{
  "sheet": "A4.2",
  "coordinateSpace": {
    "width": 1920,
    "height": 1280
  },
  "calibration": {
    "pixelsPerFoot": 6.666666666666667,
    "printedScale": "1/8 inch = 1 foot",
    "checks": [
      {
        "view": "Printed1/8 inch at72PDF points/inch",
        "pixelsPerFoot": 6.666666666666667
      },
      {
        "view": "First-floor datum difference12ft8",
        "sourcePixels": 84.53,
        "referenceFeet": 12.666666666666666,
        "pixelsPerFoot": 6.673421052631579
      },
      {
        "view": "Upper-floor datum difference9ft8",
        "sourcePixels": 64.51,
        "referenceFeet": 9.666666666666666,
        "pixelsPerFoot": 6.67344827586207
      }
    ]
  },
  "rows": [
    {
      "id": "v3-KEY-10-openings",
      "label": "Elevation3 \u00b7 Fixed insulated window projected openings",
      "quantity": 110.69999999999999,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Approximate OUTER frame / opening envelope; includes frame and integral PTAC louver where key8. Not net glass or installed glazing order. First-floor foreground fences/canopies conceal portions. No double addition of these deductions to finish quantities.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "polygons": [
        [
          [
            522.0854582609953,
            300.36326768663196
          ],
          [
            552.0854582609953,
            300.36326768663196
          ],
          [
            552.0854582609953,
            259.36326768663196
          ],
          [
            522.0854582609953,
            259.36326768663196
          ],
          [
            522.0854582609953,
            300.36326768663196
          ]
        ],
        [
          [
            522.0854582609953,
            367.09562626591435
          ],
          [
            552.0854582609953,
            367.09562626591435
          ],
          [
            552.0854582609953,
            326.09562626591435
          ],
          [
            522.0854582609953,
            326.09562626591435
          ],
          [
            522.0854582609953,
            367.09562626591435
          ]
        ],
        [
          [
            522.0854582609953,
            429.51505985966435
          ],
          [
            552.0854582609953,
            429.51505985966435
          ],
          [
            552.0854582609953,
            388.51505985966435
          ],
          [
            522.0854582609953,
            388.51505985966435
          ],
          [
            522.0854582609953,
            429.51505985966435
          ]
        ],
        [
          [
            522.0854582609953,
            494.08781376591435
          ],
          [
            552.0854582609953,
            494.08781376591435
          ],
          [
            552.0854582609953,
            453.08781376591435
          ],
          [
            522.0854582609953,
            453.08781376591435
          ],
          [
            522.0854582609953,
            494.08781376591435
          ]
        ]
      ]
    },
    {
      "id": "v3-KEY-10-frame-perimeter",
      "label": "Elevation3 \u00b7 KEY-10 opening perimeter",
      "quantity": 85.2,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Projected rectangular outer-frame perimeter reference; not sealant quantity at every layer. Confirm actual frame sizes, sill/head returns and concealed edges.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "lines": [
        [
          [
            552.0854582609953,
            259.36326768663196
          ],
          [
            552.0854582609953,
            300.36326768663196
          ],
          [
            522.0854582609953,
            300.36326768663196
          ],
          [
            522.0854582609953,
            259.36326768663196
          ],
          [
            552.0854582609953,
            259.36326768663196
          ]
        ],
        [
          [
            552.0854582609953,
            326.09562626591435
          ],
          [
            552.0854582609953,
            367.09562626591435
          ],
          [
            522.0854582609953,
            367.09562626591435
          ],
          [
            522.0854582609953,
            326.09562626591435
          ],
          [
            552.0854582609953,
            326.09562626591435
          ]
        ],
        [
          [
            552.0854582609953,
            388.51505985966435
          ],
          [
            552.0854582609953,
            429.51505985966435
          ],
          [
            522.0854582609953,
            429.51505985966435
          ],
          [
            522.0854582609953,
            388.51505985966435
          ],
          [
            552.0854582609953,
            388.51505985966435
          ]
        ],
        [
          [
            552.0854582609953,
            453.08781376591435
          ],
          [
            552.0854582609953,
            494.08781376591435
          ],
          [
            522.0854582609953,
            494.08781376591435
          ],
          [
            522.0854582609953,
            453.08781376591435
          ],
          [
            552.0854582609953,
            453.08781376591435
          ]
        ]
      ]
    },
    {
      "id": "v3-KEY-9-openings",
      "label": "Elevation3 \u00b7 Thermally broken insulated storefront projected openings",
      "quantity": 191.56499999999997,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Approximate OUTER frame / opening envelope; includes frame and integral PTAC louver where key8. Not net glass or installed glazing order. First-floor foreground fences/canopies conceal portions. No double addition of these deductions to finish quantities.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "polygons": [
        [
          [
            429.0,
            524.0
          ],
          [
            429.0,
            590.0
          ],
          [
            300.0,
            590.0
          ],
          [
            300.0,
            524.0
          ],
          [
            429.0,
            524.0
          ]
        ]
      ]
    },
    {
      "id": "v3-KEY-9-frame-perimeter",
      "label": "Elevation3 \u00b7 KEY-9 opening perimeter",
      "quantity": 58.5,
      "unit": "LF",
      "color": "#398d79",
      "basis": "Projected rectangular outer-frame perimeter reference; not sealant quantity at every layer. Confirm actual frame sizes, sill/head returns and concealed edges.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "lines": [
        [
          [
            429.0,
            524.0
          ],
          [
            429.0,
            590.0
          ],
          [
            300.0,
            590.0
          ],
          [
            300.0,
            524.0
          ],
          [
            429.0,
            524.0
          ]
        ]
      ]
    },
    {
      "id": "v4-KEY-8-openings",
      "label": "Elevation4 \u00b7 Fixed insulated window with integral PTAC louver projected openings",
      "quantity": 2432.7,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Approximate OUTER frame / opening envelope; includes frame and integral PTAC louver where key8. Not net glass or installed glazing order. First-floor foreground fences/canopies conceal portions. No double addition of these deductions to finish quantities.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "polygons": [
        [
          [
            400.34864637586804,
            832.0247305410879
          ],
          [
            400.34864637586804,
            883.0247305410879
          ],
          [
            440.34864637586804,
            883.0247305410879
          ],
          [
            440.34864637586804,
            832.0247305410879
          ],
          [
            400.34864637586804,
            832.0247305410879
          ]
        ],
        [
          [
            738.4592466001156,
            883.0247305410879
          ],
          [
            778.4592466001156,
            883.0247305410879
          ],
          [
            778.4592466001156,
            832.0247305410879
          ],
          [
            738.4592466001156,
            832.0247305410879
          ],
          [
            738.4592466001156,
            883.0247305410879
          ]
        ],
        [
          [
            653.9315456814236,
            883.0247305410879
          ],
          [
            693.9315456814236,
            883.0247305410879
          ],
          [
            693.9315456814236,
            832.0247305410879
          ],
          [
            653.9315456814236,
            832.0247305410879
          ],
          [
            653.9315456814236,
            883.0247305410879
          ]
        ],
        [
          [
            569.4039125795717,
            832.0247305410879
          ],
          [
            569.4039125795717,
            883.0247305410879
          ],
          [
            609.4039125795717,
            883.0247305410879
          ],
          [
            609.4039125795717,
            832.0247305410879
          ],
          [
            569.4039125795717,
            832.0247305410879
          ]
        ],
        [
          [
            484.8762794777199,
            883.0247305410879
          ],
          [
            524.8762794777199,
            883.0247305410879
          ],
          [
            524.8762794777199,
            832.0247305410879
          ],
          [
            484.8762794777199,
            832.0247305410879
          ],
          [
            484.8762794777199,
            883.0247305410879
          ]
        ],
        [
          [
            484.8762794777199,
            947.5326515480324
          ],
          [
            524.8762794777199,
            947.5326515480324
          ],
          [
            524.8762794777199,
            896.5326515480324
          ],
          [
            484.8762794777199,
            896.5326515480324
          ],
          [
            484.8762794777199,
            947.5326515480324
          ]
        ],
        [
          [
            569.4039125795717,
            896.5326515480324
          ],
          [
            569.4039125795717,
            947.5326515480324
          ],
          [
            609.4039125795717,
            947.5326515480324
          ],
          [
            609.4039125795717,
            896.5326515480324
          ],
          [
            569.4039125795717,
            896.5326515480324
          ]
        ],
        [
          [
            400.34864637586804,
            947.5326515480324
          ],
          [
            440.34864637586804,
            947.5326515480324
          ],
          [
            440.34864637586804,
            896.5326515480324
          ],
          [
            400.34864637586804,
            896.5326515480324
          ],
          [
            400.34864637586804,
            947.5326515480324
          ]
        ],
        [
          [
            653.9315456814236,
            947.5326515480324
          ],
          [
            693.9315456814236,
            947.5326515480324
          ],
          [
            693.9315456814236,
            896.5326515480324
          ],
          [
            653.9315456814236,
            896.5326515480324
          ],
          [
            653.9315456814236,
            947.5326515480324
          ]
        ],
        [
          [
            738.4592466001156,
            947.5326515480324
          ],
          [
            778.4592466001156,
            947.5326515480324
          ],
          [
            778.4592466001156,
            896.5326515480324
          ],
          [
            738.4592466001156,
            896.5326515480324
          ],
          [
            738.4592466001156,
            947.5326515480324
          ]
        ],
        [
          [
            484.8762794777199,
            1012.0405725549767
          ],
          [
            524.8762794777199,
            1012.0405725549767
          ],
          [
            524.8762794777199,
            961.0405725549767
          ],
          [
            484.8762794777199,
            961.0405725549767
          ],
          [
            484.8762794777199,
            1012.0405725549767
          ]
        ],
        [
          [
            569.4039125795717,
            1012.0405725549767
          ],
          [
            609.4039125795717,
            1012.0405725549767
          ],
          [
            609.4039125795717,
            961.0405725549767
          ],
          [
            569.4039125795717,
            961.0405725549767
          ],
          [
            569.4039125795717,
            1012.0405725549767
          ]
        ],
        [
          [
            400.34864637586804,
            1012.0405725549767
          ],
          [
            440.34864637586804,
            1012.0405725549767
          ],
          [
            440.34864637586804,
            961.0405725549767
          ],
          [
            400.34864637586804,
            961.0405725549767
          ],
          [
            400.34864637586804,
            1012.0405725549767
          ]
        ],
        [
          [
            653.9315456814236,
            961.0405725549767
          ],
          [
            653.9315456814236,
            1012.0405725549767
          ],
          [
            693.9315456814236,
            1012.0405725549767
          ],
          [
            693.9315456814236,
            961.0405725549767
          ],
          [
            653.9315456814236,
            961.0405725549767
          ]
        ],
        [
          [
            484.8762794777199,
            1076.5484935619213
          ],
          [
            524.8762794777199,
            1076.5484935619213
          ],
          [
            524.8762794777199,
            1025.5484935619213
          ],
          [
            484.8762794777199,
            1025.5484935619213
          ],
          [
            484.8762794777199,
            1076.5484935619213
          ]
        ],
        [
          [
            569.4039125795717,
            1076.5484935619213
          ],
          [
            609.4039125795717,
            1076.5484935619213
          ],
          [
            609.4039125795717,
            1025.5484935619213
          ],
          [
            569.4039125795717,
            1025.5484935619213
          ],
          [
            569.4039125795717,
            1076.5484935619213
          ]
        ],
        [
          [
            653.9315456814236,
            1025.5484935619213
          ],
          [
            653.9315456814236,
            1076.5484935619213
          ],
          [
            693.9315456814236,
            1076.5484935619213
          ],
          [
            693.9315456814236,
            1025.5484935619213
          ],
          [
            653.9315456814236,
            1025.5484935619213
          ]
        ],
        [
          [
            400.34864637586804,
            1076.5484935619213
          ],
          [
            440.34864637586804,
            1076.5484935619213
          ],
          [
            440.34864637586804,
            1025.5484935619213
          ],
          [
            400.34864637586804,
            1025.5484935619213
          ],
          [
            400.34864637586804,
            1076.5484935619213
          ]
        ],
        [
          [
            991.7119231047452,
            883.0247305410879
          ],
          [
            1031.7119231047452,
            883.0247305410879
          ],
          [
            1031.7119231047452,
            832.0247305410879
          ],
          [
            991.7119231047452,
            832.0247305410879
          ],
          [
            991.7119231047452,
            883.0247305410879
          ]
        ],
        [
          [
            907.5145128038193,
            832.0247305410879
          ],
          [
            907.5145128038193,
            883.0247305410879
          ],
          [
            947.5145128038193,
            883.0247305410879
          ],
          [
            947.5145128038193,
            832.0247305410879
          ],
          [
            907.5145128038193,
            832.0247305410879
          ]
        ],
        [
          [
            822.9868797019676,
            883.0247305410879
          ],
          [
            862.9868797019676,
            883.0247305410879
          ],
          [
            862.9868797019676,
            832.0247305410879
          ],
          [
            822.9868797019676,
            832.0247305410879
          ],
          [
            822.9868797019676,
            883.0247305410879
          ]
        ],
        [
          [
            907.5145128038193,
            947.5326515480324
          ],
          [
            947.5145128038193,
            947.5326515480324
          ],
          [
            947.5145128038193,
            896.5326515480324
          ],
          [
            907.5145128038193,
            896.5326515480324
          ],
          [
            907.5145128038193,
            947.5326515480324
          ]
        ],
        [
          [
            1076.2917299623841,
            947.5326515480324
          ],
          [
            1116.2917299623841,
            947.5326515480324
          ],
          [
            1116.2917299623841,
            896.5326515480324
          ],
          [
            1076.2917299623841,
            896.5326515480324
          ],
          [
            1076.2917299623841,
            947.5326515480324
          ]
        ],
        [
          [
            991.7119231047452,
            947.5326515480324
          ],
          [
            1031.7119231047452,
            947.5326515480324
          ],
          [
            1031.7119231047452,
            896.5326515480324
          ],
          [
            991.7119231047452,
            896.5326515480324
          ],
          [
            991.7119231047452,
            947.5326515480324
          ]
        ],
        [
          [
            822.9868797019676,
            947.5326515480324
          ],
          [
            862.9868797019676,
            947.5326515480324
          ],
          [
            862.9868797019676,
            896.5326515480324
          ],
          [
            822.9868797019676,
            896.5326515480324
          ],
          [
            822.9868797019676,
            947.5326515480324
          ]
        ],
        [
          [
            822.9868797019676,
            1012.0405725549767
          ],
          [
            862.9868797019676,
            1012.0405725549767
          ],
          [
            862.9868797019676,
            961.0405725549767
          ],
          [
            822.9868797019676,
            961.0405725549767
          ],
          [
            822.9868797019676,
            1012.0405725549767
          ]
        ],
        [
          [
            907.5145128038193,
            961.0405725549767
          ],
          [
            907.5145128038193,
            1012.0405725549767
          ],
          [
            947.5145128038193,
            1012.0405725549767
          ],
          [
            947.5145128038193,
            961.0405725549767
          ],
          [
            907.5145128038193,
            961.0405725549767
          ]
        ],
        [
          [
            991.7119231047452,
            1012.0405725549767
          ],
          [
            1031.7119231047452,
            1012.0405725549767
          ],
          [
            1031.7119231047452,
            961.0405725549767
          ],
          [
            991.7119231047452,
            961.0405725549767
          ],
          [
            991.7119231047452,
            1012.0405725549767
          ]
        ],
        [
          [
            1076.2917299623841,
            1012.0405725549767
          ],
          [
            1116.2917299623841,
            1012.0405725549767
          ],
          [
            1116.2917299623841,
            961.0405725549767
          ],
          [
            1076.2917299623841,
            961.0405725549767
          ],
          [
            1076.2917299623841,
            1012.0405725549767
          ]
        ],
        [
          [
            738.4592466001156,
            961.0405725549767
          ],
          [
            738.4592466001156,
            1012.0405725549767
          ],
          [
            778.4592466001156,
            1012.0405725549767
          ],
          [
            778.4592466001156,
            961.0405725549767
          ],
          [
            738.4592466001156,
            961.0405725549767
          ]
        ],
        [
          [
            907.5145128038193,
            1076.5484935619213
          ],
          [
            947.5145128038193,
            1076.5484935619213
          ],
          [
            947.5145128038193,
            1025.5484935619213
          ],
          [
            907.5145128038193,
            1025.5484935619213
          ],
          [
            907.5145128038193,
            1076.5484935619213
          ]
        ],
        [
          [
            738.4592466001156,
            1076.5484935619213
          ],
          [
            778.4592466001156,
            1076.5484935619213
          ],
          [
            778.4592466001156,
            1025.5484935619213
          ],
          [
            738.4592466001156,
            1025.5484935619213
          ],
          [
            738.4592466001156,
            1076.5484935619213
          ]
        ],
        [
          [
            822.9868797019676,
            1025.5484935619213
          ],
          [
            822.9868797019676,
            1076.5484935619213
          ],
          [
            862.9868797019676,
            1076.5484935619213
          ],
          [
            862.9868797019676,
            1025.5484935619213
          ],
          [
            822.9868797019676,
            1025.5484935619213
          ]
        ],
        [
          [
            991.7119231047452,
            1076.5484935619213
          ],
          [
            1031.7119231047452,
            1076.5484935619213
          ],
          [
            1031.7119231047452,
            1025.5484935619213
          ],
          [
            991.7119231047452,
            1025.5484935619213
          ],
          [
            991.7119231047452,
            1076.5484935619213
          ]
        ],
        [
          [
            990.2695945457176,
            1163.0
          ],
          [
            1030.2695945457176,
            1163.0
          ],
          [
            1030.2695945457176,
            1112.0
          ],
          [
            990.2695945457176,
            1112.0
          ],
          [
            990.2695945457176,
            1163.0
          ]
        ],
        [
          [
            1074.8493109809028,
            1163.0
          ],
          [
            1114.8493109809028,
            1163.0
          ],
          [
            1114.8493109809028,
            1112.0
          ],
          [
            1074.8493109809028,
            1112.0
          ],
          [
            1074.8493109809028,
            1163.0
          ]
        ],
        [
          [
            1330.9173810040509,
            883.0247305410879
          ],
          [
            1370.9173810040509,
            883.0247305410879
          ],
          [
            1370.9173810040509,
            832.0247305410879
          ],
          [
            1330.9173810040509,
            832.0247305410879
          ],
          [
            1330.9173810040509,
            883.0247305410879
          ]
        ],
        [
          [
            1161.2190303096063,
            883.0247305410879
          ],
          [
            1201.2190303096063,
            883.0247305410879
          ],
          [
            1201.2190303096063,
            832.0247305410879
          ],
          [
            1161.2190303096063,
            832.0247305410879
          ],
          [
            1161.2190303096063,
            883.0247305410879
          ]
        ],
        [
          [
            1076.2917299623841,
            883.0247305410879
          ],
          [
            1116.2917299623841,
            883.0247305410879
          ],
          [
            1116.2917299623841,
            832.0247305410879
          ],
          [
            1076.2917299623841,
            832.0247305410879
          ],
          [
            1076.2917299623841,
            883.0247305410879
          ]
        ],
        [
          [
            1246.389747902199,
            832.0247305410879
          ],
          [
            1246.389747902199,
            883.0247305410879
          ],
          [
            1286.389747902199,
            883.0247305410879
          ],
          [
            1286.389747902199,
            832.0247305410879
          ],
          [
            1246.389747902199,
            832.0247305410879
          ]
        ],
        [
          [
            1330.9173810040509,
            947.5326515480324
          ],
          [
            1370.9173810040509,
            947.5326515480324
          ],
          [
            1370.9173810040509,
            896.5326515480324
          ],
          [
            1330.9173810040509,
            896.5326515480324
          ],
          [
            1330.9173810040509,
            947.5326515480324
          ]
        ],
        [
          [
            1161.2190303096063,
            947.5326515480324
          ],
          [
            1201.2190303096063,
            947.5326515480324
          ],
          [
            1201.2190303096063,
            896.5326515480324
          ],
          [
            1161.2190303096063,
            896.5326515480324
          ],
          [
            1161.2190303096063,
            947.5326515480324
          ]
        ],
        [
          [
            1246.389747902199,
            947.5326515480324
          ],
          [
            1286.389747902199,
            947.5326515480324
          ],
          [
            1286.389747902199,
            896.5326515480324
          ],
          [
            1246.389747902199,
            896.5326515480324
          ],
          [
            1246.389747902199,
            947.5326515480324
          ]
        ],
        [
          [
            1161.2190303096063,
            1012.0405725549767
          ],
          [
            1201.2190303096063,
            1012.0405725549767
          ],
          [
            1201.2190303096063,
            961.0405725549767
          ],
          [
            1161.2190303096063,
            961.0405725549767
          ],
          [
            1161.2190303096063,
            1012.0405725549767
          ]
        ],
        [
          [
            1330.9173810040509,
            1012.0405725549767
          ],
          [
            1370.9173810040509,
            1012.0405725549767
          ],
          [
            1370.9173810040509,
            961.0405725549767
          ],
          [
            1330.9173810040509,
            961.0405725549767
          ],
          [
            1330.9173810040509,
            1012.0405725549767
          ]
        ],
        [
          [
            1246.389747902199,
            1012.0405725549767
          ],
          [
            1286.389747902199,
            1012.0405725549767
          ],
          [
            1286.389747902199,
            961.0405725549767
          ],
          [
            1246.389747902199,
            961.0405725549767
          ],
          [
            1246.389747902199,
            1012.0405725549767
          ]
        ],
        [
          [
            1246.389747902199,
            1025.5484935619213
          ],
          [
            1246.389747902199,
            1076.5484935619213
          ],
          [
            1286.389747902199,
            1076.5484935619213
          ],
          [
            1286.389747902199,
            1025.5484935619213
          ],
          [
            1246.389747902199,
            1025.5484935619213
          ]
        ],
        [
          [
            1330.9173810040509,
            1076.5484935619213
          ],
          [
            1370.9173810040509,
            1076.5484935619213
          ],
          [
            1370.9173810040509,
            1025.5484935619213
          ],
          [
            1330.9173810040509,
            1025.5484935619213
          ],
          [
            1330.9173810040509,
            1076.5484935619213
          ]
        ],
        [
          [
            1161.2190303096063,
            1076.5484935619213
          ],
          [
            1201.2190303096063,
            1076.5484935619213
          ],
          [
            1201.2190303096063,
            1025.5484935619213
          ],
          [
            1161.2190303096063,
            1025.5484935619213
          ],
          [
            1161.2190303096063,
            1076.5484935619213
          ]
        ],
        [
          [
            1076.2917299623841,
            1076.5484935619213
          ],
          [
            1116.2917299623841,
            1076.5484935619213
          ],
          [
            1116.2917299623841,
            1025.5484935619213
          ],
          [
            1076.2917299623841,
            1025.5484935619213
          ],
          [
            1076.2917299623841,
            1076.5484935619213
          ]
        ],
        [
          [
            1329.4749620225693,
            1163.0
          ],
          [
            1369.4749620225693,
            1163.0
          ],
          [
            1369.4749620225693,
            1112.0
          ],
          [
            1329.4749620225693,
            1112.0
          ],
          [
            1329.4749620225693,
            1163.0
          ]
        ],
        [
          [
            1244.9473289207176,
            1163.0
          ],
          [
            1284.9473289207176,
            1163.0
          ],
          [
            1284.9473289207176,
            1112.0
          ],
          [
            1244.9473289207176,
            1112.0
          ],
          [
            1244.9473289207176,
            1163.0
          ]
        ],
        [
          [
            1159.7767017505785,
            1163.0
          ],
          [
            1199.7767017505785,
            1163.0
          ],
          [
            1199.7767017505785,
            1112.0
          ],
          [
            1159.7767017505785,
            1112.0
          ],
          [
            1159.7767017505785,
            1163.0
          ]
        ]
      ]
    },
    {
      "id": "v4-KEY-8-frame-perimeter",
      "label": "Elevation4 \u00b7 KEY-8 opening perimeter",
      "quantity": 1446.8999999999999,
      "unit": "LF",
      "color": "#b06bad",
      "basis": "Projected rectangular outer-frame perimeter reference; not sealant quantity at every layer. Confirm actual frame sizes, sill/head returns and concealed edges.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "lines": [
        [
          [
            440.34864637586804,
            832.0247305410879
          ],
          [
            440.34864637586804,
            883.0247305410879
          ],
          [
            400.34864637586804,
            883.0247305410879
          ],
          [
            400.34864637586804,
            832.0247305410879
          ],
          [
            440.34864637586804,
            832.0247305410879
          ]
        ],
        [
          [
            524.8762794777199,
            832.0247305410879
          ],
          [
            524.8762794777199,
            883.0247305410879
          ],
          [
            484.8762794777199,
            883.0247305410879
          ],
          [
            484.8762794777199,
            832.0247305410879
          ],
          [
            524.8762794777199,
            832.0247305410879
          ]
        ],
        [
          [
            609.4039125795717,
            832.0247305410879
          ],
          [
            609.4039125795717,
            883.0247305410879
          ],
          [
            569.4039125795717,
            883.0247305410879
          ],
          [
            569.4039125795717,
            832.0247305410879
          ],
          [
            609.4039125795717,
            832.0247305410879
          ]
        ],
        [
          [
            693.9315456814236,
            832.0247305410879
          ],
          [
            693.9315456814236,
            883.0247305410879
          ],
          [
            653.9315456814236,
            883.0247305410879
          ],
          [
            653.9315456814236,
            832.0247305410879
          ],
          [
            693.9315456814236,
            832.0247305410879
          ]
        ],
        [
          [
            778.4592466001156,
            832.0247305410879
          ],
          [
            778.4592466001156,
            883.0247305410879
          ],
          [
            738.4592466001156,
            883.0247305410879
          ],
          [
            738.4592466001156,
            832.0247305410879
          ],
          [
            778.4592466001156,
            832.0247305410879
          ]
        ],
        [
          [
            862.9868797019676,
            832.0247305410879
          ],
          [
            862.9868797019676,
            883.0247305410879
          ],
          [
            822.9868797019676,
            883.0247305410879
          ],
          [
            822.9868797019676,
            832.0247305410879
          ],
          [
            862.9868797019676,
            832.0247305410879
          ]
        ],
        [
          [
            947.5145128038193,
            832.0247305410879
          ],
          [
            947.5145128038193,
            883.0247305410879
          ],
          [
            907.5145128038193,
            883.0247305410879
          ],
          [
            907.5145128038193,
            832.0247305410879
          ],
          [
            947.5145128038193,
            832.0247305410879
          ]
        ],
        [
          [
            1031.7119231047452,
            832.0247305410879
          ],
          [
            1031.7119231047452,
            883.0247305410879
          ],
          [
            991.7119231047452,
            883.0247305410879
          ],
          [
            991.7119231047452,
            832.0247305410879
          ],
          [
            1031.7119231047452,
            832.0247305410879
          ]
        ],
        [
          [
            1116.2917299623841,
            832.0247305410879
          ],
          [
            1116.2917299623841,
            883.0247305410879
          ],
          [
            1076.2917299623841,
            883.0247305410879
          ],
          [
            1076.2917299623841,
            832.0247305410879
          ],
          [
            1116.2917299623841,
            832.0247305410879
          ]
        ],
        [
          [
            1201.2190303096063,
            832.0247305410879
          ],
          [
            1201.2190303096063,
            883.0247305410879
          ],
          [
            1161.2190303096063,
            883.0247305410879
          ],
          [
            1161.2190303096063,
            832.0247305410879
          ],
          [
            1201.2190303096063,
            832.0247305410879
          ]
        ],
        [
          [
            1286.389747902199,
            832.0247305410879
          ],
          [
            1286.389747902199,
            883.0247305410879
          ],
          [
            1246.389747902199,
            883.0247305410879
          ],
          [
            1246.389747902199,
            832.0247305410879
          ],
          [
            1286.389747902199,
            832.0247305410879
          ]
        ],
        [
          [
            1370.9173810040509,
            832.0247305410879
          ],
          [
            1370.9173810040509,
            883.0247305410879
          ],
          [
            1330.9173810040509,
            883.0247305410879
          ],
          [
            1330.9173810040509,
            832.0247305410879
          ],
          [
            1370.9173810040509,
            832.0247305410879
          ]
        ],
        [
          [
            440.34864637586804,
            896.5326515480324
          ],
          [
            440.34864637586804,
            947.5326515480324
          ],
          [
            400.34864637586804,
            947.5326515480324
          ],
          [
            400.34864637586804,
            896.5326515480324
          ],
          [
            440.34864637586804,
            896.5326515480324
          ]
        ],
        [
          [
            524.8762794777199,
            896.5326515480324
          ],
          [
            524.8762794777199,
            947.5326515480324
          ],
          [
            484.8762794777199,
            947.5326515480324
          ],
          [
            484.8762794777199,
            896.5326515480324
          ],
          [
            524.8762794777199,
            896.5326515480324
          ]
        ],
        [
          [
            609.4039125795717,
            896.5326515480324
          ],
          [
            609.4039125795717,
            947.5326515480324
          ],
          [
            569.4039125795717,
            947.5326515480324
          ],
          [
            569.4039125795717,
            896.5326515480324
          ],
          [
            609.4039125795717,
            896.5326515480324
          ]
        ],
        [
          [
            693.9315456814236,
            896.5326515480324
          ],
          [
            693.9315456814236,
            947.5326515480324
          ],
          [
            653.9315456814236,
            947.5326515480324
          ],
          [
            653.9315456814236,
            896.5326515480324
          ],
          [
            693.9315456814236,
            896.5326515480324
          ]
        ],
        [
          [
            778.4592466001156,
            896.5326515480324
          ],
          [
            778.4592466001156,
            947.5326515480324
          ],
          [
            738.4592466001156,
            947.5326515480324
          ],
          [
            738.4592466001156,
            896.5326515480324
          ],
          [
            778.4592466001156,
            896.5326515480324
          ]
        ],
        [
          [
            862.9868797019676,
            896.5326515480324
          ],
          [
            862.9868797019676,
            947.5326515480324
          ],
          [
            822.9868797019676,
            947.5326515480324
          ],
          [
            822.9868797019676,
            896.5326515480324
          ],
          [
            862.9868797019676,
            896.5326515480324
          ]
        ],
        [
          [
            947.5145128038193,
            896.5326515480324
          ],
          [
            947.5145128038193,
            947.5326515480324
          ],
          [
            907.5145128038193,
            947.5326515480324
          ],
          [
            907.5145128038193,
            896.5326515480324
          ],
          [
            947.5145128038193,
            896.5326515480324
          ]
        ],
        [
          [
            1031.7119231047452,
            896.5326515480324
          ],
          [
            1031.7119231047452,
            947.5326515480324
          ],
          [
            991.7119231047452,
            947.5326515480324
          ],
          [
            991.7119231047452,
            896.5326515480324
          ],
          [
            1031.7119231047452,
            896.5326515480324
          ]
        ],
        [
          [
            1116.2917299623841,
            896.5326515480324
          ],
          [
            1116.2917299623841,
            947.5326515480324
          ],
          [
            1076.2917299623841,
            947.5326515480324
          ],
          [
            1076.2917299623841,
            896.5326515480324
          ],
          [
            1116.2917299623841,
            896.5326515480324
          ]
        ],
        [
          [
            1201.2190303096063,
            896.5326515480324
          ],
          [
            1201.2190303096063,
            947.5326515480324
          ],
          [
            1161.2190303096063,
            947.5326515480324
          ],
          [
            1161.2190303096063,
            896.5326515480324
          ],
          [
            1201.2190303096063,
            896.5326515480324
          ]
        ],
        [
          [
            1286.389747902199,
            896.5326515480324
          ],
          [
            1286.389747902199,
            947.5326515480324
          ],
          [
            1246.389747902199,
            947.5326515480324
          ],
          [
            1246.389747902199,
            896.5326515480324
          ],
          [
            1286.389747902199,
            896.5326515480324
          ]
        ],
        [
          [
            1370.9173810040509,
            896.5326515480324
          ],
          [
            1370.9173810040509,
            947.5326515480324
          ],
          [
            1330.9173810040509,
            947.5326515480324
          ],
          [
            1330.9173810040509,
            896.5326515480324
          ],
          [
            1370.9173810040509,
            896.5326515480324
          ]
        ],
        [
          [
            440.34864637586804,
            961.0405725549767
          ],
          [
            440.34864637586804,
            1012.0405725549767
          ],
          [
            400.34864637586804,
            1012.0405725549767
          ],
          [
            400.34864637586804,
            961.0405725549767
          ],
          [
            440.34864637586804,
            961.0405725549767
          ]
        ],
        [
          [
            524.8762794777199,
            961.0405725549767
          ],
          [
            524.8762794777199,
            1012.0405725549767
          ],
          [
            484.8762794777199,
            1012.0405725549767
          ],
          [
            484.8762794777199,
            961.0405725549767
          ],
          [
            524.8762794777199,
            961.0405725549767
          ]
        ],
        [
          [
            609.4039125795717,
            961.0405725549767
          ],
          [
            609.4039125795717,
            1012.0405725549767
          ],
          [
            569.4039125795717,
            1012.0405725549767
          ],
          [
            569.4039125795717,
            961.0405725549767
          ],
          [
            609.4039125795717,
            961.0405725549767
          ]
        ],
        [
          [
            693.9315456814236,
            961.0405725549767
          ],
          [
            693.9315456814236,
            1012.0405725549767
          ],
          [
            653.9315456814236,
            1012.0405725549767
          ],
          [
            653.9315456814236,
            961.0405725549767
          ],
          [
            693.9315456814236,
            961.0405725549767
          ]
        ],
        [
          [
            778.4592466001156,
            961.0405725549767
          ],
          [
            778.4592466001156,
            1012.0405725549767
          ],
          [
            738.4592466001156,
            1012.0405725549767
          ],
          [
            738.4592466001156,
            961.0405725549767
          ],
          [
            778.4592466001156,
            961.0405725549767
          ]
        ],
        [
          [
            862.9868797019676,
            961.0405725549767
          ],
          [
            862.9868797019676,
            1012.0405725549767
          ],
          [
            822.9868797019676,
            1012.0405725549767
          ],
          [
            822.9868797019676,
            961.0405725549767
          ],
          [
            862.9868797019676,
            961.0405725549767
          ]
        ],
        [
          [
            947.5145128038193,
            961.0405725549767
          ],
          [
            947.5145128038193,
            1012.0405725549767
          ],
          [
            907.5145128038193,
            1012.0405725549767
          ],
          [
            907.5145128038193,
            961.0405725549767
          ],
          [
            947.5145128038193,
            961.0405725549767
          ]
        ],
        [
          [
            1031.7119231047452,
            961.0405725549767
          ],
          [
            1031.7119231047452,
            1012.0405725549767
          ],
          [
            991.7119231047452,
            1012.0405725549767
          ],
          [
            991.7119231047452,
            961.0405725549767
          ],
          [
            1031.7119231047452,
            961.0405725549767
          ]
        ],
        [
          [
            1116.2917299623841,
            961.0405725549767
          ],
          [
            1116.2917299623841,
            1012.0405725549767
          ],
          [
            1076.2917299623841,
            1012.0405725549767
          ],
          [
            1076.2917299623841,
            961.0405725549767
          ],
          [
            1116.2917299623841,
            961.0405725549767
          ]
        ],
        [
          [
            1201.2190303096063,
            961.0405725549767
          ],
          [
            1201.2190303096063,
            1012.0405725549767
          ],
          [
            1161.2190303096063,
            1012.0405725549767
          ],
          [
            1161.2190303096063,
            961.0405725549767
          ],
          [
            1201.2190303096063,
            961.0405725549767
          ]
        ],
        [
          [
            1286.389747902199,
            961.0405725549767
          ],
          [
            1286.389747902199,
            1012.0405725549767
          ],
          [
            1246.389747902199,
            1012.0405725549767
          ],
          [
            1246.389747902199,
            961.0405725549767
          ],
          [
            1286.389747902199,
            961.0405725549767
          ]
        ],
        [
          [
            1370.9173810040509,
            961.0405725549767
          ],
          [
            1370.9173810040509,
            1012.0405725549767
          ],
          [
            1330.9173810040509,
            1012.0405725549767
          ],
          [
            1330.9173810040509,
            961.0405725549767
          ],
          [
            1370.9173810040509,
            961.0405725549767
          ]
        ],
        [
          [
            440.34864637586804,
            1025.5484935619213
          ],
          [
            440.34864637586804,
            1076.5484935619213
          ],
          [
            400.34864637586804,
            1076.5484935619213
          ],
          [
            400.34864637586804,
            1025.5484935619213
          ],
          [
            440.34864637586804,
            1025.5484935619213
          ]
        ],
        [
          [
            524.8762794777199,
            1025.5484935619213
          ],
          [
            524.8762794777199,
            1076.5484935619213
          ],
          [
            484.8762794777199,
            1076.5484935619213
          ],
          [
            484.8762794777199,
            1025.5484935619213
          ],
          [
            524.8762794777199,
            1025.5484935619213
          ]
        ],
        [
          [
            609.4039125795717,
            1025.5484935619213
          ],
          [
            609.4039125795717,
            1076.5484935619213
          ],
          [
            569.4039125795717,
            1076.5484935619213
          ],
          [
            569.4039125795717,
            1025.5484935619213
          ],
          [
            609.4039125795717,
            1025.5484935619213
          ]
        ],
        [
          [
            693.9315456814236,
            1025.5484935619213
          ],
          [
            693.9315456814236,
            1076.5484935619213
          ],
          [
            653.9315456814236,
            1076.5484935619213
          ],
          [
            653.9315456814236,
            1025.5484935619213
          ],
          [
            693.9315456814236,
            1025.5484935619213
          ]
        ],
        [
          [
            778.4592466001156,
            1025.5484935619213
          ],
          [
            778.4592466001156,
            1076.5484935619213
          ],
          [
            738.4592466001156,
            1076.5484935619213
          ],
          [
            738.4592466001156,
            1025.5484935619213
          ],
          [
            778.4592466001156,
            1025.5484935619213
          ]
        ],
        [
          [
            862.9868797019676,
            1025.5484935619213
          ],
          [
            862.9868797019676,
            1076.5484935619213
          ],
          [
            822.9868797019676,
            1076.5484935619213
          ],
          [
            822.9868797019676,
            1025.5484935619213
          ],
          [
            862.9868797019676,
            1025.5484935619213
          ]
        ],
        [
          [
            947.5145128038193,
            1025.5484935619213
          ],
          [
            947.5145128038193,
            1076.5484935619213
          ],
          [
            907.5145128038193,
            1076.5484935619213
          ],
          [
            907.5145128038193,
            1025.5484935619213
          ],
          [
            947.5145128038193,
            1025.5484935619213
          ]
        ],
        [
          [
            1031.7119231047452,
            1025.5484935619213
          ],
          [
            1031.7119231047452,
            1076.5484935619213
          ],
          [
            991.7119231047452,
            1076.5484935619213
          ],
          [
            991.7119231047452,
            1025.5484935619213
          ],
          [
            1031.7119231047452,
            1025.5484935619213
          ]
        ],
        [
          [
            1116.2917299623841,
            1025.5484935619213
          ],
          [
            1116.2917299623841,
            1076.5484935619213
          ],
          [
            1076.2917299623841,
            1076.5484935619213
          ],
          [
            1076.2917299623841,
            1025.5484935619213
          ],
          [
            1116.2917299623841,
            1025.5484935619213
          ]
        ],
        [
          [
            1201.2190303096063,
            1025.5484935619213
          ],
          [
            1201.2190303096063,
            1076.5484935619213
          ],
          [
            1161.2190303096063,
            1076.5484935619213
          ],
          [
            1161.2190303096063,
            1025.5484935619213
          ],
          [
            1201.2190303096063,
            1025.5484935619213
          ]
        ],
        [
          [
            1286.389747902199,
            1025.5484935619213
          ],
          [
            1286.389747902199,
            1076.5484935619213
          ],
          [
            1246.389747902199,
            1076.5484935619213
          ],
          [
            1246.389747902199,
            1025.5484935619213
          ],
          [
            1286.389747902199,
            1025.5484935619213
          ]
        ],
        [
          [
            1370.9173810040509,
            1025.5484935619213
          ],
          [
            1370.9173810040509,
            1076.5484935619213
          ],
          [
            1330.9173810040509,
            1076.5484935619213
          ],
          [
            1330.9173810040509,
            1025.5484935619213
          ],
          [
            1370.9173810040509,
            1025.5484935619213
          ]
        ],
        [
          [
            1030.2695945457176,
            1112.0
          ],
          [
            1030.2695945457176,
            1163.0
          ],
          [
            990.2695945457176,
            1163.0
          ],
          [
            990.2695945457176,
            1112.0
          ],
          [
            1030.2695945457176,
            1112.0
          ]
        ],
        [
          [
            1114.8493109809028,
            1112.0
          ],
          [
            1114.8493109809028,
            1163.0
          ],
          [
            1074.8493109809028,
            1163.0
          ],
          [
            1074.8493109809028,
            1112.0
          ],
          [
            1114.8493109809028,
            1112.0
          ]
        ],
        [
          [
            1199.7767017505785,
            1112.0
          ],
          [
            1199.7767017505785,
            1163.0
          ],
          [
            1159.7767017505785,
            1163.0
          ],
          [
            1159.7767017505785,
            1112.0
          ],
          [
            1199.7767017505785,
            1112.0
          ]
        ],
        [
          [
            1284.9473289207176,
            1112.0
          ],
          [
            1284.9473289207176,
            1163.0
          ],
          [
            1244.9473289207176,
            1163.0
          ],
          [
            1244.9473289207176,
            1112.0
          ],
          [
            1284.9473289207176,
            1112.0
          ]
        ],
        [
          [
            1369.4749620225693,
            1112.0
          ],
          [
            1369.4749620225693,
            1163.0
          ],
          [
            1329.4749620225693,
            1163.0
          ],
          [
            1329.4749620225693,
            1112.0
          ],
          [
            1369.4749620225693,
            1112.0
          ]
        ]
      ]
    },
    {
      "id": "v4-KEY-10-openings",
      "label": "Elevation4 \u00b7 Fixed insulated window projected openings",
      "quantity": 44.099999999999994,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Approximate OUTER frame / opening envelope; includes frame and integral PTAC louver where key8. Not net glass or installed glazing order. First-floor foreground fences/canopies conceal portions. No double addition of these deductions to finish quantities.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "polygons": [
        [
          [
            778.9530210141781,
            1107.9639304832176
          ],
          [
            778.9530210141781,
            1156.9639304832176
          ],
          [
            738.9530210141781,
            1156.9639304832176
          ],
          [
            738.9530210141781,
            1107.9639304832176
          ],
          [
            778.9530210141781,
            1107.9639304832176
          ]
        ]
      ]
    },
    {
      "id": "v4-KEY-10-frame-perimeter",
      "label": "Elevation4 \u00b7 KEY-10 opening perimeter",
      "quantity": 26.7,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Projected rectangular outer-frame perimeter reference; not sealant quantity at every layer. Confirm actual frame sizes, sill/head returns and concealed edges.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "lines": [
        [
          [
            778.9530210141781,
            1107.9639304832176
          ],
          [
            778.9530210141781,
            1156.9639304832176
          ],
          [
            738.9530210141781,
            1156.9639304832176
          ],
          [
            738.9530210141781,
            1107.9639304832176
          ],
          [
            778.9530210141781,
            1107.9639304832176
          ]
        ]
      ]
    },
    {
      "id": "v3-ex5-gross",
      "label": "Elevation3 \u00b7 EX-5 ACCENT BAND gross projected face",
      "quantity": 440.99999999999994,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Design-class face before openings. Approximate traced hatch boundaries; no material selection inferred. Excludes fields assigned to preceding classes. Gross and net rows are alternatives, never additive. Projecting returns, joints and concealed faces not included.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "polygons": [
        [
          [
            299.0,
            248.0
          ],
          [
            299.0,
            262.0
          ],
          [
            649.0,
            262.0
          ],
          [
            649.0,
            248.0
          ],
          [
            299.0,
            248.0
          ]
        ],
        [
          [
            299.0,
            312.0
          ],
          [
            299.0,
            326.0
          ],
          [
            649.0,
            326.0
          ],
          [
            649.0,
            312.0
          ],
          [
            299.0,
            312.0
          ]
        ],
        [
          [
            299.0,
            377.0
          ],
          [
            299.0,
            391.0
          ],
          [
            649.0,
            391.0
          ],
          [
            649.0,
            377.0
          ],
          [
            299.0,
            377.0
          ]
        ],
        [
          [
            299.0,
            442.0
          ],
          [
            299.0,
            456.0
          ],
          [
            649.0,
            456.0
          ],
          [
            649.0,
            442.0
          ],
          [
            299.0,
            442.0
          ]
        ]
      ]
    },
    {
      "id": "v3-ex5-net",
      "label": "Elevation3 \u00b7 EX-5 ACCENT BAND face less traced openings",
      "quantity": 435.57714538574214,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Same gross face LESS currently traced window/storefront envelopes. PROVISIONAL NET: unkeyed doors, foreground concealment, exact frame sizes and local trim still require reconciliation. Not net installed finish order; no waste/returns.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "polygons": [
        [
          [
            299.0,
            262.0
          ],
          [
            522.0854582609953,
            262.0
          ],
          [
            522.0854582609953,
            259.36326768663196
          ],
          [
            552.0854582609953,
            259.36326768663196
          ],
          [
            552.0854582609953,
            262.0
          ],
          [
            649.0,
            262.0
          ],
          [
            649.0,
            248.0
          ],
          [
            299.0,
            248.0
          ],
          [
            299.0,
            262.0
          ]
        ],
        [
          [
            299.0,
            326.0
          ],
          [
            649.0,
            326.0
          ],
          [
            649.0,
            312.0
          ],
          [
            299.0,
            312.0
          ],
          [
            299.0,
            326.0
          ]
        ],
        [
          [
            299.0,
            391.0
          ],
          [
            522.0854582609953,
            391.0
          ],
          [
            522.0854582609953,
            388.51505985966435
          ],
          [
            552.0854582609953,
            388.51505985966435
          ],
          [
            552.0854582609953,
            391.0
          ],
          [
            649.0,
            391.0
          ],
          [
            649.0,
            377.0
          ],
          [
            299.0,
            377.0
          ],
          [
            299.0,
            391.0
          ]
        ],
        [
          [
            299.0,
            456.0
          ],
          [
            522.0854582609953,
            456.0
          ],
          [
            522.0854582609953,
            453.08781376591435
          ],
          [
            552.0854582609953,
            453.08781376591435
          ],
          [
            552.0854582609953,
            456.0
          ],
          [
            649.0,
            456.0
          ],
          [
            649.0,
            442.0
          ],
          [
            299.0,
            442.0
          ],
          [
            299.0,
            456.0
          ]
        ]
      ]
    },
    {
      "id": "v3-band-runs",
      "label": "Elevation3 \u00b7 accent-band horizontal runs",
      "quantity": 210.0,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Projected horizontal runs by distinct band field. Min2-inch proud relief per legend; end returns, backing and actual section depth unresolved.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "lines": [
        [
          [
            299.0,
            255.0
          ],
          [
            649.0,
            255.0
          ]
        ],
        [
          [
            299.0,
            319.0
          ],
          [
            649.0,
            319.0
          ]
        ],
        [
          [
            299.0,
            384.0
          ],
          [
            649.0,
            384.0
          ]
        ],
        [
          [
            299.0,
            449.0
          ],
          [
            649.0,
            449.0
          ]
        ]
      ]
    },
    {
      "id": "v3-ex8-gross",
      "label": "Elevation3 \u00b7 EX-8 BEACON reveal / beam gross projected face",
      "quantity": 113.39999999999999,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Design-class face before openings. Approximate traced hatch boundaries; no material selection inferred. Excludes fields assigned to preceding classes. Gross and net rows are alternatives, never additive. Projecting returns, joints and concealed faces not included.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "polygons": [
        [
          [
            285.0,
            183.0
          ],
          [
            285.0,
            228.0
          ],
          [
            397.0,
            228.0
          ],
          [
            397.0,
            183.0
          ],
          [
            285.0,
            183.0
          ]
        ]
      ]
    },
    {
      "id": "v3-ex8-net",
      "label": "Elevation3 \u00b7 EX-8 BEACON reveal / beam face less traced openings",
      "quantity": 113.39999999999999,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Same gross face LESS currently traced window/storefront envelopes. PROVISIONAL NET: unkeyed doors, foreground concealment, exact frame sizes and local trim still require reconciliation. Not net installed finish order; no waste/returns.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "polygons": [
        [
          [
            285.0,
            228.0
          ],
          [
            397.0,
            228.0
          ],
          [
            397.0,
            183.0
          ],
          [
            285.0,
            183.0
          ],
          [
            285.0,
            228.0
          ]
        ]
      ]
    },
    {
      "id": "v3-ex6-gross",
      "label": "Elevation3 \u00b7 EX-6 SUPPORT base gross projected face",
      "quantity": 630.3599999999999,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Design-class face before openings. Approximate traced hatch boundaries; no material selection inferred. Excludes fields assigned to preceding classes. Gross and net rows are alternatives, never additive. Projecting returns, joints and concealed faces not included.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "polygons": [
        [
          [
            299.0,
            523.0
          ],
          [
            299.0,
            591.0
          ],
          [
            711.0,
            591.0
          ],
          [
            711.0,
            523.0
          ],
          [
            299.0,
            523.0
          ]
        ]
      ]
    },
    {
      "id": "v3-ex6-net",
      "label": "Elevation3 \u00b7 EX-6 SUPPORT base face less traced openings",
      "quantity": 438.79499999999996,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Same gross face LESS currently traced window/storefront envelopes. PROVISIONAL NET: unkeyed doors, foreground concealment, exact frame sizes and local trim still require reconciliation. Not net installed finish order; no waste/returns.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "polygons": [
        [
          [
            299.0,
            591.0
          ],
          [
            711.0,
            591.0
          ],
          [
            711.0,
            523.0
          ],
          [
            299.0,
            523.0
          ],
          [
            299.0,
            591.0
          ]
        ],
        [
          [
            300.0,
            590.0
          ],
          [
            300.0,
            524.0
          ],
          [
            429.0,
            524.0
          ],
          [
            429.0,
            590.0
          ],
          [
            300.0,
            590.0
          ]
        ]
      ]
    },
    {
      "id": "v3-ex2-gross",
      "label": "Elevation3 \u00b7 EX-2 WRAP projecting frame gross projected face",
      "quantity": 1302.7274999999997,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Design-class face before openings. Approximate traced hatch boundaries; no material selection inferred. Excludes fields assigned to preceding classes. Gross and net rows are alternatives, never additive. Projecting returns, joints and concealed faces not included.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "polygons": [
        [
          [
            397.0,
            228.0
          ],
          [
            285.0,
            228.0
          ],
          [
            271.0,
            228.0
          ],
          [
            271.0,
            248.0
          ],
          [
            271.0,
            591.0
          ],
          [
            299.0,
            591.0
          ],
          [
            299.0,
            523.0
          ],
          [
            649.0,
            523.0
          ],
          [
            711.0,
            523.0
          ],
          [
            711.0,
            591.0
          ],
          [
            756.0,
            591.0
          ],
          [
            756.0,
            248.0
          ],
          [
            764.0,
            248.0
          ],
          [
            764.0,
            228.0
          ],
          [
            397.0,
            228.0
          ]
        ],
        [
          [
            649.0,
            248.0
          ],
          [
            649.0,
            262.0
          ],
          [
            649.0,
            312.0
          ],
          [
            649.0,
            326.0
          ],
          [
            649.0,
            377.0
          ],
          [
            649.0,
            391.0
          ],
          [
            649.0,
            442.0
          ],
          [
            649.0,
            456.0
          ],
          [
            649.0,
            506.0
          ],
          [
            299.0,
            506.0
          ],
          [
            299.0,
            456.0
          ],
          [
            299.0,
            442.0
          ],
          [
            299.0,
            391.0
          ],
          [
            299.0,
            377.0
          ],
          [
            299.0,
            326.0
          ],
          [
            299.0,
            312.0
          ],
          [
            299.0,
            262.0
          ],
          [
            299.0,
            248.0
          ],
          [
            649.0,
            248.0
          ]
        ]
      ]
    },
    {
      "id": "v3-ex2-net",
      "label": "Elevation3 \u00b7 EX-2 WRAP projecting frame face less traced openings",
      "quantity": 1302.7274999999997,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Same gross face LESS currently traced window/storefront envelopes. PROVISIONAL NET: unkeyed doors, foreground concealment, exact frame sizes and local trim still require reconciliation. Not net installed finish order; no waste/returns.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "polygons": [
        [
          [
            285.0,
            228.0
          ],
          [
            271.0,
            228.0
          ],
          [
            271.0,
            248.0
          ],
          [
            271.0,
            591.0
          ],
          [
            299.0,
            591.0
          ],
          [
            299.0,
            523.0
          ],
          [
            649.0,
            523.0
          ],
          [
            711.0,
            523.0
          ],
          [
            711.0,
            591.0
          ],
          [
            756.0,
            591.0
          ],
          [
            756.0,
            248.0
          ],
          [
            764.0,
            248.0
          ],
          [
            764.0,
            228.0
          ],
          [
            397.0,
            228.0
          ],
          [
            285.0,
            228.0
          ]
        ],
        [
          [
            649.0,
            262.0
          ],
          [
            649.0,
            312.0
          ],
          [
            649.0,
            326.0
          ],
          [
            649.0,
            377.0
          ],
          [
            649.0,
            391.0
          ],
          [
            649.0,
            442.0
          ],
          [
            649.0,
            456.0
          ],
          [
            649.0,
            506.0
          ],
          [
            299.0,
            506.0
          ],
          [
            299.0,
            456.0
          ],
          [
            299.0,
            442.0
          ],
          [
            299.0,
            391.0
          ],
          [
            299.0,
            377.0
          ],
          [
            299.0,
            326.0
          ],
          [
            299.0,
            312.0
          ],
          [
            299.0,
            262.0
          ],
          [
            299.0,
            248.0
          ],
          [
            649.0,
            248.0
          ],
          [
            649.0,
            262.0
          ]
        ]
      ]
    },
    {
      "id": "v3-ex3-gross",
      "label": "Elevation3 \u00b7 EX-3 LINK transition gross projected face",
      "quantity": 431.7749999999999,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Design-class face before openings. Approximate traced hatch boundaries; no material selection inferred. Excludes fields assigned to preceding classes. Gross and net rows are alternatives, never additive. Projecting returns, joints and concealed faces not included.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "polygons": [
        [
          [
            554.0,
            312.0
          ],
          [
            649.0,
            312.0
          ],
          [
            649.0,
            262.0
          ],
          [
            554.0,
            262.0
          ],
          [
            554.0,
            312.0
          ]
        ],
        [
          [
            554.0,
            377.0
          ],
          [
            649.0,
            377.0
          ],
          [
            649.0,
            326.0
          ],
          [
            554.0,
            326.0
          ],
          [
            554.0,
            377.0
          ]
        ],
        [
          [
            554.0,
            442.0
          ],
          [
            649.0,
            442.0
          ],
          [
            649.0,
            391.0
          ],
          [
            554.0,
            391.0
          ],
          [
            554.0,
            442.0
          ]
        ],
        [
          [
            554.0,
            506.0
          ],
          [
            649.0,
            506.0
          ],
          [
            649.0,
            456.0
          ],
          [
            554.0,
            456.0
          ],
          [
            554.0,
            506.0
          ]
        ]
      ]
    },
    {
      "id": "v3-ex3-net",
      "label": "Elevation3 \u00b7 EX-3 LINK transition face less traced openings",
      "quantity": 431.7749999999999,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Same gross face LESS currently traced window/storefront envelopes. PROVISIONAL NET: unkeyed doors, foreground concealment, exact frame sizes and local trim still require reconciliation. Not net installed finish order; no waste/returns.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "polygons": [
        [
          [
            649.0,
            312.0
          ],
          [
            649.0,
            262.0
          ],
          [
            554.0,
            262.0
          ],
          [
            554.0,
            312.0
          ],
          [
            649.0,
            312.0
          ]
        ],
        [
          [
            649.0,
            377.0
          ],
          [
            649.0,
            326.0
          ],
          [
            554.0,
            326.0
          ],
          [
            554.0,
            377.0
          ],
          [
            649.0,
            377.0
          ]
        ],
        [
          [
            649.0,
            442.0
          ],
          [
            649.0,
            391.0
          ],
          [
            554.0,
            391.0
          ],
          [
            554.0,
            442.0
          ],
          [
            649.0,
            442.0
          ]
        ],
        [
          [
            649.0,
            506.0
          ],
          [
            649.0,
            456.0
          ],
          [
            554.0,
            456.0
          ],
          [
            554.0,
            506.0
          ],
          [
            649.0,
            506.0
          ]
        ]
      ]
    },
    {
      "id": "v3-ex1-gross",
      "label": "Elevation3 \u00b7 EX-1 CORE body gross projected face",
      "quantity": 1158.975,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Design-class face before openings. Approximate traced hatch boundaries; no material selection inferred. Excludes fields assigned to preceding classes. Gross and net rows are alternatives, never additive. Projecting returns, joints and concealed faces not included.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "polygons": [
        [
          [
            299.0,
            312.0
          ],
          [
            554.0,
            312.0
          ],
          [
            554.0,
            262.0
          ],
          [
            299.0,
            262.0
          ],
          [
            299.0,
            312.0
          ]
        ],
        [
          [
            299.0,
            377.0
          ],
          [
            554.0,
            377.0
          ],
          [
            554.0,
            326.0
          ],
          [
            299.0,
            326.0
          ],
          [
            299.0,
            377.0
          ]
        ],
        [
          [
            299.0,
            442.0
          ],
          [
            554.0,
            442.0
          ],
          [
            554.0,
            391.0
          ],
          [
            299.0,
            391.0
          ],
          [
            299.0,
            442.0
          ]
        ],
        [
          [
            299.0,
            506.0
          ],
          [
            554.0,
            506.0
          ],
          [
            554.0,
            456.0
          ],
          [
            299.0,
            456.0
          ],
          [
            299.0,
            506.0
          ]
        ]
      ]
    },
    {
      "id": "v3-ex1-net",
      "label": "Elevation3 \u00b7 EX-1 CORE body face less traced openings",
      "quantity": 1053.6978546142577,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Same gross face LESS currently traced window/storefront envelopes. PROVISIONAL NET: unkeyed doors, foreground concealment, exact frame sizes and local trim still require reconciliation. Not net installed finish order; no waste/returns.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "polygons": [
        [
          [
            554.0,
            312.0
          ],
          [
            554.0,
            262.0
          ],
          [
            552.0854582609953,
            262.0
          ],
          [
            552.0854582609953,
            300.36326768663196
          ],
          [
            522.0854582609953,
            300.36326768663196
          ],
          [
            522.0854582609953,
            262.0
          ],
          [
            299.0,
            262.0
          ],
          [
            299.0,
            312.0
          ],
          [
            554.0,
            312.0
          ]
        ],
        [
          [
            554.0,
            377.0
          ],
          [
            554.0,
            326.0
          ],
          [
            299.0,
            326.0
          ],
          [
            299.0,
            377.0
          ],
          [
            554.0,
            377.0
          ]
        ],
        [
          [
            522.0854582609953,
            326.09562626591435
          ],
          [
            552.0854582609953,
            326.09562626591435
          ],
          [
            552.0854582609953,
            367.09562626591435
          ],
          [
            522.0854582609953,
            367.09562626591435
          ],
          [
            522.0854582609953,
            326.09562626591435
          ]
        ],
        [
          [
            554.0,
            442.0
          ],
          [
            554.0,
            391.0
          ],
          [
            552.0854582609953,
            391.0
          ],
          [
            552.0854582609953,
            429.51505985966435
          ],
          [
            522.0854582609953,
            429.51505985966435
          ],
          [
            522.0854582609953,
            391.0
          ],
          [
            299.0,
            391.0
          ],
          [
            299.0,
            442.0
          ],
          [
            554.0,
            442.0
          ]
        ],
        [
          [
            554.0,
            506.0
          ],
          [
            554.0,
            456.0
          ],
          [
            552.0854582609953,
            456.0
          ],
          [
            552.0854582609953,
            494.08781376591435
          ],
          [
            522.0854582609953,
            494.08781376591435
          ],
          [
            522.0854582609953,
            456.0
          ],
          [
            299.0,
            456.0
          ],
          [
            299.0,
            506.0
          ],
          [
            554.0,
            506.0
          ]
        ]
      ]
    },
    {
      "id": "v3-classified-envelope",
      "label": "Elevation3 \u00b7 combined classified face reference",
      "quantity": 4078.2374999999993,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Combined reference envelope of traced finish classes. Includes openings before deduction; do not add to class rows. Foreground fences, gates and appendages may overlap the building behind them and require separate reconciliation.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "polygons": [
        [
          [
            271.0,
            248.0
          ],
          [
            271.0,
            591.0
          ],
          [
            299.0,
            591.0
          ],
          [
            711.0,
            591.0
          ],
          [
            756.0,
            591.0
          ],
          [
            756.0,
            248.0
          ],
          [
            764.0,
            248.0
          ],
          [
            764.0,
            228.0
          ],
          [
            397.0,
            228.0
          ],
          [
            397.0,
            183.0
          ],
          [
            285.0,
            183.0
          ],
          [
            285.0,
            228.0
          ],
          [
            271.0,
            228.0
          ],
          [
            271.0,
            248.0
          ]
        ]
      ]
    },
    {
      "id": "v4-ex5-gross",
      "label": "Elevation4 \u00b7 EX-5 ACCENT BAND gross projected face",
      "quantity": 1043.6399999999999,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Design-class face before openings. Approximate traced hatch boundaries; no material selection inferred. Excludes fields assigned to preceding classes. Gross and net rows are alternatives, never additive. Projecting returns, joints and concealed faces not included.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "polygons": [
        [
          [
            947.0,
            898.0
          ],
          [
            947.0,
            885.0
          ],
          [
            290.0,
            885.0
          ],
          [
            290.0,
            898.0
          ],
          [
            947.0,
            898.0
          ]
        ],
        [
          [
            1396.0,
            898.0
          ],
          [
            1396.0,
            885.0
          ],
          [
            1161.0,
            885.0
          ],
          [
            1161.0,
            898.0
          ],
          [
            1396.0,
            898.0
          ]
        ],
        [
          [
            947.0,
            963.0
          ],
          [
            947.0,
            950.0
          ],
          [
            290.0,
            950.0
          ],
          [
            290.0,
            963.0
          ],
          [
            947.0,
            963.0
          ]
        ],
        [
          [
            1396.0,
            963.0
          ],
          [
            1396.0,
            950.0
          ],
          [
            1161.0,
            950.0
          ],
          [
            1161.0,
            963.0
          ],
          [
            1396.0,
            963.0
          ]
        ],
        [
          [
            947.0,
            1028.0
          ],
          [
            947.0,
            1015.0
          ],
          [
            290.0,
            1015.0
          ],
          [
            290.0,
            1028.0
          ],
          [
            947.0,
            1028.0
          ]
        ],
        [
          [
            1396.0,
            1028.0
          ],
          [
            1396.0,
            1015.0
          ],
          [
            1161.0,
            1015.0
          ],
          [
            1161.0,
            1028.0
          ],
          [
            1396.0,
            1028.0
          ]
        ],
        [
          [
            947.0,
            1092.0
          ],
          [
            947.0,
            1079.0
          ],
          [
            290.0,
            1079.0
          ],
          [
            290.0,
            1092.0
          ],
          [
            947.0,
            1092.0
          ]
        ],
        [
          [
            1396.0,
            1092.0
          ],
          [
            1396.0,
            1079.0
          ],
          [
            1161.0,
            1079.0
          ],
          [
            1161.0,
            1092.0
          ],
          [
            1396.0,
            1092.0
          ]
        ]
      ]
    },
    {
      "id": "v4-ex5-net",
      "label": "Elevation4 \u00b7 EX-5 ACCENT BAND face less traced openings",
      "quantity": 990.8035091437055,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Same gross face LESS currently traced window/storefront envelopes. PROVISIONAL NET: unkeyed doors, foreground concealment, exact frame sizes and local trim still require reconciliation. Not net installed finish order; no waste/returns.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "polygons": [
        [
          [
            947.0,
            885.0
          ],
          [
            290.0,
            885.0
          ],
          [
            290.0,
            898.0
          ],
          [
            400.34864637586804,
            898.0
          ],
          [
            400.34864637586804,
            896.5326515480324
          ],
          [
            440.34864637586804,
            896.5326515480324
          ],
          [
            440.34864637586804,
            898.0
          ],
          [
            484.8762794777199,
            898.0
          ],
          [
            484.8762794777199,
            896.5326515480324
          ],
          [
            524.8762794777199,
            896.5326515480324
          ],
          [
            524.8762794777199,
            898.0
          ],
          [
            569.4039125795717,
            898.0
          ],
          [
            569.4039125795717,
            896.5326515480324
          ],
          [
            609.4039125795717,
            896.5326515480324
          ],
          [
            609.4039125795717,
            898.0
          ],
          [
            653.9315456814236,
            898.0
          ],
          [
            653.9315456814236,
            896.5326515480324
          ],
          [
            693.9315456814236,
            896.5326515480324
          ],
          [
            693.9315456814236,
            898.0
          ],
          [
            738.4592466001156,
            898.0
          ],
          [
            738.4592466001156,
            896.5326515480324
          ],
          [
            778.4592466001156,
            896.5326515480324
          ],
          [
            778.4592466001156,
            898.0
          ],
          [
            822.9868797019676,
            898.0
          ],
          [
            822.9868797019676,
            896.5326515480324
          ],
          [
            862.9868797019676,
            896.5326515480324
          ],
          [
            862.9868797019676,
            898.0
          ],
          [
            907.5145128038193,
            898.0
          ],
          [
            907.5145128038193,
            896.5326515480324
          ],
          [
            947.0,
            896.5326515480324
          ],
          [
            947.0,
            885.0
          ]
        ],
        [
          [
            1396.0,
            885.0
          ],
          [
            1161.0,
            885.0
          ],
          [
            1161.0,
            898.0
          ],
          [
            1161.2190303096063,
            898.0
          ],
          [
            1161.2190303096063,
            896.5326515480324
          ],
          [
            1201.2190303096063,
            896.5326515480324
          ],
          [
            1201.2190303096063,
            898.0
          ],
          [
            1246.389747902199,
            898.0
          ],
          [
            1246.389747902199,
            896.5326515480324
          ],
          [
            1286.389747902199,
            896.5326515480324
          ],
          [
            1286.389747902199,
            898.0
          ],
          [
            1330.9173810040509,
            898.0
          ],
          [
            1330.9173810040509,
            896.5326515480324
          ],
          [
            1370.9173810040509,
            896.5326515480324
          ],
          [
            1370.9173810040509,
            898.0
          ],
          [
            1396.0,
            898.0
          ],
          [
            1396.0,
            885.0
          ]
        ],
        [
          [
            947.0,
            950.0
          ],
          [
            290.0,
            950.0
          ],
          [
            290.0,
            963.0
          ],
          [
            400.34864637586804,
            963.0
          ],
          [
            400.34864637586804,
            961.0405725549767
          ],
          [
            440.34864637586804,
            961.0405725549767
          ],
          [
            440.34864637586804,
            963.0
          ],
          [
            484.8762794777199,
            963.0
          ],
          [
            484.8762794777199,
            961.0405725549767
          ],
          [
            524.8762794777199,
            961.0405725549767
          ],
          [
            524.8762794777199,
            963.0
          ],
          [
            569.4039125795717,
            963.0
          ],
          [
            569.4039125795717,
            961.0405725549767
          ],
          [
            609.4039125795717,
            961.0405725549767
          ],
          [
            609.4039125795717,
            963.0
          ],
          [
            653.9315456814236,
            963.0
          ],
          [
            653.9315456814236,
            961.0405725549767
          ],
          [
            693.9315456814236,
            961.0405725549767
          ],
          [
            693.9315456814236,
            963.0
          ],
          [
            738.4592466001156,
            963.0
          ],
          [
            738.4592466001156,
            961.0405725549767
          ],
          [
            778.4592466001156,
            961.0405725549767
          ],
          [
            778.4592466001156,
            963.0
          ],
          [
            822.9868797019676,
            963.0
          ],
          [
            822.9868797019676,
            961.0405725549767
          ],
          [
            862.9868797019676,
            961.0405725549767
          ],
          [
            862.9868797019676,
            963.0
          ],
          [
            907.5145128038193,
            963.0
          ],
          [
            907.5145128038193,
            961.0405725549767
          ],
          [
            947.0,
            961.0405725549767
          ],
          [
            947.0,
            950.0
          ]
        ],
        [
          [
            1396.0,
            950.0
          ],
          [
            1161.0,
            950.0
          ],
          [
            1161.0,
            963.0
          ],
          [
            1161.2190303096063,
            963.0
          ],
          [
            1161.2190303096063,
            961.0405725549767
          ],
          [
            1201.2190303096063,
            961.0405725549767
          ],
          [
            1201.2190303096063,
            963.0
          ],
          [
            1246.389747902199,
            963.0
          ],
          [
            1246.389747902199,
            961.0405725549767
          ],
          [
            1286.389747902199,
            961.0405725549767
          ],
          [
            1286.389747902199,
            963.0
          ],
          [
            1330.9173810040509,
            963.0
          ],
          [
            1330.9173810040509,
            961.0405725549767
          ],
          [
            1370.9173810040509,
            961.0405725549767
          ],
          [
            1370.9173810040509,
            963.0
          ],
          [
            1396.0,
            963.0
          ],
          [
            1396.0,
            950.0
          ]
        ],
        [
          [
            947.0,
            1015.0
          ],
          [
            290.0,
            1015.0
          ],
          [
            290.0,
            1028.0
          ],
          [
            400.34864637586804,
            1028.0
          ],
          [
            400.34864637586804,
            1025.5484935619213
          ],
          [
            440.34864637586804,
            1025.5484935619213
          ],
          [
            440.34864637586804,
            1028.0
          ],
          [
            484.8762794777199,
            1028.0
          ],
          [
            484.8762794777199,
            1025.5484935619213
          ],
          [
            524.8762794777199,
            1025.5484935619213
          ],
          [
            524.8762794777199,
            1028.0
          ],
          [
            569.4039125795717,
            1028.0
          ],
          [
            569.4039125795717,
            1025.5484935619213
          ],
          [
            609.4039125795717,
            1025.5484935619213
          ],
          [
            609.4039125795717,
            1028.0
          ],
          [
            653.9315456814236,
            1028.0
          ],
          [
            653.9315456814236,
            1025.5484935619213
          ],
          [
            693.9315456814236,
            1025.5484935619213
          ],
          [
            693.9315456814236,
            1028.0
          ],
          [
            738.4592466001156,
            1028.0
          ],
          [
            738.4592466001156,
            1025.5484935619213
          ],
          [
            778.4592466001156,
            1025.5484935619213
          ],
          [
            778.4592466001156,
            1028.0
          ],
          [
            822.9868797019676,
            1028.0
          ],
          [
            822.9868797019676,
            1025.5484935619213
          ],
          [
            862.9868797019676,
            1025.5484935619213
          ],
          [
            862.9868797019676,
            1028.0
          ],
          [
            907.5145128038193,
            1028.0
          ],
          [
            907.5145128038193,
            1025.5484935619213
          ],
          [
            947.0,
            1025.5484935619213
          ],
          [
            947.0,
            1015.0
          ]
        ],
        [
          [
            1396.0,
            1015.0
          ],
          [
            1161.0,
            1015.0
          ],
          [
            1161.0,
            1028.0
          ],
          [
            1161.2190303096063,
            1028.0
          ],
          [
            1161.2190303096063,
            1025.5484935619213
          ],
          [
            1201.2190303096063,
            1025.5484935619213
          ],
          [
            1201.2190303096063,
            1028.0
          ],
          [
            1246.389747902199,
            1028.0
          ],
          [
            1246.389747902199,
            1025.5484935619213
          ],
          [
            1286.389747902199,
            1025.5484935619213
          ],
          [
            1286.389747902199,
            1028.0
          ],
          [
            1330.9173810040509,
            1028.0
          ],
          [
            1330.9173810040509,
            1025.5484935619213
          ],
          [
            1370.9173810040509,
            1025.5484935619213
          ],
          [
            1370.9173810040509,
            1028.0
          ],
          [
            1396.0,
            1028.0
          ],
          [
            1396.0,
            1015.0
          ]
        ],
        [
          [
            947.0,
            1079.0
          ],
          [
            290.0,
            1079.0
          ],
          [
            290.0,
            1092.0
          ],
          [
            947.0,
            1092.0
          ],
          [
            947.0,
            1079.0
          ]
        ],
        [
          [
            1396.0,
            1079.0
          ],
          [
            1161.0,
            1079.0
          ],
          [
            1161.0,
            1092.0
          ],
          [
            1396.0,
            1092.0
          ],
          [
            1396.0,
            1079.0
          ]
        ]
      ]
    },
    {
      "id": "v4-band-runs",
      "label": "Elevation4 \u00b7 accent-band horizontal runs",
      "quantity": 535.1999999999999,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Projected horizontal runs by distinct band field. Min2-inch proud relief per legend; end returns, backing and actual section depth unresolved.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "lines": [
        [
          [
            290.0,
            891.5
          ],
          [
            947.0,
            891.5
          ]
        ],
        [
          [
            1161.0,
            891.5
          ],
          [
            1396.0,
            891.5
          ]
        ],
        [
          [
            290.0,
            956.5
          ],
          [
            947.0,
            956.5
          ]
        ],
        [
          [
            1161.0,
            956.5
          ],
          [
            1396.0,
            956.5
          ]
        ],
        [
          [
            290.0,
            1021.5
          ],
          [
            947.0,
            1021.5
          ]
        ],
        [
          [
            1161.0,
            1021.5
          ],
          [
            1396.0,
            1021.5
          ]
        ],
        [
          [
            290.0,
            1085.5
          ],
          [
            947.0,
            1085.5
          ]
        ],
        [
          [
            1161.0,
            1085.5
          ],
          [
            1396.0,
            1085.5
          ]
        ]
      ]
    },
    {
      "id": "v4-ex3-gross",
      "label": "Elevation4 \u00b7 EX-3 LINK transition gross projected face",
      "quantity": 1306.7999999999997,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Design-class face before openings. Approximate traced hatch boundaries; no material selection inferred. Excludes fields assigned to preceding classes. Gross and net rows are alternatives, never additive. Projecting returns, joints and concealed faces not included.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "polygons": [
        [
          [
            971.0,
            811.0
          ],
          [
            971.0,
            1163.0
          ],
          [
            1136.0,
            1163.0
          ],
          [
            1136.0,
            811.0
          ],
          [
            971.0,
            811.0
          ]
        ]
      ]
    },
    {
      "id": "v4-ex3-net",
      "label": "Elevation4 \u00b7 EX-3 LINK transition face less traced openings",
      "quantity": 847.7999999999998,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Same gross face LESS currently traced window/storefront envelopes. PROVISIONAL NET: unkeyed doors, foreground concealment, exact frame sizes and local trim still require reconciliation. Not net installed finish order; no waste/returns.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "polygons": [
        [
          [
            971.0,
            1163.0
          ],
          [
            990.2695945457176,
            1163.0
          ],
          [
            990.2695945457176,
            1112.0
          ],
          [
            1030.2695945457176,
            1112.0
          ],
          [
            1030.2695945457176,
            1163.0
          ],
          [
            1074.8493109809028,
            1163.0
          ],
          [
            1074.8493109809028,
            1112.0
          ],
          [
            1114.8493109809028,
            1112.0
          ],
          [
            1114.8493109809028,
            1163.0
          ],
          [
            1136.0,
            1163.0
          ],
          [
            1136.0,
            811.0
          ],
          [
            971.0,
            811.0
          ],
          [
            971.0,
            1163.0
          ]
        ],
        [
          [
            991.7119231047452,
            832.0247305410879
          ],
          [
            1031.7119231047452,
            832.0247305410879
          ],
          [
            1031.7119231047452,
            883.0247305410879
          ],
          [
            991.7119231047452,
            883.0247305410879
          ],
          [
            991.7119231047452,
            832.0247305410879
          ]
        ],
        [
          [
            991.7119231047452,
            896.5326515480324
          ],
          [
            1031.7119231047452,
            896.5326515480324
          ],
          [
            1031.7119231047452,
            947.5326515480324
          ],
          [
            991.7119231047452,
            947.5326515480324
          ],
          [
            991.7119231047452,
            896.5326515480324
          ]
        ],
        [
          [
            1076.2917299623841,
            961.0405725549767
          ],
          [
            1116.2917299623841,
            961.0405725549767
          ],
          [
            1116.2917299623841,
            1012.0405725549767
          ],
          [
            1076.2917299623841,
            1012.0405725549767
          ],
          [
            1076.2917299623841,
            961.0405725549767
          ]
        ],
        [
          [
            1031.7119231047452,
            961.0405725549767
          ],
          [
            1031.7119231047452,
            1012.0405725549767
          ],
          [
            991.7119231047452,
            1012.0405725549767
          ],
          [
            991.7119231047452,
            961.0405725549767
          ],
          [
            1031.7119231047452,
            961.0405725549767
          ]
        ],
        [
          [
            991.7119231047452,
            1025.5484935619213
          ],
          [
            1031.7119231047452,
            1025.5484935619213
          ],
          [
            1031.7119231047452,
            1076.5484935619213
          ],
          [
            991.7119231047452,
            1076.5484935619213
          ],
          [
            991.7119231047452,
            1025.5484935619213
          ]
        ],
        [
          [
            1076.2917299623841,
            832.0247305410879
          ],
          [
            1116.2917299623841,
            832.0247305410879
          ],
          [
            1116.2917299623841,
            883.0247305410879
          ],
          [
            1076.2917299623841,
            883.0247305410879
          ],
          [
            1076.2917299623841,
            832.0247305410879
          ]
        ],
        [
          [
            1076.2917299623841,
            896.5326515480324
          ],
          [
            1116.2917299623841,
            896.5326515480324
          ],
          [
            1116.2917299623841,
            947.5326515480324
          ],
          [
            1076.2917299623841,
            947.5326515480324
          ],
          [
            1076.2917299623841,
            896.5326515480324
          ]
        ],
        [
          [
            1076.2917299623841,
            1025.5484935619213
          ],
          [
            1116.2917299623841,
            1025.5484935619213
          ],
          [
            1116.2917299623841,
            1076.5484935619213
          ],
          [
            1076.2917299623841,
            1076.5484935619213
          ],
          [
            1076.2917299623841,
            1025.5484935619213
          ]
        ]
      ]
    },
    {
      "id": "v4-ex2-gross",
      "label": "Elevation4 \u00b7 EX-2 WRAP projecting frame gross projected face",
      "quantity": 1767.1724999999997,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Design-class face before openings. Approximate traced hatch boundaries; no material selection inferred. Excludes fields assigned to preceding classes. Gross and net rows are alternatives, never additive. Projecting returns, joints and concealed faces not included.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "polygons": [
        [
          [
            947.0,
            898.0
          ],
          [
            947.0,
            950.0
          ],
          [
            947.0,
            963.0
          ],
          [
            947.0,
            1015.0
          ],
          [
            947.0,
            1028.0
          ],
          [
            947.0,
            1079.0
          ],
          [
            947.0,
            1092.0
          ],
          [
            947.0,
            1163.0
          ],
          [
            971.0,
            1163.0
          ],
          [
            971.0,
            820.0
          ],
          [
            971.0,
            811.0
          ],
          [
            971.0,
            800.0
          ],
          [
            290.0,
            800.0
          ],
          [
            172.0,
            800.0
          ],
          [
            172.0,
            1163.0
          ],
          [
            290.0,
            1163.0
          ],
          [
            290.0,
            1092.0
          ],
          [
            290.0,
            1079.0
          ],
          [
            290.0,
            1028.0
          ],
          [
            290.0,
            1015.0
          ],
          [
            290.0,
            963.0
          ],
          [
            290.0,
            950.0
          ],
          [
            290.0,
            898.0
          ],
          [
            290.0,
            885.0
          ],
          [
            290.0,
            820.0
          ],
          [
            947.0,
            820.0
          ],
          [
            947.0,
            885.0
          ],
          [
            947.0,
            898.0
          ]
        ],
        [
          [
            1161.0,
            800.0
          ],
          [
            1136.0,
            800.0
          ],
          [
            1136.0,
            811.0
          ],
          [
            1136.0,
            1163.0
          ],
          [
            1161.0,
            1163.0
          ],
          [
            1161.0,
            1092.0
          ],
          [
            1161.0,
            1079.0
          ],
          [
            1161.0,
            1028.0
          ],
          [
            1161.0,
            1015.0
          ],
          [
            1161.0,
            963.0
          ],
          [
            1161.0,
            950.0
          ],
          [
            1161.0,
            898.0
          ],
          [
            1161.0,
            885.0
          ],
          [
            1161.0,
            820.0
          ],
          [
            1400.0,
            820.0
          ],
          [
            1400.0,
            800.0
          ],
          [
            1161.0,
            800.0
          ]
        ]
      ]
    },
    {
      "id": "v4-ex2-net",
      "label": "Elevation4 \u00b7 EX-2 WRAP projecting frame face less traced openings",
      "quantity": 1763.4071514892582,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Same gross face LESS currently traced window/storefront envelopes. PROVISIONAL NET: unkeyed doors, foreground concealment, exact frame sizes and local trim still require reconciliation. Not net installed finish order; no waste/returns.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "polygons": [
        [
          [
            947.0,
            950.0
          ],
          [
            947.0,
            961.0405725549767
          ],
          [
            947.5145128038193,
            961.0405725549767
          ],
          [
            947.5145128038193,
            1012.0405725549767
          ],
          [
            947.0,
            1012.0405725549767
          ],
          [
            947.0,
            1015.0
          ],
          [
            947.0,
            1025.5484935619213
          ],
          [
            947.5145128038193,
            1025.5484935619213
          ],
          [
            947.5145128038193,
            1076.5484935619213
          ],
          [
            947.0,
            1076.5484935619213
          ],
          [
            947.0,
            1079.0
          ],
          [
            947.0,
            1092.0
          ],
          [
            947.0,
            1163.0
          ],
          [
            971.0,
            1163.0
          ],
          [
            971.0,
            820.0
          ],
          [
            971.0,
            811.0
          ],
          [
            971.0,
            800.0
          ],
          [
            290.0,
            800.0
          ],
          [
            172.0,
            800.0
          ],
          [
            172.0,
            1163.0
          ],
          [
            290.0,
            1163.0
          ],
          [
            290.0,
            1092.0
          ],
          [
            290.0,
            1079.0
          ],
          [
            290.0,
            1028.0
          ],
          [
            290.0,
            1015.0
          ],
          [
            290.0,
            963.0
          ],
          [
            290.0,
            950.0
          ],
          [
            290.0,
            898.0
          ],
          [
            290.0,
            885.0
          ],
          [
            290.0,
            820.0
          ],
          [
            947.0,
            820.0
          ],
          [
            947.0,
            832.0247305410879
          ],
          [
            947.5145128038193,
            832.0247305410879
          ],
          [
            947.5145128038193,
            883.0247305410879
          ],
          [
            947.0,
            883.0247305410879
          ],
          [
            947.0,
            885.0
          ],
          [
            947.0,
            896.5326515480324
          ],
          [
            947.5145128038193,
            896.5326515480324
          ],
          [
            947.5145128038193,
            947.5326515480324
          ],
          [
            947.0,
            947.5326515480324
          ],
          [
            947.0,
            950.0
          ]
        ],
        [
          [
            1136.0,
            800.0
          ],
          [
            1136.0,
            811.0
          ],
          [
            1136.0,
            1163.0
          ],
          [
            1159.7767017505785,
            1163.0
          ],
          [
            1159.7767017505785,
            1112.0
          ],
          [
            1161.0,
            1112.0
          ],
          [
            1161.0,
            1092.0
          ],
          [
            1161.0,
            1079.0
          ],
          [
            1161.0,
            1028.0
          ],
          [
            1161.0,
            1015.0
          ],
          [
            1161.0,
            963.0
          ],
          [
            1161.0,
            950.0
          ],
          [
            1161.0,
            898.0
          ],
          [
            1161.0,
            885.0
          ],
          [
            1161.0,
            820.0
          ],
          [
            1400.0,
            820.0
          ],
          [
            1400.0,
            800.0
          ],
          [
            1161.0,
            800.0
          ],
          [
            1136.0,
            800.0
          ]
        ]
      ]
    },
    {
      "id": "v4-ex1-gross",
      "label": "Elevation4 \u00b7 EX-1 CORE body gross projected face",
      "quantity": 5840.369999999999,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Design-class face before openings. Approximate traced hatch boundaries; no material selection inferred. Excludes fields assigned to preceding classes. Gross and net rows are alternatives, never additive. Projecting returns, joints and concealed faces not included.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "polygons": [
        [
          [
            290.0,
            820.0
          ],
          [
            290.0,
            885.0
          ],
          [
            947.0,
            885.0
          ],
          [
            947.0,
            820.0
          ],
          [
            290.0,
            820.0
          ]
        ],
        [
          [
            1161.0,
            820.0
          ],
          [
            1161.0,
            885.0
          ],
          [
            1396.0,
            885.0
          ],
          [
            1396.0,
            820.0
          ],
          [
            1161.0,
            820.0
          ]
        ],
        [
          [
            290.0,
            898.0
          ],
          [
            290.0,
            950.0
          ],
          [
            947.0,
            950.0
          ],
          [
            947.0,
            898.0
          ],
          [
            290.0,
            898.0
          ]
        ],
        [
          [
            1161.0,
            950.0
          ],
          [
            1396.0,
            950.0
          ],
          [
            1396.0,
            898.0
          ],
          [
            1161.0,
            898.0
          ],
          [
            1161.0,
            950.0
          ]
        ],
        [
          [
            290.0,
            1015.0
          ],
          [
            947.0,
            1015.0
          ],
          [
            947.0,
            963.0
          ],
          [
            290.0,
            963.0
          ],
          [
            290.0,
            1015.0
          ]
        ],
        [
          [
            1161.0,
            963.0
          ],
          [
            1161.0,
            1015.0
          ],
          [
            1396.0,
            1015.0
          ],
          [
            1396.0,
            963.0
          ],
          [
            1161.0,
            963.0
          ]
        ],
        [
          [
            290.0,
            1028.0
          ],
          [
            290.0,
            1079.0
          ],
          [
            947.0,
            1079.0
          ],
          [
            947.0,
            1028.0
          ],
          [
            290.0,
            1028.0
          ]
        ],
        [
          [
            1161.0,
            1028.0
          ],
          [
            1161.0,
            1079.0
          ],
          [
            1396.0,
            1079.0
          ],
          [
            1396.0,
            1028.0
          ],
          [
            1161.0,
            1028.0
          ]
        ],
        [
          [
            290.0,
            1163.0
          ],
          [
            947.0,
            1163.0
          ],
          [
            947.0,
            1092.0
          ],
          [
            290.0,
            1092.0
          ],
          [
            290.0,
            1163.0
          ]
        ],
        [
          [
            1161.0,
            1163.0
          ],
          [
            1396.0,
            1163.0
          ],
          [
            1396.0,
            1092.0
          ],
          [
            1161.0,
            1092.0
          ],
          [
            1161.0,
            1163.0
          ]
        ]
      ]
    },
    {
      "id": "v4-ex1-net",
      "label": "Elevation4 \u00b7 EX-1 CORE body face less traced openings",
      "quantity": 3879.171839367036,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Same gross face LESS currently traced window/storefront envelopes. PROVISIONAL NET: unkeyed doors, foreground concealment, exact frame sizes and local trim still require reconciliation. Not net installed finish order; no waste/returns.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "polygons": [
        [
          [
            290.0,
            885.0
          ],
          [
            947.0,
            885.0
          ],
          [
            947.0,
            883.0247305410879
          ],
          [
            907.5145128038193,
            883.0247305410879
          ],
          [
            907.5145128038193,
            832.0247305410879
          ],
          [
            947.0,
            832.0247305410879
          ],
          [
            947.0,
            820.0
          ],
          [
            290.0,
            820.0
          ],
          [
            290.0,
            885.0
          ]
        ],
        [
          [
            440.34864637586804,
            832.0247305410879
          ],
          [
            440.34864637586804,
            883.0247305410879
          ],
          [
            400.34864637586804,
            883.0247305410879
          ],
          [
            400.34864637586804,
            832.0247305410879
          ],
          [
            440.34864637586804,
            832.0247305410879
          ]
        ],
        [
          [
            484.8762794777199,
            832.0247305410879
          ],
          [
            524.8762794777199,
            832.0247305410879
          ],
          [
            524.8762794777199,
            883.0247305410879
          ],
          [
            484.8762794777199,
            883.0247305410879
          ],
          [
            484.8762794777199,
            832.0247305410879
          ]
        ],
        [
          [
            569.4039125795717,
            832.0247305410879
          ],
          [
            609.4039125795717,
            832.0247305410879
          ],
          [
            609.4039125795717,
            883.0247305410879
          ],
          [
            569.4039125795717,
            883.0247305410879
          ],
          [
            569.4039125795717,
            832.0247305410879
          ]
        ],
        [
          [
            693.9315456814236,
            832.0247305410879
          ],
          [
            693.9315456814236,
            883.0247305410879
          ],
          [
            653.9315456814236,
            883.0247305410879
          ],
          [
            653.9315456814236,
            832.0247305410879
          ],
          [
            693.9315456814236,
            832.0247305410879
          ]
        ],
        [
          [
            822.9868797019676,
            832.0247305410879
          ],
          [
            862.9868797019676,
            832.0247305410879
          ],
          [
            862.9868797019676,
            883.0247305410879
          ],
          [
            822.9868797019676,
            883.0247305410879
          ],
          [
            822.9868797019676,
            832.0247305410879
          ]
        ],
        [
          [
            738.4592466001156,
            832.0247305410879
          ],
          [
            778.4592466001156,
            832.0247305410879
          ],
          [
            778.4592466001156,
            883.0247305410879
          ],
          [
            738.4592466001156,
            883.0247305410879
          ],
          [
            738.4592466001156,
            832.0247305410879
          ]
        ],
        [
          [
            1161.0,
            885.0
          ],
          [
            1396.0,
            885.0
          ],
          [
            1396.0,
            820.0
          ],
          [
            1161.0,
            820.0
          ],
          [
            1161.0,
            885.0
          ]
        ],
        [
          [
            1330.9173810040509,
            832.0247305410879
          ],
          [
            1370.9173810040509,
            832.0247305410879
          ],
          [
            1370.9173810040509,
            883.0247305410879
          ],
          [
            1330.9173810040509,
            883.0247305410879
          ],
          [
            1330.9173810040509,
            832.0247305410879
          ]
        ],
        [
          [
            1246.389747902199,
            832.0247305410879
          ],
          [
            1286.389747902199,
            832.0247305410879
          ],
          [
            1286.389747902199,
            883.0247305410879
          ],
          [
            1246.389747902199,
            883.0247305410879
          ],
          [
            1246.389747902199,
            832.0247305410879
          ]
        ],
        [
          [
            1161.2190303096063,
            832.0247305410879
          ],
          [
            1201.2190303096063,
            832.0247305410879
          ],
          [
            1201.2190303096063,
            883.0247305410879
          ],
          [
            1161.2190303096063,
            883.0247305410879
          ],
          [
            1161.2190303096063,
            832.0247305410879
          ]
        ],
        [
          [
            290.0,
            950.0
          ],
          [
            947.0,
            950.0
          ],
          [
            947.0,
            947.5326515480324
          ],
          [
            907.5145128038193,
            947.5326515480324
          ],
          [
            907.5145128038193,
            898.0
          ],
          [
            862.9868797019676,
            898.0
          ],
          [
            862.9868797019676,
            947.5326515480324
          ],
          [
            822.9868797019676,
            947.5326515480324
          ],
          [
            822.9868797019676,
            898.0
          ],
          [
            778.4592466001156,
            898.0
          ],
          [
            778.4592466001156,
            947.5326515480324
          ],
          [
            738.4592466001156,
            947.5326515480324
          ],
          [
            738.4592466001156,
            898.0
          ],
          [
            693.9315456814236,
            898.0
          ],
          [
            693.9315456814236,
            947.5326515480324
          ],
          [
            653.9315456814236,
            947.5326515480324
          ],
          [
            653.9315456814236,
            898.0
          ],
          [
            609.4039125795717,
            898.0
          ],
          [
            609.4039125795717,
            947.5326515480324
          ],
          [
            569.4039125795717,
            947.5326515480324
          ],
          [
            569.4039125795717,
            898.0
          ],
          [
            524.8762794777199,
            898.0
          ],
          [
            524.8762794777199,
            947.5326515480324
          ],
          [
            484.8762794777199,
            947.5326515480324
          ],
          [
            484.8762794777199,
            898.0
          ],
          [
            440.34864637586804,
            898.0
          ],
          [
            440.34864637586804,
            947.5326515480324
          ],
          [
            400.34864637586804,
            947.5326515480324
          ],
          [
            400.34864637586804,
            898.0
          ],
          [
            290.0,
            898.0
          ],
          [
            290.0,
            950.0
          ]
        ],
        [
          [
            1396.0,
            950.0
          ],
          [
            1396.0,
            898.0
          ],
          [
            1370.9173810040509,
            898.0
          ],
          [
            1370.9173810040509,
            947.5326515480324
          ],
          [
            1330.9173810040509,
            947.5326515480324
          ],
          [
            1330.9173810040509,
            898.0
          ],
          [
            1286.389747902199,
            898.0
          ],
          [
            1286.389747902199,
            947.5326515480324
          ],
          [
            1246.389747902199,
            947.5326515480324
          ],
          [
            1246.389747902199,
            898.0
          ],
          [
            1201.2190303096063,
            898.0
          ],
          [
            1201.2190303096063,
            947.5326515480324
          ],
          [
            1161.2190303096063,
            947.5326515480324
          ],
          [
            1161.2190303096063,
            898.0
          ],
          [
            1161.0,
            898.0
          ],
          [
            1161.0,
            950.0
          ],
          [
            1396.0,
            950.0
          ]
        ],
        [
          [
            947.0,
            1015.0
          ],
          [
            947.0,
            1012.0405725549767
          ],
          [
            907.5145128038193,
            1012.0405725549767
          ],
          [
            907.5145128038193,
            963.0
          ],
          [
            862.9868797019676,
            963.0
          ],
          [
            862.9868797019676,
            1012.0405725549767
          ],
          [
            822.9868797019676,
            1012.0405725549767
          ],
          [
            822.9868797019676,
            963.0
          ],
          [
            778.4592466001156,
            963.0
          ],
          [
            778.4592466001156,
            1012.0405725549767
          ],
          [
            738.4592466001156,
            1012.0405725549767
          ],
          [
            738.4592466001156,
            963.0
          ],
          [
            693.9315456814236,
            963.0
          ],
          [
            693.9315456814236,
            1012.0405725549767
          ],
          [
            653.9315456814236,
            1012.0405725549767
          ],
          [
            653.9315456814236,
            963.0
          ],
          [
            609.4039125795717,
            963.0
          ],
          [
            609.4039125795717,
            1012.0405725549767
          ],
          [
            569.4039125795717,
            1012.0405725549767
          ],
          [
            569.4039125795717,
            963.0
          ],
          [
            524.8762794777199,
            963.0
          ],
          [
            524.8762794777199,
            1012.0405725549767
          ],
          [
            484.8762794777199,
            1012.0405725549767
          ],
          [
            484.8762794777199,
            963.0
          ],
          [
            440.34864637586804,
            963.0
          ],
          [
            440.34864637586804,
            1012.0405725549767
          ],
          [
            400.34864637586804,
            1012.0405725549767
          ],
          [
            400.34864637586804,
            963.0
          ],
          [
            290.0,
            963.0
          ],
          [
            290.0,
            1015.0
          ],
          [
            947.0,
            1015.0
          ]
        ],
        [
          [
            1161.0,
            1015.0
          ],
          [
            1396.0,
            1015.0
          ],
          [
            1396.0,
            963.0
          ],
          [
            1370.9173810040509,
            963.0
          ],
          [
            1370.9173810040509,
            1012.0405725549767
          ],
          [
            1330.9173810040509,
            1012.0405725549767
          ],
          [
            1330.9173810040509,
            963.0
          ],
          [
            1286.389747902199,
            963.0
          ],
          [
            1286.389747902199,
            1012.0405725549767
          ],
          [
            1246.389747902199,
            1012.0405725549767
          ],
          [
            1246.389747902199,
            963.0
          ],
          [
            1201.2190303096063,
            963.0
          ],
          [
            1201.2190303096063,
            1012.0405725549767
          ],
          [
            1161.2190303096063,
            1012.0405725549767
          ],
          [
            1161.2190303096063,
            963.0
          ],
          [
            1161.0,
            963.0
          ],
          [
            1161.0,
            1015.0
          ]
        ],
        [
          [
            290.0,
            1079.0
          ],
          [
            947.0,
            1079.0
          ],
          [
            947.0,
            1076.5484935619213
          ],
          [
            907.5145128038193,
            1076.5484935619213
          ],
          [
            907.5145128038193,
            1028.0
          ],
          [
            862.9868797019676,
            1028.0
          ],
          [
            862.9868797019676,
            1076.5484935619213
          ],
          [
            822.9868797019676,
            1076.5484935619213
          ],
          [
            822.9868797019676,
            1028.0
          ],
          [
            778.4592466001156,
            1028.0
          ],
          [
            778.4592466001156,
            1076.5484935619213
          ],
          [
            738.4592466001156,
            1076.5484935619213
          ],
          [
            738.4592466001156,
            1028.0
          ],
          [
            693.9315456814236,
            1028.0
          ],
          [
            693.9315456814236,
            1076.5484935619213
          ],
          [
            653.9315456814236,
            1076.5484935619213
          ],
          [
            653.9315456814236,
            1028.0
          ],
          [
            609.4039125795717,
            1028.0
          ],
          [
            609.4039125795717,
            1076.5484935619213
          ],
          [
            569.4039125795717,
            1076.5484935619213
          ],
          [
            569.4039125795717,
            1028.0
          ],
          [
            524.8762794777199,
            1028.0
          ],
          [
            524.8762794777199,
            1076.5484935619213
          ],
          [
            484.8762794777199,
            1076.5484935619213
          ],
          [
            484.8762794777199,
            1028.0
          ],
          [
            440.34864637586804,
            1028.0
          ],
          [
            440.34864637586804,
            1076.5484935619213
          ],
          [
            400.34864637586804,
            1076.5484935619213
          ],
          [
            400.34864637586804,
            1028.0
          ],
          [
            290.0,
            1028.0
          ],
          [
            290.0,
            1079.0
          ]
        ],
        [
          [
            1161.0,
            1079.0
          ],
          [
            1396.0,
            1079.0
          ],
          [
            1396.0,
            1028.0
          ],
          [
            1370.9173810040509,
            1028.0
          ],
          [
            1370.9173810040509,
            1076.5484935619213
          ],
          [
            1330.9173810040509,
            1076.5484935619213
          ],
          [
            1330.9173810040509,
            1028.0
          ],
          [
            1286.389747902199,
            1028.0
          ],
          [
            1286.389747902199,
            1076.5484935619213
          ],
          [
            1246.389747902199,
            1076.5484935619213
          ],
          [
            1246.389747902199,
            1028.0
          ],
          [
            1201.2190303096063,
            1028.0
          ],
          [
            1201.2190303096063,
            1076.5484935619213
          ],
          [
            1161.2190303096063,
            1076.5484935619213
          ],
          [
            1161.2190303096063,
            1028.0
          ],
          [
            1161.0,
            1028.0
          ],
          [
            1161.0,
            1079.0
          ]
        ],
        [
          [
            947.0,
            1163.0
          ],
          [
            947.0,
            1092.0
          ],
          [
            290.0,
            1092.0
          ],
          [
            290.0,
            1163.0
          ],
          [
            947.0,
            1163.0
          ]
        ],
        [
          [
            778.9530210141781,
            1107.9639304832176
          ],
          [
            778.9530210141781,
            1156.9639304832176
          ],
          [
            738.9530210141781,
            1156.9639304832176
          ],
          [
            738.9530210141781,
            1107.9639304832176
          ],
          [
            778.9530210141781,
            1107.9639304832176
          ]
        ],
        [
          [
            1244.9473289207176,
            1163.0
          ],
          [
            1244.9473289207176,
            1112.0
          ],
          [
            1284.9473289207176,
            1112.0
          ],
          [
            1284.9473289207176,
            1163.0
          ],
          [
            1329.4749620225693,
            1163.0
          ],
          [
            1329.4749620225693,
            1112.0
          ],
          [
            1369.4749620225693,
            1112.0
          ],
          [
            1369.4749620225693,
            1163.0
          ],
          [
            1396.0,
            1163.0
          ],
          [
            1396.0,
            1092.0
          ],
          [
            1161.0,
            1092.0
          ],
          [
            1161.0,
            1112.0
          ],
          [
            1199.7767017505785,
            1112.0
          ],
          [
            1199.7767017505785,
            1163.0
          ],
          [
            1244.9473289207176,
            1163.0
          ]
        ]
      ]
    },
    {
      "id": "v4-classified-envelope",
      "label": "Elevation4 \u00b7 combined classified face reference",
      "quantity": 9957.982499999998,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Combined reference envelope of traced finish classes. Includes openings before deduction; do not add to class rows. Foreground fences, gates and appendages may overlap the building behind them and require separate reconciliation.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "polygons": [
        [
          [
            1161.0,
            1163.0
          ],
          [
            1396.0,
            1163.0
          ],
          [
            1396.0,
            1092.0
          ],
          [
            1396.0,
            1079.0
          ],
          [
            1396.0,
            1028.0
          ],
          [
            1396.0,
            1015.0
          ],
          [
            1396.0,
            963.0
          ],
          [
            1396.0,
            950.0
          ],
          [
            1396.0,
            898.0
          ],
          [
            1396.0,
            885.0
          ],
          [
            1396.0,
            820.0
          ],
          [
            1400.0,
            820.0
          ],
          [
            1400.0,
            800.0
          ],
          [
            1161.0,
            800.0
          ],
          [
            1136.0,
            800.0
          ],
          [
            1136.0,
            811.0
          ],
          [
            971.0,
            811.0
          ],
          [
            971.0,
            800.0
          ],
          [
            290.0,
            800.0
          ],
          [
            172.0,
            800.0
          ],
          [
            172.0,
            1163.0
          ],
          [
            290.0,
            1163.0
          ],
          [
            947.0,
            1163.0
          ],
          [
            971.0,
            1163.0
          ],
          [
            1136.0,
            1163.0
          ],
          [
            1161.0,
            1163.0
          ]
        ]
      ]
    },
    {
      "id": "v3-roof-profile",
      "label": "Elevation3 \u00b7 parapet / feature top profile",
      "quantity": 87.45,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Visible projected top profile including vertical steps. Not a complete coping/gravel-stop order: resolve roof corners, actual returns, materials and overlap with adjoining elevations.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "line": [
        [
          271,
          228
        ],
        [
          285,
          228
        ],
        [
          285,
          183
        ],
        [
          397,
          183
        ],
        [
          397,
          228
        ],
        [
          764,
          228
        ]
      ]
    },
    {
      "id": "v4-roof-profile",
      "label": "Elevation4 \u00b7 parapet / feature top profile",
      "quantity": 187.5,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Visible projected top profile including vertical steps. Not a complete coping/gravel-stop order: resolve roof corners, actual returns, materials and overlap with adjoining elevations.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "line": [
        [
          172,
          800
        ],
        [
          971,
          800
        ],
        [
          971,
          811
        ],
        [
          1136,
          811
        ],
        [
          1136,
          800
        ],
        [
          1400,
          800
        ]
      ]
    },
    {
      "id": "foreground-gate",
      "label": "Elevation3 foreground gate reference",
      "quantity": 8.7,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Projected foreground gate/screen; may repeat gate on adjacent elevation2. Match site location before count/length aggregation.",
      "sourceSheet": "A4.2",
      "parentSheet": "Exterior",
      "line": [
        [
          215,
          551
        ],
        [
          273,
          551
        ]
      ]
    }
  ]
}
