.719482421875,
      1505.0731201171875,
      "FINISH",
      151,
      22,
      2
    ],
    [
      2147.8876953125,
      1491.82666015625,
      2191.64013671875,
      1505.0731201171875,
      "ALUMINIUM",
      151,
      22,
      3
    ],
    [
      2193.80810546875,
      1491.82666015625,
      2225.445556640625,
      1505.0731201171875,
      "GRAVEL",
      151,
      22,
      4
    ],
    [
      2227.61376953125,
      1491.82666015625,
      2248.84814453125,
      1505.0731201171875,
      "STOP",
      151,
      22,
      5
    ],
    [
      2251.016357421875,
      1491.82666015625,
      2253.6123046875,
      1505.0731201171875,
      "-",
      151,
      22,
      6
    ],
    [
      2255.780517578125,
      1491.82666015625,
      2283.510009765625,
      1505.0731201171875,
      "COLOR",
      151,
      22,
      7
    ],
    [
      2285.677978515625,
      1491.82666015625,
      2296.509033203125,
      1505.0731201171875,
      "TO",
      151,
      22,
      8
    ],
    [
      2298.67724609375,
      1491.82666015625,
      2326.39697265625,
      1505.0731201171875,
      "MATCH",
      151,
      22,
      9
    ],
    [
      2078.11767578125,
      1502.900146484375,
      2119.27392578125,
      1516.1466064453125,
      "ADJACENT",
      151,
      23,
      0
    ],
    [
      2121.442138671875,
      1502.900146484375,
      2160.439697265625,
      1516.1466064453125,
      "MATERIAL",
      151,
      23,
      1
    ],
    [
      2078.11767578125,
      1513.973388671875,
      2088.958251953125,
      1527.2198486328125,
      "30.",
      151,
      24,
      0
    ],
    [
      2091.12646484375,
      1513.973388671875,
      2114.09130859375,
      1527.2198486328125,
      "LIGHT",
      151,
      24,
      1
    ],
    [
      2116.259521484375,
      1513.973388671875,
      2149.618408203125,
      1527.2198486328125,
      "FIXTURE",
      151,
      24,
      2
    ],
    [
      2151.786376953125,
      1513.973388671875,
      2154.38232421875,
      1527.2198486328125,
      "-",
      151,
      24,
      3
    ],
    [
      2156.55078125,
      1513.973388671875,
      2182.977294921875,
      1527.2198486328125,
      "REFER",
      151,
      24,
      4
    ],
    [
      2185.145263671875,
      1513.973388671875,
      2195.976318359375,
      1527.2198486328125,
      "TO",
      151,
      24,
      5
    ],
    [
      2198.14453125,
      1513.973388671875,
      2229.344482421875,
      1527.2198486328125,
      "CEILING",
      151,
      24,
      6
    ],
    [
      2231.5126953125,
      1513.973388671875,
      2251.8818359375,
      1527.2198486328125,
      "PLAN",
      151,
      24,
      7
    ],
    [
      2078.11767578125,
      1525.046875,
      2088.958251953125,
      1538.2933349609375,
      "31.",
      151,
      25,
      0
    ],
    [
      2091.12646484375,
      1525.046875,
      2136.628662109375,
      1538.2933349609375,
      "EXPANSION",
      151,
      25,
      1
    ],
    [
      2138.796630859375,
      1525.046875,
      2161.32421875,
      1538.2933349609375,
      "JOINT",
      151,
      25,
      2
    ],
    [
      2163.492431640625,
      1525.046875,
      2173.458251953125,
      1538.2933349609375,
      "AT",
      151,
      25,
      3
    ],
    [
      2175.62646484375,
      1525.046875,
      2202.490234375,
      1538.2933349609375,
      "FLOOR",
      151,
      25,
      4
    ],
    [
      2204.658203125,
      1525.046875,
      2221.993896484375,
      1538.2933349609375,
      "LINE",
      151,
      25,
      5
    ],
    [
      2224.162109375,
      1525.046875,
      2244.084228515625,
      1538.2933349609375,
      "WITH",
      151,
      25,
      6
    ],
    [
      2246.252197265625,
      1525.046875,
      2278.317626953125,
      1538.2933349609375,
      "BACKER",
      151,
      25,
      7
    ],
    [
      2280.48583984375,
      1525.046875,
      2297.811767578125,
      1538.2933349609375,
      "ROD",
      151,
      25,
      8
    ],
    [
      2299.97998046875,
      1525.046875,
      2316.440673828125,
      1538.2933349609375,
      "AND",
      151,
      25,
      9
    ],
    [
      2318.608642578125,
      1525.046875,
      2354.145263671875,
      1538.2933349609375,
      "SEALANT",
      151,
      25,
      10
    ],
    [
      2078.11767578125,
      1536.1202392578125,
      2088.958251953125,
      1549.36669921875,
      "32.",
      151,
      26,
      0
    ],
    [
      2091.12646484375,
      1536.1202392578125,
      2134.87890625,
      1549.36669921875,
      "ALUMINIUM",
      151,
      26,
      1
    ],
    [
      2137.046875,
      1536.1202392578125,
      2169.112548828125,
      1549.36669921875,
      "LOUVER",
      151,
      26,
      2
    ],
    [
      2171.280517578125,
      1536.1202392578125,
      2173.87646484375,
      1549.36669921875,
      "-",
      151,
      26,
      3
    ],
    [
      2176.044921875,
      1536.1202392578125,
      2203.774169921875,
      1549.36669921875,
      "COLOR",
      151,
      26,
      4
    ],
    [
      2205.942138671875,
      1536.1202392578125,
      2216.773193359375,
      1549.36669921875,
      "TO",
      151,
      26,
      5
    ],
    [
      2218.94140625,
      1536.1202392578125,
      2246.6611328125,
      1549.36669921875,
      "MATCH",
      151,
      26,
      6
    ],
    [
      2248.8291015625,
      1536.1202392578125,
      2289.985595703125,
      1549.36669921875,
      "ADJACENT",
      151,
      26,
      7
    ],
    [
      2292.15380859375,
      1536.1202392578125,
      2331.1513671875,
      1549.36669921875,
      "MATERIAL",
      151,
      26,
      8
    ],
    [
      2078.11767578125,
      1547.193603515625,
      2119.701904296875,
      1560.4400634765625,
      "MATCHING",
      151,
      27,
      0
    ],
    [
      2121.8701171875,
      1547.193603515625,
      2163.0263671875,
      1560.4400634765625,
      "ADJACENT",
      151,
      27,
      1
    ],
    [
      2165.194580078125,
      1547.193603515625,
      2186.4287109375,
      1560.4400634765625,
      "WALL",
      151,
      27,
      2
    ],
    [
      2078.11767578125,
      1558.26708984375,
      2088.958251953125,
      1571.5135498046875,
      "33.",
      151,
      28,
      0
    ],
    [
      2091.12646484375,
      1558.26708984375,
      2127.9560546875,
      1571.5135498046875,
      "BUILDING",
      151,
      28,
      1
    ],
    [
      2130.124267578125,
      1558.26708984375,
      2159.583984375,
      1571.5135498046875,
      "HEIGHT",
      151,
      28,
      2
    ],
    [
      2161.752197265625,
      1558.26708984375,
      2211.143798828125,
      1571.5135498046875,
      "DIMENSIONS",
      151,
      28,
      3
    ],
    [
      2213.31201171875,
      1558.26708984375,
      2229.3447265625,
      1571.5135498046875,
      "ARE",
      151,
      28,
      4
    ],
    [
      2231.5126953125,
      1558.26708984375,
      2257.94873046875,
      1571.5135498046875,
      "BASED",
      151,
      28,
      5
    ],
    [
      2260.11669921875,
      1558.26708984375,
      2271.8134765625,
      1571.5135498046875,
      "ON",
      151,
      28,
      6
    ],
    [
      2273.9814453125,
      1558.26708984375,
      2299.105224609375,
      1571.5135498046875,
      "WOOD",
      151,
      28,
      7
    ],
    [
      2301.273193359375,
      1558.26708984375,
      2328.56494140625,
      1571.5135498046875,
      "FRAME",
      151,
      28,
      8
    ],
    [
      2078.11767578125,
      1569.34033203125,
      2143.094970703125,
      1582.5867919921875,
      "CONSTRUCTION.",
      151,
      29,
      0
    ],
    [
      2145.262939453125,
      1569.34033203125,
      2171.261474609375,
      1582.5867919921875,
      "THESE",
      151,
      29,
      1
    ],
    [
      2173.4296875,
      1569.34033203125,
      2222.8212890625,
      1582.5867919921875,
      "DIMENSIONS",
      151,
      29,
      2
    ],
    [
      2224.9892578125,
      1569.34033203125,
      2243.190185546875,
      1582.5867919921875,
      "WILL",
      151,
      29,
      3
    ],
    [
      2245.3583984375,
      1569.34033203125,
      2266.5927734375,
      1582.5867919921875,
      "VARY",
      151,
      29,
      4
    ],
    [
      2268.7607421875,
      1569.34033203125,
      2295.19677734375,
      1582.5867919921875,
      "BASED",
      151,
      29,
      5
    ],
    [
      2297.36474609375,
      1569.34033203125,
      2309.061279296875,
      1582.5867919921875,
      "ON",
      151,
      29,
      6
    ],
    [
      2311.2294921875,
      1569.34033203125,
      2333.3291015625,
      1582.5867919921875,
      "FINAL",
      151,
      29,
      7
    ],
    [
      2078.11767578125,
      1580.413818359375,
      2114.947265625,
      1593.6602783203125,
      "BUILDING",
      151,
      30,
      0
    ],
    [
      2117.115478515625,
      1580.413818359375,
      2182.0927734375,
      1593.6602783203125,
      "CONSTRUCTION.",
      151,
      30,
      1
    ],
    [
      2184.2607421875,
      1580.413818359375,
      2221.5185546875,
      1593.6602783203125,
      "INTERIOR",
      151,
      30,
      2
    ],
    [
      2223.6865234375,
      1580.413818359375,
      2254.88671875,
      1593.6602783203125,
      "CEILING",
      151,
      30,
      3
    ],
    [
      2257.0546875,
      1580.413818359375,
      2286.5146484375,
      1593.6602783203125,
      "HEIGHT",
      151,
      30,
      4
    ],
    [
      2288.682861328125,
      1580.413818359375,
      2338.074462890625,
      1593.6602783203125,
      "DIMENSIONS",
      151,
      30,
      5
    ],
    [
      2340.24267578125,
      1580.413818359375,
      2356.275390625,
      1593.6602783203125,
      "ARE",
      151,
      30,
      6
    ],
    [
      2078.11767578125,
      1591.4873046875,
      2113.644287109375,
      1604.7337646484375,
      "CRITICAL",
      151,
      31,
      0
    ],
    [
      2115.8125,
      1591.4873046875,
      2126.6435546875,
      1604.7337646484375,
      "TO",
      151,
      31,
      1
    ],
    [
      2128.81201171875,
      1591.4873046875,
      2166.069580078125,
      1604.7337646484375,
      "MAINTAIN",
      151,
      31,
      2
    ],
    [
      2168.237548828125,
      1591.4873046875,
      2178.640869140625,
      1604.7337646484375,
      "AS",
      151,
      31,
      3
    ],
    [
      2180.80908203125,
      1591.4873046875,
      2223.2587890625,
      1604.7337646484375,
      "MINIMUMS.",
      151,
      31,
      4
    ],
    [
      2078.11767578125,
      1602.560546875,
      2088.958251953125,
      1615.8070068359375,
      "36.",
      151,
      32,
      0
    ],
    [
      2091.12646484375,
      1602.560546875,
      2134.87890625,
      1615.8070068359375,
      "ALUMINIUM",
      151,
      32,
      1
    ],
    [
      2137.046875,
      1602.560546875,
      2169.10302734375,
      1615.8070068359375,
      "GUTTER",
      151,
      32,
      2
    ],
    [
      2171.27099609375,
      1602.560546875,
      2187.731689453125,
      1615.8070068359375,
      "AND",
      151,
      32,
      3
    ],
    [
      2189.89990234375,
      1602.560546875,
      2202.899169921875,
      1615.8070068359375,
      "DS.",
      151,
      32,
      4
    ],
    [
      2205.0673828125,
      1602.560546875,
      2232.796630859375,
      1615.8070068359375,
      "COLOR",
      151,
      32,
      5
    ],
    [
      2234.964599609375,
      1602.560546875,
      2245.795654296875,
      1615.8070068359375,
      "TO",
      151,
      32,
      6
    ],
    [
      2247.9638671875,
      1602.560546875,
      2275.68359375,
      1615.8070068359375,
      "MATCH",
      151,
      32,
      7
    ],
    [
      2277.8515625,
      1602.560546875,
      2294.749755859375,
      1615.8070068359375,
      "ADJ.",
      151,
      32,
      8
    ],
    [
      2296.91796875,
      1602.560546875,
      2335.915771484375,
      1615.8070068359375,
      "MATERIAL",
      151,
      32,
      9
    ],
    [
      2078.11767578125,
      1613.634033203125,
      2088.958251953125,
      1626.8804931640625,
      "37.",
      151,
      33,
      0
    ],
    [
      2091.12646484375,
      1613.634033203125,
      2140.099609375,
      1626.8804931640625,
      "ACCESSIBLE",
      151,
      33,
      1
    ],
    [
      2142.267578125,
      1613.634033203125,
      2157.87255859375,
      1626.8804931640625,
      "KEY",
      151,
      33,
      2
    ],
    [
      2160.04052734375,
      1613.634033203125,
      2182.130859375,
      1626.8804931640625,
      "CARD",
      151,
      33,
      3
    ],
    [
      2184.298828125,
      1613.634033203125,
      2216.792236328125,
      1626.8804931640625,
      "READER",
      151,
      33,
      4
    ],
    [
      2218.96044921875,
      1613.634033203125,
      2244.949462890625,
      1626.8804931640625,
      "WIRED",
      151,
      33,
      5
    ],
    [
      2247.117431640625,
      1613.634033203125,
      2257.948486328125,
      1626.8804931640625,
      "TO",
      151,
      33,
      6
    ],
    [
      2260.11669921875,
      1613.634033203125,
      2298.67724609375,
      1626.8804931640625,
      "ELECTRIC",
      151,
      33,
      7
    ],
    [
      2300.84521484375,
      1613.634033203125,
      2329.011962890625,
      1626.8804931640625,
      "STRIKE",
      151,
      33,
      8
    ],
    [
      2331.18017578125,
      1613.634033203125,
      2338.977783203125,
      1626.8804931640625,
      "IN",
      151,
      33,
      9
    ],
    [
      2078.11767578125,
      1624.707275390625,
      2101.5107421875,
      1637.9537353515625,
      "DOOR",
      151,
      34,
      0
    ],
    [
      2103.6787109375,
      1624.707275390625,
      2106.274658203125,
      1637.9537353515625,
      "-",
      151,
      34,
      1
    ],
    [
      2108.44287109375,
      1624.707275390625,
      2124.4755859375,
      1637.9537353515625,
      "TOP",
      151,
      34,
      2
    ],
    [
      2126.643798828125,
      1624.707275390625,
      2137.474853515625,
      1637.9537353515625,
      "OF",
      151,
      34,
      3
    ],
    [
      2139.64306640625,
      1624.707275390625,
      2172.136474609375,
      1637.9537353515625,
      "READER",
      151,
      34,
      4
    ],
    [
      2174.3046875,
      1624.707275390625,
      2184.270263671875,
      1637.9537353515625,
      "AT",
      151,
      34,
      5
    ],
    [
      2186.4384765625,
      1624.707275390625,
      2197.878173828125,
      1637.9537353515625,
      "48\"",
      151,
      34,
      6
    ],
    [
      2200.04638671875,
      1624.707275390625,
      2219.112548828125,
      1637.9537353515625,
      "MAX.",
      151,
      34,
      7
    ],
    [
      2221.28076171875,
      1624.707275390625,
      2250.74072265625,
      1637.9537353515625,
      "HEIGHT",
      151,
      34,
      8
    ],
    [
      2078.11767578125,
      1635.78076171875,
      2088.958251953125,
      1649.0272216796875,
      "38.",
      151,
      35,
      0
    ],
    [
      2091.12646484375,
      1635.78076171875,
      2112.798095703125,
      1649.0272216796875,
      "POOL",
      151,
      35,
      1
    ],
    [
      2114.96630859375,
      1635.78076171875,
      2160.458984375,
      1649.0272216796875,
      "PERIMETER",
      151,
      35,
      2
    ],
    [
      2162.626953125,
      1635.78076171875,
      2189.053466796875,
      1649.0272216796875,
      "FENCE",
      151,
      35,
      3
    ],
    [
      2191.2216796875,
      1635.78076171875,
      2201.625,
      1649.0272216796875,
      "AS",
      151,
      35,
      4
    ],
    [
      2203.79296875,
      1635.78076171875,
      2244.949462890625,
      1649.0272216796875,
      "REQUIRED",
      151,
      35,
      5
    ],
    [
      2247.117431640625,
      1635.78076171875,
      2257.520751953125,
      1649.0272216796875,
      "BY",
      151,
      35,
      6
    ],
    [
      2259.68896484375,
      1635.78076171875,
      2282.216552734375,
      1649.0272216796875,
      "CODE",
      151,
      35,
      7
    ],
    [
      2284.384521484375,
      1635.78076171875,
      2304.306884765625,
      1649.0272216796875,
      "WITH",
      151,
      35,
      8
    ],
    [
      2306.474853515625,
      1635.78076171875,
      2322.003662109375,
      1649.0272216796875,
      "3'-0\"",
      151,
      35,
      9
    ],
    [
      2324.171630859375,
      1635.78076171875,
      2345.40625,
      1649.0272216796875,
      "GATE",
      151,
      35,
      10
    ],
    [
      2078.11767578125,
      1646.8541259765625,
      2088.958251953125,
      1660.1005859375,
      "39.",
      151,
      36,
      0
    ],
    [
      2091.12646484375,
      1646.8541259765625,
      2127.9560546875,
      1660.1005859375,
      "PRECAST",
      151,
      36,
      1
    ],
    [
      2130.1240234375,
      1646.8541259765625,
      2160.88671875,
      1660.1005859375,
      "COPING",
      151,
      36,
      2
    ],
    [
      2078.11767578125,
      1219.8970947265625,
      2142.591064453125,
      1245.8575439453125,
      "KEYED",
      152,
      0,
      0
    ],
    [
      2147.87841796875,
      1219.8970947265625,
      2213.39794921875,
      1245.8575439453125,
      "NOTES",
      152,
      0,
      1
    ]
  ],
  "blocks": [
    [
      356.13995361328125,
      194.20814514160156,
      1025.349609375,
      220.168701171875,
      "A\nB\nC\nD\nE\nF\nG\nH\nJ\nJ.1\n",
      0,
      0
    ],
    [
      1034.9056396484375,
      781.5574951171875,
      1117.6370849609375,
      798.6368408203125,
      "FIRST FLOOR\n",
      1,
      0
    ],
    [
      1086.392578125,
      794.892333984375,
      1118.261474609375,
      811.9716796875,
      "0' - 0\"\n",
      2,
      0
    ],
    [
      1017.6256103515625,
      667.4451904296875,
      1117.7366943359375,
      684.5245361328125,
      "SECOND FLOOR\n",
      3,
      0
    ],
    [
      1079.4407958984375,
      680.780029296875,
      1118.2666015625,
      697.859375,
      "12' - 8\"\n",
      4,
      0
    ],
    [
      1033.0045166015625,
      580.3594360351562,
      1117.81298828125,
      597.4387817382812,
      "THIRD FLOOR\n",
      5,
      0
    ],
    [
      1079.4407958984375,
      593.6943359375,
      1118.2666015625,
      610.773681640625,
      "22' - 4\"\n",
      6,
      0
    ],
    [
      1019.1295166015625,
      493.27374267578125,
      1117.839111328125,
      510.35302734375,
      "FOURTH FLOOR\n",
      7,
      0
    ],
    [
      1079.4407958984375,
      506.608642578125,
      1118.2666015625,
      523.68798828125,
      "32' - 0\"\n",
      8,
      0
    ],
    [
      1035.643310546875,
      406.18804931640625,
      1117.674072265625,
      423.267333984375,
      "FIFTH FLOOR\n",
      9,
      0
    ],
    [
      1079.4407958984375,
      419.52288818359375,
      1118.2666015625,
      436.6022033691406,
      "41' - 8\"\n",
      10,
      0
    ],
    [
      1045.4041748046875,
      319.102294921875,
      1117.712890625,
      336.1816101074219,
      "ROOF PLAN\n",
      11,
      0
    ],
    [
      1079.4407958984375,
      332.43719482421875,
      1118.2666015625,
      349.5165100097656,
      "51' - 4\"\n",
      12,
      0
    ],
    [
      1038.0836181640625,
      292.07568359375,
      1117.34912109375,
      309.1549987792969,
      "TO PARAPET\n",
      13,
      0
    ],
    [
      1079.4407958984375,
      305.41058349609375,
      1118.2666015625,
      322.4898986816406,
      "54' - 4\"\n",
      14,
      0
    ],
    [
      333.80548095703125,
      194.20814514160156,
      359.17645263671875,
      220.168701171875,
      "J.2\n",
      15,
      0
    ],
    [
      235.5478515625,
      967.15380859375,
      1884.99365234375,
      993.1143798828125,
      "1\n2\n3\n4\n5\n6\n7\n8\n9\n10\n11\n12\n13\n14\n15\n",
      16,
      0
    ],
    [
      1935.293701171875,
      1554.5262451171875,
      2018.02490234375,
      1571.6055908203125,
      "FIRST FLOOR\n",
      17,
      0
    ],
    [
      1986.780517578125,
      1567.8612060546875,
      2018.6494140625,
      1584.9405517578125,
      "0' - 0\"\n",
      18,
      0
    ],
    [
      1918.013671875,
      1440.4139404296875,
      2018.12451171875,
      1457.4932861328125,
      "SECOND FLOOR\n",
      19,
      0
    ],
    [
      1979.828857421875,
      1453.7489013671875,
      2018.654541015625,
      1470.8282470703125,
      "12' - 8\"\n",
      20,
      0
    ],
    [
      1933.392578125,
      1353.3282470703125,
      2018.200927734375,
      1370.4075927734375,
      "THIRD FLOOR\n",
      21,
      0
    ],
    [
      1979.828857421875,
      1366.6632080078125,
      2018.654541015625,
      1383.7425537109375,
      "22' - 4\"\n",
      22,
      0
    ],
    [
      1919.5174560546875,
      1266.2425537109375,
      2018.22705078125,
      1283.3218994140625,
      "FOURTH FLOOR\n",
      23,
      0
    ],
    [
      1979.828857421875,
      1279.5775146484375,
      2018.654541015625,
      1296.6568603515625,
      "32' - 0\"\n",
      24,
      0
    ],
    [
      1936.0313720703125,
      1179.1568603515625,
      2018.06201171875,
      1196.2362060546875,
      "FIFTH FLOOR\n",
      25,
      0
    ],
    [
      1979.828857421875,
      1192.49169921875,
      2018.654541015625,
      1209.571044921875,
      "41' - 8\"\n",
      26,
      0
    ],
    [
      1945.792236328125,
      1092.0711669921875,
      2018.100830078125,
      1109.1505126953125,
      "ROOF PLAN\n",
      27,
      0
    ],
    [
      1979.828857421875,
      1105.406005859375,
      2018.654541015625,
      1122.4853515625,
      "51' - 4\"\n",
      28,
      0
    ],
    [
      1938.4715576171875,
      1065.0445556640625,
      2017.7369384765625,
      1082.1239013671875,
      "TO PARAPET\n",
      29,
      0
    ],
    [
      1979.828857421875,
      1078.37939453125,
      2018.654541015625,
      1095.458740234375,
      "54' - 4\"\n",
      30,
      0
    ],
    [
      565.3025512695312,
      1147.66015625,
      1825.9066162109375,
      1160.9066162109375,
      "8\n8\n8\n8\n8\n8\n8\n8\n8\n8\n8\n8\n",
      31,
      0
    ],
    [
      565.3025512695312,
      1234.745849609375,
      1825.9066162109375,
      1247.9923095703125,
      "8\n8\n8\n8\n8\n8\n8\n8\n8\n8\n8\n8\n",
      32,
      0
    ],
    [
      565.3025512695312,
      1321.83154296875,
      1825.9066162109375,
      1335.0780029296875,
      "8\n8\n8\n8\n8\n8\n8\n8\n8\n8\n8\n8\n",
      33,
      0
    ],
    [
      565.3025512695312,
      1408.917236328125,
      1825.9066162109375,
      1422.1636962890625,
      "8\n8\n8\n8\n8\n8\n8\n8\n8\n8\n8\n8\n",
      34,
      0
    ],
    [
      1020.2503051757812,
      1521.528076171875,
      1823.9593505859375,
      1536.2760009765625,
      "8\n8\n8\n8\n8\n10\n",
      35,
      0
    ],
    [
      298.64959716796875,
      1321.83154296875,
      320.3214416503906,
      1335.0780029296875,
      "EX - 2\n",
      36,
      0
    ],
    [
      891.798095703125,
      1090.1224365234375,
      913.4699096679688,
      1103.368896484375,
      "EX - 2\n",
      37,
      0
    ],
    [
      559.0689086914062,
      1521.528076171875,
      1148.2994384765625,
      1534.7745361328125,
      "EX - 1\nEX - 1\n",
      38,
      0
    ],
    [
      1126.6275634765625,
      1457.71533203125,
      1148.2994384765625,
      1470.9617919921875,
      "EX - 5\n",
      39,
      0
    ],
    [
      1126.6275634765625,
      1370.6295166015625,
      1148.2994384765625,
      1383.8759765625,
      "EX - 5\n",
      40,
      0
    ],
    [
      1126.6275634765625,
      1283.5438232421875,
      1148.2994384765625,
      1296.790283203125,
      "EX - 5\n",
      41,
      0
    ],
    [
      1126.6275634765625,
      1196.4581298828125,
      1148.2994384765625,
      1209.70458984375,
      "EX - 5\n",
      42,
      0
    ],
    [
      1126.6275634765625,
      1109.3724365234375,
      1148.2994384765625,
      1122.618896484375,
      "EX - 5\n",
      43,
      0
    ],
    [
      587.5969848632812,
      1457.71533203125,
      609.268798828125,
      1470.9617919921875,
      "EX - 5\n",
      44,
      0
    ],
    [
      587.5969848632812,
      1370.6295166015625,
      609.268798828125,
      1383.8759765625,
      "EX - 5\n",
      45,
      0
    ],
    [
      587.5969848632812,
      1283.5438232421875,
      609.268798828125,
      1296.790283203125,
      "EX - 5\n",
      46,
      0
    ],
    [
      587.5969848632812,
      1196.4581298828125,
      609.268798828125,
      1209.70458984375,
      "EX - 5\n",
      47,
      0
    ],
    [
      587.5969848632812,
      1109.3724365234375,
      609.268798828125,
      1122.618896484375,
      "EX - 5\n",
      48,
      0
    ],
    [
      958.170654296875,
      1242.253173828125,
      979.8424072265625,
      1255.4996337890625,
      "EX - 1\n",
      49,
      0
    ],
    [
      1284.197265625,
      1297.1966552734375,
      1561.2376708984375,
      1310.443115234375,
      "EX - 2\nEX - 3\nEX - 2\n",
      50,
      0
    ],
    [
      1699.253662109375,
      1457.71533203125,
      1720.925537109375,
      1470.9617919921875,
      "EX - 5\n",
      51,
      0
    ],
    [
      1699.253662109375,
      1370.6295166015625,
      1720.925537109375,
      1383.8759765625,
      "EX - 5\n",
      52,
      0
    ],
    [
      1699.253662109375,
      1283.5438232421875,
      1720.925537109375,
      1296.790283203125,
      "EX - 5\n",
      53,
      0
    ],
    [
      1699.253662109375,
      1196.4581298828125,
      1720.925537109375,
      1209.70458984375,
      "EX - 5\n",
      54,
      0
    ],
    [
      1699.253662109375,
      1109.3724365234375,
      1720.925537109375,
      1122.618896484375,
      "EX - 5\n",
      55,
      0
    ],
    [
      1692.64892578125,
      1090.1224365234375,
      1714.3206787109375,
      1103.368896484375,
      "EX - 2\n",
      56,
      0
    ],
    [
      1759.959716796875,
      1242.253173828125,
      1781.631591796875,
      1255.4996337890625,
      "EX - 1\n",
      57,
      0
    ],
    [
      1380.47802734375,
      1043.169921875,
      1766.0262451171875,
      1056.4163818359375,
      "19\n25\n18\n19\n19\n",
      58,
      0
    ],
    [
      1608.5205078125,
      1111.690673828125,
      1617.1929931640625,
      1124.9371337890625,
      "18\n",
      59,
      0
    ],
    [
      1608.5205078125,
      1198.7763671875,
      1617.1929931640625,
      1212.0228271484375,
      "18\n",
      60,
      0
    ],
    [
      1608.5205078125,
      1285.862060546875,
      1617.1929931640625,
      1299.1085205078125,
      "18\n",
      61,
      0
    ],
    [
      1608.5205078125,
      1372.94775390625,
      1617.1929931640625,
      1386.1942138671875,
      "18\n",
      62,
      0
    ],
    [
      1608.5205078125,
      1460.0335693359375,
      1617.1929931640625,
      1473.280029296875,
      "18\n",
      63,
      0
    ],
    [
      773.3628540039062,
      1020.572509765625,
      1098.3067626953125,
      1033.8189697265625,
      "24\n19\n19\n",
      64,
      0
    ],
    [
      1757.6705322265625,
      1539.5457763671875,
      1779.3424072265625,
      1552.792236328125,
      "EX - 1\n",
      65,
      0
    ],
    [
      1204.565185546875,
      80.22163391113281,
      1533.4083251953125,
      119.96124267578125,
      "ARCHITECTURAL ELEMENTS\n",
      66,
      0
    ],
    [
      1331.6619873046875,
      139.6658477783203,
      1552.8836669921875,
      223.37522888183594,
      "CORE: body\nBackground for layering of all other \nmaterials\nWRAP: Unified element set proud (12\" min)\nfrom the CORE\n",
      67,
      0
    ],
    [
      1331.6619873046875,
      234.8219757080078,
      1543.1019287109375,
      270.95318603515625,
      "LINK: Connection Piece to break up large\nsegments of the WRAP\n",
      68,
      0
    ],
    [
      1331.6619873046875,
      282.4000549316406,
      1557.1297607421875,
      401.58172607421875,
      "KEEP: foreground element of BEACON\nstands most proud of all  building surfaces.\nPlaced on primary building entry elevation in\nconjunction with the porte cochere and with\nclear visibility from the frontage road.\nExtends up beyond the WRAP. Background\nfor primary building sign.\n",
      69,
      0
    ],
    [
      1331.6619873046875,
      413.0285949707031,
      1540.7757568359375,
      482.38006591796875,
      "ACCENT BAND: articulation\nHorizontal 3D band proud of CORE.\nSufficient depth (2\" min) to create distinct\nshadow line. No visible joints.\n",
      70,
      0
    ],
    [
      1331.6619873046875,
      493.8268127441406,
      1418.5194091796875,
      513.3480224609375,
      "SUPPORT: base\n",
      71,
      0
    ],
    [
      1331.6619873046875,
      524.7947387695312,
      1424.237060546875,
      544.3159790039062,
      "PORT COCHERE\n",
      72,
      0
    ],
    [
      1331.6619873046875,
      555.7626953125,
      1558.1361083984375,
      642.86181640625,
      "BEACON: vertical element. Set above and\nback in plane from the KEEP, extends to the\nground. Composed of two element s each in\nBrand's iconic green (PMS 383 C / BM 398\nflower power):\n",
      73,
      0
    ],
    [
      1331.6619873046875,
      652.5885009765625,
      1559.063720703125,
      688.7198486328125,
      "REVEAL: vertical element extending through\nthe KEEP. Highest above all.\n",
      74,
      0
    ],
    [
      1331.6619873046875,
      699.0404052734375,
      1560.324951171875,
      735.1717529296875,
      "BEAM: vertical recess from the ground to the\nREVEAL.\n",
      75,
      0
    ],
    [
      1290.50244140625,
      139.34347534179688,
      1316.049560546875,
      159.18699645996094,
      "EX-1\n",
      76,
      0
    ],
    [
      1290.50244140625,
      186.92153930664062,
      1316.049560546875,
      206.7650604248047,
      "EX-2\n",
      77,
      0
    ],
    [
      1290.50244140625,
      234.49960327148438,
      1316.049560546875,
      254.34312438964844,
      "EX-3\n",
      78,
      0
    ],
    [
      1290.50244140625,
      282.0776672363281,
      1316.049560546875,
      301.92120361328125,
      "EX-4\n",
      79,
      0
    ],
    [
      1290.50244140625,
      412.70623779296875,
      1316.049560546875,
      432.5497741699219,
      "EX-5\n",
      80,
      0
    ],
    [
      1290.50244140625,
      493.5044250488281,
      1316.049560546875,
      513.3479614257812,
      "EX-6\n",
      81,
      0
    ],
    [
      1290.50244140625,
      524.4723510742188,
      1316.049560546875,
      544.31591796875,
      "EX-7\n",
      82,
      0
    ],
    [
      1290.50244140625,
      555.4403076171875,
      1316.049560546875,
      575.2838745117188,
      "EX-8\n",
      83,
      0
    ],
    [
      1570.08544921875,
      80.22163391113281,
      1889.8851318359375,
      119.96124267578125,
      "PROTOTYPICAL MATERIALS\n",
      84,
      0
    ],
    [
      1561.0765380859375,
      139.34353637695312,
      1616.6273193359375,
      175.7971649169922,
      "SUPPORT\nMateriality:\n",
      85,
      0
    ],
    [
      1561.0765380859375,
      206.10621643066406,
      1603.2301025390625,
      242.23753356933594,
      "Color:\nTexture:\n",
      86,
      0
    ],
    [
      1561.0765380859375,
      255.93641662597656,
      1607.7005615234375,
      275.4576416015625,
      "Contrast:\n",
      87,
      0
    ],
    [
      1561.0765380859375,
      305.4444885253906,
      1616.6273193359375,
      341.89813232421875,
      "CORE\nMateriality:\n",
      88,
      0
    ],
    [
      1561.0765380859375,
      388.8172912597656,
      1591.7247314453125,
      408.3385009765625,
      "Color:\n",
      89,
      0
    ],
    [
      1561.0765380859375,
      422.0373840332031,
      1607.7005615234375,
      458.1687316894531,
      "Texture:\nContrast:\n",
      90,
      0
    ],
    [
      1561.0765380859375,
      504.7655334472656,
      1616.6273193359375,
      541.21923828125,
      "WRAP\nMateriality:\n",
      91,
      0
    ],
    [
      1561.0765380859375,
      571.5281982421875,
      1607.7005615234375,
      624.2697143554688,
      "Color:\nTexture:\nContrast:\n",
      92,
      0
    ],
    [
      1561.0765380859375,
      670.8665161132812,
      1633.8642578125,
      707.3201904296875,
      "LINK & KEEP\nMateriality:\n",
      93,
      0
    ],
    [
      1561.0765380859375,
      754.2392578125,
      1591.7247314453125,
      773.760498046875,
      "Color:\n",
      94,
      0
    ],
    [
      1561.0765380859375,
      787.4594116210938,
      1607.7005615234375,
      823.5907592773438,
      "Texture:\nContrast:\n",
      95,
      0
    ],
    [
      1973.062744140625,
      151.44912719726562,
      2028.6134033203125,
      204.5128631591797,
      "ACCENT\nBAND\nMateriality:\n",
      96,
      0
    ],
    [
      1973.062744140625,
      218.2117462158203,
      2003.7108154296875,
      237.7329559326172,
      "Color:\n",
      97,
      0
    ],
    [
      1973.062744140625,
      251.4318389892578,
      2019.6864013671875,
      287.56317138671875,
      "Texture:\nContrast:\n",
      98,
      0
    ],
    [
      1973.062744140625,
      334.1601257324219,
      2030.51904296875,
      387.2237854003906,
      "PORTE\nCOCHERE\nMateriality:\n",
      99,
      0
    ],
    [
      1973.062744140625,
      400.9228210449219,
      2003.7108154296875,
      420.44403076171875,
      "Color:\n",
      100,
      0
    ],
    [
      1973.062744140625,
      434.1429138183594,
      2015.2161865234375,
      453.66412353515625,
      "Texture:\n",
      101,
      0
    ],
    [
      1641.2916259765625,
      156.27577209472656,
      1954.9058837890625,
      292.0675048828125,
      "Building material authentic and substantial material with clean\ncrisp lines such as tile, cut stone, cast stone, decorative\nmasonry units (cmu) or brick\nLight to Medium value,natural inherent in the material\nSandstone-like, ground face, bush hammered or smooth\nHigh textural contrast to WRAP and ACCENT BAND.\nMedium color contrast to all other elements. High material\ncontrast to all other elements.\n",
      102,
      0
    ],
    [
      1641.2916259765625,
      322.3766784667969,
      1946.637451171875,
      491.3888244628906,
      "Building material with strong directionality and high\nrelief to create shade and shadow such as textured EIFS,\nstucco, brick wood Siding, cement fiber board or corrugated\nmetal\nMedium value, 40-60% value, earth toned,painted or natural\ndepending on material\nMedium to coarse texture\nHigh textural contrast to WRAP and ACCENT BAND.\nMedium to High to WRAP and ACCENT BAND. Low to\nmedium material contrast to WRAP & ACCENT BAND\n",
      103,
      0
    ],
    [
      1641.2916259765625,
      521.6978149414062,
      1944.67578125,
      657.4896850585938,
      "Building material with a minimal amount of joints and\nconnections and a smooth finish such as EIFS, stucco or\nmetal panels\nLight to medium value, painted\nSmooth or Fine finish\nLow textural contrast to SUPPORT. Medium to high textural\ncontrast to CORE, Low to High contrast to SUPPORT and\nACCENT BAND. Low to High material contrast to CORE\n",
      104,
      0
    ],
    [
      1641.2916259765625,
      687.798828125,
      1955.5224609375,
      856.8109130859375,
      "Building material with a strong horizontal direction and high\nrelief to create shade and shadow. Smooth finish material:\nEIFS and stucco. Strong horizontal materials: brick, wood\ncement fiber board or metal\nMedium to Dark value, painted or natural depending\non material\nSmooth to Coarse\nLow to High textural contrast to WRAP and ACCENT BAND,\nHigh color contrast to WRAP. Low to High material contrast to\nWRAP.\n",
      105,
      0
    ],
    [
      2053.277587890625,
      184.99159240722656,
      2331.744873046875,
      320.7833251953125,
      "Building material with a minimum amount of joints and\nconnections and smooth finish: metal, EIFS or Stucco.\nLight to Dark value. Color must match or complement\nwindow and door frames throughout the design\nSmooth of Fine finish\nLow textural contrast to WRAP. Medium to High color\ncontrast to WRAP and CORE. Low material contrast to\nWRAP. Low to High material contrast to CORE.\n",
      106,
      0
    ],
    [
      2053.277587890625,
      367.7024841308594,
      2324.738037109375,
      453.6640930175781,
      "Steel columns and beams with T&G wood plank soffit\nand insulation for slope and membrane roofing.\nDark value on steel, wood plank to be clear stain, \nmembrane roofing color to match main roof.\nSmooth, painted finish.\n",
      107,
      0
    ],
    [
      2375.615234375,
      1428.5606689453125,
      2460.98095703125,
      1452.8804931640625,
      "KRISTOPHER PELOW  \nAR99671 & ID 6707\n",
      108,
      0
    ],
    [
      2372.92138671875,
      1204.083251953125,
      2415.39013671875,
      1217.3297119140625,
      "REVISIONS\n",
      109,
      0
    ],
    [
      2375.615234375,
      1474.84326171875,
      2457.947509765625,
      1510.2364501953125,
      "PROJECT NO:\nDRAWN BY: KJP\nCHECKED BY: KJP/EC\n",
      110,
      0
    ],
    [
      2487.87109375,
      370.6889953613281,
      2501.11767578125,
      547.56298828125,
      "205 N. Orange Ave, Suite 301, Sarasota, FL 34236\n",
      111,
      0
    ],
    [
      2347.4072265625,
      207.92636108398438,
      2364.486328125,
      767.4085693359375,
      "DESIGN/BUILDER: \nARCHITECT: \nHOTEL BRAND: \n",
      112,
      0
    ],
    [
      2461.993896484375,
      109.6048355102539,
      2475.240478515625,
      286.47845458984375,
      "205 N. Orange Ave, Suite 301, Sarasota, FL 34236\n",
      113,
      0
    ],
    [
      2375.615234375,
      1618.4561767578125,
      2452.82861328125,
      1669.694091796875,
      "A4.2\n",
      114,
      0
    ],
    [
      2375.615234375,
      1539.6614990234375,
      2495.05322265625,
      1565.6219482421875,
      "ELEVATIONS\n",
      115,
      0
    ],
    [
      2399.079833984375,
      901.2960205078125,
      2433.238525390625,
      1094.586181640625,
      "HOME 2 SUITES\n",
      116,
      0
    ],
    [
      2437.09033203125,
      853.220703125,
      2454.16943359375,
      1143.8441162109375,
      "90% CONSTRUCTION DOCUMENTS -  04.30.2025\n",
      117,
      0
    ],
    [
      2465.547119140625,
      946.6051025390625,
      2482.626220703125,
      1050.194580078125,
      "BRADENTON, FL.\n",
      118,
      0
    ],
    [
      2437.225830078125,
      1474.84326171875,
      2463.243408203125,
      1488.0897216796875,
      "210729\n",
      119,
      0
    ],
    [
      114.8919677734375,
      833.5369262695312,
      212.83526611328125,
      865.1387939453125,
      " 1/8\" = 1'-0\"\n1\nElevation 3 - a\n",
      120,
      0
    ],
    [
      114.8919677734375,
      1642.450439453125,
      212.83526611328125,
      1674.0523681640625,
      " 1/8\" = 1'-0\"\n2\nElevation 4 - a\n",
      121,
      0
    ],
    [
      2373.92431640625,
      1219.7752685546875,
      2511.6962890625,
      1232.755615234375,
      "No.\nDescription\nDate\n",
      122,
      0
    ],
    [
      469.7718505859375,
      277.0003662109375,
      491.4436950683594,
      290.24688720703125,
      "EX - 8\n",
      123,
      0
    ],
    [
      469.7718505859375,
      313.03582763671875,
      491.4436950683594,
      326.2823486328125,
      "EX - 2\n",
      124,
      0
    ],
    [
      566.0050659179688,
      335.25299072265625,
      587.6768798828125,
      348.49951171875,
      "EX - 5\n",
      125,
      0
    ],
    [
      375.82232666015625,
      524.0499267578125,
      397.4941711425781,
      537.2964477539062,
      "EX - 2\n",
      126,
      0
    ],
    [
      566.0050659179688,
      422.3387145996094,
      587.6768798828125,
      435.5852355957031,
      "EX - 5\n",
      127,
      0
    ],
    [
      566.0050659179688,
      509.4244384765625,
      587.6768798828125,
      522.6709594726562,
      "EX - 5\n",
      128,
      0
    ],
    [
      566.0050659179688,
      596.5101318359375,
      587.6768798828125,
      609.7566528320312,
      "EX - 5\n",
      129,
      0
    ],
    [
      520.4968872070312,
      684.7273559570312,
      542.168701171875,
      697.973876953125,
      "EX - 2\n",
      130,
      0
    ],
    [
      469.7718505859375,
      379.4800109863281,
      491.4436950683594,
      392.7265319824219,
      "EX - 1\n",
      131,
      0
    ],
    [
      469.7718505859375,
      469.56866455078125,
      491.4436950683594,
      482.815185546875,
      "EX - 1\n",
      132,
      0
    ],
    [
      469.7718505859375,
      554.008056640625,
      491.4436950683594,
      567.2545776367188,
      "EX - 1\n",
      133,
      0
    ],
    [
      469.7718505859375,
      640.5706176757812,
      491.4436950683594,
      653.817138671875,
      "EX - 1\n",
      134,
      0
    ],
    [
      659.5278930664062,
      423.76605224609375,
      668.2003784179688,
      437.0125732421875,
      "18\n",
      135,
      0
    ],
    [
      659.5278930664062,
      336.25299072265625,
      668.2003784179688,
      349.49951171875,
      "18\n",
      136,
      0
    ],
    [
      659.5278930664062,
      510.5889892578125,
      668.2003784179688,
      523.8355102539062,
      "18\n",
      137,
      0
    ],
    [
      659.5278930664062,
      597.691650390625,
      668.2003784179688,
      610.9381713867188,
      "18\n",
      138,
      0
    ],
    [
      659.5278930664062,
      687.7802734375,
      668.2003784179688,
      701.0267944335938,
      "18\n",
      139,
      0
    ],
    [
      802.5079345703125,
      379.4800109863281,
      824.1796875,
      392.7265319824219,
      "EX - 3\n",
      140,
      0
    ],
    [
      802.5079345703125,
      466.76470947265625,
      824.1796875,
      480.01123046875,
      "EX - 3\n",
      141,
      0
    ],
    [
      802.5079345703125,
      553.4650268554688,
      824.1796875,
      566.7115478515625,
      "EX - 3\n",
      142,
      0
    ],
    [
      802.5079345703125,
      643.5537109375,
      824.1796875,
      656.8002319335938,
      "EX - 3\n",
      143,
      0
    ],
    [
      916.3543701171875,
      524.0499267578125,
      938.026123046875,
      537.2964477539062,
      "EX - 2\n",
      144,
      0
    ],
    [
      617.1573486328125,
      747.4993896484375,
      638.8291625976562,
      760.7459106445312,
      "EX - 6\n",
      145,
      0
    ],
    [
      720.7291259765625,
      370.51715087890625,
      729.401611328125,
      383.763671875,
      "10\n",
      146,
      0
    ],
    [
      720.7291259765625,
      460.6058349609375,
      729.401611328125,
      473.85235595703125,
      "10\n",
      147,
      0
    ],
    [
      720.7291259765625,
      544.8720703125,
      729.401611328125,
      558.1185913085938,
      "10\n",
      148,
      0
    ],
    [
      720.7291259765625,
      632.0452880859375,
      729.401611328125,
      645.2918090820312,
      "10\n",
      149,
      0
    ],
    [
      473.82879638671875,
      741.9723510742188,
      478.1650695800781,
      755.2188720703125,
      "9\n",
      150,
      0
    ],
    [
      2078.11767578125,
      1248.2119140625,
      2358.443603515625,
      1660.1005859375,
      "1. APPROXIMATE LINE OF GRADE\n2. ABOVE GRADE EXPOSED FOUNDATION WALL\n4. PAINTED TUBE STEEL CANOPY WITH WOOD FINISHED SOFFIT\n5. MODIFIED WOOD CANOPY WITH STEEL SUPPORT\n6. MECHANICAL EQUIPMENT SCREEN - REVIEW ALL VIEWS AROUND \nPROPERTY BEFORE LOCATING ALL ROOF TOP MECHANICAL UNITS. \nVERIFY ALL EQUIPMENT IS ADEQUATELY SCREENED.\n8. ALUMINIUM FIXED WINDOW WITH THERMAL BROKEN FRAME, \nINSULATED GLAZING WITH INTEGRAL ALUMINIUM LOUVER AT PTAC \nUNITS.\n9. ALUMINIUM STOREFRONT SYSTEM WITH THERMAL BROKEN FRAME \nAND INSULATED GLAZING\n10. ALUMINIUM FIXED WINDOW WITH THERMAL BROKEN FRAME AND \nINSULATED GLAZING\n11. ELEVATOR OVERRUN\n13. LAUNDRY CHUTE OVERRUN\n18. FINISH CONTROL JOINT\n19. OVERFLOW SCUPPER - BASIS OF DESIGN NESCO MFG INC. - MODEL \n#SCT914R\n20. TAMPER RESISTANT, RECESSED HOSE BIBB - MOUNT TOP AT +12\" \nA.F.F\n23. SIGNAGE- REFER TO EXTERIOR SIGNANGE SPECIFICATIONS\n24. KYNAR FINISH ALUMINIUM GRAVEL STOP - COLOR TO MATCH \nADJACENT MATERIAL\n30. LIGHT FIXTURE - REFER TO CEILING PLAN\n31. EXPANSION JOINT AT FLOOR LINE WITH BACKER ROD AND SEALANT\n32. ALUMINIUM LOUVER - COLOR TO MATCH ADJACENT MATERIAL \nMATCHING ADJACENT WALL\n33. BUILDING HEIGHT DIMENSIONS ARE BASED ON WOOD FRAME \nCONSTRUCTION. THESE DIMENSIONS WILL VARY BASED ON FINAL \nBUILDING CONSTRUCTION. INTERIOR CEILING HEIGHT DIMENSIONS ARE \nCRITICAL TO MAINTAIN AS MINIMUMS.\n36. ALUMINIUM GUTTER AND DS. COLOR TO MATCH ADJ. MATERIAL\n37. ACCESSIBLE KEY CARD READER WIRED TO ELECTRIC STRIKE IN \nDOOR - TOP OF READER AT 48\" MAX. HEIGHT\n38. POOL PERIMETER FENCE AS REQUIRED BY CODE WITH 3'-0\" GATE\n39. PRECAST COPING\n",
      151,
      0
    ],
    [
      2078.11767578125,
      1219.8970947265625,
      2213.39794921875,
      1245.8575439453125,
      "KEYED NOTES\n",
      152,
      0
    ]
  ]
}