  "sheet": "A3.1",
  "coordinateSpace": {
    "width": 1920,
    "height": 1280
  },
  "calibration": {
    "pixelsPerFoot": 6.666666666666667,
    "printedScale": "1/8 inch = 1 foot",
    "checks": [
      {
        "view": "Printed1/8 inch at72 PDF points per inch",
        "pixelsPerFoot": 6.666666666666667,
        "basis": "9 PDF points per foot divided by1.35"
      },
      {
        "view": "Registered grid6\u20137 against A2.16 12-foot8-inch bay",
        "sourcePixels": 84.5,
        "referenceFeet": 12.666666666666666,
        "pixelsPerFoot": 6.671052631578948
      },
      {
        "view": "Registered grid14\u201315 against A2.16 16-foot8-inch bay",
        "sourcePixels": 111.2,
        "referenceFeet": 16.666666666666668,
        "pixelsPerFoot": 6.672
      }
    ]
  },
  "rows": [
    {
      "id": "101-main",
      "label": "101 main ceiling",
      "quantity": 217.68749999999997,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            291,
            500
          ],
          [
            366,
            500
          ],
          [
            366,
            629
          ],
          [
            291,
            629
          ]
        ]
      ]
    },
    {
      "id": "101-service",
      "label": "101 entry / bath ceiling band",
      "quantity": 91.12499999999999,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: Local RCP height not tagged. Approximate clear horizontal trace; Gross service band; detailed room ceiling breaks require reconciliation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            291,
            636
          ],
          [
            366,
            636
          ],
          [
            366,
            690
          ],
          [
            291,
            690
          ]
        ]
      ]
    },
    {
      "id": "103-main",
      "label": "103 main ceiling",
      "quantity": 220.58999999999997,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            376,
            500
          ],
          [
            452,
            500
          ],
          [
            452,
            629
          ],
          [
            376,
            629
          ]
        ]
      ]
    },
    {
      "id": "103-service",
      "label": "103 entry / bath ceiling band",
      "quantity": 92.33999999999999,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: Local RCP height not tagged. Approximate clear horizontal trace; Gross service band; detailed room ceiling breaks require reconciliation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            376,
            636
          ],
          [
            452,
            636
          ],
          [
            452,
            690
          ],
          [
            376,
            690
          ]
        ]
      ]
    },
    {
      "id": "105-main",
      "label": "105 main ceiling",
      "quantity": 217.68749999999997,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            461,
            500
          ],
          [
            536,
            500
          ],
          [
            536,
            629
          ],
          [
            461,
            629
          ]
        ]
      ]
    },
    {
      "id": "105-service",
      "label": "105 entry / bath ceiling band",
      "quantity": 91.12499999999999,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Painted gypsum-board hatch. Height: Local RCP height not tagged. Approximate clear horizontal trace; Gross service band; detailed room ceiling breaks require reconciliation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            461,
            636
          ],
          [
            536,
            636
          ],
          [
            536,
            690
          ],
          [
            461,
            690
          ]
        ]
      ]
    },
    {
      "id": "107-main-west",
      "label": "107 accessible one-bedroom \u00b7 west main ceiling",
      "quantity": 156.51,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            546,
            536
          ],
          [
            620,
            536
          ],
          [
            620,
            630
          ],
          [
            546,
            630
          ]
        ]
      ]
    },
    {
      "id": "107-main-east",
      "label": "107 accessible one-bedroom \u00b7 east main ceiling",
      "quantity": 162.855,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            628,
            536
          ],
          [
            705,
            536
          ],
          [
            705,
            630
          ],
          [
            628,
            630
          ]
        ]
      ]
    },
    {
      "id": "107-service",
      "label": "107 combined service ceiling band",
      "quantity": 193.18499999999997,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum-board hatch. Height: Local RCP height not tagged. Approximate clear horizontal trace; Gross band includes internal partitions before net deductions. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            546,
            636
          ],
          [
            705,
            636
          ],
          [
            705,
            690
          ],
          [
            546,
            690
          ]
        ]
      ]
    },
    {
      "id": "104-main",
      "label": "104 main ceiling",
      "quantity": 221.06249999999997,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            461,
            792
          ],
          [
            536,
            792
          ],
          [
            536,
            923
          ],
          [
            461,
            923
          ]
        ]
      ]
    },
    {
      "id": "104-service",
      "label": "104 entry / bath ceiling band",
      "quantity": 86.06249999999999,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: Local RCP height not tagged. Approximate clear horizontal trace; Gross band before partitions/ceiling-break deductions. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            461,
            735
          ],
          [
            536,
            735
          ],
          [
            536,
            786
          ],
          [
            461,
            786
          ]
        ]
      ]
    },
    {
      "id": "106-main",
      "label": "106 main ceiling",
      "quantity": 218.11499999999998,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            546,
            792
          ],
          [
            620,
            792
          ],
          [
            620,
            923
          ],
          [
            546,
            923
          ]
        ]
      ]
    },
    {
      "id": "106-service",
      "label": "106 entry / bath ceiling band",
      "quantity": 84.91499999999999,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: Local RCP height not tagged. Approximate clear horizontal trace; Gross band before partitions/ceiling-break deductions. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            546,
            735
          ],
          [
            620,
            735
          ],
          [
            620,
            786
          ],
          [
            546,
            786
          ]
        ]
      ]
    },
    {
      "id": "108-main",
      "label": "108 main ceiling",
      "quantity": 221.06249999999997,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            630,
            792
          ],
          [
            705,
            792
          ],
          [
            705,
            923
          ],
          [
            630,
            923
          ]
        ]
      ]
    },
    {
      "id": "108-service",
      "label": "108 entry / bath ceiling band",
      "quantity": 86.06249999999999,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: Local RCP height not tagged. Approximate clear horizontal trace; Gross band before partitions/ceiling-break deductions. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            630,
            735
          ],
          [
            705,
            735
          ],
          [
            705,
            786
          ],
          [
            630,
            786
          ]
        ]
      ]
    },
    {
      "id": "110-main",
      "label": "110 main ceiling",
      "quantity": 221.06249999999997,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            716,
            792
          ],
          [
            791,
            792
          ],
          [
            791,
            923
          ],
          [
            716,
            923
          ]
        ]
      ]
    },
    {
      "id": "110-service",
      "label": "110 entry / bath ceiling band",
      "quantity": 86.06249999999999,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum-board hatch. Height: Local RCP height not tagged. Approximate clear horizontal trace; Gross band before partitions/ceiling-break deductions. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            716,
            735
          ],
          [
            791,
            735
          ],
          [
            791,
            786
          ],
          [
            716,
            786
          ]
        ]
      ]
    },
    {
      "id": "112-main",
      "label": "112 main ceiling",
      "quantity": 221.06249999999997,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            800,
            792
          ],
          [
            875,
            792
          ],
          [
            875,
            923
          ],
          [
            800,
            923
          ]
        ]
      ]
    },
    {
      "id": "112-service",
      "label": "112 entry / bath ceiling band",
      "quantity": 86.06249999999999,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: Local RCP height not tagged. Approximate clear horizontal trace; Gross band before partitions/ceiling-break deductions. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            800,
            735
          ],
          [
            875,
            735
          ],
          [
            875,
            786
          ],
          [
            800,
            786
          ]
        ]
      ]
    },
    {
      "id": "114-main",
      "label": "114 main ceiling",
      "quantity": 221.06249999999997,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            885,
            792
          ],
          [
            960,
            792
          ],
          [
            960,
            923
          ],
          [
            885,
            923
          ]
        ]
      ]
    },
    {
      "id": "114-service",
      "label": "114 entry / bath ceiling band",
      "quantity": 86.06249999999999,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: Local RCP height not tagged. Approximate clear horizontal trace; Gross band before partitions/ceiling-break deductions. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            885,
            735
          ],
          [
            960,
            735
          ],
          [
            960,
            786
          ],
          [
            885,
            786
          ]
        ]
      ]
    },
    {
      "id": "102-west",
      "label": "102 one-bedroom west main ceiling",
      "quantity": 143.43749999999997,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            291,
            838
          ],
          [
            366,
            838
          ],
          [
            366,
            923
          ],
          [
            291,
            923
          ]
        ]
      ]
    },
    {
      "id": "102-east",
      "label": "102 one-bedroom east main ceiling",
      "quantity": 220.58999999999997,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            376,
            794
          ],
          [
            452,
            794
          ],
          [
            452,
            923
          ],
          [
            376,
            923
          ]
        ]
      ]
    },
    {
      "id": "102-service",
      "label": "102 service ceiling around stair",
      "quantity": 109.55249999999998,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Painted gypsum-board hatch. Height: Local RCP height not tagged. Approximate clear horizontal trace; Stair excluded; service partitions require detail reconciliation. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            291,
            797
          ],
          [
            408,
            797
          ],
          [
            408,
            736
          ],
          [
            452,
            736
          ],
          [
            452,
            788
          ],
          [
            370,
            788
          ],
          [
            370,
            834
          ],
          [
            291,
            834
          ]
        ]
      ]
    },
    {
      "id": "public-109",
      "label": "109 Mechanical ceiling / open zone",
      "quantity": 177.18749999999997,
      "unit": "SF",
      "color": "#299bba",
      "basis": "OPEN CEILING. Height: Open; no finish ceiling. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            715,
            499
          ],
          [
            790,
            499
          ],
          [
            790,
            604
          ],
          [
            715,
            604
          ]
        ]
      ]
    },
    {
      "id": "public-111",
      "label": "111 Engineer ceiling / open zone",
      "quantity": 101.24999999999999,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "2x2 grid hatch. Height: Height not shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            715,
            612
          ],
          [
            790,
            612
          ],
          [
            790,
            672
          ],
          [
            715,
            672
          ]
        ]
      ]
    },
    {
      "id": "public-113",
      "label": "113 Electrical ceiling / open zone",
      "quantity": 133.38,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "OPEN CEILING. Height: Open; no finish ceiling. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            799,
            499
          ],
          [
            875,
            499
          ],
          [
            875,
            577
          ],
          [
            799,
            577
          ]
        ]
      ]
    },
    {
      "id": "public-115",
      "label": "115 PBX ceiling / open zone",
      "quantity": 73.52999999999999,
      "unit": "SF",
      "color": "#398d79",
      "basis": "OPEN CEILING. Height: Open; no finish ceiling. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            799,
            588
          ],
          [
            875,
            588
          ],
          [
            875,
            631
          ],
          [
            799,
            631
          ]
        ]
      ]
    },
    {
      "id": "public-117",
      "label": "117 Employee breakroom ceiling / open zone",
      "quantity": 128.20499999999998,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "2x2 grid hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            884,
            499
          ],
          [
            958,
            499
          ],
          [
            958,
            576
          ],
          [
            884,
            576
          ]
        ]
      ]
    },
    {
      "id": "public-119",
      "label": "119 Food prep ceiling / open zone",
      "quantity": 265.8375,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "2x2 grid hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            799,
            641
          ],
          [
            884,
            641
          ],
          [
            884,
            588
          ],
          [
            959,
            588
          ],
          [
            959,
            690
          ],
          [
            799,
            690
          ]
        ]
      ]
    },
    {
      "id": "public-121",
      "label": "121 Proposed sprinkler room ceiling / open zone",
      "quantity": 90.945,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            969,
            499
          ],
          [
            1063,
            499
          ],
          [
            1063,
            542
          ],
          [
            969,
            542
          ]
        ]
      ]
    },
    {
      "id": "public-125",
      "label": "125 Dryer room ceiling / open zone",
      "quantity": 57.91499999999999,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "2x2 grid hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            1072,
            499
          ],
          [
            1138,
            499
          ],
          [
            1138,
            538
          ],
          [
            1072,
            538
          ]
        ]
      ]
    },
    {
      "id": "public-131",
      "label": "131 Laundry discharge ceiling / open zone",
      "quantity": 104.89499999999998,
      "unit": "SF",
      "color": "#299bba",
      "basis": "2x2 grid hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            1249,
            499
          ],
          [
            1323,
            499
          ],
          [
            1323,
            562
          ],
          [
            1249,
            562
          ]
        ]
      ]
    },
    {
      "id": "public-133",
      "label": "133 Manager office ceiling / open zone",
      "quantity": 69.92999999999999,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "2x2 grid hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            1249,
            587
          ],
          [
            1323,
            587
          ],
          [
            1323,
            629
          ],
          [
            1249,
            629
          ]
        ]
      ]
    },
    {
      "id": "public-116",
      "label": "116 Women ceiling / open zone",
      "quantity": 48.23999999999737,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: 8 feet 6 inches shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            996.667,
            757.0
          ],
          [
            1044.667,
            757.0
          ],
          [
            1044.667,
            801.6666666666667
          ],
          [
            996.667,
            801.6666666666667
          ]
        ]
      ]
    },
    {
      "id": "public-118",
      "label": "118 Men ceiling / open zone",
      "quantity": 48.23999999999737,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: 8 feet 6 inches shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            996.667,
            807.0
          ],
          [
            1044.667,
            807.0
          ],
          [
            1044.667,
            851.6666666666667
          ],
          [
            996.667,
            851.6666666666667
          ]
        ]
      ]
    },
    {
      "id": "public-120",
      "label": "120 Storage ceiling / open zone",
      "quantity": 46.8,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: 8 feet 6 inches shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            996.667,
            857.6666666666667
          ],
          [
            1044.667,
            857.6666666666667
          ],
          [
            1044.667,
            901.0
          ],
          [
            996.667,
            901.0
          ]
        ]
      ]
    },
    {
      "id": "public-122",
      "label": "122 Sales ceiling / open zone",
      "quantity": 59.03999999999999,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "2x2 grid hatch. Height: 9 feet 3 inches shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            996.667,
            906.3333333333333
          ],
          [
            1044.667,
            906.3333333333333
          ],
          [
            1044.667,
            961.0
          ],
          [
            996.667,
            961.0
          ]
        ]
      ]
    },
    {
      "id": "public-132",
      "label": "132 Guest laundry ceiling / open zone",
      "quantity": 148.1999999999991,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: 9 feet 3 inches shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            1390.0003333333334,
            742.3333333333333
          ],
          [
            1494.0003333333334,
            742.3333333333333
          ],
          [
            1494.0003333333334,
            805.6666666666667
          ],
          [
            1390.0003333333334,
            805.6666666666667
          ]
        ]
      ]
    },
    {
      "id": "public-135",
      "label": "135 TV lounge ceiling / open zone",
      "quantity": 149.76,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Painted gypsum-board hatch. Height: 8 feet 10 inches shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            1390.0003333333334,
            670.3333333333333
          ],
          [
            1494.0003333333334,
            670.3333333333333
          ],
          [
            1494.0003333333334,
            734.3333333333333
          ],
          [
            1390.0003333333334,
            734.3333333333333
          ]
        ]
      ]
    },
    {
      "id": "public-127",
      "label": "127 Laundry circulation ceiling / open zone",
      "quantity": 296.97749999999996,
      "unit": "SF",
      "color": "#299bba",
      "basis": "2x2 grid hatch. Height: 8 feet shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            969,
            547
          ],
          [
            1069,
            547
          ],
          [
            1069,
            542
          ],
          [
            1142,
            542
          ],
          [
            1142,
            499
          ],
          [
            1240,
            499
          ],
          [
            1240,
            577
          ],
          [
            969,
            577
          ]
        ]
      ]
    },
    {
      "id": "public-136",
      "label": "136 Servery strip ceiling / open zone",
      "quantity": 144.42749999999998,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: 8 feet 10 inches shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            969,
            588
          ],
          [
            1100,
            588
          ],
          [
            1100,
            637
          ],
          [
            969,
            637
          ]
        ]
      ]
    },
    {
      "id": "public-137",
      "label": "137 Workstation strip ceiling / open zone",
      "quantity": 130.61249999999998,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: 8 feet 10 inches shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            1105,
            588
          ],
          [
            1240,
            588
          ],
          [
            1240,
            631
          ],
          [
            1105,
            631
          ]
        ]
      ]
    },
    {
      "id": "public-123",
      "label": "123 Breakfast zone ceiling / open zone",
      "quantity": 137.16,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: 8 feet 10 inches shown. Approximate clear horizontal trace; Actual RCP clear-zone trace; same-room A2.16 grid registration used for context. OPEN fields are reference exposed areas, not suspended-ceiling quantity. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            969,
            642
          ],
          [
            1096,
            642
          ],
          [
            1096,
            690
          ],
          [
            969,
            690
          ]
        ]
      ]
    },
    {
      "id": "lobby-act",
      "label": "124 lobby inset acoustic field",
      "quantity": 340.67249999999996,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "6x48 acoustic-tile hatch (cross-reference A3.2 legend). Height: 9 feet 6 inches shown. Approximate clear horizontal trace; Panel count/waste not derived from partial edge tiles. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            1088,
            787
          ],
          [
            1235,
            787
          ],
          [
            1235,
            890
          ],
          [
            1088,
            890
          ]
        ]
      ]
    },
    {
      "id": "lobby-gb",
      "label": "124 lobby surrounding ceiling",
      "quantity": 792.6075000000001,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Painted gypsum-board hatch. Height: 8 feet 10 inches shown. Approximate clear horizontal trace; Inset acoustic field excluded. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            1049,
            732
          ],
          [
            1297,
            732
          ],
          [
            1297,
            906
          ],
          [
            1213,
            906
          ],
          [
            1213,
            950
          ],
          [
            1049,
            950
          ]
        ],
        [
          [
            1088,
            787
          ],
          [
            1235,
            787
          ],
          [
            1235,
            890
          ],
          [
            1088,
            890
          ]
        ]
      ]
    },
    {
      "id": "lobby-inset-edge",
      "label": "Lobby inset ceiling perimeter",
      "quantity": 75.0,
      "unit": "LF",
      "color": "#cf4f62",
      "basis": "Interface edge, not automatically installed trim. Height difference shown8 inches; edge profiles/supports require section.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "line": [
        [
          1088,
          787
        ],
        [
          1235,
          787
        ],
        [
          1235,
          890
        ],
        [
          1088,
          890
        ],
        [
          1088,
          787
        ]
      ]
    },
    {
      "id": "lobby-step-face",
      "label": "Lobby inset step-face allowance",
      "quantity": 50.0,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Geometric perimeter \u00d7 shown8-inch difference. ALLOWANCE only: verify whether inset edge is vertical, open, sloped or concealed before adding to finish scope.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "line": [
        [
          1088,
          787
        ],
        [
          1235,
          787
        ],
        [
          1235,
          890
        ],
        [
          1088,
          890
        ],
        [
          1088,
          787
        ]
      ]
    },
    {
      "id": "fitness-decorative",
      "label": "130 fitness decorative inset",
      "quantity": 211.52249999999998,
      "unit": "SF",
      "color": "#299bba",
      "basis": "2x4 decorative hatch (cross-reference A3.2 legend). Height: 9 feet 6 inches shown. Approximate clear horizontal trace;  No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            1341,
            848
          ],
          [
            1460,
            848
          ],
          [
            1460,
            927
          ],
          [
            1341,
            927
          ]
        ]
      ]
    },
    {
      "id": "fitness-gb",
      "label": "130 fitness surrounding ceiling",
      "quantity": 519.48,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: 9 feet 3 inches shown. Approximate clear horizontal trace; Decorative inset excluded. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            1305,
            765
          ],
          [
            1381,
            765
          ],
          [
            1381,
            812
          ],
          [
            1494,
            812
          ],
          [
            1494,
            965
          ],
          [
            1305,
            965
          ]
        ],
        [
          [
            1341,
            848
          ],
          [
            1460,
            848
          ],
          [
            1460,
            927
          ],
          [
            1341,
            927
          ]
        ]
      ]
    },
    {
      "id": "fitness-inset-edge",
      "label": "Fitness inset ceiling perimeter",
      "quantity": 59.4,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Interface only;3-inch height difference shown, edge trim/detail not provided.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "line": [
        [
          1341,
          848
        ],
        [
          1460,
          848
        ],
        [
          1460,
          927
        ],
        [
          1341,
          927
        ],
        [
          1341,
          848
        ]
      ]
    },
    {
      "id": "fitness-step-face",
      "label": "Fitness inset step-face allowance",
      "quantity": 14.85,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Geometric perimeter \u00d73-inch difference. ALLOWANCE only until vertical edge/profile is confirmed.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "line": [
        [
          1341,
          848
        ],
        [
          1460,
          848
        ],
        [
          1460,
          927
        ],
        [
          1341,
          927
        ],
        [
          1341,
          848
        ]
      ]
    },
    {
      "id": "registration-canopy",
      "label": "Registration desk533 ceiling feature",
      "quantity": 117.17999999999998,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Dense grid feature; construction/material unresolved. Height: Height not tagged. Approximate clear horizontal trace; Do not assume ordinary tile grid from this feature pattern. Coordination with desk/millwork and feature section required. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            1217,
            638
          ],
          [
            1301,
            638
          ],
          [
            1301,
            700
          ],
          [
            1217,
            700
          ]
        ]
      ]
    },
    {
      "id": "registration-width",
      "label": "Registration feature printed width reference",
      "quantity": 12.149999999999999,
      "unit": "LF",
      "color": "#b06bad",
      "basis": "Source dimension12 feet2-1/2 inches is controlling; line trace approximate. Depth, suspension and feature height unresolved.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "line": [
        [
          1218,
          714
        ],
        [
          1299,
          714
        ]
      ]
    },
    {
      "id": "market",
      "label": "129 market ceiling field",
      "quantity": 63.31499999999999,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: Not individually height-tagged. Approximate clear horizontal trace; Unique source zone; reconcile with existing floor/room takeoffs, not additive floor area. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            1122,
            649
          ],
          [
            1189,
            649
          ],
          [
            1189,
            691
          ],
          [
            1122,
            691
          ]
        ]
      ]
    },
    {
      "id": "market-soffit",
      "label": "Market west lower strip",
      "quantity": 20.272499999999997,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Painted gypsum board. Height: 7 feet shown. Approximate clear horizontal trace; Unique source zone; reconcile with existing floor/room takeoffs, not additive floor area. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            1103,
            638
          ],
          [
            1120,
            638
          ],
          [
            1120,
            691
          ],
          [
            1103,
            691
          ]
        ]
      ]
    },
    {
      "id": "work-soffit",
      "label": "Workstation lower strip",
      "quantity": 10.147499999999999,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Painted gypsum board. Height: 7 feet shown. Approximate clear horizontal trace; Unique source zone; reconcile with existing floor/room takeoffs, not additive floor area. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            1132,
            638
          ],
          [
            1173,
            638
          ],
          [
            1173,
            649
          ],
          [
            1132,
            649
          ]
        ]
      ]
    },
    {
      "id": "corridor",
      "label": "Guest-wing corridor",
      "quantity": 454.94999999999993,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Painted gypsum-board hatch. Height: Height not locally shown. Approximate clear horizontal trace; Unique source zone; reconcile with existing floor/room takeoffs, not additive floor area. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            291,
            697
          ],
          [
            965,
            697
          ],
          [
            965,
            727
          ],
          [
            291,
            727
          ]
        ]
      ]
    },
    {
      "id": "public-cross",
      "label": "Public cross-circulation strip",
      "quantity": 278.775,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Painted gypsum-board hatch. Height: Local lower portion9 feet6 inches; remainder untagged. Approximate clear horizontal trace; Unique source zone; reconcile with existing floor/room takeoffs, not additive floor area. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            968,
            697
          ],
          [
            1381,
            697
          ],
          [
            1381,
            727
          ],
          [
            968,
            727
          ]
        ]
      ]
    },
    {
      "id": "east-lobby",
      "label": "East public circulation",
      "quantity": 331.55999999999995,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Painted gypsum-board hatch. Height: Local height not shown. Approximate clear horizontal trace; Unique source zone; reconcile with existing floor/room takeoffs, not additive floor area. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            1331,
            518
          ],
          [
            1379,
            518
          ],
          [
            1379,
            760
          ],
          [
            1305,
            760
          ],
          [
            1305,
            640
          ],
          [
            1331,
            640
          ]
        ]
      ]
    },
    {
      "id": "vestibule",
      "label": "126 vestibule",
      "quantity": 59.39999999999999,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Painted gypsum-board hatch. Height: 8 feet10 inches shown. Approximate clear horizontal trace; Unique source zone; reconcile with existing floor/room takeoffs, not additive floor area. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            1237,
            917
          ],
          [
            1297,
            917
          ],
          [
            1297,
            961
          ],
          [
            1237,
            961
          ]
        ]
      ]
    },
    {
      "id": "mechanical128",
      "label": "128 mechanical",
      "quantity": 15.839999999999998,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Unhatched / unresolved. Height: Height not tagged. Approximate clear horizontal trace; Unique source zone; reconcile with existing floor/room takeoffs, not additive floor area. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            1217,
            917
          ],
          [
            1233,
            917
          ],
          [
            1233,
            961
          ],
          [
            1217,
            961
          ]
        ]
      ]
    },
    {
      "id": "mechanical134",
      "label": "134 mechanical",
      "quantity": 39.15,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Painted gypsum-board hatch. Height: 9 feet3 inches shown. Approximate clear horizontal trace; Unique source zone; reconcile with existing floor/room takeoffs, not additive floor area. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            1465,
            747
          ],
          [
            1494,
            747
          ],
          [
            1494,
            807
          ],
          [
            1465,
            807
          ]
        ]
      ]
    },
    {
      "id": "pool015",
      "label": "015 pool-equipment room",
      "quantity": 39.69,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Unresolved. Height: Height not tagged. Approximate clear horizontal trace; Unique source zone; reconcile with existing floor/room takeoffs, not additive floor area. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            392,
            1045
          ],
          [
            434,
            1045
          ],
          [
            434,
            1087
          ],
          [
            392,
            1087
          ]
        ]
      ]
    },
    {
      "id": "pool017",
      "label": "017 unisex ADA restroom",
      "quantity": 52.64999999999999,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Unresolved. Height: Height not tagged. Approximate clear horizontal trace; Unique source zone; reconcile with existing floor/room takeoffs, not additive floor area. No floor-area addition or room-type multiplier. Vertical soffit faces and openings are separate.",
      "sourceSheet": "A3.1",
      "parentSheet": "Floor 1",
      "polygons": [
        [
          [
            890,
            1041
          ],
          [
            942,
            1041
          ],
          [
            942,
            1086
          ],
          [
            890,
            1086
          ]
        ]
      ]
    }
  ]
}