  "sheet": "A3.2",
  "coordinateSpace": {
    "width": 1920,
    "height": 1280
  },
  "calibration": {
    "pixelsPerFoot": 6.666666666666667,
    "printedScale": "1/8 inch = 1 foot",
    "checks": [
      {
        "view": "Printed1/8 inch at72 PDF points per inch",
        "pixelsPerFoot": 6.666666666666667,
        "basis": "9 PDF points per foot divided by1.35"
      },
      {
        "view": "Registered grid6\u20137 against A2.16 12-foot8-inch bay",
        "sourcePixels": 84.5,
        "referenceFeet": 12.666666666666666,
        "pixelsPerFoot": 6.671052631578948
      },
      {
        "view": "Registered grid14\u201315 against A2.16 16-foot8-inch bay",
        "sourcePixels": 111.2,
        "referenceFeet": 16.666666666666668,
        "pixelsPerFoot": 6.672
      }
    ]
  },
  "rows": [
    {
      "id": "room-201-main",
      "label": "201 king studio main ceiling",
      "quantity": 231.65999999999997,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            281,
            542
          ],
          [
            359,
            542
          ],
          [
            359,
            674
          ],
          [
            281,
            674
          ]
        ]
      ]
    },
    {
      "id": "room-201-service",
      "label": "201 entry / bath ceiling band",
      "quantity": 98.27999999999999,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            281,
            678
          ],
          [
            359,
            678
          ],
          [
            359,
            734
          ],
          [
            281,
            734
          ]
        ]
      ]
    },
    {
      "id": "room-203-main",
      "label": "203 king studio main ceiling",
      "quantity": 225.71999999999997,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            367,
            542
          ],
          [
            443,
            542
          ],
          [
            443,
            674
          ],
          [
            367,
            674
          ]
        ]
      ]
    },
    {
      "id": "room-203-service",
      "label": "203 entry / bath ceiling band",
      "quantity": 95.75999999999999,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            367,
            678
          ],
          [
            443,
            678
          ],
          [
            443,
            734
          ],
          [
            367,
            734
          ]
        ]
      ]
    },
    {
      "id": "room-205-main",
      "label": "205 connecting king studio main ceiling",
      "quantity": 234.62999999999997,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            452,
            542
          ],
          [
            531,
            542
          ],
          [
            531,
            674
          ],
          [
            452,
            674
          ]
        ]
      ]
    },
    {
      "id": "room-205-service",
      "label": "205 entry / bath ceiling band",
      "quantity": 99.53999999999999,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            452,
            678
          ],
          [
            531,
            678
          ],
          [
            531,
            734
          ],
          [
            452,
            734
          ]
        ]
      ]
    },
    {
      "id": "room-209-main",
      "label": "209 king studio main ceiling",
      "quantity": 222.74999999999997,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            707,
            542
          ],
          [
            782,
            542
          ],
          [
            782,
            674
          ],
          [
            707,
            674
          ]
        ]
      ]
    },
    {
      "id": "room-209-service",
      "label": "209 entry / bath ceiling band",
      "quantity": 94.49999999999999,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            707,
            678
          ],
          [
            782,
            678
          ],
          [
            782,
            734
          ],
          [
            707,
            734
          ]
        ]
      ]
    },
    {
      "id": "room-211-main",
      "label": "211 king studio main ceiling",
      "quantity": 228.68999999999997,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            790,
            542
          ],
          [
            867,
            542
          ],
          [
            867,
            674
          ],
          [
            790,
            674
          ]
        ]
      ]
    },
    {
      "id": "room-211-service",
      "label": "211 entry / bath ceiling band",
      "quantity": 97.01999999999998,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            790,
            678
          ],
          [
            867,
            678
          ],
          [
            867,
            734
          ],
          [
            790,
            734
          ]
        ]
      ]
    },
    {
      "id": "room-213-main",
      "label": "213 king studio main ceiling",
      "quantity": 225.71999999999997,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            875,
            542
          ],
          [
            951,
            542
          ],
          [
            951,
            674
          ],
          [
            875,
            674
          ]
        ]
      ]
    },
    {
      "id": "room-213-service",
      "label": "213 entry / bath ceiling band",
      "quantity": 95.75999999999999,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            875,
            678
          ],
          [
            951,
            678
          ],
          [
            951,
            734
          ],
          [
            875,
            734
          ]
        ]
      ]
    },
    {
      "id": "room-215-main",
      "label": "215 king studio main ceiling",
      "quantity": 225.71999999999997,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            960,
            542
          ],
          [
            1036,
            542
          ],
          [
            1036,
            674
          ],
          [
            960,
            674
          ]
        ]
      ]
    },
    {
      "id": "room-215-service",
      "label": "215 entry / bath ceiling band",
      "quantity": 95.75999999999999,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            960,
            678
          ],
          [
            1036,
            678
          ],
          [
            1036,
            734
          ],
          [
            960,
            734
          ]
        ]
      ]
    },
    {
      "id": "room-217-main",
      "label": "217 king studio main ceiling",
      "quantity": 225.71999999999997,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            1044,
            542
          ],
          [
            1120,
            542
          ],
          [
            1120,
            674
          ],
          [
            1044,
            674
          ]
        ]
      ]
    },
    {
      "id": "room-217-service",
      "label": "217 entry / bath ceiling band",
      "quantity": 95.75999999999999,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            1044,
            678
          ],
          [
            1120,
            678
          ],
          [
            1120,
            734
          ],
          [
            1044,
            734
          ]
        ]
      ]
    },
    {
      "id": "room-219-main",
      "label": "219 king studio main ceiling",
      "quantity": 225.71999999999997,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            1129,
            542
          ],
          [
            1205,
            542
          ],
          [
            1205,
            674
          ],
          [
            1129,
            674
          ]
        ]
      ]
    },
    {
      "id": "room-219-service",
      "label": "219 entry / bath ceiling band",
      "quantity": 95.75999999999999,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            1129,
            678
          ],
          [
            1205,
            678
          ],
          [
            1205,
            734
          ],
          [
            1129,
            734
          ]
        ]
      ]
    },
    {
      "id": "room-221-main",
      "label": "221 king studio main ceiling",
      "quantity": 228.68999999999997,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main room excludes service band; wall-light/background FF&E reconciles type details. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            1213,
            542
          ],
          [
            1290,
            542
          ],
          [
            1290,
            674
          ],
          [
            1213,
            674
          ]
        ]
      ]
    },
    {
      "id": "room-221-service",
      "label": "221 entry / bath ceiling band",
      "quantity": 97.01999999999998,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross combined entry/bath band includes internal partition footprint. Room enlarged details show lower ceilings but require local confirmation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            1213,
            678
          ],
          [
            1290,
            678
          ],
          [
            1290,
            734
          ],
          [
            1213,
            734
          ]
        ]
      ]
    },
    {
      "id": "room-204-main",
      "label": "204 king studio main ceiling",
      "quantity": 226.39499999999998,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into third-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            453,
            836
          ],
          [
            531,
            836
          ],
          [
            531,
            965
          ],
          [
            453,
            965
          ]
        ]
      ]
    },
    {
      "id": "room-204-service",
      "label": "204 entry / bath ceiling band",
      "quantity": 98.27999999999999,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            453,
            775
          ],
          [
            531,
            775
          ],
          [
            531,
            831
          ],
          [
            453,
            831
          ]
        ]
      ]
    },
    {
      "id": "room-206-main",
      "label": "206 king studio main ceiling",
      "quantity": 223.49249999999998,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into third-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            538,
            836
          ],
          [
            615,
            836
          ],
          [
            615,
            965
          ],
          [
            538,
            965
          ]
        ]
      ]
    },
    {
      "id": "room-206-service",
      "label": "206 entry / bath ceiling band",
      "quantity": 97.01999999999998,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            538,
            775
          ],
          [
            615,
            775
          ],
          [
            615,
            831
          ],
          [
            538,
            831
          ]
        ]
      ]
    },
    {
      "id": "room-208-main",
      "label": "208 king studio main ceiling",
      "quantity": 214.78499999999997,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into third-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            624,
            836
          ],
          [
            698,
            836
          ],
          [
            698,
            965
          ],
          [
            624,
            965
          ]
        ]
      ]
    },
    {
      "id": "room-208-service",
      "label": "208 entry / bath ceiling band",
      "quantity": 93.24,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            624,
            775
          ],
          [
            698,
            775
          ],
          [
            698,
            831
          ],
          [
            624,
            831
          ]
        ]
      ]
    },
    {
      "id": "room-210-main",
      "label": "210 king studio main ceiling",
      "quantity": 217.68749999999997,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into third-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            707,
            836
          ],
          [
            782,
            836
          ],
          [
            782,
            965
          ],
          [
            707,
            965
          ]
        ]
      ]
    },
    {
      "id": "room-210-service",
      "label": "210 entry / bath ceiling band",
      "quantity": 94.49999999999999,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            707,
            775
          ],
          [
            782,
            775
          ],
          [
            782,
            831
          ],
          [
            707,
            831
          ]
        ]
      ]
    },
    {
      "id": "room-212-main",
      "label": "212 king studio main ceiling",
      "quantity": 223.49249999999998,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into third-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            790,
            836
          ],
          [
            867,
            836
          ],
          [
            867,
            965
          ],
          [
            790,
            965
          ]
        ]
      ]
    },
    {
      "id": "room-212-service",
      "label": "212 entry / bath ceiling band",
      "quantity": 97.01999999999998,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            790,
            775
          ],
          [
            867,
            775
          ],
          [
            867,
            831
          ],
          [
            790,
            831
          ]
        ]
      ]
    },
    {
      "id": "room-214-main",
      "label": "214 king studio main ceiling",
      "quantity": 220.58999999999997,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into third-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            875,
            836
          ],
          [
            951,
            836
          ],
          [
            951,
            965
          ],
          [
            875,
            965
          ]
        ]
      ]
    },
    {
      "id": "room-214-service",
      "label": "214 entry / bath ceiling band",
      "quantity": 95.75999999999999,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            875,
            775
          ],
          [
            951,
            775
          ],
          [
            951,
            831
          ],
          [
            875,
            831
          ]
        ]
      ]
    },
    {
      "id": "room-216-main",
      "label": "216 queen queen main ceiling",
      "quantity": 292.40999999999997,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into third-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            960,
            836
          ],
          [
            1036,
            836
          ],
          [
            1036,
            1007
          ],
          [
            960,
            1007
          ]
        ]
      ]
    },
    {
      "id": "room-216-service",
      "label": "216 entry / bath ceiling band",
      "quantity": 95.75999999999999,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            960,
            775
          ],
          [
            1036,
            775
          ],
          [
            1036,
            831
          ],
          [
            960,
            831
          ]
        ]
      ]
    },
    {
      "id": "room-218-main",
      "label": "218 queen queen main ceiling",
      "quantity": 288.56249999999994,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into third-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            1045,
            836
          ],
          [
            1120,
            836
          ],
          [
            1120,
            1007
          ],
          [
            1045,
            1007
          ]
        ]
      ]
    },
    {
      "id": "room-218-service",
      "label": "218 entry / bath ceiling band",
      "quantity": 94.49999999999999,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            1045,
            775
          ],
          [
            1120,
            775
          ],
          [
            1120,
            831
          ],
          [
            1045,
            831
          ]
        ]
      ]
    },
    {
      "id": "room-220-main",
      "label": "220 queen queen main ceiling",
      "quantity": 292.40999999999997,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into third-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            1129,
            836
          ],
          [
            1205,
            836
          ],
          [
            1205,
            1007
          ],
          [
            1129,
            1007
          ]
        ]
      ]
    },
    {
      "id": "room-220-service",
      "label": "220 entry / bath ceiling band",
      "quantity": 95.75999999999999,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            1129,
            775
          ],
          [
            1205,
            775
          ],
          [
            1205,
            831
          ],
          [
            1129,
            831
          ]
        ]
      ]
    },
    {
      "id": "room-222-main",
      "label": "222 queen queen main ceiling",
      "quantity": 296.25749999999994,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into third-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            1213,
            836
          ],
          [
            1290,
            836
          ],
          [
            1290,
            1007
          ],
          [
            1213,
            1007
          ]
        ]
      ]
    },
    {
      "id": "room-222-service",
      "label": "222 entry / bath ceiling band",
      "quantity": 97.01999999999998,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            1213,
            775
          ],
          [
            1290,
            775
          ],
          [
            1290,
            831
          ],
          [
            1213,
            831
          ]
        ]
      ]
    },
    {
      "id": "room-224-main",
      "label": "224 connecting queen queen main ceiling",
      "quantity": 300.10499999999996,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into third-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            1298,
            836
          ],
          [
            1376,
            836
          ],
          [
            1376,
            1007
          ],
          [
            1298,
            1007
          ]
        ]
      ]
    },
    {
      "id": "room-224-service",
      "label": "224 entry / bath ceiling band",
      "quantity": 98.27999999999999,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            1298,
            775
          ],
          [
            1376,
            775
          ],
          [
            1376,
            831
          ],
          [
            1298,
            831
          ]
        ]
      ]
    },
    {
      "id": "room-226-main",
      "label": "226 accessible queen queen main ceiling",
      "quantity": 392.44499999999994,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual floor field; do not carry the second-floor226 room type into third-floor326. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            1384,
            836
          ],
          [
            1486,
            836
          ],
          [
            1486,
            1007
          ],
          [
            1384,
            1007
          ]
        ]
      ]
    },
    {
      "id": "room-226-service",
      "label": "226 entry / bath ceiling band",
      "quantity": 128.51999999999998,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: Local height not tagged on this RCP. Approximate clear horizontal trace; Gross band before service partitions; resolve detailed ceiling breaks before net gypsum quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            1384,
            775
          ],
          [
            1486,
            775
          ],
          [
            1486,
            831
          ],
          [
            1384,
            831
          ]
        ]
      ]
    },
    {
      "id": "room-207-main-west",
      "label": "207 accessible one-bedroom \u00b7 west main ceiling",
      "quantity": 165.86999999999998,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Same suite, distinct ceiling field. Missing east height on A3.3 retained. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            539,
            577
          ],
          [
            615,
            577
          ],
          [
            615,
            674
          ],
          [
            539,
            674
          ]
        ]
      ]
    },
    {
      "id": "room-207-main-east",
      "label": "207 accessible one-bedroom \u00b7 east main ceiling",
      "quantity": 165.86999999999998,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Same suite, distinct ceiling field. Missing east height on A3.3 retained. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            622,
            577
          ],
          [
            698,
            577
          ],
          [
            698,
            674
          ],
          [
            622,
            674
          ]
        ]
      ]
    },
    {
      "id": "room-207-service",
      "label": "207 combined service ceiling band",
      "quantity": 200.33999999999997,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: Local height untagged. Approximate clear horizontal trace; Gross service band before interior wall/boxed-service deductions. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            539,
            678
          ],
          [
            698,
            678
          ],
          [
            698,
            734
          ],
          [
            539,
            734
          ]
        ]
      ]
    },
    {
      "id": "room-202-main-west",
      "label": "202 one-bedroom west main ceiling",
      "quantity": 142.06499999999997,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            282,
            883
          ],
          [
            359,
            883
          ],
          [
            359,
            965
          ],
          [
            282,
            965
          ]
        ]
      ]
    },
    {
      "id": "room-202-main-east",
      "label": "202 one-bedroom east main ceiling",
      "quantity": 226.79999999999998,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            367,
            839
          ],
          [
            447,
            839
          ],
          [
            447,
            965
          ],
          [
            367,
            965
          ]
        ]
      ]
    },
    {
      "id": "room-202-service",
      "label": "202 service ceiling around stair",
      "quantity": 128.92499999999998,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: Local height untagged. Approximate clear horizontal trace; Stair footprint excluded; service partitions still require detail tracing. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            282,
            838
          ],
          [
            402,
            838
          ],
          [
            402,
            776
          ],
          [
            447,
            776
          ],
          [
            447,
            834
          ],
          [
            362,
            834
          ],
          [
            362,
            879
          ],
          [
            282,
            879
          ]
        ]
      ]
    },
    {
      "id": "corridor",
      "label": "228 corridor ceiling",
      "quantity": 820.6199999999999,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Main strip plus east return. Reconcile corridor device symbols with electrical/fire protection. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            282,
            741
          ],
          [
            1360,
            741
          ],
          [
            1360,
            710
          ],
          [
            1487,
            710
          ],
          [
            1487,
            768
          ],
          [
            282,
            768
          ]
        ]
      ]
    },
    {
      "id": "corridor-boundary",
      "label": "Corridor gross ceiling boundary",
      "quantity": 378.9,
      "unit": "LF",
      "color": "#398d79",
      "basis": "Clear perimeter including doorway interruptions; not net edge trim or construction wall LF. Deduct openings before perimeter takeoff.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "line": [
        [
          282,
          741
        ],
        [
          1360,
          741
        ],
        [
          1360,
          710
        ],
        [
          1487,
          710
        ],
        [
          1487,
          768
        ],
        [
          282,
          768
        ],
        [
          282,
          741
        ]
      ]
    },
    {
      "id": "elevator-lobby",
      "label": "Elevator lobby 200",
      "quantity": 215.95499999999998,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: 7 feet 6 inches shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            1298,
            597
          ],
          [
            1376,
            597
          ],
          [
            1376,
            707
          ],
          [
            1360,
            707
          ],
          [
            1360,
            734
          ],
          [
            1314,
            734
          ],
          [
            1314,
            693
          ],
          [
            1298,
            693
          ]
        ]
      ]
    },
    {
      "id": "storage",
      "label": "223 storage",
      "quantity": 49.13999999999999,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Unhatched / material unresolved. Height: Height not shown. Approximate clear horizontal trace; Do not assign legend default or a floor finish as ceiling material. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            1298,
            562
          ],
          [
            1376,
            562
          ],
          [
            1376,
            590
          ],
          [
            1298,
            590
          ]
        ]
      ]
    },
    {
      "id": "stair-west",
      "label": "Stair West reference footprint",
      "quantity": 136.89,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "NO finished-ceiling assumption. Height: Height / soffit extent not shown. Approximate clear horizontal trace; Reference only; excludes shaft/stair void from finished-ceiling totals. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            282,
            778
          ],
          [
            399,
            778
          ],
          [
            399,
            830
          ],
          [
            282,
            830
          ]
        ]
      ]
    },
    {
      "id": "stair-east",
      "label": "Stair East reference footprint",
      "quantity": 137.36249999999998,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "NO finished-ceiling assumption. Height: Height / soffit extent not shown. Approximate clear horizontal trace; Reference only; excludes shaft/stair void from finished-ceiling totals. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            1431,
            591
          ],
          [
            1486,
            591
          ],
          [
            1486,
            702
          ],
          [
            1431,
            702
          ]
        ]
      ]
    },
    {
      "id": "elevator-shaft",
      "label": "Elevator Shaft reference footprint",
      "quantity": 104.89499999999998,
      "unit": "SF",
      "color": "#299bba",
      "basis": "NO finished-ceiling assumption. Height: Height / soffit extent not shown. Approximate clear horizontal trace; Reference only; excludes shaft/stair void from finished-ceiling totals. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.2",
      "parentSheet": "Floor 2",
      "polygons": [
        [
          [
            1384,
            591
          ],
          [
            1426,
            591
          ],
          [
            1426,
            702
          ],
          [
            1384,
            702
          ]
        ]
      ]
    }
  ]
}