  "sheet": "A3.4",
  "coordinateSpace": {
    "width": 1920,
    "height": 1280
  },
  "calibration": {
    "pixelsPerFoot": 6.666666666666667,
    "printedScale": "1/8 inch = 1 foot",
    "checks": [
      {
        "view": "Printed scale",
        "pixelsPerFoot": 6.666666666666667,
        "basis": "1/8 inch =1 foot"
      },
      {
        "view": "Shared grid6\u20137 vs dimensioned A2.16",
        "sourcePixels": 84.528,
        "referenceFeet": 12.666666666666666
      },
      {
        "view": "Shared grid14\u201315 vs dimensioned A2.16",
        "sourcePixels": 111.22,
        "referenceFeet": 16.666666666666668
      }
    ]
  },
  "rows": [
    {
      "id": "room-401-main",
      "label": "401 king studio main ceiling",
      "quantity": 231.65999999999997,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            292.209,
            473.384
          ],
          [
            370.209,
            473.384
          ],
          [
            370.209,
            605.384
          ],
          [
            292.209,
            605.384
          ]
        ]
      ]
    },
    {
      "id": "room-401-service",
      "label": "401 entry / bath ceiling band",
      "quantity": 98.27999999999999,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            292.209,
            609.384
          ],
          [
            370.209,
            609.384
          ],
          [
            370.209,
            665.384
          ],
          [
            292.209,
            665.384
          ]
        ]
      ]
    },
    {
      "id": "room-403-main",
      "label": "403 king studio main ceiling",
      "quantity": 225.71999999999932,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            378.209,
            473.384
          ],
          [
            454.209,
            473.384
          ],
          [
            454.209,
            605.384
          ],
          [
            378.209,
            605.384
          ]
        ]
      ]
    },
    {
      "id": "room-403-service",
      "label": "403 entry / bath ceiling band",
      "quantity": 95.76000000000064,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            378.209,
            609.384
          ],
          [
            454.209,
            609.384
          ],
          [
            454.209,
            665.384
          ],
          [
            378.209,
            665.384
          ]
        ]
      ]
    },
    {
      "id": "room-405-main",
      "label": "405 connecting king studio main ceiling",
      "quantity": 234.6299999999993,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            463.209,
            473.384
          ],
          [
            542.209,
            473.384
          ],
          [
            542.209,
            605.384
          ],
          [
            463.209,
            605.384
          ]
        ]
      ]
    },
    {
      "id": "room-405-service",
      "label": "405 entry / bath ceiling band",
      "quantity": 99.53999999999999,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            463.209,
            609.384
          ],
          [
            542.209,
            609.384
          ],
          [
            542.209,
            665.384
          ],
          [
            463.209,
            665.384
          ]
        ]
      ]
    },
    {
      "id": "room-409-main",
      "label": "409 king studio main ceiling",
      "quantity": 222.74999999999997,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            718.209,
            473.384
          ],
          [
            793.209,
            473.384
          ],
          [
            793.209,
            605.384
          ],
          [
            718.209,
            605.384
          ]
        ]
      ]
    },
    {
      "id": "room-409-service",
      "label": "409 entry / bath ceiling band",
      "quantity": 94.49999999999999,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            718.209,
            609.384
          ],
          [
            793.209,
            609.384
          ],
          [
            793.209,
            665.384
          ],
          [
            718.209,
            665.384
          ]
        ]
      ]
    },
    {
      "id": "room-411-main",
      "label": "411 king studio main ceiling",
      "quantity": 228.69000000000128,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            801.209,
            473.384
          ],
          [
            878.209,
            473.384
          ],
          [
            878.209,
            605.384
          ],
          [
            801.209,
            605.384
          ]
        ]
      ]
    },
    {
      "id": "room-411-service",
      "label": "411 entry / bath ceiling band",
      "quantity": 97.01999999999998,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            801.209,
            609.384
          ],
          [
            878.209,
            609.384
          ],
          [
            878.209,
            665.384
          ],
          [
            801.209,
            665.384
          ]
        ]
      ]
    },
    {
      "id": "room-413-main",
      "label": "413 king studio main ceiling",
      "quantity": 225.71999999999997,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            886.209,
            473.384
          ],
          [
            962.209,
            473.384
          ],
          [
            962.209,
            605.384
          ],
          [
            886.209,
            605.384
          ]
        ]
      ]
    },
    {
      "id": "room-413-service",
      "label": "413 entry / bath ceiling band",
      "quantity": 95.75999999999999,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            886.209,
            609.384
          ],
          [
            962.209,
            609.384
          ],
          [
            962.209,
            665.384
          ],
          [
            886.209,
            665.384
          ]
        ]
      ]
    },
    {
      "id": "room-415-main",
      "label": "415 king studio main ceiling",
      "quantity": 225.71999999999997,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            971.209,
            473.384
          ],
          [
            1047.2089999999998,
            473.384
          ],
          [
            1047.2089999999998,
            605.384
          ],
          [
            971.209,
            605.384
          ]
        ]
      ]
    },
    {
      "id": "room-415-service",
      "label": "415 entry / bath ceiling band",
      "quantity": 95.75999999999736,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            971.209,
            609.384
          ],
          [
            1047.2089999999998,
            609.384
          ],
          [
            1047.2089999999998,
            665.384
          ],
          [
            971.209,
            665.384
          ]
        ]
      ]
    },
    {
      "id": "room-417-main",
      "label": "417 king studio main ceiling",
      "quantity": 225.71999999999997,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            1055.2089999999998,
            473.384
          ],
          [
            1131.2089999999998,
            473.384
          ],
          [
            1131.2089999999998,
            605.384
          ],
          [
            1055.2089999999998,
            605.384
          ]
        ]
      ]
    },
    {
      "id": "room-417-service",
      "label": "417 entry / bath ceiling band",
      "quantity": 95.75999999999999,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            1055.2089999999998,
            609.384
          ],
          [
            1131.2089999999998,
            609.384
          ],
          [
            1131.2089999999998,
            665.384
          ],
          [
            1055.2089999999998,
            665.384
          ]
        ]
      ]
    },
    {
      "id": "room-419-main",
      "label": "419 king studio main ceiling",
      "quantity": 225.71999999999997,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            1140.2089999999998,
            473.384
          ],
          [
            1216.2089999999998,
            473.384
          ],
          [
            1216.2089999999998,
            605.384
          ],
          [
            1140.2089999999998,
            605.384
          ]
        ]
      ]
    },
    {
      "id": "room-419-service",
      "label": "419 entry / bath ceiling band",
      "quantity": 95.75999999999999,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            1140.2089999999998,
            609.384
          ],
          [
            1216.2089999999998,
            609.384
          ],
          [
            1216.2089999999998,
            665.384
          ],
          [
            1140.2089999999998,
            665.384
          ]
        ]
      ]
    },
    {
      "id": "room-421-main",
      "label": "421 king studio main ceiling",
      "quantity": 228.69000000000258,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            1224.2089999999998,
            473.384
          ],
          [
            1301.2089999999998,
            473.384
          ],
          [
            1301.2089999999998,
            605.384
          ],
          [
            1224.2089999999998,
            605.384
          ]
        ]
      ]
    },
    {
      "id": "room-421-service",
      "label": "421 entry / bath ceiling band",
      "quantity": 97.01999999999998,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            1224.2089999999998,
            609.384
          ],
          [
            1301.2089999999998,
            609.384
          ],
          [
            1301.2089999999998,
            665.384
          ],
          [
            1224.2089999999998,
            665.384
          ]
        ]
      ]
    },
    {
      "id": "room-404-main",
      "label": "404 king studio main ceiling",
      "quantity": 226.39499999999998,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into fourth-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            464.209,
            767.384
          ],
          [
            542.209,
            767.384
          ],
          [
            542.209,
            896.384
          ],
          [
            464.209,
            896.384
          ]
        ]
      ]
    },
    {
      "id": "room-404-service",
      "label": "404 entry / bath ceiling band",
      "quantity": 98.2800000000013,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            464.209,
            706.384
          ],
          [
            542.209,
            706.384
          ],
          [
            542.209,
            762.384
          ],
          [
            464.209,
            762.384
          ]
        ]
      ]
    },
    {
      "id": "room-406-main",
      "label": "406 king studio main ceiling",
      "quantity": 223.49249999999998,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into fourth-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            549.209,
            767.384
          ],
          [
            626.209,
            767.384
          ],
          [
            626.209,
            896.384
          ],
          [
            549.209,
            896.384
          ]
        ]
      ]
    },
    {
      "id": "room-406-service",
      "label": "406 entry / bath ceiling band",
      "quantity": 97.01999999999998,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            549.209,
            706.384
          ],
          [
            626.209,
            706.384
          ],
          [
            626.209,
            762.384
          ],
          [
            549.209,
            762.384
          ]
        ]
      ]
    },
    {
      "id": "room-408-main",
      "label": "408 king studio main ceiling",
      "quantity": 214.7850000000039,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into fourth-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            635.209,
            767.384
          ],
          [
            709.209,
            767.384
          ],
          [
            709.209,
            896.384
          ],
          [
            635.209,
            896.384
          ]
        ]
      ]
    },
    {
      "id": "room-408-service",
      "label": "408 entry / bath ceiling band",
      "quantity": 93.23999999999867,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            635.209,
            706.384
          ],
          [
            709.209,
            706.384
          ],
          [
            709.209,
            762.384
          ],
          [
            635.209,
            762.384
          ]
        ]
      ]
    },
    {
      "id": "room-410-main",
      "label": "410 king studio main ceiling",
      "quantity": 217.68749999999997,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into fourth-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            718.209,
            767.384
          ],
          [
            793.209,
            767.384
          ],
          [
            793.209,
            896.384
          ],
          [
            718.209,
            896.384
          ]
        ]
      ]
    },
    {
      "id": "room-410-service",
      "label": "410 entry / bath ceiling band",
      "quantity": 94.49999999999999,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            718.209,
            706.384
          ],
          [
            793.209,
            706.384
          ],
          [
            793.209,
            762.384
          ],
          [
            718.209,
            762.384
          ]
        ]
      ]
    },
    {
      "id": "room-412-main",
      "label": "412 king studio main ceiling",
      "quantity": 223.49249999999998,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into fourth-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            801.209,
            767.384
          ],
          [
            878.209,
            767.384
          ],
          [
            878.209,
            896.384
          ],
          [
            801.209,
            896.384
          ]
        ]
      ]
    },
    {
      "id": "room-412-service",
      "label": "412 entry / bath ceiling band",
      "quantity": 97.01999999999737,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            801.209,
            706.384
          ],
          [
            878.209,
            706.384
          ],
          [
            878.209,
            762.384
          ],
          [
            801.209,
            762.384
          ]
        ]
      ]
    },
    {
      "id": "room-414-main",
      "label": "414 king studio main ceiling",
      "quantity": 220.58999999999997,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into fourth-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            886.209,
            767.384
          ],
          [
            962.209,
            767.384
          ],
          [
            962.209,
            896.384
          ],
          [
            886.209,
            896.384
          ]
        ]
      ]
    },
    {
      "id": "room-414-service",
      "label": "414 entry / bath ceiling band",
      "quantity": 95.75999999999999,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            886.209,
            706.384
          ],
          [
            962.209,
            706.384
          ],
          [
            962.209,
            762.384
          ],
          [
            886.209,
            762.384
          ]
        ]
      ]
    },
    {
      "id": "room-416-main",
      "label": "416 queen queen main ceiling",
      "quantity": 292.4100000000026,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into fourth-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            971.209,
            767.384
          ],
          [
            1047.2089999999998,
            767.384
          ],
          [
            1047.2089999999998,
            938.384
          ],
          [
            971.209,
            938.384
          ]
        ]
      ]
    },
    {
      "id": "room-416-service",
      "label": "416 entry / bath ceiling band",
      "quantity": 95.75999999999999,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            971.209,
            706.384
          ],
          [
            1047.2089999999998,
            706.384
          ],
          [
            1047.2089999999998,
            762.384
          ],
          [
            971.209,
            762.384
          ]
        ]
      ]
    },
    {
      "id": "room-418-main",
      "label": "418 queen queen main ceiling",
      "quantity": 288.5624999999973,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into fourth-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            1056.2089999999998,
            767.384
          ],
          [
            1131.2089999999998,
            767.384
          ],
          [
            1131.2089999999998,
            938.384
          ],
          [
            1056.2089999999998,
            938.384
          ]
        ]
      ]
    },
    {
      "id": "room-418-service",
      "label": "418 entry / bath ceiling band",
      "quantity": 94.49999999999999,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            1056.2089999999998,
            706.384
          ],
          [
            1131.2089999999998,
            706.384
          ],
          [
            1131.2089999999998,
            762.384
          ],
          [
            1056.2089999999998,
            762.384
          ]
        ]
      ]
    },
    {
      "id": "room-420-main",
      "label": "420 queen queen main ceiling",
      "quantity": 292.40999999999997,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into fourth-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            1140.2089999999998,
            767.384
          ],
          [
            1216.2089999999998,
            767.384
          ],
          [
            1216.2089999999998,
            938.384
          ],
          [
            1140.2089999999998,
            938.384
          ]
        ]
      ]
    },
    {
      "id": "room-420-service",
      "label": "420 entry / bath ceiling band",
      "quantity": 95.75999999999999,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            1140.2089999999998,
            706.384
          ],
          [
            1216.2089999999998,
            706.384
          ],
          [
            1216.2089999999998,
            762.384
          ],
          [
            1140.2089999999998,
            762.384
          ]
        ]
      ]
    },
    {
      "id": "room-422-main",
      "label": "422 queen queen main ceiling",
      "quantity": 296.2574999999947,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into fourth-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            1224.2089999999998,
            767.384
          ],
          [
            1301.2089999999998,
            767.384
          ],
          [
            1301.2089999999998,
            938.384
          ],
          [
            1224.2089999999998,
            938.384
          ]
        ]
      ]
    },
    {
      "id": "room-422-service",
      "label": "422 entry / bath ceiling band",
      "quantity": 97.01999999999998,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            1224.2089999999998,
            706.384
          ],
          [
            1301.2089999999998,
            706.384
          ],
          [
            1301.2089999999998,
            762.384
          ],
          [
            1224.2089999999998,
            762.384
          ]
        ]
      ]
    },
    {
      "id": "room-424-main",
      "label": "424 connecting queen queen main ceiling",
      "quantity": 300.10499999999996,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into fourth-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            1309.2089999999998,
            767.384
          ],
          [
            1387.2089999999998,
            767.384
          ],
          [
            1387.2089999999998,
            938.384
          ],
          [
            1309.2089999999998,
            938.384
          ]
        ]
      ]
    },
    {
      "id": "room-424-service",
      "label": "424 entry / bath ceiling band",
      "quantity": 98.27999999999999,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            1309.2089999999998,
            706.384
          ],
          [
            1387.2089999999998,
            706.384
          ],
          [
            1387.2089999999998,
            762.384
          ],
          [
            1309.2089999999998,
            762.384
          ]
        ]
      ]
    },
    {
      "id": "room-426-main",
      "label": "426 accessible king main ceiling",
      "quantity": 392.44499999999994,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into fourth-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            1395.2089999999998,
            767.384
          ],
          [
            1497.2089999999998,
            767.384
          ],
          [
            1497.2089999999998,
            938.384
          ],
          [
            1395.2089999999998,
            938.384
          ]
        ]
      ]
    },
    {
      "id": "room-426-service",
      "label": "426 entry / bath ceiling band",
      "quantity": 128.5200000000026,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            1395.2089999999998,
            706.384
          ],
          [
            1497.2089999999998,
            706.384
          ],
          [
            1497.2089999999998,
            762.384
          ],
          [
            1395.2089999999998,
            762.384
          ]
        ]
      ]
    },
    {
      "id": "room-407-main-west",
      "label": "407 accessible one-bedroom \u00b7 west main ceiling",
      "quantity": 165.86999999999998,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Same suite, distinct ceiling field. Missing east height on A3.4 retained. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            550.209,
            508.384
          ],
          [
            626.209,
            508.384
          ],
          [
            626.209,
            605.384
          ],
          [
            550.209,
            605.384
          ]
        ]
      ]
    },
    {
      "id": "room-407-main-east",
      "label": "407 accessible one-bedroom \u00b7 east main ceiling",
      "quantity": 165.86999999999998,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Painted gypsum-board hatch. Height: NOT TAGGED on A3.4. Approximate clear horizontal trace; Same suite, distinct ceiling field. Missing east height on A3.4 retained. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            633.209,
            508.384
          ],
          [
            709.209,
            508.384
          ],
          [
            709.209,
            605.384
          ],
          [
            633.209,
            605.384
          ]
        ]
      ]
    },
    {
      "id": "room-407-service",
      "label": "407 combined service ceiling band",
      "quantity": 200.33999999999997,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: Local height untagged. Approximate clear horizontal trace; Gross service band before interior wall/boxed-service deductions. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            550.209,
            609.384
          ],
          [
            709.209,
            609.384
          ],
          [
            709.209,
            665.384
          ],
          [
            550.209,
            665.384
          ]
        ]
      ]
    },
    {
      "id": "room-402-main-west",
      "label": "402 one-bedroom west main ceiling",
      "quantity": 142.06499999999932,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            293.209,
            814.384
          ],
          [
            370.209,
            814.384
          ],
          [
            370.209,
            896.384
          ],
          [
            293.209,
            896.384
          ]
        ]
      ]
    },
    {
      "id": "room-402-main-east",
      "label": "402 one-bedroom east main ceiling",
      "quantity": 226.79999999999998,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            378.209,
            770.384
          ],
          [
            458.209,
            770.384
          ],
          [
            458.209,
            896.384
          ],
          [
            378.209,
            896.384
          ]
        ]
      ]
    },
    {
      "id": "room-402-service",
      "label": "402 service ceiling around stair",
      "quantity": 128.92500000000064,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: Local height untagged. Approximate clear horizontal trace; Stair footprint excluded; service partitions still require detail tracing. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            293.209,
            769.384
          ],
          [
            413.209,
            769.384
          ],
          [
            413.209,
            707.384
          ],
          [
            458.209,
            707.384
          ],
          [
            458.209,
            765.384
          ],
          [
            373.209,
            765.384
          ],
          [
            373.209,
            810.384
          ],
          [
            293.209,
            810.384
          ]
        ]
      ]
    },
    {
      "id": "corridor",
      "label": "433 corridor ceiling",
      "quantity": 820.6199999999999,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main strip plus east return. Reconcile corridor device symbols with electrical/fire protection. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            293.209,
            672.384
          ],
          [
            1371.2089999999998,
            672.384
          ],
          [
            1371.2089999999998,
            641.384
          ],
          [
            1498.2089999999998,
            641.384
          ],
          [
            1498.2089999999998,
            699.384
          ],
          [
            293.209,
            699.384
          ]
        ]
      ]
    },
    {
      "id": "corridor-boundary",
      "label": "Corridor gross ceiling boundary",
      "quantity": 378.9,
      "unit": "LF",
      "color": "#398d79",
      "basis": "Clear perimeter including doorway interruptions; not net edge trim or construction wall LF. Deduct openings before perimeter takeoff. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "line": [
        [
          293.209,
          672.384
        ],
        [
          1371.2089999999998,
          672.384
        ],
        [
          1371.2089999999998,
          641.384
        ],
        [
          1498.2089999999998,
          641.384
        ],
        [
          1498.2089999999998,
          699.384
        ],
        [
          293.209,
          699.384
        ],
        [
          293.209,
          672.384
        ]
      ]
    },
    {
      "id": "elevator-lobby",
      "label": "Elevator lobby 400",
      "quantity": 215.95499999999998,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: 7 feet 6 inches shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            1309.2089999999998,
            528.384
          ],
          [
            1387.2089999999998,
            528.384
          ],
          [
            1387.2089999999998,
            638.384
          ],
          [
            1371.2089999999998,
            638.384
          ],
          [
            1371.2089999999998,
            665.384
          ],
          [
            1325.2089999999998,
            665.384
          ],
          [
            1325.2089999999998,
            624.384
          ],
          [
            1309.2089999999998,
            624.384
          ]
        ]
      ]
    },
    {
      "id": "storage",
      "label": "423 storage",
      "quantity": 49.13999999999737,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Unhatched / material unresolved. Height: Height not shown. Approximate clear horizontal trace; Do not assign legend default or a floor finish as ceiling material. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            1309.2089999999998,
            493.384
          ],
          [
            1387.2089999999998,
            493.384
          ],
          [
            1387.2089999999998,
            521.384
          ],
          [
            1309.2089999999998,
            521.384
          ]
        ]
      ]
    },
    {
      "id": "stair-west",
      "label": "Stair West reference footprint",
      "quantity": 136.89,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "NO finished-ceiling assumption. Height: Height / soffit extent not shown. Approximate clear horizontal trace; Reference only; excludes shaft/stair void from finished-ceiling totals. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            293.209,
            709.384
          ],
          [
            410.209,
            709.384
          ],
          [
            410.209,
            761.384
          ],
          [
            293.209,
            761.384
          ]
        ]
      ]
    },
    {
      "id": "stair-east",
      "label": "Stair East reference footprint",
      "quantity": 137.3625000000026,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "NO finished-ceiling assumption. Height: Height / soffit extent not shown. Approximate clear horizontal trace; Reference only; excludes shaft/stair void from finished-ceiling totals. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            1442.2089999999998,
            522.384
          ],
          [
            1497.2089999999998,
            522.384
          ],
          [
            1497.2089999999998,
            633.384
          ],
          [
            1442.2089999999998,
            633.384
          ]
        ]
      ]
    },
    {
      "id": "elevator-shaft",
      "label": "Elevator Shaft reference footprint",
      "quantity": 104.89499999999998,
      "unit": "SF",
      "color": "#299bba",
      "basis": "NO finished-ceiling assumption. Height: Height / soffit extent not shown. Approximate clear horizontal trace; Reference only; excludes shaft/stair void from finished-ceiling totals. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate. Same-scale building-grid registration from A3.3 independently checked against current source. Geometry remains approximate.",
      "sourceSheet": "A3.4",
      "parentSheet": "Floor 4",
      "polygons": [
        [
          [
            1395.2089999999998,
            522.384
          ],
          [
            1437.2089999999998,
            522.384
          ],
          [
            1437.2089999999998,
            633.384
          ],
          [
            1395.2089999999998,
            633.384
          ]
        ]
      ]
    }
  ]
}