  "sheet": "A3.6",
  "coordinateSpace": {
    "width": 1920,
    "height": 1280
  },
  "calibration": {
    "pixelsPerFoot": 10,
    "printedScale": "3/16 inch = 1 foot",
    "checks": [
      {
        "view": "Printed scale",
        "pixelsPerFoot": 10,
        "basis": "3/16 inch =1 foot"
      },
      {
        "view": "Shared grid6\u20137 vs dimensioned A2.16",
        "sourcePixels": 126.792,
        "referenceFeet": 12.666666666666666
      },
      {
        "view": "Shared grid14\u201315 vs dimensioned A2.16",
        "sourcePixels": 166.831,
        "referenceFeet": 16.666666666666668
      }
    ]
  },
  "rows": [
    {
      "id": "110-main",
      "label": "110 main ceiling",
      "quantity": 221.06249999999997,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            171.23450000000003,
            597.405
          ],
          [
            283.7345,
            597.405
          ],
          [
            283.7345,
            793.905
          ],
          [
            171.23450000000003,
            793.905
          ]
        ]
      ]
    },
    {
      "id": "110-service",
      "label": "110 entry / bath ceiling band",
      "quantity": 86.06249999999999,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum-board hatch. Height: Local RCP height not tagged. Approximate clear horizontal trace; Gross band before partitions/ceiling-break deductions. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            171.23450000000003,
            511.905
          ],
          [
            283.7345,
            511.905
          ],
          [
            283.7345,
            588.405
          ],
          [
            171.23450000000003,
            588.405
          ]
        ]
      ]
    },
    {
      "id": "112-main",
      "label": "112 main ceiling",
      "quantity": 221.06249999999997,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            297.2345,
            597.405
          ],
          [
            409.7345,
            597.405
          ],
          [
            409.7345,
            793.905
          ],
          [
            297.2345,
            793.905
          ]
        ]
      ]
    },
    {
      "id": "112-service",
      "label": "112 entry / bath ceiling band",
      "quantity": 86.06249999999999,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: Local RCP height not tagged. Approximate clear horizontal trace; Gross band before partitions/ceiling-break deductions. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            297.2345,
            511.905
          ],
          [
            409.7345,
            511.905
          ],
          [
            409.7345,
            588.405
          ],
          [
            297.2345,
            588.405
          ]
        ]
      ]
    },
    {
      "id": "114-main",
      "label": "114 main ceiling",
      "quantity": 221.06249999999997,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            424.7345,
            597.405
          ],
          [
            537.2345,
            597.405
          ],
          [
            537.2345,
            793.905
          ],
          [
            424.7345,
            793.905
          ]
        ]
      ]
    },
    {
      "id": "114-service",
      "label": "114 entry / bath ceiling band",
      "quantity": 86.06249999999999,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: Local RCP height not tagged. Approximate clear horizontal trace; Gross band before partitions/ceiling-break deductions. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            424.7345,
            511.905
          ],
          [
            537.2345,
            511.905
          ],
          [
            537.2345,
            588.405
          ],
          [
            424.7345,
            588.405
          ]
        ]
      ]
    },
    {
      "id": "public-109",
      "label": "109 Mechanical ceiling / open zone",
      "quantity": 177.18749999999997,
      "unit": "SF",
      "color": "#299bba",
      "basis": "OPEN CEILING. Height: Open; no finish ceiling. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            169.73450000000003,
            157.90499999999997
          ],
          [
            282.2345,
            157.90499999999997
          ],
          [
            282.2345,
            315.405
          ],
          [
            169.73450000000003,
            315.405
          ]
        ]
      ]
    },
    {
      "id": "public-111",
      "label": "111 Engineer ceiling / open zone",
      "quantity": 101.24999999999999,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "2x2 grid hatch. Height: Height not shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            169.73450000000003,
            327.405
          ],
          [
            282.2345,
            327.405
          ],
          [
            282.2345,
            417.405
          ],
          [
            169.73450000000003,
            417.405
          ]
        ]
      ]
    },
    {
      "id": "public-113",
      "label": "113 Electrical ceiling / open zone",
      "quantity": 133.38,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "OPEN CEILING. Height: Open; no finish ceiling. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            295.7345,
            157.90499999999997
          ],
          [
            409.7345,
            157.90499999999997
          ],
          [
            409.7345,
            274.905
          ],
          [
            295.7345,
            274.905
          ]
        ]
      ]
    },
    {
      "id": "public-115",
      "label": "115 PBX ceiling / open zone",
      "quantity": 73.52999999999999,
      "unit": "SF",
      "color": "#398d79",
      "basis": "OPEN CEILING. Height: Open; no finish ceiling. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            295.7345,
            291.405
          ],
          [
            409.7345,
            291.405
          ],
          [
            409.7345,
            355.905
          ],
          [
            295.7345,
            355.905
          ]
        ]
      ]
    },
    {
      "id": "public-117",
      "label": "117 Employee breakroom ceiling / open zone",
      "quantity": 128.20499999999998,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "2x2 grid hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            423.2345,
            157.90499999999997
          ],
          [
            534.2345,
            157.90499999999997
          ],
          [
            534.2345,
            273.405
          ],
          [
            423.2345,
            273.405
          ]
        ]
      ]
    },
    {
      "id": "public-119",
      "label": "119 Food prep ceiling / open zone",
      "quantity": 265.8375,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "2x2 grid hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            295.7345,
            370.905
          ],
          [
            423.2345,
            370.905
          ],
          [
            423.2345,
            291.405
          ],
          [
            535.7345,
            291.405
          ],
          [
            535.7345,
            444.405
          ],
          [
            295.7345,
            444.405
          ]
        ]
      ]
    },
    {
      "id": "public-121",
      "label": "121 Proposed sprinkler room ceiling / open zone",
      "quantity": 90.945,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            550.7345,
            157.90499999999997
          ],
          [
            691.7345,
            157.90499999999997
          ],
          [
            691.7345,
            222.40499999999997
          ],
          [
            550.7345,
            222.40499999999997
          ]
        ]
      ]
    },
    {
      "id": "public-125",
      "label": "125 Dryer room ceiling / open zone",
      "quantity": 57.91499999999999,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "2x2 grid hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            705.2345,
            157.90499999999997
          ],
          [
            804.2345,
            157.90499999999997
          ],
          [
            804.2345,
            216.40499999999997
          ],
          [
            705.2345,
            216.40499999999997
          ]
        ]
      ]
    },
    {
      "id": "public-131",
      "label": "131 Laundry discharge ceiling / open zone",
      "quantity": 104.89499999999998,
      "unit": "SF",
      "color": "#299bba",
      "basis": "2x2 grid hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            970.7345,
            157.90499999999997
          ],
          [
            1081.7345,
            157.90499999999997
          ],
          [
            1081.7345,
            252.40499999999997
          ],
          [
            970.7345,
            252.40499999999997
          ]
        ]
      ]
    },
    {
      "id": "public-133",
      "label": "133 Manager office ceiling / open zone",
      "quantity": 69.92999999999999,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "2x2 grid hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            970.7345,
            289.905
          ],
          [
            1081.7345,
            289.905
          ],
          [
            1081.7345,
            352.905
          ],
          [
            970.7345,
            352.905
          ]
        ]
      ]
    },
    {
      "id": "public-116",
      "label": "116 Women ceiling / open zone",
      "quantity": 48.23999999999737,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: 8 feet 6 inches shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            592.2350000000001,
            544.905
          ],
          [
            664.2349999999999,
            544.905
          ],
          [
            664.2349999999999,
            611.905
          ],
          [
            592.2350000000001,
            611.905
          ]
        ]
      ]
    },
    {
      "id": "public-118",
      "label": "118 Men ceiling / open zone",
      "quantity": 48.23999999999737,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: 8 feet 6 inches shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            592.2350000000001,
            619.905
          ],
          [
            664.2349999999999,
            619.905
          ],
          [
            664.2349999999999,
            686.905
          ],
          [
            592.2350000000001,
            686.905
          ]
        ]
      ]
    },
    {
      "id": "public-120",
      "label": "120 Storage ceiling / open zone",
      "quantity": 46.8,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: 8 feet 6 inches shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            592.2350000000001,
            695.905
          ],
          [
            664.2349999999999,
            695.905
          ],
          [
            664.2349999999999,
            760.905
          ],
          [
            592.2350000000001,
            760.905
          ]
        ]
      ]
    },
    {
      "id": "public-122",
      "label": "122 Sales ceiling / open zone",
      "quantity": 59.03999999999999,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "2x2 grid hatch. Height: 9 feet 3 inches shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            592.2350000000001,
            768.905
          ],
          [
            664.2349999999999,
            768.905
          ],
          [
            664.2349999999999,
            850.905
          ],
          [
            592.2350000000001,
            850.905
          ]
        ]
      ]
    },
    {
      "id": "public-132",
      "label": "132 Guest laundry ceiling / open zone",
      "quantity": 148.1999999999991,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: 9 feet 3 inches shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            1182.2350000000001,
            522.905
          ],
          [
            1338.2350000000001,
            522.905
          ],
          [
            1338.2350000000001,
            617.905
          ],
          [
            1182.2350000000001,
            617.905
          ]
        ]
      ]
    },
    {
      "id": "public-135",
      "label": "135 TV lounge ceiling / open zone",
      "quantity": 149.76,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Painted gypsum-board hatch. Height: 8 feet 10 inches shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            1182.2350000000001,
            414.90499999999986
          ],
          [
            1338.2350000000001,
            414.90499999999986
          ],
          [
            1338.2350000000001,
            510.905
          ],
          [
            1182.2350000000001,
            510.905
          ]
        ]
      ]
    },
    {
      "id": "public-127",
      "label": "127 Laundry circulation ceiling / open zone",
      "quantity": 296.97749999999996,
      "unit": "SF",
      "color": "#299bba",
      "basis": "2x2 grid hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            550.7345,
            229.90499999999997
          ],
          [
            700.7345,
            229.90499999999997
          ],
          [
            700.7345,
            222.40499999999997
          ],
          [
            810.2345,
            222.40499999999997
          ],
          [
            810.2345,
            157.90499999999997
          ],
          [
            957.2345,
            157.90499999999997
          ],
          [
            957.2345,
            274.905
          ],
          [
            550.7345,
            274.905
          ]
        ]
      ]
    },
    {
      "id": "public-136",
      "label": "136 Servery strip ceiling / open zone",
      "quantity": 144.42749999999998,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: 8 feet 10 inches shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            550.7345,
            291.405
          ],
          [
            747.2345,
            291.405
          ],
          [
            747.2345,
            364.905
          ],
          [
            550.7345,
            364.905
          ]
        ]
      ]
    },
    {
      "id": "public-137",
      "label": "137 Workstation strip ceiling / open zone",
      "quantity": 130.61249999999998,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: 8 feet 10 inches shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            754.7345,
            291.405
          ],
          [
            957.2345,
            291.405
          ],
          [
            957.2345,
            355.905
          ],
          [
            754.7345,
            355.905
          ]
        ]
      ]
    },
    {
      "id": "public-123",
      "label": "123 Breakfast zone ceiling / open zone",
      "quantity": 137.16,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: 8 feet 10 inches shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            550.7345,
            372.405
          ],
          [
            741.2345,
            372.405
          ],
          [
            741.2345,
            444.405
          ],
          [
            550.7345,
            444.405
          ]
        ]
      ]
    },
    {
      "id": "lobby-act",
      "label": "124 lobby inset acoustic field",
      "quantity": 340.67249999999996,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "6x48 acoustic-tile hatch (cross-reference A3.2 legend). Height: 9 feet 6 inches shown. Approximate clear horizontal trace; Panel count/waste not derived from partial edge tiles. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            729.2345,
            589.905
          ],
          [
            949.7345,
            589.905
          ],
          [
            949.7345,
            744.405
          ],
          [
            729.2345,
            744.405
          ]
        ]
      ]
    },
    {
      "id": "lobby-gb",
      "label": "124 lobby surrounding ceiling",
      "quantity": 792.6075000000001,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Painted gypsum-board hatch. Height: 8 feet 10 inches shown. Approximate clear horizontal trace; Inset acoustic field excluded. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            670.7345,
            507.405
          ],
          [
            1042.7345,
            507.405
          ],
          [
            1042.7345,
            768.405
          ],
          [
            916.7345,
            768.405
          ],
          [
            916.7345,
            834.405
          ],
          [
            670.7345,
            834.405
          ]
        ],
        [
          [
            729.2345,
            589.905
          ],
          [
            949.7345,
            589.905
          ],
          [
            949.7345,
            744.405
          ],
          [
            729.2345,
            744.405
          ]
        ]
      ]
    },
    {
      "id": "lobby-inset-edge",
      "label": "Lobby inset ceiling perimeter",
      "quantity": 75.0,
      "unit": "LF",
      "color": "#cf4f62",
      "basis": "Interface edge, not automatically installed trim. Height difference shown8 inches; edge profiles/supports require section. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "line": [
        [
          729.2345,
          589.905
        ],
        [
          949.7345,
          589.905
        ],
        [
          949.7345,
          744.405
        ],
        [
          729.2345,
          744.405
        ],
        [
          729.2345,
          589.905
        ]
      ]
    },
    {
      "id": "lobby-step-face",
      "label": "Lobby inset step-face allowance",
      "quantity": 50.0,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Geometric perimeter \u00d7 shown8-inch difference. ALLOWANCE only: verify whether inset edge is vertical, open, sloped or concealed before adding to finish scope. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "line": [
        [
          729.2345,
          589.905
        ],
        [
          949.7345,
          589.905
        ],
        [
          949.7345,
          744.405
        ],
        [
          729.2345,
          744.405
        ],
        [
          729.2345,
          589.905
        ]
      ]
    },
    {
      "id": "fitness-decorative",
      "label": "130 fitness inset \u00b7 Tectum finish required",
      "quantity": 211.52249999999998,
      "unit": "SF",
      "color": "#299bba",
      "basis": "2x4 decorative hatch (cross-reference A3.2 legend). Height: 9 feet 6 inches shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity. A3.6 blue review note requires Tectum finish per prototype and manufacturer installation guidance; thickness, backing, suspension and exact product remain unresolved.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            1108.7345,
            681.405
          ],
          [
            1287.2345,
            681.405
          ],
          [
            1287.2345,
            799.905
          ],
          [
            1108.7345,
            799.905
          ]
        ]
      ]
    },
    {
      "id": "fitness-gb",
      "label": "130 fitness surrounding ceiling",
      "quantity": 519.48,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: 9 feet 3 inches shown. Approximate clear horizontal trace; Decorative inset excluded. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            1054.7345,
            556.905
          ],
          [
            1168.7345,
            556.905
          ],
          [
            1168.7345,
            627.405
          ],
          [
            1338.2345,
            627.405
          ],
          [
            1338.2345,
            856.905
          ],
          [
            1054.7345,
            856.905
          ]
        ],
        [
          [
            1108.7345,
            681.405
          ],
          [
            1287.2345,
            681.405
          ],
          [
            1287.2345,
            799.905
          ],
          [
            1108.7345,
            799.905
          ]
        ]
      ]
    },
    {
      "id": "fitness-inset-edge",
      "label": "Fitness inset ceiling perimeter",
      "quantity": 59.4,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Interface only;3-inch height difference shown, edge trim/detail not provided. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "line": [
        [
          1108.7345,
          681.405
        ],
        [
          1287.2345,
          681.405
        ],
        [
          1287.2345,
          799.905
        ],
        [
          1108.7345,
          799.905
        ],
        [
          1108.7345,
          681.405
        ]
      ]
    },
    {
      "id": "fitness-step-face",
      "label": "Fitness inset step-face allowance",
      "quantity": 14.85,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Geometric perimeter \u00d73-inch difference. ALLOWANCE only until vertical edge/profile is confirmed. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "line": [
        [
          1108.7345,
          681.405
        ],
        [
          1287.2345,
          681.405
        ],
        [
          1287.2345,
          799.905
        ],
        [
          1108.7345,
          799.905
        ],
        [
          1108.7345,
          681.405
        ]
      ]
    },
    {
      "id": "registration-canopy",
      "label": "Registration desk533 ceiling feature",
      "quantity": 117.17999999999998,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Dense grid feature; construction/material unresolved. Height: Height not tagged. Approximate clear horizontal trace; Do not assume ordinary tile grid from this feature pattern. Coordination with desk/millwork and feature section required. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            922.7345,
            366.405
          ],
          [
            1048.7345,
            366.405
          ],
          [
            1048.7345,
            459.405
          ],
          [
            922.7345,
            459.405
          ]
        ]
      ]
    },
    {
      "id": "registration-width",
      "label": "Registration feature printed width reference",
      "quantity": 12.149999999999999,
      "unit": "LF",
      "color": "#b06bad",
      "basis": "Source dimension12 feet2-1/2 inches is controlling; line trace approximate. Depth, suspension and feature height unresolved. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "line": [
        [
          924.2345,
          480.405
        ],
        [
          1045.7345,
          480.405
        ]
      ]
    },
    {
      "id": "market",
      "label": "129 market ceiling field",
      "quantity": 63.31499999999999,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: Not individually height-tagged. Approximate clear horizontal trace; Unique source zone; reconcile with existing floor/room takeoffs, not additive floor area. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            780.2345,
            382.905
          ],
          [
            880.7345,
            382.905
          ],
          [
            880.7345,
            445.905
          ],
          [
            780.2345,
            445.905
          ]
        ]
      ]
    },
    {
      "id": "market-soffit",
      "label": "Market west lower strip",
      "quantity": 20.272499999999997,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Painted gypsum board. Height: 7 feet shown. Approximate clear horizontal trace; Unique source zone; reconcile with existing floor/room takeoffs, not additive floor area. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            751.7345,
            366.405
          ],
          [
            777.2345,
            366.405
          ],
          [
            777.2345,
            445.905
          ],
          [
            751.7345,
            445.905
          ]
        ]
      ]
    },
    {
      "id": "work-soffit",
      "label": "Workstation lower strip",
      "quantity": 10.147499999999999,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum board. Height: 7 feet shown. Approximate clear horizontal trace; Unique source zone; reconcile with existing floor/room takeoffs, not additive floor area. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            795.2345,
            366.405
          ],
          [
            856.7345,
            366.405
          ],
          [
            856.7345,
            382.905
          ],
          [
            795.2345,
            382.905
          ]
        ]
      ]
    },
    {
      "id": "public-cross",
      "label": "Public cross-circulation strip",
      "quantity": 278.775,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: Local lower portion9 feet6 inches; remainder untagged. Approximate clear horizontal trace; Unique source zone; reconcile with existing floor/room takeoffs, not additive floor area. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            549.2345,
            454.905
          ],
          [
            1168.7345,
            454.905
          ],
          [
            1168.7345,
            499.905
          ],
          [
            549.2345,
            499.905
          ]
        ]
      ]
    },
    {
      "id": "east-lobby",
      "label": "East public circulation",
      "quantity": 331.55999999999995,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: Local height not shown. Approximate clear horizontal trace; Unique source zone; reconcile with existing floor/room takeoffs, not additive floor area. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            1093.7345,
            186.40499999999997
          ],
          [
            1165.7345,
            186.40499999999997
          ],
          [
            1165.7345,
            549.405
          ],
          [
            1054.7345,
            549.405
          ],
          [
            1054.7345,
            369.405
          ],
          [
            1093.7345,
            369.405
          ]
        ]
      ]
    },
    {
      "id": "vestibule",
      "label": "126 vestibule",
      "quantity": 59.39999999999999,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: 8 feet10 inches shown. Approximate clear horizontal trace; Unique source zone; reconcile with existing floor/room takeoffs, not additive floor area. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            952.7345,
            784.905
          ],
          [
            1042.7345,
            784.905
          ],
          [
            1042.7345,
            850.905
          ],
          [
            952.7345,
            850.905
          ]
        ]
      ]
    },
    {
      "id": "mechanical128",
      "label": "128 mechanical",
      "quantity": 15.839999999999998,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Unhatched / unresolved. Height: Height not tagged. Approximate clear horizontal trace; Unique source zone; reconcile with existing floor/room takeoffs, not additive floor area. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            922.7345,
            784.905
          ],
          [
            946.7345,
            784.905
          ],
          [
            946.7345,
            850.905
          ],
          [
            922.7345,
            850.905
          ]
        ]
      ]
    },
    {
      "id": "mechanical134",
      "label": "134 mechanical",
      "quantity": 39.15,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: 9 feet3 inches shown. Approximate clear horizontal trace; Unique source zone; reconcile with existing floor/room takeoffs, not additive floor area. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.1 independently checked against current source. Geometry remains approximate. ENLARGED REPEAT of first-floor asset; replaces/refines parent trace, never adds another floor quantity.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            1294.7345,
            529.905
          ],
          [
            1338.2345,
            529.905
          ],
          [
            1338.2345,
            619.905
          ],
          [
            1294.7345,
            619.905
          ]
        ]
      ]
    },
    {
      "id": "west-cross",
      "label": "BOH / guest-wing cross corridor",
      "quantity": 156.4,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Actual enlarged clear corridor; painted gypsum hatch. Local height not tagged. Same first-floor corridor, not additional area.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            166,
            453
          ],
          [
            506,
            453
          ],
          [
            506,
            499
          ],
          [
            166,
            499
          ]
        ]
      ]
    },
    {
      "id": "west-public-hall",
      "label": "West lobby / public-room circulation",
      "quantity": 203.55,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Painted gypsum hatch; gross circulation reference before door/recess deductions. Height not locally tagged; same first-floor area.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            523,
            506
          ],
          [
            582,
            506
          ],
          [
            582,
            851
          ],
          [
            523,
            851
          ]
        ]
      ]
    },
    {
      "id": "stair001-ref",
      "label": "001 stair footprint \u00b7 reference only",
      "quantity": 142.4,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "REF footprint only; no finished ceiling or height assumed. Roof/stair sections and structure must resolve actual construction.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            1257,
            226
          ],
          [
            1337,
            226
          ],
          [
            1337,
            404
          ],
          [
            1257,
            404
          ]
        ]
      ]
    },
    {
      "id": "elevator003-ref",
      "label": "003 elevator shaft footprint \u00b7 reference only",
      "quantity": 117.48,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "REF shaft footprint only, not a suspended ceiling quantity; coordinate structure/shaft overhead with elevator design.",
      "sourceSheet": "A3.6",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            1182,
            226
          ],
          [
            1248,
            226
          ],
          [
            1248,
            404
          ],
          [
            1182,
            404
          ]
        ]
      ]
    }
  ]
}