  "sheet": "A2.4",
  "coordinateSpace": {
    "width": 1920,
    "height": 1280
  },
  "calibration": {
    "printedPlanScale": "1/8 inch = 1 foot",
    "pixelsPerFoot": 6.673234192251462,
    "basis": "36 x 24 inch PDF. Common structural grid 3\u20134 equals 84.528 normalized pixels and 12 feet 8 inches on A1.4; grid 4\u20135 independently repeats 84.528 pixels. Printed scale conversion differs by 0.10 percent.",
    "checks": [
      {
        "grid": "3\u20134",
        "pixels": 84.528,
        "feet": 12.666666666666666
      },
      {
        "grid": "4\u20135",
        "pixels": 84.528,
        "feet": 12.666666666666666
      }
    ],
    "registration": {
      "dx": -29.746378942419028,
      "dy": 26.207727430555565,
      "method": "Grid 3 horizontal registration and grid A vertical registration; grids 3\u20134 and 4\u20135 independently checked."
    }
  },
  "rows": [
    {
      "id": "gross-floor",
      "label": "Gross fourth-floor outline",
      "quantity": 12173.212015139325,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced main outline including walls and cores; small facade jogs simplified. Separate core deductions below.",
      "polygons": [
        [
          [
            317.254,
            575.208
          ],
          [
            573.254,
            575.208
          ],
          [
            573.254,
            613.208
          ],
          [
            746.254,
            613.208
          ],
          [
            746.254,
            575.208
          ],
          [
            1361.254,
            575.208
          ],
          [
            1361.254,
            598.208
          ],
          [
            1421.254,
            598.208
          ],
          [
            1421.254,
            625.208
          ],
          [
            1534.254,
            625.208
          ],
          [
            1534.254,
            1054.208
          ],
          [
            998.254,
            1054.208
          ],
          [
            998.254,
            1014.208
          ],
          [
            317.254,
            1014.208
          ]
        ]
      ]
    },
    {
      "id": "floor-deck",
      "label": "Floor deck \u00b7 core deductions",
      "quantity": 11811.046500389866,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Gross floor outline less two complete stair zones and elevator core. Stair landings and structural penetration limits require stair/structural details.",
      "polygons": [
        [
          [
            317.254,
            575.208
          ],
          [
            573.254,
            575.208
          ],
          [
            573.254,
            613.208
          ],
          [
            746.254,
            613.208
          ],
          [
            746.254,
            575.208
          ],
          [
            1361.254,
            575.208
          ],
          [
            1361.254,
            598.208
          ],
          [
            1421.254,
            598.208
          ],
          [
            1421.254,
            625.208
          ],
          [
            1534.254,
            625.208
          ],
          [
            1534.254,
            1054.208
          ],
          [
            998.254,
            1054.208
          ],
          [
            998.254,
            1014.208
          ],
          [
            317.254,
            1014.208
          ]
        ],
        [
          [
            1474.254,
            630.208
          ],
          [
            1526.254,
            630.208
          ],
          [
            1526.254,
            741.208
          ],
          [
            1474.254,
            741.208
          ]
        ],
        [
          [
            324.254,
            817.208
          ],
          [
            438.254,
            817.208
          ],
          [
            438.254,
            869.208
          ],
          [
            324.254,
            869.208
          ]
        ],
        [
          [
            1423.254,
            630.208
          ],
          [
            1464.254,
            630.208
          ],
          [
            1464.254,
            738.208
          ],
          [
            1423.254,
            738.208
          ]
        ]
      ]
    },
    {
      "id": "gypcrete",
      "label": "1\u00bd\u2033 gypcrete \u00b7 floor basis",
      "quantity": 54.68077083513827,
      "unit": "CY",
      "color": "#ba9138",
      "basis": "A0.2 UL L514 1\u00bd-inch gypcrete applied to traced deck basis excluding full stair zones and elevator core. Structural deck limits, wet-area buildup and waste to be resolved.",
      "polygons": [
        [
          [
            317.254,
            575.208
          ],
          [
            573.254,
            575.208
          ],
          [
            573.254,
            613.208
          ],
          [
            746.254,
            613.208
          ],
          [
            746.254,
            575.208
          ],
          [
            1361.254,
            575.208
          ],
          [
            1361.254,
            598.208
          ],
          [
            1421.254,
            598.208
          ],
          [
            1421.254,
            625.208
          ],
          [
            1534.254,
            625.208
          ],
          [
            1534.254,
            1054.208
          ],
          [
            998.254,
            1054.208
          ],
          [
            998.254,
            1014.208
          ],
          [
            317.254,
            1014.208
          ]
        ],
        [
          [
            1474.254,
            630.208
          ],
          [
            1526.254,
            630.208
          ],
          [
            1526.254,
            741.208
          ],
          [
            1474.254,
            741.208
          ]
        ],
        [
          [
            324.254,
            817.208
          ],
          [
            438.254,
            817.208
          ],
          [
            438.254,
            869.208
          ],
          [
            324.254,
            869.208
          ]
        ],
        [
          [
            1423.254,
            630.208
          ],
          [
            1464.254,
            630.208
          ],
          [
            1464.254,
            738.208
          ],
          [
            1423.254,
            738.208
          ]
        ]
      ]
    },
    {
      "id": "exterior",
      "label": "Exterior wall run \u00b7 gross",
      "quantity": 519.6876290257513,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Traced outer perimeter before glazing/opening deductions; wall type, heights and facade jogs to sections.",
      "polygons": [
        [
          [
            317.254,
            575.208
          ],
          [
            573.254,
            575.208
          ],
          [
            573.254,
            613.208
          ],
          [
            746.254,
            613.208
          ],
          [
            746.254,
            575.208
          ],
          [
            1361.254,
            575.208
          ],
          [
            1361.254,
            598.208
          ],
          [
            1421.254,
            598.208
          ],
          [
            1421.254,
            625.208
          ],
          [
            1534.254,
            625.208
          ],
          [
            1534.254,
            1054.208
          ],
          [
            998.254,
            1054.208
          ],
          [
            998.254,
            1014.208
          ],
          [
            317.254,
            1014.208
          ]
        ]
      ]
    },
    {
      "id": "corridor",
      "label": "Guest corridor wall runs",
      "quantity": 333.331361593103,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Two gross wall runs before door openings; north lobby opening omitted. Link exact W1-family assembly.",
      "lines": [
        [
          [
            320.954,
            776.308
          ],
          [
            1335.254,
            776.308
          ]
        ],
        [
          [
            320.954,
            813.008
          ],
          [
            1531.054,
            813.008
          ]
        ]
      ]
    },
    {
      "id": "party",
      "label": "Shared guestroom wall runs",
      "quantity": 671.443010200601,
      "unit": "LF",
      "color": "#cf4f62",
      "basis": "22 gross dividing-wall runs, each physical divider counted once. Connecting openings not deducted. Exact W3/W4 or other assignment awaits wall tags/sections.",
      "lines": [
        [
          [
            403.954,
            578.608
          ],
          [
            403.954,
            776.308
          ]
        ],
        [
          [
            489.954,
            578.608
          ],
          [
            489.954,
            776.308
          ]
        ],
        [
          [
            574.554,
            613.208
          ],
          [
            574.554,
            776.308
          ]
        ],
        [
          [
            743.554,
            613.208
          ],
          [
            743.554,
            776.308
          ]
        ],
        [
          [
            828.154,
            578.608
          ],
          [
            828.154,
            776.308
          ]
        ],
        [
          [
            912.654,
            578.608
          ],
          [
            912.654,
            776.308
          ]
        ],
        [
          [
            997.154,
            578.608
          ],
          [
            997.154,
            776.308
          ]
        ],
        [
          [
            1081.754,
            578.608
          ],
          [
            1081.754,
            776.308
          ]
        ],
        [
          [
            1166.254,
            578.608
          ],
          [
            1166.254,
            776.308
          ]
        ],
        [
          [
            1250.754,
            578.608
          ],
          [
            1250.754,
            776.308
          ]
        ],
        [
          [
            489.954,
            813.008
          ],
          [
            489.954,
            1010.708
          ]
        ],
        [
          [
            574.554,
            813.008
          ],
          [
            574.554,
            1010.708
          ]
        ],
        [
          [
            659.054,
            813.008
          ],
          [
            659.054,
            1010.708
          ]
        ],
        [
          [
            743.554,
            813.008
          ],
          [
            743.554,
            1010.708
          ]
        ],
        [
          [
            828.154,
            813.008
          ],
          [
            828.154,
            1010.708
          ]
        ],
        [
          [
            912.654,
            813.008
          ],
          [
            912.654,
            1010.708
          ]
        ],
        [
          [
            997.154,
            813.008
          ],
          [
            997.154,
            1010.708
          ]
        ],
        [
          [
            1081.754,
            813.008
          ],
          [
            1081.754,
            1050.808
          ]
        ],
        [
          [
            1166.254,
            813.008
          ],
          [
            1166.254,
            1050.808
          ]
        ],
        [
          [
            1250.754,
            813.008
          ],
          [
            1250.754,
            1050.808
          ]
        ],
        [
          [
            1335.254,
            813.008
          ],
          [
            1335.254,
            1050.808
          ]
        ],
        [
          [
            1419.854,
            813.008
          ],
          [
            1419.854,
            1050.808
          ]
        ]
      ]
    },
    {
      "id": "room-001",
      "label": "001 East Stair 1 \u00b7 floor 4 floor / ceiling",
      "quantity": 129.6142950851859,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Floor-level core footprint; carries no finished-floor or ceiling assignment. Reconcile stair landings / shaft openings with details.",
      "polygons": [
        [
          [
            1474.254,
            630.208
          ],
          [
            1526.254,
            630.208
          ],
          [
            1526.254,
            741.208
          ],
          [
            1474.254,
            741.208
          ]
        ]
      ]
    },
    {
      "id": "walls-001",
      "label": "001 East Stair 1 \u00b7 floor 4 gross wall faces",
      "quantity": 48.85183594648066,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Floor-level core footprint; carries no finished-floor or ceiling assignment. Reconcile stair landings / shaft openings with details.",
      "polygons": [
        [
          [
            1474.254,
            630.208
          ],
          [
            1526.254,
            630.208
          ],
          [
            1526.254,
            741.208
          ],
          [
            1474.254,
            741.208
          ]
        ]
      ]
    },
    {
      "id": "room-002",
      "label": "002 West Stair 2 \u00b7 floor 4 floor / ceiling",
      "quantity": 133.11738414154226,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Floor-level core footprint; carries no finished-floor or ceiling assignment. Reconcile stair landings / shaft openings with details.",
      "polygons": [
        [
          [
            324.254,
            817.208
          ],
          [
            438.254,
            817.208
          ],
          [
            438.254,
            869.208
          ],
          [
            324.254,
            869.208
          ]
        ]
      ]
    },
    {
      "id": "walls-002",
      "label": "002 West Stair 2 \u00b7 floor 4 gross wall faces",
      "quantity": 49.75094949150791,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Floor-level core footprint; carries no finished-floor or ceiling assignment. Reconcile stair landings / shaft openings with details.",
      "polygons": [
        [
          [
            324.254,
            817.208
          ],
          [
            438.254,
            817.208
          ],
          [
            438.254,
            869.208
          ],
          [
            324.254,
            869.208
          ]
        ]
      ]
    },
    {
      "id": "room-400",
      "label": "400 Elevator lobby floor / ceiling",
      "quantity": 211.19584983994685,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1340.254,
            637.208
          ],
          [
            1415.254,
            637.208
          ],
          [
            1415.254,
            727.208
          ],
          [
            1399.254,
            727.208
          ],
          [
            1399.254,
            772.208
          ],
          [
            1340.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "walls-400",
      "label": "400 Elevator lobby gross wall faces",
      "quantity": 62.9379481519076,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1340.254,
            637.208
          ],
          [
            1415.254,
            637.208
          ],
          [
            1415.254,
            727.208
          ],
          [
            1399.254,
            727.208
          ],
          [
            1399.254,
            772.208
          ],
          [
            1340.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "room-401",
      "label": "401 King studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            324.254,
            582.208
          ],
          [
            399.254,
            582.208
          ],
          [
            399.254,
            772.208
          ],
          [
            324.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "walls-401",
      "label": "401 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            324.254,
            582.208
          ],
          [
            399.254,
            582.208
          ],
          [
            399.254,
            772.208
          ],
          [
            324.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "room-402",
      "label": "402 King one-bedroom floor / ceiling",
      "quantity": 517.4242181830999,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            324.254,
            878.208
          ],
          [
            442.254,
            878.208
          ],
          [
            442.254,
            817.208
          ],
          [
            484.254,
            817.208
          ],
          [
            484.254,
            1006.208
          ],
          [
            324.254,
            1006.208
          ]
        ]
      ]
    },
    {
      "id": "walls-402",
      "label": "402 King one-bedroom gross wall faces",
      "quantity": 104.59687573817024,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            324.254,
            878.208
          ],
          [
            442.254,
            878.208
          ],
          [
            442.254,
            817.208
          ],
          [
            484.254,
            817.208
          ],
          [
            484.254,
            1006.208
          ],
          [
            324.254,
            1006.208
          ]
        ]
      ]
    },
    {
      "id": "room-403",
      "label": "403 King studio floor / ceiling",
      "quantity": 328.5268775288062,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            408.254,
            582.208
          ],
          [
            485.254,
            582.208
          ],
          [
            485.254,
            772.208
          ],
          [
            408.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "walls-403",
      "label": "403 King studio gross wall faces",
      "quantity": 80.02110550742537,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            408.254,
            582.208
          ],
          [
            485.254,
            582.208
          ],
          [
            485.254,
            772.208
          ],
          [
            408.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "room-404",
      "label": "404 King studio floor / ceiling",
      "quantity": 318.3095344477668,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            494.254,
            817.208
          ],
          [
            569.254,
            817.208
          ],
          [
            569.254,
            1006.208
          ],
          [
            494.254,
            1006.208
          ]
        ]
      ]
    },
    {
      "id": "walls-404",
      "label": "404 King studio gross wall faces",
      "quantity": 79.12199196239813,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            494.254,
            817.208
          ],
          [
            569.254,
            817.208
          ],
          [
            569.254,
            1006.208
          ],
          [
            494.254,
            1006.208
          ]
        ]
      ]
    },
    {
      "id": "room-405",
      "label": "405 Connecting king studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            494.254,
            582.208
          ],
          [
            569.254,
            582.208
          ],
          [
            569.254,
            772.208
          ],
          [
            494.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "walls-405",
      "label": "405 Connecting king studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            494.254,
            582.208
          ],
          [
            569.254,
            582.208
          ],
          [
            569.254,
            772.208
          ],
          [
            494.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "room-406",
      "label": "406 King studio floor / ceiling",
      "quantity": 322.55366157373703,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            578.254,
            817.208
          ],
          [
            654.254,
            817.208
          ],
          [
            654.254,
            1006.208
          ],
          [
            578.254,
            1006.208
          ]
        ]
      ]
    },
    {
      "id": "walls-406",
      "label": "406 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            578.254,
            817.208
          ],
          [
            654.254,
            817.208
          ],
          [
            654.254,
            1006.208
          ],
          [
            578.254,
            1006.208
          ]
        ]
      ]
    },
    {
      "id": "room-407",
      "label": "407 Accessible king one-bedroom floor / ceiling",
      "quantity": 556.9013371643468,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            579.254,
            617.208
          ],
          [
            739.254,
            617.208
          ],
          [
            739.254,
            772.208
          ],
          [
            579.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "walls-407",
      "label": "407 Accessible king one-bedroom gross wall faces",
      "quantity": 94.4069222278614,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            579.254,
            617.208
          ],
          [
            739.254,
            617.208
          ],
          [
            739.254,
            772.208
          ],
          [
            579.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "room-408",
      "label": "408 King studio floor / ceiling",
      "quantity": 322.55366157373703,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            663.254,
            817.208
          ],
          [
            739.254,
            817.208
          ],
          [
            739.254,
            1006.208
          ],
          [
            663.254,
            1006.208
          ]
        ]
      ]
    },
    {
      "id": "walls-408",
      "label": "408 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            663.254,
            817.208
          ],
          [
            739.254,
            817.208
          ],
          [
            739.254,
            1006.208
          ],
          [
            663.254,
            1006.208
          ]
        ]
      ]
    },
    {
      "id": "room-409",
      "label": "409 King studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            748.254,
            582.208
          ],
          [
            823.254,
            582.208
          ],
          [
            823.254,
            772.208
          ],
          [
            748.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "walls-409",
      "label": "409 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            748.254,
            582.208
          ],
          [
            823.254,
            582.208
          ],
          [
            823.254,
            772.208
          ],
          [
            748.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "room-410",
      "label": "410 King studio floor / ceiling",
      "quantity": 318.3095344477668,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            748.254,
            817.208
          ],
          [
            823.254,
            817.208
          ],
          [
            823.254,
            1006.208
          ],
          [
            748.254,
            1006.208
          ]
        ]
      ]
    },
    {
      "id": "walls-410",
      "label": "410 King studio gross wall faces",
      "quantity": 79.12199196239813,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            748.254,
            817.208
          ],
          [
            823.254,
            817.208
          ],
          [
            823.254,
            1006.208
          ],
          [
            748.254,
            1006.208
          ]
        ]
      ]
    },
    {
      "id": "room-411",
      "label": "411 King studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            832.254,
            582.208
          ],
          [
            907.254,
            582.208
          ],
          [
            907.254,
            772.208
          ],
          [
            832.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "walls-411",
      "label": "411 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            832.254,
            582.208
          ],
          [
            907.254,
            582.208
          ],
          [
            907.254,
            772.208
          ],
          [
            832.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "room-412",
      "label": "412 King studio floor / ceiling",
      "quantity": 318.3095344477668,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            832.254,
            817.208
          ],
          [
            907.254,
            817.208
          ],
          [
            907.254,
            1006.208
          ],
          [
            832.254,
            1006.208
          ]
        ]
      ]
    },
    {
      "id": "walls-412",
      "label": "412 King studio gross wall faces",
      "quantity": 79.12199196239813,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            832.254,
            817.208
          ],
          [
            907.254,
            817.208
          ],
          [
            907.254,
            1006.208
          ],
          [
            832.254,
            1006.208
          ]
        ]
      ]
    },
    {
      "id": "room-413",
      "label": "413 King studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            917.254,
            582.208
          ],
          [
            992.254,
            582.208
          ],
          [
            992.254,
            772.208
          ],
          [
            917.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "walls-413",
      "label": "413 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            917.254,
            582.208
          ],
          [
            992.254,
            582.208
          ],
          [
            992.254,
            772.208
          ],
          [
            917.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "room-414",
      "label": "414 King studio floor / ceiling",
      "quantity": 318.3095344477668,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            917.254,
            817.208
          ],
          [
            992.254,
            817.208
          ],
          [
            992.254,
            1006.208
          ],
          [
            917.254,
            1006.208
          ]
        ]
      ]
    },
    {
      "id": "walls-414",
      "label": "414 King studio gross wall faces",
      "quantity": 79.12199196239813,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            917.254,
            817.208
          ],
          [
            992.254,
            817.208
          ],
          [
            992.254,
            1006.208
          ],
          [
            917.254,
            1006.208
          ]
        ]
      ]
    },
    {
      "id": "room-415",
      "label": "415 King studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1001.254,
            582.208
          ],
          [
            1076.254,
            582.208
          ],
          [
            1076.254,
            772.208
          ],
          [
            1001.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "walls-415",
      "label": "415 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1001.254,
            582.208
          ],
          [
            1076.254,
            582.208
          ],
          [
            1076.254,
            772.208
          ],
          [
            1001.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "room-416",
      "label": "416 Queen / queen floor / ceiling",
      "quantity": 380.53427659625083,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1002.254,
            817.208
          ],
          [
            1076.254,
            817.208
          ],
          [
            1076.254,
            1046.208
          ],
          [
            1002.254,
            1046.208
          ]
        ]
      ]
    },
    {
      "id": "walls-416",
      "label": "416 Queen / queen gross wall faces",
      "quantity": 90.8104680477524,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1002.254,
            817.208
          ],
          [
            1076.254,
            817.208
          ],
          [
            1076.254,
            1046.208
          ],
          [
            1002.254,
            1046.208
          ]
        ]
      ]
    },
    {
      "id": "room-417",
      "label": "417 King studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1086.254,
            582.208
          ],
          [
            1161.254,
            582.208
          ],
          [
            1161.254,
            772.208
          ],
          [
            1086.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "walls-417",
      "label": "417 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1086.254,
            582.208
          ],
          [
            1161.254,
            582.208
          ],
          [
            1161.254,
            772.208
          ],
          [
            1086.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "room-418",
      "label": "418 Queen / queen floor / ceiling",
      "quantity": 385.6766316853894,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1086.254,
            817.208
          ],
          [
            1161.254,
            817.208
          ],
          [
            1161.254,
            1046.208
          ],
          [
            1086.254,
            1046.208
          ]
        ]
      ]
    },
    {
      "id": "walls-418",
      "label": "418 Queen / queen gross wall faces",
      "quantity": 91.11017256276148,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1086.254,
            817.208
          ],
          [
            1161.254,
            817.208
          ],
          [
            1161.254,
            1046.208
          ],
          [
            1086.254,
            1046.208
          ]
        ]
      ]
    },
    {
      "id": "room-419",
      "label": "419 King studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1170.254,
            582.208
          ],
          [
            1245.254,
            582.208
          ],
          [
            1245.254,
            772.208
          ],
          [
            1170.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "walls-419",
      "label": "419 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1170.254,
            582.208
          ],
          [
            1245.254,
            582.208
          ],
          [
            1245.254,
            772.208
          ],
          [
            1170.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "room-420",
      "label": "420 Queen / queen floor / ceiling",
      "quantity": 385.6766316853894,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1170.254,
            817.208
          ],
          [
            1245.254,
            817.208
          ],
          [
            1245.254,
            1046.208
          ],
          [
            1170.254,
            1046.208
          ]
        ]
      ]
    },
    {
      "id": "walls-420",
      "label": "420 Queen / queen gross wall faces",
      "quantity": 91.11017256276148,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1170.254,
            817.208
          ],
          [
            1245.254,
            817.208
          ],
          [
            1245.254,
            1046.208
          ],
          [
            1170.254,
            1046.208
          ]
        ]
      ]
    },
    {
      "id": "room-421",
      "label": "421 King studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1255.254,
            582.208
          ],
          [
            1330.254,
            582.208
          ],
          [
            1330.254,
            772.208
          ],
          [
            1255.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "walls-421",
      "label": "421 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1255.254,
            582.208
          ],
          [
            1330.254,
            582.208
          ],
          [
            1330.254,
            772.208
          ],
          [
            1255.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "room-422",
      "label": "422 Queen / queen floor / ceiling",
      "quantity": 385.6766316853894,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1255.254,
            817.208
          ],
          [
            1330.254,
            817.208
          ],
          [
            1330.254,
            1046.208
          ],
          [
            1255.254,
            1046.208
          ]
        ]
      ]
    },
    {
      "id": "walls-422",
      "label": "422 Queen / queen gross wall faces",
      "quantity": 91.11017256276148,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1255.254,
            817.208
          ],
          [
            1330.254,
            817.208
          ],
          [
            1330.254,
            1046.208
          ],
          [
            1255.254,
            1046.208
          ]
        ]
      ]
    },
    {
      "id": "room-423",
      "label": "423 Storage floor / ceiling",
      "quantity": 56.857830068553476,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1340.254,
            582.208
          ],
          [
            1357.254,
            582.208
          ],
          [
            1357.254,
            603.208
          ],
          [
            1415.254,
            603.208
          ],
          [
            1415.254,
            632.208
          ],
          [
            1340.254,
            632.208
          ]
        ]
      ]
    },
    {
      "id": "walls-423",
      "label": "423 Storage gross wall faces",
      "quantity": 37.46306437613548,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1340.254,
            582.208
          ],
          [
            1357.254,
            582.208
          ],
          [
            1357.254,
            603.208
          ],
          [
            1415.254,
            603.208
          ],
          [
            1415.254,
            632.208
          ],
          [
            1340.254,
            632.208
          ]
        ]
      ]
    },
    {
      "id": "room-424",
      "label": "424 Connecting queen / queen floor / ceiling",
      "quantity": 380.53427659625083,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1340.254,
            817.208
          ],
          [
            1414.254,
            817.208
          ],
          [
            1414.254,
            1046.208
          ],
          [
            1340.254,
            1046.208
          ]
        ]
      ]
    },
    {
      "id": "walls-424",
      "label": "424 Connecting queen / queen gross wall faces",
      "quantity": 90.8104680477524,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1340.254,
            817.208
          ],
          [
            1414.254,
            817.208
          ],
          [
            1414.254,
            1046.208
          ],
          [
            1340.254,
            1046.208
          ]
        ]
      ]
    },
    {
      "id": "room-426",
      "label": "426 Accessible king studio floor / ceiling",
      "quantity": 524.5202190921295,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1424.254,
            817.208
          ],
          [
            1526.254,
            817.208
          ],
          [
            1526.254,
            1046.208
          ],
          [
            1424.254,
            1046.208
          ]
        ]
      ]
    },
    {
      "id": "walls-426",
      "label": "426 Accessible king studio gross wall faces",
      "quantity": 99.20219446800674,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1424.254,
            817.208
          ],
          [
            1526.254,
            817.208
          ],
          [
            1526.254,
            1046.208
          ],
          [
            1424.254,
            1046.208
          ]
        ]
      ]
    },
    {
      "id": "room-433",
      "label": "433 Corridor floor / ceiling",
      "quantity": 804.8571663969564,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            324.254,
            781.208
          ],
          [
            1405.254,
            781.208
          ],
          [
            1405.254,
            753.208
          ],
          [
            1526.254,
            753.208
          ],
          [
            1526.254,
            808.208
          ],
          [
            324.254,
            808.208
          ]
        ]
      ]
    },
    {
      "id": "walls-433",
      "label": "433 Corridor gross wall faces",
      "quantity": 376.72857536641834,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            324.254,
            781.208
          ],
          [
            1405.254,
            781.208
          ],
          [
            1405.254,
            753.208
          ],
          [
            1526.254,
            753.208
          ],
          [
            1526.254,
            808.208
          ],
          [
            324.254,
            808.208
          ]
        ]
      ]
    },
    {
      "id": "room-EL",
      "label": "EL Elevator core \u00b7 floor 4 floor / ceiling",
      "quantity": 99.43383552273096,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Floor-level core footprint; carries no finished-floor or ceiling assignment. Reconcile stair landings / shaft openings with details.",
      "polygons": [
        [
          [
            1423.254,
            630.208
          ],
          [
            1464.254,
            630.208
          ],
          [
            1464.254,
            738.208
          ],
          [
            1423.254,
            738.208
          ]
        ]
      ]
    },
    {
      "id": "walls-EL",
      "label": "EL Elevator core \u00b7 floor 4 gross wall faces",
      "quantity": 44.65597273635348,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Floor-level core footprint; carries no finished-floor or ceiling assignment. Reconcile stair landings / shaft openings with details.",
      "polygons": [
        [
          [
            1423.254,
            630.208
          ],
          [
            1464.254,
            630.208
          ],
          [
            1464.254,
            738.208
          ],
          [
            1423.254,
            738.208
          ]
        ]
      ]
    },
    {
      "id": "bath-401",
      "label": "401 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            324.254,
            722.208
          ],
          [
            365.254,
            722.208
          ],
          [
            365.254,
            772.208
          ],
          [
            324.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-401",
      "label": "401 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            324.254,
            722.208
          ],
          [
            365.254,
            722.208
          ],
          [
            365.254,
            772.208
          ],
          [
            324.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "main-401",
      "label": "401 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            324.254,
            582.208
          ],
          [
            399.254,
            582.208
          ],
          [
            399.254,
            772.208
          ],
          [
            324.254,
            772.208
          ]
        ],
        [
          [
            324.254,
            722.208
          ],
          [
            365.254,
            722.208
          ],
          [
            365.254,
            772.208
          ],
          [
            324.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "bath-403",
      "label": "403 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            444.254,
            722.208
          ],
          [
            485.254,
            722.208
          ],
          [
            485.254,
            772.208
          ],
          [
            444.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-403",
      "label": "403 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            444.254,
            722.208
          ],
          [
            485.254,
            722.208
          ],
          [
            485.254,
            772.208
          ],
          [
            444.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "main-403",
      "label": "403 room outside bathroom",
      "quantity": 282.49269441643077,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            408.254,
            582.208
          ],
          [
            485.254,
            582.208
          ],
          [
            485.254,
            772.208
          ],
          [
            408.254,
            772.208
          ]
        ],
        [
          [
            444.254,
            722.208
          ],
          [
            485.254,
            722.208
          ],
          [
            485.254,
            772.208
          ],
          [
            444.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "bath-405",
      "label": "405 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            494.254,
            722.208
          ],
          [
            535.254,
            722.208
          ],
          [
            535.254,
            772.208
          ],
          [
            494.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-405",
      "label": "405 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            494.254,
            722.208
          ],
          [
            535.254,
            722.208
          ],
          [
            535.254,
            772.208
          ],
          [
            494.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "main-405",
      "label": "405 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            494.254,
            582.208
          ],
          [
            569.254,
            582.208
          ],
          [
            569.254,
            772.208
          ],
          [
            494.254,
            772.208
          ]
        ],
        [
          [
            494.254,
            722.208
          ],
          [
            535.254,
            722.208
          ],
          [
            535.254,
            772.208
          ],
          [
            494.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "bath-409",
      "label": "409 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            782.254,
            722.208
          ],
          [
            823.254,
            722.208
          ],
          [
            823.254,
            772.208
          ],
          [
            782.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-409",
      "label": "409 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            782.254,
            722.208
          ],
          [
            823.254,
            722.208
          ],
          [
            823.254,
            772.208
          ],
          [
            782.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "main-409",
      "label": "409 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            748.254,
            582.208
          ],
          [
            823.254,
            582.208
          ],
          [
            823.254,
            772.208
          ],
          [
            748.254,
            772.208
          ]
        ],
        [
          [
            782.254,
            722.208
          ],
          [
            823.254,
            722.208
          ],
          [
            823.254,
            772.208
          ],
          [
            782.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "bath-411",
      "label": "411 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            832.254,
            722.208
          ],
          [
            873.254,
            722.208
          ],
          [
            873.254,
            772.208
          ],
          [
            832.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-411",
      "label": "411 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            832.254,
            722.208
          ],
          [
            873.254,
            722.208
          ],
          [
            873.254,
            772.208
          ],
          [
            832.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "main-411",
      "label": "411 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            832.254,
            582.208
          ],
          [
            907.254,
            582.208
          ],
          [
            907.254,
            772.208
          ],
          [
            832.254,
            772.208
          ]
        ],
        [
          [
            832.254,
            722.208
          ],
          [
            873.254,
            722.208
          ],
          [
            873.254,
            772.208
          ],
          [
            832.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "bath-413",
      "label": "413 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            951.254,
            722.208
          ],
          [
            992.254,
            722.208
          ],
          [
            992.254,
            772.208
          ],
          [
            951.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-413",
      "label": "413 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            951.254,
            722.208
          ],
          [
            992.254,
            722.208
          ],
          [
            992.254,
            772.208
          ],
          [
            951.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "main-413",
      "label": "413 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            917.254,
            582.208
          ],
          [
            992.254,
            582.208
          ],
          [
            992.254,
            772.208
          ],
          [
            917.254,
            772.208
          ]
        ],
        [
          [
            951.254,
            722.208
          ],
          [
            992.254,
            722.208
          ],
          [
            992.254,
            772.208
          ],
          [
            951.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "bath-415",
      "label": "415 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1001.254,
            722.208
          ],
          [
            1042.254,
            722.208
          ],
          [
            1042.254,
            772.208
          ],
          [
            1001.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-415",
      "label": "415 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1001.254,
            722.208
          ],
          [
            1042.254,
            722.208
          ],
          [
            1042.254,
            772.208
          ],
          [
            1001.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "main-415",
      "label": "415 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1001.254,
            582.208
          ],
          [
            1076.254,
            582.208
          ],
          [
            1076.254,
            772.208
          ],
          [
            1001.254,
            772.208
          ]
        ],
        [
          [
            1001.254,
            722.208
          ],
          [
            1042.254,
            722.208
          ],
          [
            1042.254,
            772.208
          ],
          [
            1001.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "bath-417",
      "label": "417 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1120.254,
            722.208
          ],
          [
            1161.254,
            722.208
          ],
          [
            1161.254,
            772.208
          ],
          [
            1120.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-417",
      "label": "417 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1120.254,
            722.208
          ],
          [
            1161.254,
            722.208
          ],
          [
            1161.254,
            772.208
          ],
          [
            1120.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "main-417",
      "label": "417 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1086.254,
            582.208
          ],
          [
            1161.254,
            582.208
          ],
          [
            1161.254,
            772.208
          ],
          [
            1086.254,
            772.208
          ]
        ],
        [
          [
            1120.254,
            722.208
          ],
          [
            1161.254,
            722.208
          ],
          [
            1161.254,
            772.208
          ],
          [
            1120.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "bath-419",
      "label": "419 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1170.254,
            722.208
          ],
          [
            1211.254,
            722.208
          ],
          [
            1211.254,
            772.208
          ],
          [
            1170.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-419",
      "label": "419 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1170.254,
            722.208
          ],
          [
            1211.254,
            722.208
          ],
          [
            1211.254,
            772.208
          ],
          [
            1170.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "main-419",
      "label": "419 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1170.254,
            582.208
          ],
          [
            1245.254,
            582.208
          ],
          [
            1245.254,
            772.208
          ],
          [
            1170.254,
            772.208
          ]
        ],
        [
          [
            1170.254,
            722.208
          ],
          [
            1211.254,
            722.208
          ],
          [
            1211.254,
            772.208
          ],
          [
            1170.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "bath-421",
      "label": "421 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1289.254,
            722.208
          ],
          [
            1330.254,
            722.208
          ],
          [
            1330.254,
            772.208
          ],
          [
            1289.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-421",
      "label": "421 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1289.254,
            722.208
          ],
          [
            1330.254,
            722.208
          ],
          [
            1330.254,
            772.208
          ],
          [
            1289.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "main-421",
      "label": "421 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1255.254,
            582.208
          ],
          [
            1330.254,
            582.208
          ],
          [
            1330.254,
            772.208
          ],
          [
            1255.254,
            772.208
          ]
        ],
        [
          [
            1289.254,
            722.208
          ],
          [
            1330.254,
            722.208
          ],
          [
            1330.254,
            772.208
          ],
          [
            1289.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "bath-404",
      "label": "404 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            494.254,
            817.208
          ],
          [
            535.254,
            817.208
          ],
          [
            535.254,
            871.208
          ],
          [
            494.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-404",
      "label": "404 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            494.254,
            817.208
          ],
          [
            535.254,
            817.208
          ],
          [
            535.254,
            871.208
          ],
          [
            494.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "main-404",
      "label": "404 room outside bathroom",
      "quantity": 268.5926166864013,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            494.254,
            817.208
          ],
          [
            569.254,
            817.208
          ],
          [
            569.254,
            1006.208
          ],
          [
            494.254,
            1006.208
          ]
        ],
        [
          [
            494.254,
            817.208
          ],
          [
            535.254,
            817.208
          ],
          [
            535.254,
            871.208
          ],
          [
            494.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "bath-406",
      "label": "406 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            613.254,
            817.208
          ],
          [
            654.254,
            817.208
          ],
          [
            654.254,
            871.208
          ],
          [
            613.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-406",
      "label": "406 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            613.254,
            817.208
          ],
          [
            654.254,
            817.208
          ],
          [
            654.254,
            871.208
          ],
          [
            613.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "main-406",
      "label": "406 room outside bathroom",
      "quantity": 272.83674381237154,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            578.254,
            817.208
          ],
          [
            654.254,
            817.208
          ],
          [
            654.254,
            1006.208
          ],
          [
            578.254,
            1006.208
          ]
        ],
        [
          [
            613.254,
            817.208
          ],
          [
            654.254,
            817.208
          ],
          [
            654.254,
            871.208
          ],
          [
            613.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "bath-408",
      "label": "408 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            663.254,
            817.208
          ],
          [
            704.254,
            817.208
          ],
          [
            704.254,
            871.208
          ],
          [
            663.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-408",
      "label": "408 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            663.254,
            817.208
          ],
          [
            704.254,
            817.208
          ],
          [
            704.254,
            871.208
          ],
          [
            663.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "main-408",
      "label": "408 room outside bathroom",
      "quantity": 272.83674381237154,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            663.254,
            817.208
          ],
          [
            739.254,
            817.208
          ],
          [
            739.254,
            1006.208
          ],
          [
            663.254,
            1006.208
          ]
        ],
        [
          [
            663.254,
            817.208
          ],
          [
            704.254,
            817.208
          ],
          [
            704.254,
            871.208
          ],
          [
            663.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "bath-410",
      "label": "410 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            782.254,
            817.208
          ],
          [
            823.254,
            817.208
          ],
          [
            823.254,
            871.208
          ],
          [
            782.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-410",
      "label": "410 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            782.254,
            817.208
          ],
          [
            823.254,
            817.208
          ],
          [
            823.254,
            871.208
          ],
          [
            782.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "main-410",
      "label": "410 room outside bathroom",
      "quantity": 268.5926166864013,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            748.254,
            817.208
          ],
          [
            823.254,
            817.208
          ],
          [
            823.254,
            1006.208
          ],
          [
            748.254,
            1006.208
          ]
        ],
        [
          [
            782.254,
            817.208
          ],
          [
            823.254,
            817.208
          ],
          [
            823.254,
            871.208
          ],
          [
            782.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "bath-412",
      "label": "412 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            832.254,
            817.208
          ],
          [
            873.254,
            817.208
          ],
          [
            873.254,
            871.208
          ],
          [
            832.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-412",
      "label": "412 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            832.254,
            817.208
          ],
          [
            873.254,
            817.208
          ],
          [
            873.254,
            871.208
          ],
          [
            832.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "main-412",
      "label": "412 room outside bathroom",
      "quantity": 268.5926166864013,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            832.254,
            817.208
          ],
          [
            907.254,
            817.208
          ],
          [
            907.254,
            1006.208
          ],
          [
            832.254,
            1006.208
          ]
        ],
        [
          [
            832.254,
            817.208
          ],
          [
            873.254,
            817.208
          ],
          [
            873.254,
            871.208
          ],
          [
            832.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "bath-414",
      "label": "414 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            951.254,
            817.208
          ],
          [
            992.254,
            817.208
          ],
          [
            992.254,
            871.208
          ],
          [
            951.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-414",
      "label": "414 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            951.254,
            817.208
          ],
          [
            992.254,
            817.208
          ],
          [
            992.254,
            871.208
          ],
          [
            951.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "main-414",
      "label": "414 room outside bathroom",
      "quantity": 268.5926166864013,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            917.254,
            817.208
          ],
          [
            992.254,
            817.208
          ],
          [
            992.254,
            1006.208
          ],
          [
            917.254,
            1006.208
          ]
        ],
        [
          [
            951.254,
            817.208
          ],
          [
            992.254,
            817.208
          ],
          [
            992.254,
            871.208
          ],
          [
            951.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "bath-416",
      "label": "416 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1035.254,
            817.208
          ],
          [
            1076.254,
            817.208
          ],
          [
            1076.254,
            871.208
          ],
          [
            1035.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-416",
      "label": "416 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1035.254,
            817.208
          ],
          [
            1076.254,
            817.208
          ],
          [
            1076.254,
            871.208
          ],
          [
            1035.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "main-416",
      "label": "416 room outside bathroom",
      "quantity": 330.81735883488534,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1002.254,
            817.208
          ],
          [
            1076.254,
            817.208
          ],
          [
            1076.254,
            1046.208
          ],
          [
            1002.254,
            1046.208
          ]
        ],
        [
          [
            1035.254,
            817.208
          ],
          [
            1076.254,
            817.208
          ],
          [
            1076.254,
            871.208
          ],
          [
            1035.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "bath-418",
      "label": "418 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1086.254,
            817.208
          ],
          [
            1127.254,
            817.208
          ],
          [
            1127.254,
            871.208
          ],
          [
            1086.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-418",
      "label": "418 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1086.254,
            817.208
          ],
          [
            1127.254,
            817.208
          ],
          [
            1127.254,
            871.208
          ],
          [
            1086.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "main-418",
      "label": "418 room outside bathroom",
      "quantity": 335.9597139240239,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1086.254,
            817.208
          ],
          [
            1161.254,
            817.208
          ],
          [
            1161.254,
            1046.208
          ],
          [
            1086.254,
            1046.208
          ]
        ],
        [
          [
            1086.254,
            817.208
          ],
          [
            1127.254,
            817.208
          ],
          [
            1127.254,
            871.208
          ],
          [
            1086.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "bath-420",
      "label": "420 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1204.254,
            817.208
          ],
          [
            1245.254,
            817.208
          ],
          [
            1245.254,
            871.208
          ],
          [
            1204.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-420",
      "label": "420 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1204.254,
            817.208
          ],
          [
            1245.254,
            817.208
          ],
          [
            1245.254,
            871.208
          ],
          [
            1204.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "main-420",
      "label": "420 room outside bathroom",
      "quantity": 335.9597139240239,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1170.254,
            817.208
          ],
          [
            1245.254,
            817.208
          ],
          [
            1245.254,
            1046.208
          ],
          [
            1170.254,
            1046.208
          ]
        ],
        [
          [
            1204.254,
            817.208
          ],
          [
            1245.254,
            817.208
          ],
          [
            1245.254,
            871.208
          ],
          [
            1204.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "bath-422",
      "label": "422 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1255.254,
            817.208
          ],
          [
            1296.254,
            817.208
          ],
          [
            1296.254,
            871.208
          ],
          [
            1255.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-422",
      "label": "422 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1255.254,
            817.208
          ],
          [
            1296.254,
            817.208
          ],
          [
            1296.254,
            871.208
          ],
          [
            1255.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "main-422",
      "label": "422 room outside bathroom",
      "quantity": 335.9597139240239,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1255.254,
            817.208
          ],
          [
            1330.254,
            817.208
          ],
          [
            1330.254,
            1046.208
          ],
          [
            1255.254,
            1046.208
          ]
        ],
        [
          [
            1255.254,
            817.208
          ],
          [
            1296.254,
            817.208
          ],
          [
            1296.254,
            871.208
          ],
          [
            1255.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "bath-424",
      "label": "424 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1373.254,
            817.208
          ],
          [
            1414.254,
            817.208
          ],
          [
            1414.254,
            871.208
          ],
          [
            1373.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-424",
      "label": "424 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1373.254,
            817.208
          ],
          [
            1414.254,
            817.208
          ],
          [
            1414.254,
            871.208
          ],
          [
            1373.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "main-424",
      "label": "424 room outside bathroom",
      "quantity": 330.81735883488534,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1340.254,
            817.208
          ],
          [
            1414.254,
            817.208
          ],
          [
            1414.254,
            1046.208
          ],
          [
            1340.254,
            1046.208
          ]
        ],
        [
          [
            1373.254,
            817.208
          ],
          [
            1414.254,
            817.208
          ],
          [
            1414.254,
            871.208
          ],
          [
            1373.254,
            871.208
          ]
        ]
      ]
    },
    {
      "id": "bath-407",
      "label": "407 bathroom zone",
      "quantity": 87.0382896310084,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            663.254,
            721.208
          ],
          [
            739.254,
            721.208
          ],
          [
            739.254,
            772.208
          ],
          [
            663.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-407",
      "label": "407 bathroom wall faces",
      "quantity": 38.06247340615364,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            663.254,
            721.208
          ],
          [
            739.254,
            721.208
          ],
          [
            739.254,
            772.208
          ],
          [
            663.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "main-407",
      "label": "407 room outside bathroom",
      "quantity": 469.86304753333843,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            579.254,
            617.208
          ],
          [
            739.254,
            617.208
          ],
          [
            739.254,
            772.208
          ],
          [
            579.254,
            772.208
          ]
        ],
        [
          [
            663.254,
            721.208
          ],
          [
            739.254,
            721.208
          ],
          [
            739.254,
            772.208
          ],
          [
            663.254,
            772.208
          ]
        ]
      ]
    },
    {
      "id": "bath-402",
      "label": "402 bathroom zone",
      "quantity": 68.13059100631565,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            324.254,
            878.208
          ],
          [
            398.254,
            878.208
          ],
          [
            398.254,
            919.208
          ],
          [
            324.254,
            919.208
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-402",
      "label": "402 bathroom wall faces",
      "quantity": 34.46601922604464,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            324.254,
            878.208
          ],
          [
            398.254,
            878.208
          ],
          [
            398.254,
            919.208
          ],
          [
            324.254,
            919.208
          ]
        ]
      ]
    },
    {
      "id": "main-402",
      "label": "402 room outside bathroom",
      "quantity": 449.2936271767843,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            324.254,
            878.208
          ],
          [
            442.254,
            878.208
          ],
          [
            442.254,
            817.208
          ],
          [
            484.254,
            817.208
          ],
          [
            484.254,
            1006.208
          ],
          [
            324.254,
            1006.208
          ]
        ],
        [
          [
            324.254,
            878.208
          ],
          [
            398.254,
            878.208
          ],
          [
            398.254,
            919.208
          ],
          [
            324.254,
            919.208
          ]
        ]
      ]
    },
    {
      "id": "bath-426",
      "label": "426 bathroom zone",
      "quantity": 67.83866691828595,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1469.254,
            817.208
          ],
          [
            1526.254,
            817.208
          ],
          [
            1526.254,
            870.208
          ],
          [
            1469.254,
            870.208
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-426",
      "label": "426 bathroom wall faces",
      "quantity": 32.967496650999216,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1469.254,
            817.208
          ],
          [
            1526.254,
            817.208
          ],
          [
            1526.254,
            870.208
          ],
          [
            1469.254,
            870.208
          ]
        ]
      ]
    },
    {
      "id": "main-426",
      "label": "426 room outside bathroom",
      "quantity": 456.68155217384356,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1424.254,
            817.208
          ],
          [
            1526.254,
            817.208
          ],
          [
            1526.254,
            1046.208
          ],
          [
            1424.254,
            1046.208
          ]
        ],
        [
          [
            1469.254,
            817.208
          ],
          [
            1526.254,
            817.208
          ],
          [
            1526.254,
            870.208
          ],
          [
            1469.254,
            870.208
          ]
        ]
      ]
    }
  ],
  "roomRegister": [
    {
      "id": "001",
      "name": "East Stair 1 \u00b7 floor 4",
      "kind": "stair",
      "polygon": [
        [
          1474.254,
          630.208
        ],
        [
          1526.254,
          630.208
        ],
        [
          1526.254,
          741.208
        ],
        [
          1474.254,
          741.208
        ]
      ],
      "floorFootprintSF": 129.6142950851859,
      "ceilingFootprintSF": 129.6142950851859,
      "grossWallFaceRunLF": 48.85183594648066,
      "scopeKey": "bradenton/floor4/room001",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "002",
      "name": "West Stair 2 \u00b7 floor 4",
      "kind": "stair",
      "polygon": [
        [
          324.254,
          817.208
        ],
        [
          438.254,
          817.208
        ],
        [
          438.254,
          869.208
        ],
        [
          324.254,
          869.208
        ]
      ],
      "floorFootprintSF": 133.11738414154226,
      "ceilingFootprintSF": 133.11738414154226,
      "grossWallFaceRunLF": 49.75094949150791,
      "scopeKey": "bradenton/floor4/room002",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "400",
      "name": "Elevator lobby",
      "kind": "enclosed",
      "polygon": [
        [
          1340.254,
          637.208
        ],
        [
          1415.254,
          637.208
        ],
        [
          1415.254,
          727.208
        ],
        [
          1399.254,
          727.208
        ],
        [
          1399.254,
          772.208
        ],
        [
          1340.254,
          772.208
        ]
      ],
      "floorFootprintSF": 211.19584983994685,
      "ceilingFootprintSF": 211.19584983994685,
      "grossWallFaceRunLF": 62.9379481519076,
      "scopeKey": "bradenton/floor4/room400",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "401",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          324.254,
          582.208
        ],
        [
          399.254,
          582.208
        ],
        [
          399.254,
          772.208
        ],
        [
          324.254,
          772.208
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor4/room401",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "402",
      "name": "King one-bedroom",
      "kind": "enclosed",
      "polygon": [
        [
          324.254,
          878.208
        ],
        [
          442.254,
          878.208
        ],
        [
          442.254,
          817.208
        ],
        [
          484.254,
          817.208
        ],
        [
          484.254,
          1006.208
        ],
        [
          324.254,
          1006.208
        ]
      ],
      "floorFootprintSF": 517.4242181830999,
      "ceilingFootprintSF": 517.4242181830999,
      "grossWallFaceRunLF": 104.59687573817024,
      "scopeKey": "bradenton/floor4/room402",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "403",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          408.254,
          582.208
        ],
        [
          485.254,
          582.208
        ],
        [
          485.254,
          772.208
        ],
        [
          408.254,
          772.208
        ]
      ],
      "floorFootprintSF": 328.5268775288062,
      "ceilingFootprintSF": 328.5268775288062,
      "grossWallFaceRunLF": 80.02110550742537,
      "scopeKey": "bradenton/floor4/room403",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "404",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          494.254,
          817.208
        ],
        [
          569.254,
          817.208
        ],
        [
          569.254,
          1006.208
        ],
        [
          494.254,
          1006.208
        ]
      ],
      "floorFootprintSF": 318.3095344477668,
      "ceilingFootprintSF": 318.3095344477668,
      "grossWallFaceRunLF": 79.12199196239813,
      "scopeKey": "bradenton/floor4/room404",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "405",
      "name": "Connecting king studio",
      "kind": "enclosed",
      "polygon": [
        [
          494.254,
          582.208
        ],
        [
          569.254,
          582.208
        ],
        [
          569.254,
          772.208
        ],
        [
          494.254,
          772.208
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor4/room405",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "406",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          578.254,
          817.208
        ],
        [
          654.254,
          817.208
        ],
        [
          654.254,
          1006.208
        ],
        [
          578.254,
          1006.208
        ]
      ],
      "floorFootprintSF": 322.55366157373703,
      "ceilingFootprintSF": 322.55366157373703,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor4/room406",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "407",
      "name": "Accessible king one-bedroom",
      "kind": "enclosed",
      "polygon": [
        [
          579.254,
          617.208
        ],
        [
          739.254,
          617.208
        ],
        [
          739.254,
          772.208
        ],
        [
          579.254,
          772.208
        ]
      ],
      "floorFootprintSF": 556.9013371643468,
      "ceilingFootprintSF": 556.9013371643468,
      "grossWallFaceRunLF": 94.4069222278614,
      "scopeKey": "bradenton/floor4/room407",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "408",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          663.254,
          817.208
        ],
        [
          739.254,
          817.208
        ],
        [
          739.254,
          1006.208
        ],
        [
          663.254,
          1006.208
        ]
      ],
      "floorFootprintSF": 322.55366157373703,
      "ceilingFootprintSF": 322.55366157373703,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor4/room408",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "409",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          748.254,
          582.208
        ],
        [
          823.254,
          582.208
        ],
        [
          823.254,
          772.208
        ],
        [
          748.254,
          772.208
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor4/room409",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "410",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          748.254,
          817.208
        ],
        [
          823.254,
          817.208
        ],
        [
          823.254,
          1006.208
        ],
        [
          748.254,
          1006.208
        ]
      ],
      "floorFootprintSF": 318.3095344477668,
      "ceilingFootprintSF": 318.3095344477668,
      "grossWallFaceRunLF": 79.12199196239813,
      "scopeKey": "bradenton/floor4/room410",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "411",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          832.254,
          582.208
        ],
        [
          907.254,
          582.208
        ],
        [
          907.254,
          772.208
        ],
        [
          832.254,
          772.208
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor4/room411",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "412",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          832.254,
          817.208
        ],
        [
          907.254,
          817.208
        ],
        [
          907.254,
          1006.208
        ],
        [
          832.254,
          1006.208
        ]
      ],
      "floorFootprintSF": 318.3095344477668,
      "ceilingFootprintSF": 318.3095344477668,
      "grossWallFaceRunLF": 79.12199196239813,
      "scopeKey": "bradenton/floor4/room412",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "413",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          917.254,
          582.208
        ],
        [
          992.254,
          582.208
        ],
        [
          992.254,
          772.208
        ],
        [
          917.254,
          772.208
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor4/room413",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "414",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          917.254,
          817.208
        ],
        [
          992.254,
          817.208
        ],
        [
          992.254,
          1006.208
        ],
        [
          917.254,
          1006.208
        ]
      ],
      "floorFootprintSF": 318.3095344477668,
      "ceilingFootprintSF": 318.3095344477668,
      "grossWallFaceRunLF": 79.12199196239813,
      "scopeKey": "bradenton/floor4/room414",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "415",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          1001.254,
          582.208
        ],
        [
          1076.254,
          582.208
        ],
        [
          1076.254,
          772.208
        ],
        [
          1001.254,
          772.208
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor4/room415",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "416",
      "name": "Queen / queen",
      "kind": "enclosed",
      "polygon": [
        [
          1002.254,
          817.208
        ],
        [
          1076.254,
          817.208
        ],
        [
          1076.254,
          1046.208
        ],
        [
          1002.254,
          1046.208
        ]
      ],
      "floorFootprintSF": 380.53427659625083,
      "ceilingFootprintSF": 380.53427659625083,
      "grossWallFaceRunLF": 90.8104680477524,
      "scopeKey": "bradenton/floor4/room416",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "417",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          1086.254,
          582.208
        ],
        [
          1161.254,
          582.208
        ],
        [
          1161.254,
          772.208
        ],
        [
          1086.254,
          772.208
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor4/room417",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "418",
      "name": "Queen / queen",
      "kind": "enclosed",
      "polygon": [
        [
          1086.254,
          817.208
        ],
        [
          1161.254,
          817.208
        ],
        [
          1161.254,
          1046.208
        ],
        [
          1086.254,
          1046.208
        ]
      ],
      "floorFootprintSF": 385.6766316853894,
      "ceilingFootprintSF": 385.6766316853894,
      "grossWallFaceRunLF": 91.11017256276148,
      "scopeKey": "bradenton/floor4/room418",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "419",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          1170.254,
          582.208
        ],
        [
          1245.254,
          582.208
        ],
        [
          1245.254,
          772.208
        ],
        [
          1170.254,
          772.208
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor4/room419",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "420",
      "name": "Queen / queen",
      "kind": "enclosed",
      "polygon": [
        [
          1170.254,
          817.208
        ],
        [
          1245.254,
          817.208
        ],
        [
          1245.254,
          1046.208
        ],
        [
          1170.254,
          1046.208
        ]
      ],
      "floorFootprintSF": 385.6766316853894,
      "ceilingFootprintSF": 385.6766316853894,
      "grossWallFaceRunLF": 91.11017256276148,
      "scopeKey": "bradenton/floor4/room420",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "421",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          1255.254,
          582.208
        ],
        [
          1330.254,
          582.208
        ],
        [
          1330.254,
          772.208
        ],
        [
          1255.254,
          772.208
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor4/room421",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "422",
      "name": "Queen / queen",
      "kind": "enclosed",
      "polygon": [
        [
          1255.254,
          817.208
        ],
        [
          1330.254,
          817.208
        ],
        [
          1330.254,
          1046.208
        ],
        [
          1255.254,
          1046.208
        ]
      ],
      "floorFootprintSF": 385.6766316853894,
      "ceilingFootprintSF": 385.6766316853894,
      "grossWallFaceRunLF": 91.11017256276148,
      "scopeKey": "bradenton/floor4/room422",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "423",
      "name": "Storage",
      "kind": "enclosed",
      "polygon": [
        [
          1340.254,
          582.208
        ],
        [
          1357.254,
          582.208
        ],
        [
          1357.254,
          603.208
        ],
        [
          1415.254,
          603.208
        ],
        [
          1415.254,
          632.208
        ],
        [
          1340.254,
          632.208
        ]
      ],
      "floorFootprintSF": 56.857830068553476,
      "ceilingFootprintSF": 56.857830068553476,
      "grossWallFaceRunLF": 37.46306437613548,
      "scopeKey": "bradenton/floor4/room423",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "424",
      "name": "Connecting queen / queen",
      "kind": "enclosed",
      "polygon": [
        [
          1340.254,
          817.208
        ],
        [
          1414.254,
          817.208
        ],
        [
          1414.254,
          1046.208
        ],
        [
          1340.254,
          1046.208
        ]
      ],
      "floorFootprintSF": 380.53427659625083,
      "ceilingFootprintSF": 380.53427659625083,
      "grossWallFaceRunLF": 90.8104680477524,
      "scopeKey": "bradenton/floor4/room424",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "426",
      "name": "Accessible king studio",
      "kind": "enclosed",
      "polygon": [
        [
          1424.254,
          817.208
        ],
        [
          1526.254,
          817.208
        ],
        [
          1526.254,
          1046.208
        ],
        [
          1424.254,
          1046.208
        ]
      ],
      "floorFootprintSF": 524.5202190921295,
      "ceilingFootprintSF": 524.5202190921295,
      "grossWallFaceRunLF": 99.20219446800674,
      "scopeKey": "bradenton/floor4/room426",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "433",
      "name": "Corridor",
      "kind": "enclosed",
      "polygon": [
        [
          324.254,
          781.208
        ],
        [
          1405.254,
          781.208
        ],
        [
          1405.254,
          753.208
        ],
        [
          1526.254,
          753.208
        ],
        [
          1526.254,
          808.208
        ],
        [
          324.254,
          808.208
        ]
      ],
      "floorFootprintSF": 804.8571663969564,
      "ceilingFootprintSF": 804.8571663969564,
      "grossWallFaceRunLF": 376.72857536641834,
      "scopeKey": "bradenton/floor4/room433",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "EL",
      "name": "Elevator core \u00b7 floor 4",
      "kind": "shaft",
      "polygon": [
        [
          1423.254,
          630.208
        ],
        [
          1464.254,
          630.208
        ],
        [
          1464.254,
          738.208
        ],
        [
          1423.254,
          738.208
        ]
      ],
      "floorFootprintSF": 99.43383552273096,
      "ceilingFootprintSF": 99.43383552273096,
      "grossWallFaceRunLF": 44.65597273635348,
      "scopeKey": "bradenton/floor4/roomEL",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    }
  ],
  "bathroomZones": [
    {
      "room": "401",
      "polygon": [
        [
          324.254,
          722.208
        ],
        [
          365.254,
          722.208
        ],
        [
          365.254,
          772.208
        ],
        [
          324.254,
          772.208
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "403",
      "polygon": [
        [
          444.254,
          722.208
        ],
        [
          485.254,
          722.208
        ],
        [
          485.254,
          772.208
        ],
        [
          444.254,
          772.208
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "405",
      "polygon": [
        [
          494.254,
          722.208
        ],
        [
          535.254,
          722.208
        ],
        [
          535.254,
          772.208
        ],
        [
          494.254,
          772.208
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "409",
      "polygon": [
        [
          782.254,
          722.208
        ],
        [
          823.254,
          722.208
        ],
        [
          823.254,
          772.208
        ],
        [
          782.254,
          772.208
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "411",
      "polygon": [
        [
          832.254,
          722.208
        ],
        [
          873.254,
          722.208
        ],
        [
          873.254,
          772.208
        ],
        [
          832.254,
          772.208
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "413",
      "polygon": [
        [
          951.254,
          722.208
        ],
        [
          992.254,
          722.208
        ],
        [
          992.254,
          772.208
        ],
        [
          951.254,
          772.208
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "415",
      "polygon": [
        [
          1001.254,
          722.208
        ],
        [
          1042.254,
          722.208
        ],
        [
          1042.254,
          772.208
        ],
        [
          1001.254,
          772.208
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "417",
      "polygon": [
        [
          1120.254,
          722.208
        ],
        [
          1161.254,
          722.208
        ],
        [
          1161.254,
          772.208
        ],
        [
          1120.254,
          772.208
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "419",
      "polygon": [
        [
          1170.254,
          722.208
        ],
        [
          1211.254,
          722.208
        ],
        [
          1211.254,
          772.208
        ],
        [
          1170.254,
          772.208
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "421",
      "polygon": [
        [
          1289.254,
          722.208
        ],
        [
          1330.254,
          722.208
        ],
        [
          1330.254,
          772.208
        ],
        [
          1289.254,
          772.208
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "404",
      "polygon": [
        [
          494.254,
          817.208
        ],
        [
          535.254,
          817.208
        ],
        [
          535.254,
          871.208
        ],
        [
          494.254,
          871.208
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "406",
      "polygon": [
        [
          613.254,
          817.208
        ],
        [
          654.254,
          817.208
        ],
        [
          654.254,
          871.208
        ],
        [
          613.254,
          871.208
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "408",
      "polygon": [
        [
          663.254,
          817.208
        ],
        [
          704.254,
          817.208
        ],
        [
          704.254,
          871.208
        ],
        [
          663.254,
          871.208
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "410",
      "polygon": [
        [
          782.254,
          817.208
        ],
        [
          823.254,
          817.208
        ],
        [
          823.254,
          871.208
        ],
        [
          782.254,
          871.208
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "412",
      "polygon": [
        [
          832.254,
          817.208
        ],
        [
          873.254,
          817.208
        ],
        [
          873.254,
          871.208
        ],
        [
          832.254,
          871.208
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "414",
      "polygon": [
        [
          951.254,
          817.208
        ],
        [
          992.254,
          817.208
        ],
        [
          992.254,
          871.208
        ],
        [
          951.254,
          871.208
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "416",
      "polygon": [
        [
          1035.254,
          817.208
        ],
        [
          1076.254,
          817.208
        ],
        [
          1076.254,
          871.208
        ],
        [
          1035.254,
          871.208
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "418",
      "polygon": [
        [
          1086.254,
          817.208
        ],
        [
          1127.254,
          817.208
        ],
        [
          1127.254,
          871.208
        ],
        [
          1086.254,
          871.208
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "420",
      "polygon": [
        [
          1204.254,
          817.208
        ],
        [
          1245.254,
          817.208
        ],
        [
          1245.254,
          871.208
        ],
        [
          1204.254,
          871.208
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "422",
      "polygon": [
        [
          1255.254,
          817.208
        ],
        [
          1296.254,
          817.208
        ],
        [
          1296.254,
          871.208
        ],
        [
          1255.254,
          871.208
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "424",
      "polygon": [
        [
          1373.254,
          817.208
        ],
        [
          1414.254,
          817.208
        ],
        [
          1414.254,
          871.208
        ],
        [
          1373.254,
          871.208
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "407",
      "polygon": [
        [
          663.254,
          721.208
        ],
        [
          739.254,
          721.208
        ],
        [
          739.254,
          772.208
        ],
        [
          663.254,
          772.208
        ]
      ],
      "areaSF": 87.0382896310084
    },
    {
      "room": "402",
      "polygon": [
        [
          324.254,
          878.208
        ],
        [
          398.254,
          878.208
        ],
        [
          398.254,
          919.208
        ],
        [
          324.254,
          919.208
        ]
      ],
      "areaSF": 68.13059100631565
    },
    {
      "room": "426",
      "polygon": [
        [
          1469.254,
          817.208
        ],
        [
          1526.254,
          817.208
        ],
        [
          1526.254,
          870.208
        ],
        [
          1469.254,
          870.208
        ]
      ],
      "areaSF": 67.83866691828595
    }
  ],
  "wallAssignmentStatus": "No explicit W1\u2013W6 plan tags found. Keep exact assemblies unassigned while preserving separate corridor, party and exterior runs.",
  "reuseRule": "Room IDs are floor-qualified. Stair and elevator outlines continue building systems; do not create additional systems at every floor.",
  "measurementConfidence": "Approximate source traces registered to repeated floor geometry. Exact wall-type assignment, finish deductions, heights and structural opening limits remain identified coordination items."
}