  "sheet": "A3.5",
  "coordinateSpace": {
    "width": 1920,
    "height": 1280
  },
  "calibration": {
    "pixelsPerFoot": 6.666666666666667,
    "printedScale": "1/8 inch = 1 foot",
    "checks": [
      {
        "view": "Printed scale",
        "pixelsPerFoot": 6.666666666666667,
        "basis": "1/8 inch =1 foot"
      },
      {
        "view": "Shared grid6\u20137 vs dimensioned A2.16",
        "sourcePixels": 84.528,
        "referenceFeet": 12.666666666666666
      },
      {
        "view": "Shared grid14\u201315 vs dimensioned A2.16",
        "sourcePixels": 111.22,
        "referenceFeet": 16.666666666666668
      }
    ]
  },
  "rows": [
    {
      "id": "room-501-main",
      "label": "501 king studio main ceiling",
      "quantity": 231.65999999999997,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            293.344,
            550.457
          ],
          [
            371.344,
            550.457
          ],
          [
            371.344,
            682.457
          ],
          [
            293.344,
            682.457
          ]
        ]
      ]
    },
    {
      "id": "room-501-service",
      "label": "501 entry / bath ceiling band",
      "quantity": 98.27999999999999,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            293.344,
            686.457
          ],
          [
            371.344,
            686.457
          ],
          [
            371.344,
            742.457
          ],
          [
            293.344,
            742.457
          ]
        ]
      ]
    },
    {
      "id": "room-503-main",
      "label": "503 king studio main ceiling",
      "quantity": 225.71999999999932,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            379.344,
            550.457
          ],
          [
            455.344,
            550.457
          ],
          [
            455.344,
            682.457
          ],
          [
            379.344,
            682.457
          ]
        ]
      ]
    },
    {
      "id": "room-503-service",
      "label": "503 entry / bath ceiling band",
      "quantity": 95.76000000000064,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            379.344,
            686.457
          ],
          [
            455.344,
            686.457
          ],
          [
            455.344,
            742.457
          ],
          [
            379.344,
            742.457
          ]
        ]
      ]
    },
    {
      "id": "room-505-main",
      "label": "505 connecting king studio main ceiling",
      "quantity": 234.6299999999993,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            464.344,
            550.457
          ],
          [
            543.3439999999999,
            550.457
          ],
          [
            543.3439999999999,
            682.457
          ],
          [
            464.344,
            682.457
          ]
        ]
      ]
    },
    {
      "id": "room-505-service",
      "label": "505 entry / bath ceiling band",
      "quantity": 99.53999999999999,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            464.344,
            686.457
          ],
          [
            543.3439999999999,
            686.457
          ],
          [
            543.3439999999999,
            742.457
          ],
          [
            464.344,
            742.457
          ]
        ]
      ]
    },
    {
      "id": "room-509-main",
      "label": "509 king studio main ceiling",
      "quantity": 222.74999999999997,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            719.3439999999999,
            550.457
          ],
          [
            794.3439999999999,
            550.457
          ],
          [
            794.3439999999999,
            682.457
          ],
          [
            719.3439999999999,
            682.457
          ]
        ]
      ]
    },
    {
      "id": "room-509-service",
      "label": "509 entry / bath ceiling band",
      "quantity": 94.49999999999999,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            719.3439999999999,
            686.457
          ],
          [
            794.3439999999999,
            686.457
          ],
          [
            794.3439999999999,
            742.457
          ],
          [
            719.3439999999999,
            742.457
          ]
        ]
      ]
    },
    {
      "id": "room-511-main",
      "label": "511 king studio main ceiling",
      "quantity": 228.69000000000128,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            802.3439999999999,
            550.457
          ],
          [
            879.3439999999999,
            550.457
          ],
          [
            879.3439999999999,
            682.457
          ],
          [
            802.3439999999999,
            682.457
          ]
        ]
      ]
    },
    {
      "id": "room-511-service",
      "label": "511 entry / bath ceiling band",
      "quantity": 97.01999999999998,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            802.3439999999999,
            686.457
          ],
          [
            879.3439999999999,
            686.457
          ],
          [
            879.3439999999999,
            742.457
          ],
          [
            802.3439999999999,
            742.457
          ]
        ]
      ]
    },
    {
      "id": "room-513-main",
      "label": "513 king studio main ceiling",
      "quantity": 225.71999999999997,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            887.3439999999999,
            550.457
          ],
          [
            963.3439999999999,
            550.457
          ],
          [
            963.3439999999999,
            682.457
          ],
          [
            887.3439999999999,
            682.457
          ]
        ]
      ]
    },
    {
      "id": "room-513-service",
      "label": "513 entry / bath ceiling band",
      "quantity": 95.75999999999999,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            887.3439999999999,
            686.457
          ],
          [
            963.3439999999999,
            686.457
          ],
          [
            963.3439999999999,
            742.457
          ],
          [
            887.3439999999999,
            742.457
          ]
        ]
      ]
    },
    {
      "id": "room-515-main",
      "label": "515 king studio main ceiling",
      "quantity": 225.71999999999997,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            972.3439999999999,
            550.457
          ],
          [
            1048.344,
            550.457
          ],
          [
            1048.344,
            682.457
          ],
          [
            972.3439999999999,
            682.457
          ]
        ]
      ]
    },
    {
      "id": "room-515-service",
      "label": "515 entry / bath ceiling band",
      "quantity": 95.75999999999736,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            972.3439999999999,
            686.457
          ],
          [
            1048.344,
            686.457
          ],
          [
            1048.344,
            742.457
          ],
          [
            972.3439999999999,
            742.457
          ]
        ]
      ]
    },
    {
      "id": "room-517-main",
      "label": "517 king studio main ceiling",
      "quantity": 225.71999999999997,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            1056.344,
            550.457
          ],
          [
            1132.344,
            550.457
          ],
          [
            1132.344,
            682.457
          ],
          [
            1056.344,
            682.457
          ]
        ]
      ]
    },
    {
      "id": "room-517-service",
      "label": "517 entry / bath ceiling band",
      "quantity": 95.75999999999999,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            1056.344,
            686.457
          ],
          [
            1132.344,
            686.457
          ],
          [
            1132.344,
            742.457
          ],
          [
            1056.344,
            742.457
          ]
        ]
      ]
    },
    {
      "id": "room-519-main",
      "label": "519 king studio main ceiling",
      "quantity": 225.71999999999997,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            1141.344,
            550.457
          ],
          [
            1217.344,
            550.457
          ],
          [
            1217.344,
            682.457
          ],
          [
            1141.344,
            682.457
          ]
        ]
      ]
    },
    {
      "id": "room-519-service",
      "label": "519 entry / bath ceiling band",
      "quantity": 95.75999999999999,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            1141.344,
            686.457
          ],
          [
            1217.344,
            686.457
          ],
          [
            1217.344,
            742.457
          ],
          [
            1141.344,
            742.457
          ]
        ]
      ]
    },
    {
      "id": "room-521-main",
      "label": "521 king studio main ceiling",
      "quantity": 228.69000000000258,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            1225.344,
            550.457
          ],
          [
            1302.344,
            550.457
          ],
          [
            1302.344,
            682.457
          ],
          [
            1225.344,
            682.457
          ]
        ]
      ]
    },
    {
      "id": "room-521-service",
      "label": "521 entry / bath ceiling band",
      "quantity": 97.01999999999998,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            1225.344,
            686.457
          ],
          [
            1302.344,
            686.457
          ],
          [
            1302.344,
            742.457
          ],
          [
            1225.344,
            742.457
          ]
        ]
      ]
    },
    {
      "id": "room-504-main",
      "label": "504 king studio main ceiling",
      "quantity": 226.39499999999998,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into fifth-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            465.344,
            844.457
          ],
          [
            543.3439999999999,
            844.457
          ],
          [
            543.3439999999999,
            973.457
          ],
          [
            465.344,
            973.457
          ]
        ]
      ]
    },
    {
      "id": "room-504-service",
      "label": "504 entry / bath ceiling band",
      "quantity": 98.2800000000013,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            465.344,
            783.457
          ],
          [
            543.3439999999999,
            783.457
          ],
          [
            543.3439999999999,
            839.457
          ],
          [
            465.344,
            839.457
          ]
        ]
      ]
    },
    {
      "id": "room-506-main",
      "label": "506 king studio main ceiling",
      "quantity": 223.49249999999998,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into fifth-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            550.3439999999999,
            844.457
          ],
          [
            627.3439999999999,
            844.457
          ],
          [
            627.3439999999999,
            973.457
          ],
          [
            550.3439999999999,
            973.457
          ]
        ]
      ]
    },
    {
      "id": "room-506-service",
      "label": "506 entry / bath ceiling band",
      "quantity": 97.01999999999998,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            550.3439999999999,
            783.457
          ],
          [
            627.3439999999999,
            783.457
          ],
          [
            627.3439999999999,
            839.457
          ],
          [
            550.3439999999999,
            839.457
          ]
        ]
      ]
    },
    {
      "id": "room-508-main",
      "label": "508 king studio main ceiling",
      "quantity": 214.7850000000039,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into fifth-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            636.3439999999999,
            844.457
          ],
          [
            710.3439999999999,
            844.457
          ],
          [
            710.3439999999999,
            973.457
          ],
          [
            636.3439999999999,
            973.457
          ]
        ]
      ]
    },
    {
      "id": "room-508-service",
      "label": "508 entry / bath ceiling band",
      "quantity": 93.23999999999867,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            636.3439999999999,
            783.457
          ],
          [
            710.3439999999999,
            783.457
          ],
          [
            710.3439999999999,
            839.457
          ],
          [
            636.3439999999999,
            839.457
          ]
        ]
      ]
    },
    {
      "id": "room-510-main",
      "label": "510 king studio main ceiling",
      "quantity": 217.68749999999997,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into fifth-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            719.3439999999999,
            844.457
          ],
          [
            794.3439999999999,
            844.457
          ],
          [
            794.3439999999999,
            973.457
          ],
          [
            719.3439999999999,
            973.457
          ]
        ]
      ]
    },
    {
      "id": "room-510-service",
      "label": "510 entry / bath ceiling band",
      "quantity": 94.49999999999999,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            719.3439999999999,
            783.457
          ],
          [
            794.3439999999999,
            783.457
          ],
          [
            794.3439999999999,
            839.457
          ],
          [
            719.3439999999999,
            839.457
          ]
        ]
      ]
    },
    {
      "id": "room-512-main",
      "label": "512 connecting king studio main ceiling",
      "quantity": 223.49249999999998,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into fifth-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            802.3439999999999,
            844.457
          ],
          [
            879.3439999999999,
            844.457
          ],
          [
            879.3439999999999,
            973.457
          ],
          [
            802.3439999999999,
            973.457
          ]
        ]
      ]
    },
    {
      "id": "room-512-service",
      "label": "512 entry / bath ceiling band",
      "quantity": 97.01999999999737,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            802.3439999999999,
            783.457
          ],
          [
            879.3439999999999,
            783.457
          ],
          [
            879.3439999999999,
            839.457
          ],
          [
            802.3439999999999,
            839.457
          ]
        ]
      ]
    },
    {
      "id": "room-514-main",
      "label": "514 connecting king studio main ceiling",
      "quantity": 220.58999999999997,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into fifth-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            887.3439999999999,
            844.457
          ],
          [
            963.3439999999999,
            844.457
          ],
          [
            963.3439999999999,
            973.457
          ],
          [
            887.3439999999999,
            973.457
          ]
        ]
      ]
    },
    {
      "id": "room-514-service",
      "label": "514 entry / bath ceiling band",
      "quantity": 95.75999999999999,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            887.3439999999999,
            783.457
          ],
          [
            963.3439999999999,
            783.457
          ],
          [
            963.3439999999999,
            839.457
          ],
          [
            887.3439999999999,
            839.457
          ]
        ]
      ]
    },
    {
      "id": "room-516-main",
      "label": "516 queen queen main ceiling",
      "quantity": 292.4100000000026,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into fifth-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            972.3439999999999,
            844.457
          ],
          [
            1048.344,
            844.457
          ],
          [
            1048.344,
            1015.457
          ],
          [
            972.3439999999999,
            1015.457
          ]
        ]
      ]
    },
    {
      "id": "room-516-service",
      "label": "516 entry / bath ceiling band",
      "quantity": 95.75999999999999,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            972.3439999999999,
            783.457
          ],
          [
            1048.344,
            783.457
          ],
          [
            1048.344,
            839.457
          ],
          [
            972.3439999999999,
            839.457
          ]
        ]
      ]
    },
    {
      "id": "room-518-main",
      "label": "518 queen queen main ceiling",
      "quantity": 288.5624999999973,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into fifth-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            1057.344,
            844.457
          ],
          [
            1132.344,
            844.457
          ],
          [
            1132.344,
            1015.457
          ],
          [
            1057.344,
            1015.457
          ]
        ]
      ]
    },
    {
      "id": "room-518-service",
      "label": "518 entry / bath ceiling band",
      "quantity": 94.49999999999999,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            1057.344,
            783.457
          ],
          [
            1132.344,
            783.457
          ],
          [
            1132.344,
            839.457
          ],
          [
            1057.344,
            839.457
          ]
        ]
      ]
    },
    {
      "id": "room-520-main",
      "label": "520 queen queen main ceiling",
      "quantity": 292.40999999999997,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into fifth-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            1141.344,
            844.457
          ],
          [
            1217.344,
            844.457
          ],
          [
            1217.344,
            1015.457
          ],
          [
            1141.344,
            1015.457
          ]
        ]
      ]
    },
    {
      "id": "room-520-service",
      "label": "520 entry / bath ceiling band",
      "quantity": 95.75999999999999,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            1141.344,
            783.457
          ],
          [
            1217.344,
            783.457
          ],
          [
            1217.344,
            839.457
          ],
          [
            1141.344,
            839.457
          ]
        ]
      ]
    },
    {
      "id": "room-522-main",
      "label": "522 queen queen main ceiling",
      "quantity": 296.2574999999947,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into fifth-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            1225.344,
            844.457
          ],
          [
            1302.344,
            844.457
          ],
          [
            1302.344,
            1015.457
          ],
          [
            1225.344,
            1015.457
          ]
        ]
      ]
    },
    {
      "id": "room-522-service",
      "label": "522 entry / bath ceiling band",
      "quantity": 97.01999999999998,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            1225.344,
            783.457
          ],
          [
            1302.344,
            783.457
          ],
          [
            1302.344,
            839.457
          ],
          [
            1225.344,
            839.457
          ]
        ]
      ]
    },
    {
      "id": "room-524-main",
      "label": "524 connecting queen queen main ceiling",
      "quantity": 300.10499999999996,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into fifth-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            1310.344,
            844.457
          ],
          [
            1388.344,
            844.457
          ],
          [
            1388.344,
            1015.457
          ],
          [
            1310.344,
            1015.457
          ]
        ]
      ]
    },
    {
      "id": "room-524-service",
      "label": "524 entry / bath ceiling band",
      "quantity": 98.27999999999999,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            1310.344,
            783.457
          ],
          [
            1388.344,
            783.457
          ],
          [
            1388.344,
            839.457
          ],
          [
            1310.344,
            839.457
          ]
        ]
      ]
    },
    {
      "id": "room-526-main",
      "label": "526 accessible king main ceiling",
      "quantity": 392.44499999999994,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into fifth-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            1396.344,
            844.457
          ],
          [
            1498.344,
            844.457
          ],
          [
            1498.344,
            1015.457
          ],
          [
            1396.344,
            1015.457
          ]
        ]
      ]
    },
    {
      "id": "room-526-service",
      "label": "526 entry / bath ceiling band",
      "quantity": 128.5200000000026,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            1396.344,
            783.457
          ],
          [
            1498.344,
            783.457
          ],
          [
            1498.344,
            839.457
          ],
          [
            1396.344,
            839.457
          ]
        ]
      ]
    },
    {
      "id": "room-507-main-west",
      "label": "507 accessible one-bedroom \u00b7 west main ceiling",
      "quantity": 165.86999999999998,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Same suite, distinct ceiling field. Missing east height on A3.5 retained. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            551.3439999999999,
            585.457
          ],
          [
            627.3439999999999,
            585.457
          ],
          [
            627.3439999999999,
            682.457
          ],
          [
            551.3439999999999,
            682.457
          ]
        ]
      ]
    },
    {
      "id": "room-507-main-east",
      "label": "507 accessible one-bedroom \u00b7 east main ceiling",
      "quantity": 165.86999999999998,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Painted gypsum-board hatch. Height: NOT TAGGED on A3.5. Approximate clear horizontal trace; Same suite, distinct ceiling field. Missing east height on A3.5 retained. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            634.3439999999999,
            585.457
          ],
          [
            710.3439999999999,
            585.457
          ],
          [
            710.3439999999999,
            682.457
          ],
          [
            634.3439999999999,
            682.457
          ]
        ]
      ]
    },
    {
      "id": "room-507-service",
      "label": "507 combined service ceiling band",
      "quantity": 200.33999999999997,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: Local height untagged. Approximate clear horizontal trace; Gross service band before interior wall/boxed-service deductions. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            551.3439999999999,
            686.457
          ],
          [
            710.3439999999999,
            686.457
          ],
          [
            710.3439999999999,
            742.457
          ],
          [
            551.3439999999999,
            742.457
          ]
        ]
      ]
    },
    {
      "id": "room-502-main-west",
      "label": "502 one-bedroom west main ceiling",
      "quantity": 142.06499999999932,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            294.344,
            891.457
          ],
          [
            371.344,
            891.457
          ],
          [
            371.344,
            973.457
          ],
          [
            294.344,
            973.457
          ]
        ]
      ]
    },
    {
      "id": "room-502-main-east",
      "label": "502 one-bedroom east main ceiling",
      "quantity": 226.79999999999998,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            379.344,
            847.457
          ],
          [
            459.344,
            847.457
          ],
          [
            459.344,
            973.457
          ],
          [
            379.344,
            973.457
          ]
        ]
      ]
    },
    {
      "id": "room-502-service",
      "label": "502 service ceiling around stair",
      "quantity": 128.92500000000064,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: Local height untagged. Approximate clear horizontal trace; Stair footprint excluded; service partitions still require detail tracing. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            294.344,
            846.457
          ],
          [
            414.344,
            846.457
          ],
          [
            414.344,
            784.457
          ],
          [
            459.344,
            784.457
          ],
          [
            459.344,
            842.457
          ],
          [
            374.344,
            842.457
          ],
          [
            374.344,
            887.457
          ],
          [
            294.344,
            887.457
          ]
        ]
      ]
    },
    {
      "id": "corridor",
      "label": "533 corridor ceiling",
      "quantity": 820.6199999999999,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main strip plus east return. Reconcile corridor device symbols with electrical/fire protection. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            294.344,
            749.457
          ],
          [
            1372.344,
            749.457
          ],
          [
            1372.344,
            718.457
          ],
          [
            1499.344,
            718.457
          ],
          [
            1499.344,
            776.457
          ],
          [
            294.344,
            776.457
          ]
        ]
      ]
    },
    {
      "id": "corridor-boundary",
      "label": "Corridor gross ceiling boundary",
      "quantity": 378.9,
      "unit": "LF",
      "color": "#398d79",
      "basis": "Clear perimeter including doorway interruptions; not net edge trim or construction wall LF. Deduct openings before perimeter takeoff. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "line": [
        [
          294.344,
          749.457
        ],
        [
          1372.344,
          749.457
        ],
        [
          1372.344,
          718.457
        ],
        [
          1499.344,
          718.457
        ],
        [
          1499.344,
          776.457
        ],
        [
          294.344,
          776.457
        ],
        [
          294.344,
          749.457
        ]
      ]
    },
    {
      "id": "elevator-lobby",
      "label": "Elevator lobby 500",
      "quantity": 215.95499999999998,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: 7 feet 6 inches shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            1310.344,
            605.457
          ],
          [
            1388.344,
            605.457
          ],
          [
            1388.344,
            715.457
          ],
          [
            1372.344,
            715.457
          ],
          [
            1372.344,
            742.457
          ],
          [
            1326.344,
            742.457
          ],
          [
            1326.344,
            701.457
          ],
          [
            1310.344,
            701.457
          ]
        ]
      ]
    },
    {
      "id": "storage",
      "label": "523 storage",
      "quantity": 56.54249999999999,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Unhatched / material unresolved. Height: Height not shown. Approximate clear horizontal trace; Do not assign legend default or a floor finish as ceiling material. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate. Fifth-floor northern storage notch included from current source.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            1310,
            550
          ],
          [
            1329,
            550
          ],
          [
            1329,
            570
          ],
          [
            1389,
            570
          ],
          [
            1389,
            597
          ],
          [
            1310,
            597
          ]
        ]
      ]
    },
    {
      "id": "stair-west",
      "label": "Stair West reference footprint",
      "quantity": 136.89,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "NO finished-ceiling assumption. Height: Height / soffit extent not shown. Approximate clear horizontal trace; Reference only; excludes shaft/stair void from finished-ceiling totals. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            294.344,
            786.457
          ],
          [
            411.344,
            786.457
          ],
          [
            411.344,
            838.457
          ],
          [
            294.344,
            838.457
          ]
        ]
      ]
    },
    {
      "id": "stair-east",
      "label": "Stair East reference footprint",
      "quantity": 137.3625000000026,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "NO finished-ceiling assumption. Height: Height / soffit extent not shown. Approximate clear horizontal trace; Reference only; excludes shaft/stair void from finished-ceiling totals. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            1443.344,
            599.457
          ],
          [
            1498.344,
            599.457
          ],
          [
            1498.344,
            710.457
          ],
          [
            1443.344,
            710.457
          ]
        ]
      ]
    },
    {
      "id": "elevator-shaft",
      "label": "Elevator Shaft reference footprint",
      "quantity": 104.89499999999998,
      "unit": "SF",
      "color": "#299bba",
      "basis": "NO finished-ceiling assumption. Height: Height / soffit extent not shown. Approximate clear horizontal trace; Reference only; excludes shaft/stair void from finished-ceiling totals. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.5",
      "parentSheet": "Floor 5",
      "polygons": [
        [
          [
            1396.344,
            599.457
          ],
          [
            1438.344,
            599.457
          ],
          [
            1438.344,
            710.457
          ],
          [
            1396.344,
            710.457
          ]
        ]
      ]
    }
  ]
}