  "sheet": "A2.3",
  "coordinateSpace": {
    "width": 1920,
    "height": 1280
  },
  "calibration": {
    "printedPlanScale": "1/8 inch = 1 foot",
    "pixelsPerFoot": 6.673234192251457,
    "basis": "36 x 24 inch PDF. Common structural grid 3\u20134 equals 84.528 normalized pixels and 12 feet 8 inches on A1.4; grid 4\u20135 independently repeats 84.528 pixels. Printed scale conversion differs by 0.10 percent.",
    "checks": [
      {
        "grid": "3\u20134",
        "pixels": 84.528,
        "feet": 12.666666666666666
      },
      {
        "grid": "4\u20135",
        "pixels": 84.528,
        "feet": 12.666666666666666
      }
    ],
    "registration": {
      "dx": -28.221268627025495,
      "dy": -2.865171151620416,
      "method": "Grid 3 horizontal registration and grid A vertical registration; grids 3\u20134 and 4\u20135 independently checked."
    }
  },
  "rows": [
    {
      "id": "gross-floor",
      "label": "Gross third-floor outline",
      "quantity": 12173.212015139325,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced main outline including walls and cores; small facade jogs simplified. Separate core deductions below.",
      "polygons": [
        [
          [
            318.779,
            546.135
          ],
          [
            574.779,
            546.135
          ],
          [
            574.779,
            584.135
          ],
          [
            747.779,
            584.135
          ],
          [
            747.779,
            546.135
          ],
          [
            1362.779,
            546.135
          ],
          [
            1362.779,
            569.135
          ],
          [
            1422.779,
            569.135
          ],
          [
            1422.779,
            596.135
          ],
          [
            1535.779,
            596.135
          ],
          [
            1535.779,
            1025.135
          ],
          [
            999.779,
            1025.135
          ],
          [
            999.779,
            985.135
          ],
          [
            318.779,
            985.135
          ]
        ]
      ]
    },
    {
      "id": "floor-deck",
      "label": "Floor deck \u00b7 core deductions",
      "quantity": 11811.046500389866,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Gross floor outline less two complete stair zones and elevator core. Stair landings and structural penetration limits require stair/structural details.",
      "polygons": [
        [
          [
            318.779,
            546.135
          ],
          [
            574.779,
            546.135
          ],
          [
            574.779,
            584.135
          ],
          [
            747.779,
            584.135
          ],
          [
            747.779,
            546.135
          ],
          [
            1362.779,
            546.135
          ],
          [
            1362.779,
            569.135
          ],
          [
            1422.779,
            569.135
          ],
          [
            1422.779,
            596.135
          ],
          [
            1535.779,
            596.135
          ],
          [
            1535.779,
            1025.135
          ],
          [
            999.779,
            1025.135
          ],
          [
            999.779,
            985.135
          ],
          [
            318.779,
            985.135
          ]
        ],
        [
          [
            1475.779,
            601.135
          ],
          [
            1527.779,
            601.135
          ],
          [
            1527.779,
            712.135
          ],
          [
            1475.779,
            712.135
          ]
        ],
        [
          [
            325.779,
            788.135
          ],
          [
            439.779,
            788.135
          ],
          [
            439.779,
            840.135
          ],
          [
            325.779,
            840.135
          ]
        ],
        [
          [
            1424.779,
            601.135
          ],
          [
            1465.779,
            601.135
          ],
          [
            1465.779,
            709.135
          ],
          [
            1424.779,
            709.135
          ]
        ]
      ]
    },
    {
      "id": "gypcrete",
      "label": "1\u00bd\u2033 gypcrete \u00b7 floor basis",
      "quantity": 54.68077083513827,
      "unit": "CY",
      "color": "#ba9138",
      "basis": "A0.2 UL L514 1\u00bd-inch gypcrete applied to traced deck basis excluding full stair zones and elevator core. Structural deck limits, wet-area buildup and waste to be resolved.",
      "polygons": [
        [
          [
            318.779,
            546.135
          ],
          [
            574.779,
            546.135
          ],
          [
            574.779,
            584.135
          ],
          [
            747.779,
            584.135
          ],
          [
            747.779,
            546.135
          ],
          [
            1362.779,
            546.135
          ],
          [
            1362.779,
            569.135
          ],
          [
            1422.779,
            569.135
          ],
          [
            1422.779,
            596.135
          ],
          [
            1535.779,
            596.135
          ],
          [
            1535.779,
            1025.135
          ],
          [
            999.779,
            1025.135
          ],
          [
            999.779,
            985.135
          ],
          [
            318.779,
            985.135
          ]
        ],
        [
          [
            1475.779,
            601.135
          ],
          [
            1527.779,
            601.135
          ],
          [
            1527.779,
            712.135
          ],
          [
            1475.779,
            712.135
          ]
        ],
        [
          [
            325.779,
            788.135
          ],
          [
            439.779,
            788.135
          ],
          [
            439.779,
            840.135
          ],
          [
            325.779,
            840.135
          ]
        ],
        [
          [
            1424.779,
            601.135
          ],
          [
            1465.779,
            601.135
          ],
          [
            1465.779,
            709.135
          ],
          [
            1424.779,
            709.135
          ]
        ]
      ]
    },
    {
      "id": "exterior",
      "label": "Exterior wall run \u00b7 gross",
      "quantity": 519.6876290257513,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Traced outer perimeter before glazing/opening deductions; wall type, heights and facade jogs to sections.",
      "polygons": [
        [
          [
            318.779,
            546.135
          ],
          [
            574.779,
            546.135
          ],
          [
            574.779,
            584.135
          ],
          [
            747.779,
            584.135
          ],
          [
            747.779,
            546.135
          ],
          [
            1362.779,
            546.135
          ],
          [
            1362.779,
            569.135
          ],
          [
            1422.779,
            569.135
          ],
          [
            1422.779,
            596.135
          ],
          [
            1535.779,
            596.135
          ],
          [
            1535.779,
            1025.135
          ],
          [
            999.779,
            1025.135
          ],
          [
            999.779,
            985.135
          ],
          [
            318.779,
            985.135
          ]
        ]
      ]
    },
    {
      "id": "corridor",
      "label": "Guest corridor wall runs",
      "quantity": 333.331361593103,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Two gross wall runs before door openings; north lobby opening omitted. Link exact W1-family assembly.",
      "lines": [
        [
          [
            322.479,
            747.235
          ],
          [
            1336.779,
            747.235
          ]
        ],
        [
          [
            322.479,
            783.935
          ],
          [
            1532.579,
            783.935
          ]
        ]
      ]
    },
    {
      "id": "party",
      "label": "Shared guestroom wall runs",
      "quantity": 671.443010200601,
      "unit": "LF",
      "color": "#cf4f62",
      "basis": "22 gross dividing-wall runs, each physical divider counted once. Connecting openings not deducted. Exact W3/W4 or other assignment awaits wall tags/sections.",
      "lines": [
        [
          [
            405.479,
            549.535
          ],
          [
            405.479,
            747.235
          ]
        ],
        [
          [
            491.479,
            549.535
          ],
          [
            491.479,
            747.235
          ]
        ],
        [
          [
            576.079,
            584.135
          ],
          [
            576.079,
            747.235
          ]
        ],
        [
          [
            745.079,
            584.135
          ],
          [
            745.079,
            747.235
          ]
        ],
        [
          [
            829.679,
            549.535
          ],
          [
            829.679,
            747.235
          ]
        ],
        [
          [
            914.179,
            549.535
          ],
          [
            914.179,
            747.235
          ]
        ],
        [
          [
            998.679,
            549.535
          ],
          [
            998.679,
            747.235
          ]
        ],
        [
          [
            1083.279,
            549.535
          ],
          [
            1083.279,
            747.235
          ]
        ],
        [
          [
            1167.779,
            549.535
          ],
          [
            1167.779,
            747.235
          ]
        ],
        [
          [
            1252.279,
            549.535
          ],
          [
            1252.279,
            747.235
          ]
        ],
        [
          [
            491.479,
            783.935
          ],
          [
            491.479,
            981.635
          ]
        ],
        [
          [
            576.079,
            783.935
          ],
          [
            576.079,
            981.635
          ]
        ],
        [
          [
            660.579,
            783.935
          ],
          [
            660.579,
            981.635
          ]
        ],
        [
          [
            745.079,
            783.935
          ],
          [
            745.079,
            981.635
          ]
        ],
        [
          [
            829.679,
            783.935
          ],
          [
            829.679,
            981.635
          ]
        ],
        [
          [
            914.179,
            783.935
          ],
          [
            914.179,
            981.635
          ]
        ],
        [
          [
            998.679,
            783.935
          ],
          [
            998.679,
            981.635
          ]
        ],
        [
          [
            1083.279,
            783.935
          ],
          [
            1083.279,
            1021.735
          ]
        ],
        [
          [
            1167.779,
            783.935
          ],
          [
            1167.779,
            1021.735
          ]
        ],
        [
          [
            1252.279,
            783.935
          ],
          [
            1252.279,
            1021.735
          ]
        ],
        [
          [
            1336.779,
            783.935
          ],
          [
            1336.779,
            1021.735
          ]
        ],
        [
          [
            1421.379,
            783.935
          ],
          [
            1421.379,
            1021.735
          ]
        ]
      ]
    },
    {
      "id": "room-001",
      "label": "001 East Stair 1 \u00b7 floor 3 floor / ceiling",
      "quantity": 129.6142950851859,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Floor-level core footprint; carries no finished-floor or ceiling assignment. Reconcile stair landings / shaft openings with details.",
      "polygons": [
        [
          [
            1475.779,
            601.135
          ],
          [
            1527.779,
            601.135
          ],
          [
            1527.779,
            712.135
          ],
          [
            1475.779,
            712.135
          ]
        ]
      ]
    },
    {
      "id": "walls-001",
      "label": "001 East Stair 1 \u00b7 floor 3 gross wall faces",
      "quantity": 48.85183594648066,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Floor-level core footprint; carries no finished-floor or ceiling assignment. Reconcile stair landings / shaft openings with details.",
      "polygons": [
        [
          [
            1475.779,
            601.135
          ],
          [
            1527.779,
            601.135
          ],
          [
            1527.779,
            712.135
          ],
          [
            1475.779,
            712.135
          ]
        ]
      ]
    },
    {
      "id": "room-002",
      "label": "002 West Stair 2 \u00b7 floor 3 floor / ceiling",
      "quantity": 133.11738414154226,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Floor-level core footprint; carries no finished-floor or ceiling assignment. Reconcile stair landings / shaft openings with details.",
      "polygons": [
        [
          [
            325.779,
            788.135
          ],
          [
            439.779,
            788.135
          ],
          [
            439.779,
            840.135
          ],
          [
            325.779,
            840.135
          ]
        ]
      ]
    },
    {
      "id": "walls-002",
      "label": "002 West Stair 2 \u00b7 floor 3 gross wall faces",
      "quantity": 49.75094949150791,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Floor-level core footprint; carries no finished-floor or ceiling assignment. Reconcile stair landings / shaft openings with details.",
      "polygons": [
        [
          [
            325.779,
            788.135
          ],
          [
            439.779,
            788.135
          ],
          [
            439.779,
            840.135
          ],
          [
            325.779,
            840.135
          ]
        ]
      ]
    },
    {
      "id": "room-300",
      "label": "300 Elevator lobby floor / ceiling",
      "quantity": 211.19584983994685,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1341.779,
            608.135
          ],
          [
            1416.779,
            608.135
          ],
          [
            1416.779,
            698.135
          ],
          [
            1400.779,
            698.135
          ],
          [
            1400.779,
            743.135
          ],
          [
            1341.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "walls-300",
      "label": "300 Elevator lobby gross wall faces",
      "quantity": 62.9379481519076,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1341.779,
            608.135
          ],
          [
            1416.779,
            608.135
          ],
          [
            1416.779,
            698.135
          ],
          [
            1400.779,
            698.135
          ],
          [
            1400.779,
            743.135
          ],
          [
            1341.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "room-301",
      "label": "301 King studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            325.779,
            553.135
          ],
          [
            400.779,
            553.135
          ],
          [
            400.779,
            743.135
          ],
          [
            325.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "walls-301",
      "label": "301 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            325.779,
            553.135
          ],
          [
            400.779,
            553.135
          ],
          [
            400.779,
            743.135
          ],
          [
            325.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "room-302",
      "label": "302 King one-bedroom floor / ceiling",
      "quantity": 517.4242181830999,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            325.779,
            849.135
          ],
          [
            443.779,
            849.135
          ],
          [
            443.779,
            788.135
          ],
          [
            485.779,
            788.135
          ],
          [
            485.779,
            977.135
          ],
          [
            325.779,
            977.135
          ]
        ]
      ]
    },
    {
      "id": "walls-302",
      "label": "302 King one-bedroom gross wall faces",
      "quantity": 104.59687573817024,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            325.779,
            849.135
          ],
          [
            443.779,
            849.135
          ],
          [
            443.779,
            788.135
          ],
          [
            485.779,
            788.135
          ],
          [
            485.779,
            977.135
          ],
          [
            325.779,
            977.135
          ]
        ]
      ]
    },
    {
      "id": "room-303",
      "label": "303 King studio floor / ceiling",
      "quantity": 328.5268775288062,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            409.779,
            553.135
          ],
          [
            486.779,
            553.135
          ],
          [
            486.779,
            743.135
          ],
          [
            409.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "walls-303",
      "label": "303 King studio gross wall faces",
      "quantity": 80.02110550742537,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            409.779,
            553.135
          ],
          [
            486.779,
            553.135
          ],
          [
            486.779,
            743.135
          ],
          [
            409.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "room-304",
      "label": "304 King studio floor / ceiling",
      "quantity": 318.3095344477668,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            495.779,
            788.135
          ],
          [
            570.779,
            788.135
          ],
          [
            570.779,
            977.135
          ],
          [
            495.779,
            977.135
          ]
        ]
      ]
    },
    {
      "id": "walls-304",
      "label": "304 King studio gross wall faces",
      "quantity": 79.12199196239813,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            495.779,
            788.135
          ],
          [
            570.779,
            788.135
          ],
          [
            570.779,
            977.135
          ],
          [
            495.779,
            977.135
          ]
        ]
      ]
    },
    {
      "id": "room-305",
      "label": "305 Connecting king studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            495.779,
            553.135
          ],
          [
            570.779,
            553.135
          ],
          [
            570.779,
            743.135
          ],
          [
            495.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "walls-305",
      "label": "305 Connecting king studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            495.779,
            553.135
          ],
          [
            570.779,
            553.135
          ],
          [
            570.779,
            743.135
          ],
          [
            495.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "room-306",
      "label": "306 King studio floor / ceiling",
      "quantity": 322.55366157373703,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            579.779,
            788.135
          ],
          [
            655.779,
            788.135
          ],
          [
            655.779,
            977.135
          ],
          [
            579.779,
            977.135
          ]
        ]
      ]
    },
    {
      "id": "walls-306",
      "label": "306 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            579.779,
            788.135
          ],
          [
            655.779,
            788.135
          ],
          [
            655.779,
            977.135
          ],
          [
            579.779,
            977.135
          ]
        ]
      ]
    },
    {
      "id": "room-307",
      "label": "307 Accessible king one-bedroom floor / ceiling",
      "quantity": 556.9013371643468,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            580.779,
            588.135
          ],
          [
            740.779,
            588.135
          ],
          [
            740.779,
            743.135
          ],
          [
            580.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "walls-307",
      "label": "307 Accessible king one-bedroom gross wall faces",
      "quantity": 94.4069222278614,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            580.779,
            588.135
          ],
          [
            740.779,
            588.135
          ],
          [
            740.779,
            743.135
          ],
          [
            580.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "room-308",
      "label": "308 King studio floor / ceiling",
      "quantity": 322.55366157373703,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            664.779,
            788.135
          ],
          [
            740.779,
            788.135
          ],
          [
            740.779,
            977.135
          ],
          [
            664.779,
            977.135
          ]
        ]
      ]
    },
    {
      "id": "walls-308",
      "label": "308 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            664.779,
            788.135
          ],
          [
            740.779,
            788.135
          ],
          [
            740.779,
            977.135
          ],
          [
            664.779,
            977.135
          ]
        ]
      ]
    },
    {
      "id": "room-309",
      "label": "309 King studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            749.779,
            553.135
          ],
          [
            824.779,
            553.135
          ],
          [
            824.779,
            743.135
          ],
          [
            749.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "walls-309",
      "label": "309 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            749.779,
            553.135
          ],
          [
            824.779,
            553.135
          ],
          [
            824.779,
            743.135
          ],
          [
            749.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "room-310",
      "label": "310 King studio floor / ceiling",
      "quantity": 318.3095344477668,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            749.779,
            788.135
          ],
          [
            824.779,
            788.135
          ],
          [
            824.779,
            977.135
          ],
          [
            749.779,
            977.135
          ]
        ]
      ]
    },
    {
      "id": "walls-310",
      "label": "310 King studio gross wall faces",
      "quantity": 79.12199196239813,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            749.779,
            788.135
          ],
          [
            824.779,
            788.135
          ],
          [
            824.779,
            977.135
          ],
          [
            749.779,
            977.135
          ]
        ]
      ]
    },
    {
      "id": "room-311",
      "label": "311 King studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            833.779,
            553.135
          ],
          [
            908.779,
            553.135
          ],
          [
            908.779,
            743.135
          ],
          [
            833.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "walls-311",
      "label": "311 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            833.779,
            553.135
          ],
          [
            908.779,
            553.135
          ],
          [
            908.779,
            743.135
          ],
          [
            833.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "room-312",
      "label": "312 King studio floor / ceiling",
      "quantity": 318.3095344477668,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            833.779,
            788.135
          ],
          [
            908.779,
            788.135
          ],
          [
            908.779,
            977.135
          ],
          [
            833.779,
            977.135
          ]
        ]
      ]
    },
    {
      "id": "walls-312",
      "label": "312 King studio gross wall faces",
      "quantity": 79.12199196239813,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            833.779,
            788.135
          ],
          [
            908.779,
            788.135
          ],
          [
            908.779,
            977.135
          ],
          [
            833.779,
            977.135
          ]
        ]
      ]
    },
    {
      "id": "room-313",
      "label": "313 King studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            918.779,
            553.135
          ],
          [
            993.779,
            553.135
          ],
          [
            993.779,
            743.135
          ],
          [
            918.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "walls-313",
      "label": "313 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            918.779,
            553.135
          ],
          [
            993.779,
            553.135
          ],
          [
            993.779,
            743.135
          ],
          [
            918.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "room-314",
      "label": "314 King studio floor / ceiling",
      "quantity": 318.3095344477668,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            918.779,
            788.135
          ],
          [
            993.779,
            788.135
          ],
          [
            993.779,
            977.135
          ],
          [
            918.779,
            977.135
          ]
        ]
      ]
    },
    {
      "id": "walls-314",
      "label": "314 King studio gross wall faces",
      "quantity": 79.12199196239813,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            918.779,
            788.135
          ],
          [
            993.779,
            788.135
          ],
          [
            993.779,
            977.135
          ],
          [
            918.779,
            977.135
          ]
        ]
      ]
    },
    {
      "id": "room-315",
      "label": "315 King studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1002.779,
            553.135
          ],
          [
            1077.779,
            553.135
          ],
          [
            1077.779,
            743.135
          ],
          [
            1002.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "walls-315",
      "label": "315 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1002.779,
            553.135
          ],
          [
            1077.779,
            553.135
          ],
          [
            1077.779,
            743.135
          ],
          [
            1002.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "room-316",
      "label": "316 Queen / queen floor / ceiling",
      "quantity": 380.53427659625083,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1003.779,
            788.135
          ],
          [
            1077.779,
            788.135
          ],
          [
            1077.779,
            1017.135
          ],
          [
            1003.779,
            1017.135
          ]
        ]
      ]
    },
    {
      "id": "walls-316",
      "label": "316 Queen / queen gross wall faces",
      "quantity": 90.8104680477524,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1003.779,
            788.135
          ],
          [
            1077.779,
            788.135
          ],
          [
            1077.779,
            1017.135
          ],
          [
            1003.779,
            1017.135
          ]
        ]
      ]
    },
    {
      "id": "room-317",
      "label": "317 King studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1087.779,
            553.135
          ],
          [
            1162.779,
            553.135
          ],
          [
            1162.779,
            743.135
          ],
          [
            1087.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "walls-317",
      "label": "317 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1087.779,
            553.135
          ],
          [
            1162.779,
            553.135
          ],
          [
            1162.779,
            743.135
          ],
          [
            1087.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "room-318",
      "label": "318 Queen / queen floor / ceiling",
      "quantity": 385.6766316853894,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1087.779,
            788.135
          ],
          [
            1162.779,
            788.135
          ],
          [
            1162.779,
            1017.135
          ],
          [
            1087.779,
            1017.135
          ]
        ]
      ]
    },
    {
      "id": "walls-318",
      "label": "318 Queen / queen gross wall faces",
      "quantity": 91.11017256276148,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1087.779,
            788.135
          ],
          [
            1162.779,
            788.135
          ],
          [
            1162.779,
            1017.135
          ],
          [
            1087.779,
            1017.135
          ]
        ]
      ]
    },
    {
      "id": "room-319",
      "label": "319 King studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1171.779,
            553.135
          ],
          [
            1246.779,
            553.135
          ],
          [
            1246.779,
            743.135
          ],
          [
            1171.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "walls-319",
      "label": "319 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1171.779,
            553.135
          ],
          [
            1246.779,
            553.135
          ],
          [
            1246.779,
            743.135
          ],
          [
            1171.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "room-320",
      "label": "320 Queen / queen floor / ceiling",
      "quantity": 385.6766316853894,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1171.779,
            788.135
          ],
          [
            1246.779,
            788.135
          ],
          [
            1246.779,
            1017.135
          ],
          [
            1171.779,
            1017.135
          ]
        ]
      ]
    },
    {
      "id": "walls-320",
      "label": "320 Queen / queen gross wall faces",
      "quantity": 91.11017256276148,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1171.779,
            788.135
          ],
          [
            1246.779,
            788.135
          ],
          [
            1246.779,
            1017.135
          ],
          [
            1171.779,
            1017.135
          ]
        ]
      ]
    },
    {
      "id": "room-321",
      "label": "321 King studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1256.779,
            553.135
          ],
          [
            1331.779,
            553.135
          ],
          [
            1331.779,
            743.135
          ],
          [
            1256.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "walls-321",
      "label": "321 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1256.779,
            553.135
          ],
          [
            1331.779,
            553.135
          ],
          [
            1331.779,
            743.135
          ],
          [
            1256.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "room-322",
      "label": "322 Queen / queen floor / ceiling",
      "quantity": 385.6766316853894,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1256.779,
            788.135
          ],
          [
            1331.779,
            788.135
          ],
          [
            1331.779,
            1017.135
          ],
          [
            1256.779,
            1017.135
          ]
        ]
      ]
    },
    {
      "id": "walls-322",
      "label": "322 Queen / queen gross wall faces",
      "quantity": 91.11017256276148,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1256.779,
            788.135
          ],
          [
            1331.779,
            788.135
          ],
          [
            1331.779,
            1017.135
          ],
          [
            1256.779,
            1017.135
          ]
        ]
      ]
    },
    {
      "id": "room-323",
      "label": "323 Storage floor / ceiling",
      "quantity": 56.857830068553476,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1341.779,
            553.135
          ],
          [
            1358.779,
            553.135
          ],
          [
            1358.779,
            574.135
          ],
          [
            1416.779,
            574.135
          ],
          [
            1416.779,
            603.135
          ],
          [
            1341.779,
            603.135
          ]
        ]
      ]
    },
    {
      "id": "walls-323",
      "label": "323 Storage gross wall faces",
      "quantity": 37.46306437613548,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1341.779,
            553.135
          ],
          [
            1358.779,
            553.135
          ],
          [
            1358.779,
            574.135
          ],
          [
            1416.779,
            574.135
          ],
          [
            1416.779,
            603.135
          ],
          [
            1341.779,
            603.135
          ]
        ]
      ]
    },
    {
      "id": "room-324",
      "label": "324 Connecting queen / queen floor / ceiling",
      "quantity": 380.53427659625083,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1341.779,
            788.135
          ],
          [
            1415.779,
            788.135
          ],
          [
            1415.779,
            1017.135
          ],
          [
            1341.779,
            1017.135
          ]
        ]
      ]
    },
    {
      "id": "walls-324",
      "label": "324 Connecting queen / queen gross wall faces",
      "quantity": 90.8104680477524,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1341.779,
            788.135
          ],
          [
            1415.779,
            788.135
          ],
          [
            1415.779,
            1017.135
          ],
          [
            1341.779,
            1017.135
          ]
        ]
      ]
    },
    {
      "id": "room-326",
      "label": "326 Accessible king studio floor / ceiling",
      "quantity": 524.5202190921295,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1425.779,
            788.135
          ],
          [
            1527.779,
            788.135
          ],
          [
            1527.779,
            1017.135
          ],
          [
            1425.779,
            1017.135
          ]
        ]
      ]
    },
    {
      "id": "walls-326",
      "label": "326 Accessible king studio gross wall faces",
      "quantity": 99.20219446800674,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1425.779,
            788.135
          ],
          [
            1527.779,
            788.135
          ],
          [
            1527.779,
            1017.135
          ],
          [
            1425.779,
            1017.135
          ]
        ]
      ]
    },
    {
      "id": "room-333",
      "label": "333 Corridor floor / ceiling",
      "quantity": 804.8571663969564,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            325.779,
            752.135
          ],
          [
            1406.779,
            752.135
          ],
          [
            1406.779,
            724.135
          ],
          [
            1527.779,
            724.135
          ],
          [
            1527.779,
            779.135
          ],
          [
            325.779,
            779.135
          ]
        ]
      ]
    },
    {
      "id": "walls-333",
      "label": "333 Corridor gross wall faces",
      "quantity": 376.72857536641834,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            325.779,
            752.135
          ],
          [
            1406.779,
            752.135
          ],
          [
            1406.779,
            724.135
          ],
          [
            1527.779,
            724.135
          ],
          [
            1527.779,
            779.135
          ],
          [
            325.779,
            779.135
          ]
        ]
      ]
    },
    {
      "id": "room-EL",
      "label": "EL Elevator core \u00b7 floor 3 floor / ceiling",
      "quantity": 99.43383552273096,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Floor-level core footprint; carries no finished-floor or ceiling assignment. Reconcile stair landings / shaft openings with details.",
      "polygons": [
        [
          [
            1424.779,
            601.135
          ],
          [
            1465.779,
            601.135
          ],
          [
            1465.779,
            709.135
          ],
          [
            1424.779,
            709.135
          ]
        ]
      ]
    },
    {
      "id": "walls-EL",
      "label": "EL Elevator core \u00b7 floor 3 gross wall faces",
      "quantity": 44.65597273635348,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Floor-level core footprint; carries no finished-floor or ceiling assignment. Reconcile stair landings / shaft openings with details.",
      "polygons": [
        [
          [
            1424.779,
            601.135
          ],
          [
            1465.779,
            601.135
          ],
          [
            1465.779,
            709.135
          ],
          [
            1424.779,
            709.135
          ]
        ]
      ]
    },
    {
      "id": "bath-301",
      "label": "301 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            325.779,
            693.135
          ],
          [
            366.779,
            693.135
          ],
          [
            366.779,
            743.135
          ],
          [
            325.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-301",
      "label": "301 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            325.779,
            693.135
          ],
          [
            366.779,
            693.135
          ],
          [
            366.779,
            743.135
          ],
          [
            325.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "main-301",
      "label": "301 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            325.779,
            553.135
          ],
          [
            400.779,
            553.135
          ],
          [
            400.779,
            743.135
          ],
          [
            325.779,
            743.135
          ]
        ],
        [
          [
            325.779,
            693.135
          ],
          [
            366.779,
            693.135
          ],
          [
            366.779,
            743.135
          ],
          [
            325.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "bath-303",
      "label": "303 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            445.779,
            693.135
          ],
          [
            486.779,
            693.135
          ],
          [
            486.779,
            743.135
          ],
          [
            445.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-303",
      "label": "303 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            445.779,
            693.135
          ],
          [
            486.779,
            693.135
          ],
          [
            486.779,
            743.135
          ],
          [
            445.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "main-303",
      "label": "303 room outside bathroom",
      "quantity": 282.49269441643077,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            409.779,
            553.135
          ],
          [
            486.779,
            553.135
          ],
          [
            486.779,
            743.135
          ],
          [
            409.779,
            743.135
          ]
        ],
        [
          [
            445.779,
            693.135
          ],
          [
            486.779,
            693.135
          ],
          [
            486.779,
            743.135
          ],
          [
            445.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "bath-305",
      "label": "305 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            495.779,
            693.135
          ],
          [
            536.779,
            693.135
          ],
          [
            536.779,
            743.135
          ],
          [
            495.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-305",
      "label": "305 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            495.779,
            693.135
          ],
          [
            536.779,
            693.135
          ],
          [
            536.779,
            743.135
          ],
          [
            495.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "main-305",
      "label": "305 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            495.779,
            553.135
          ],
          [
            570.779,
            553.135
          ],
          [
            570.779,
            743.135
          ],
          [
            495.779,
            743.135
          ]
        ],
        [
          [
            495.779,
            693.135
          ],
          [
            536.779,
            693.135
          ],
          [
            536.779,
            743.135
          ],
          [
            495.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "bath-309",
      "label": "309 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            783.779,
            693.135
          ],
          [
            824.779,
            693.135
          ],
          [
            824.779,
            743.135
          ],
          [
            783.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-309",
      "label": "309 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            783.779,
            693.135
          ],
          [
            824.779,
            693.135
          ],
          [
            824.779,
            743.135
          ],
          [
            783.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "main-309",
      "label": "309 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            749.779,
            553.135
          ],
          [
            824.779,
            553.135
          ],
          [
            824.779,
            743.135
          ],
          [
            749.779,
            743.135
          ]
        ],
        [
          [
            783.779,
            693.135
          ],
          [
            824.779,
            693.135
          ],
          [
            824.779,
            743.135
          ],
          [
            783.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "bath-311",
      "label": "311 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            833.779,
            693.135
          ],
          [
            874.779,
            693.135
          ],
          [
            874.779,
            743.135
          ],
          [
            833.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-311",
      "label": "311 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            833.779,
            693.135
          ],
          [
            874.779,
            693.135
          ],
          [
            874.779,
            743.135
          ],
          [
            833.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "main-311",
      "label": "311 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            833.779,
            553.135
          ],
          [
            908.779,
            553.135
          ],
          [
            908.779,
            743.135
          ],
          [
            833.779,
            743.135
          ]
        ],
        [
          [
            833.779,
            693.135
          ],
          [
            874.779,
            693.135
          ],
          [
            874.779,
            743.135
          ],
          [
            833.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "bath-313",
      "label": "313 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            952.779,
            693.135
          ],
          [
            993.779,
            693.135
          ],
          [
            993.779,
            743.135
          ],
          [
            952.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-313",
      "label": "313 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            952.779,
            693.135
          ],
          [
            993.779,
            693.135
          ],
          [
            993.779,
            743.135
          ],
          [
            952.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "main-313",
      "label": "313 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            918.779,
            553.135
          ],
          [
            993.779,
            553.135
          ],
          [
            993.779,
            743.135
          ],
          [
            918.779,
            743.135
          ]
        ],
        [
          [
            952.779,
            693.135
          ],
          [
            993.779,
            693.135
          ],
          [
            993.779,
            743.135
          ],
          [
            952.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "bath-315",
      "label": "315 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1002.779,
            693.135
          ],
          [
            1043.779,
            693.135
          ],
          [
            1043.779,
            743.135
          ],
          [
            1002.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-315",
      "label": "315 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1002.779,
            693.135
          ],
          [
            1043.779,
            693.135
          ],
          [
            1043.779,
            743.135
          ],
          [
            1002.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "main-315",
      "label": "315 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1002.779,
            553.135
          ],
          [
            1077.779,
            553.135
          ],
          [
            1077.779,
            743.135
          ],
          [
            1002.779,
            743.135
          ]
        ],
        [
          [
            1002.779,
            693.135
          ],
          [
            1043.779,
            693.135
          ],
          [
            1043.779,
            743.135
          ],
          [
            1002.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "bath-317",
      "label": "317 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1121.779,
            693.135
          ],
          [
            1162.779,
            693.135
          ],
          [
            1162.779,
            743.135
          ],
          [
            1121.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-317",
      "label": "317 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1121.779,
            693.135
          ],
          [
            1162.779,
            693.135
          ],
          [
            1162.779,
            743.135
          ],
          [
            1121.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "main-317",
      "label": "317 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1087.779,
            553.135
          ],
          [
            1162.779,
            553.135
          ],
          [
            1162.779,
            743.135
          ],
          [
            1087.779,
            743.135
          ]
        ],
        [
          [
            1121.779,
            693.135
          ],
          [
            1162.779,
            693.135
          ],
          [
            1162.779,
            743.135
          ],
          [
            1121.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "bath-319",
      "label": "319 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1171.779,
            693.135
          ],
          [
            1212.779,
            693.135
          ],
          [
            1212.779,
            743.135
          ],
          [
            1171.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-319",
      "label": "319 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1171.779,
            693.135
          ],
          [
            1212.779,
            693.135
          ],
          [
            1212.779,
            743.135
          ],
          [
            1171.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "main-319",
      "label": "319 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1171.779,
            553.135
          ],
          [
            1246.779,
            553.135
          ],
          [
            1246.779,
            743.135
          ],
          [
            1171.779,
            743.135
          ]
        ],
        [
          [
            1171.779,
            693.135
          ],
          [
            1212.779,
            693.135
          ],
          [
            1212.779,
            743.135
          ],
          [
            1171.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "bath-321",
      "label": "321 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1290.779,
            693.135
          ],
          [
            1331.779,
            693.135
          ],
          [
            1331.779,
            743.135
          ],
          [
            1290.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-321",
      "label": "321 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1290.779,
            693.135
          ],
          [
            1331.779,
            693.135
          ],
          [
            1331.779,
            743.135
          ],
          [
            1290.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "main-321",
      "label": "321 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1256.779,
            553.135
          ],
          [
            1331.779,
            553.135
          ],
          [
            1331.779,
            743.135
          ],
          [
            1256.779,
            743.135
          ]
        ],
        [
          [
            1290.779,
            693.135
          ],
          [
            1331.779,
            693.135
          ],
          [
            1331.779,
            743.135
          ],
          [
            1290.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "bath-304",
      "label": "304 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            495.779,
            788.135
          ],
          [
            536.779,
            788.135
          ],
          [
            536.779,
            842.135
          ],
          [
            495.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-304",
      "label": "304 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            495.779,
            788.135
          ],
          [
            536.779,
            788.135
          ],
          [
            536.779,
            842.135
          ],
          [
            495.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "main-304",
      "label": "304 room outside bathroom",
      "quantity": 268.5926166864013,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            495.779,
            788.135
          ],
          [
            570.779,
            788.135
          ],
          [
            570.779,
            977.135
          ],
          [
            495.779,
            977.135
          ]
        ],
        [
          [
            495.779,
            788.135
          ],
          [
            536.779,
            788.135
          ],
          [
            536.779,
            842.135
          ],
          [
            495.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "bath-306",
      "label": "306 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            614.779,
            788.135
          ],
          [
            655.779,
            788.135
          ],
          [
            655.779,
            842.135
          ],
          [
            614.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-306",
      "label": "306 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            614.779,
            788.135
          ],
          [
            655.779,
            788.135
          ],
          [
            655.779,
            842.135
          ],
          [
            614.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "main-306",
      "label": "306 room outside bathroom",
      "quantity": 272.83674381237154,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            579.779,
            788.135
          ],
          [
            655.779,
            788.135
          ],
          [
            655.779,
            977.135
          ],
          [
            579.779,
            977.135
          ]
        ],
        [
          [
            614.779,
            788.135
          ],
          [
            655.779,
            788.135
          ],
          [
            655.779,
            842.135
          ],
          [
            614.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "bath-308",
      "label": "308 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            664.779,
            788.135
          ],
          [
            705.779,
            788.135
          ],
          [
            705.779,
            842.135
          ],
          [
            664.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-308",
      "label": "308 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            664.779,
            788.135
          ],
          [
            705.779,
            788.135
          ],
          [
            705.779,
            842.135
          ],
          [
            664.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "main-308",
      "label": "308 room outside bathroom",
      "quantity": 272.83674381237154,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            664.779,
            788.135
          ],
          [
            740.779,
            788.135
          ],
          [
            740.779,
            977.135
          ],
          [
            664.779,
            977.135
          ]
        ],
        [
          [
            664.779,
            788.135
          ],
          [
            705.779,
            788.135
          ],
          [
            705.779,
            842.135
          ],
          [
            664.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "bath-310",
      "label": "310 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            783.779,
            788.135
          ],
          [
            824.779,
            788.135
          ],
          [
            824.779,
            842.135
          ],
          [
            783.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-310",
      "label": "310 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            783.779,
            788.135
          ],
          [
            824.779,
            788.135
          ],
          [
            824.779,
            842.135
          ],
          [
            783.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "main-310",
      "label": "310 room outside bathroom",
      "quantity": 268.5926166864013,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            749.779,
            788.135
          ],
          [
            824.779,
            788.135
          ],
          [
            824.779,
            977.135
          ],
          [
            749.779,
            977.135
          ]
        ],
        [
          [
            783.779,
            788.135
          ],
          [
            824.779,
            788.135
          ],
          [
            824.779,
            842.135
          ],
          [
            783.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "bath-312",
      "label": "312 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            833.779,
            788.135
          ],
          [
            874.779,
            788.135
          ],
          [
            874.779,
            842.135
          ],
          [
            833.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-312",
      "label": "312 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            833.779,
            788.135
          ],
          [
            874.779,
            788.135
          ],
          [
            874.779,
            842.135
          ],
          [
            833.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "main-312",
      "label": "312 room outside bathroom",
      "quantity": 268.5926166864013,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            833.779,
            788.135
          ],
          [
            908.779,
            788.135
          ],
          [
            908.779,
            977.135
          ],
          [
            833.779,
            977.135
          ]
        ],
        [
          [
            833.779,
            788.135
          ],
          [
            874.779,
            788.135
          ],
          [
            874.779,
            842.135
          ],
          [
            833.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "bath-314",
      "label": "314 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            952.779,
            788.135
          ],
          [
            993.779,
            788.135
          ],
          [
            993.779,
            842.135
          ],
          [
            952.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-314",
      "label": "314 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            952.779,
            788.135
          ],
          [
            993.779,
            788.135
          ],
          [
            993.779,
            842.135
          ],
          [
            952.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "main-314",
      "label": "314 room outside bathroom",
      "quantity": 268.5926166864013,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            918.779,
            788.135
          ],
          [
            993.779,
            788.135
          ],
          [
            993.779,
            977.135
          ],
          [
            918.779,
            977.135
          ]
        ],
        [
          [
            952.779,
            788.135
          ],
          [
            993.779,
            788.135
          ],
          [
            993.779,
            842.135
          ],
          [
            952.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "bath-316",
      "label": "316 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1036.779,
            788.135
          ],
          [
            1077.779,
            788.135
          ],
          [
            1077.779,
            842.135
          ],
          [
            1036.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-316",
      "label": "316 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1036.779,
            788.135
          ],
          [
            1077.779,
            788.135
          ],
          [
            1077.779,
            842.135
          ],
          [
            1036.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "main-316",
      "label": "316 room outside bathroom",
      "quantity": 330.81735883488534,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1003.779,
            788.135
          ],
          [
            1077.779,
            788.135
          ],
          [
            1077.779,
            1017.135
          ],
          [
            1003.779,
            1017.135
          ]
        ],
        [
          [
            1036.779,
            788.135
          ],
          [
            1077.779,
            788.135
          ],
          [
            1077.779,
            842.135
          ],
          [
            1036.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "bath-318",
      "label": "318 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1087.779,
            788.135
          ],
          [
            1128.779,
            788.135
          ],
          [
            1128.779,
            842.135
          ],
          [
            1087.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-318",
      "label": "318 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1087.779,
            788.135
          ],
          [
            1128.779,
            788.135
          ],
          [
            1128.779,
            842.135
          ],
          [
            1087.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "main-318",
      "label": "318 room outside bathroom",
      "quantity": 335.9597139240239,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1087.779,
            788.135
          ],
          [
            1162.779,
            788.135
          ],
          [
            1162.779,
            1017.135
          ],
          [
            1087.779,
            1017.135
          ]
        ],
        [
          [
            1087.779,
            788.135
          ],
          [
            1128.779,
            788.135
          ],
          [
            1128.779,
            842.135
          ],
          [
            1087.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "bath-320",
      "label": "320 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1205.779,
            788.135
          ],
          [
            1246.779,
            788.135
          ],
          [
            1246.779,
            842.135
          ],
          [
            1205.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-320",
      "label": "320 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1205.779,
            788.135
          ],
          [
            1246.779,
            788.135
          ],
          [
            1246.779,
            842.135
          ],
          [
            1205.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "main-320",
      "label": "320 room outside bathroom",
      "quantity": 335.9597139240239,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1171.779,
            788.135
          ],
          [
            1246.779,
            788.135
          ],
          [
            1246.779,
            1017.135
          ],
          [
            1171.779,
            1017.135
          ]
        ],
        [
          [
            1205.779,
            788.135
          ],
          [
            1246.779,
            788.135
          ],
          [
            1246.779,
            842.135
          ],
          [
            1205.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "bath-322",
      "label": "322 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1256.779,
            788.135
          ],
          [
            1297.779,
            788.135
          ],
          [
            1297.779,
            842.135
          ],
          [
            1256.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-322",
      "label": "322 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1256.779,
            788.135
          ],
          [
            1297.779,
            788.135
          ],
          [
            1297.779,
            842.135
          ],
          [
            1256.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "main-322",
      "label": "322 room outside bathroom",
      "quantity": 335.9597139240239,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1256.779,
            788.135
          ],
          [
            1331.779,
            788.135
          ],
          [
            1331.779,
            1017.135
          ],
          [
            1256.779,
            1017.135
          ]
        ],
        [
          [
            1256.779,
            788.135
          ],
          [
            1297.779,
            788.135
          ],
          [
            1297.779,
            842.135
          ],
          [
            1256.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "bath-324",
      "label": "324 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1374.779,
            788.135
          ],
          [
            1415.779,
            788.135
          ],
          [
            1415.779,
            842.135
          ],
          [
            1374.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-324",
      "label": "324 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1374.779,
            788.135
          ],
          [
            1415.779,
            788.135
          ],
          [
            1415.779,
            842.135
          ],
          [
            1374.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "main-324",
      "label": "324 room outside bathroom",
      "quantity": 330.81735883488534,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1341.779,
            788.135
          ],
          [
            1415.779,
            788.135
          ],
          [
            1415.779,
            1017.135
          ],
          [
            1341.779,
            1017.135
          ]
        ],
        [
          [
            1374.779,
            788.135
          ],
          [
            1415.779,
            788.135
          ],
          [
            1415.779,
            842.135
          ],
          [
            1374.779,
            842.135
          ]
        ]
      ]
    },
    {
      "id": "bath-307",
      "label": "307 bathroom zone",
      "quantity": 87.0382896310084,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            664.779,
            692.135
          ],
          [
            740.779,
            692.135
          ],
          [
            740.779,
            743.135
          ],
          [
            664.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-307",
      "label": "307 bathroom wall faces",
      "quantity": 38.06247340615364,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            664.779,
            692.135
          ],
          [
            740.779,
            692.135
          ],
          [
            740.779,
            743.135
          ],
          [
            664.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "main-307",
      "label": "307 room outside bathroom",
      "quantity": 469.86304753333843,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            580.779,
            588.135
          ],
          [
            740.779,
            588.135
          ],
          [
            740.779,
            743.135
          ],
          [
            580.779,
            743.135
          ]
        ],
        [
          [
            664.779,
            692.135
          ],
          [
            740.779,
            692.135
          ],
          [
            740.779,
            743.135
          ],
          [
            664.779,
            743.135
          ]
        ]
      ]
    },
    {
      "id": "bath-302",
      "label": "302 bathroom zone",
      "quantity": 68.13059100631565,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            325.779,
            849.135
          ],
          [
            399.779,
            849.135
          ],
          [
            399.779,
            890.135
          ],
          [
            325.779,
            890.135
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-302",
      "label": "302 bathroom wall faces",
      "quantity": 34.46601922604464,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            325.779,
            849.135
          ],
          [
            399.779,
            849.135
          ],
          [
            399.779,
            890.135
          ],
          [
            325.779,
            890.135
          ]
        ]
      ]
    },
    {
      "id": "main-302",
      "label": "302 room outside bathroom",
      "quantity": 449.2936271767843,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            325.779,
            849.135
          ],
          [
            443.779,
            849.135
          ],
          [
            443.779,
            788.135
          ],
          [
            485.779,
            788.135
          ],
          [
            485.779,
            977.135
          ],
          [
            325.779,
            977.135
          ]
        ],
        [
          [
            325.779,
            849.135
          ],
          [
            399.779,
            849.135
          ],
          [
            399.779,
            890.135
          ],
          [
            325.779,
            890.135
          ]
        ]
      ]
    },
    {
      "id": "bath-326",
      "label": "326 bathroom zone",
      "quantity": 67.83866691828595,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1470.779,
            788.135
          ],
          [
            1527.779,
            788.135
          ],
          [
            1527.779,
            841.135
          ],
          [
            1470.779,
            841.135
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-326",
      "label": "326 bathroom wall faces",
      "quantity": 32.967496650999216,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1470.779,
            788.135
          ],
          [
            1527.779,
            788.135
          ],
          [
            1527.779,
            841.135
          ],
          [
            1470.779,
            841.135
          ]
        ]
      ]
    },
    {
      "id": "main-326",
      "label": "326 room outside bathroom",
      "quantity": 456.68155217384356,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1425.779,
            788.135
          ],
          [
            1527.779,
            788.135
          ],
          [
            1527.779,
            1017.135
          ],
          [
            1425.779,
            1017.135
          ]
        ],
        [
          [
            1470.779,
            788.135
          ],
          [
            1527.779,
            788.135
          ],
          [
            1527.779,
            841.135
          ],
          [
            1470.779,
            841.135
          ]
        ]
      ]
    }
  ],
  "roomRegister": [
    {
      "id": "001",
      "name": "East Stair 1 \u00b7 floor 3",
      "kind": "stair",
      "polygon": [
        [
          1475.779,
          601.135
        ],
        [
          1527.779,
          601.135
        ],
        [
          1527.779,
          712.135
        ],
        [
          1475.779,
          712.135
        ]
      ],
      "floorFootprintSF": 129.6142950851859,
      "ceilingFootprintSF": 129.6142950851859,
      "grossWallFaceRunLF": 48.85183594648066,
      "scopeKey": "bradenton/floor3/room001",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "002",
      "name": "West Stair 2 \u00b7 floor 3",
      "kind": "stair",
      "polygon": [
        [
          325.779,
          788.135
        ],
        [
          439.779,
          788.135
        ],
        [
          439.779,
          840.135
        ],
        [
          325.779,
          840.135
        ]
      ],
      "floorFootprintSF": 133.11738414154226,
      "ceilingFootprintSF": 133.11738414154226,
      "grossWallFaceRunLF": 49.75094949150791,
      "scopeKey": "bradenton/floor3/room002",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "300",
      "name": "Elevator lobby",
      "kind": "enclosed",
      "polygon": [
        [
          1341.779,
          608.135
        ],
        [
          1416.779,
          608.135
        ],
        [
          1416.779,
          698.135
        ],
        [
          1400.779,
          698.135
        ],
        [
          1400.779,
          743.135
        ],
        [
          1341.779,
          743.135
        ]
      ],
      "floorFootprintSF": 211.19584983994685,
      "ceilingFootprintSF": 211.19584983994685,
      "grossWallFaceRunLF": 62.9379481519076,
      "scopeKey": "bradenton/floor3/room300",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "301",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          325.779,
          553.135
        ],
        [
          400.779,
          553.135
        ],
        [
          400.779,
          743.135
        ],
        [
          325.779,
          743.135
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor3/room301",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "302",
      "name": "King one-bedroom",
      "kind": "enclosed",
      "polygon": [
        [
          325.779,
          849.135
        ],
        [
          443.779,
          849.135
        ],
        [
          443.779,
          788.135
        ],
        [
          485.779,
          788.135
        ],
        [
          485.779,
          977.135
        ],
        [
          325.779,
          977.135
        ]
      ],
      "floorFootprintSF": 517.4242181830999,
      "ceilingFootprintSF": 517.4242181830999,
      "grossWallFaceRunLF": 104.59687573817024,
      "scopeKey": "bradenton/floor3/room302",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "303",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          409.779,
          553.135
        ],
        [
          486.779,
          553.135
        ],
        [
          486.779,
          743.135
        ],
        [
          409.779,
          743.135
        ]
      ],
      "floorFootprintSF": 328.5268775288062,
      "ceilingFootprintSF": 328.5268775288062,
      "grossWallFaceRunLF": 80.02110550742537,
      "scopeKey": "bradenton/floor3/room303",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "304",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          495.779,
          788.135
        ],
        [
          570.779,
          788.135
        ],
        [
          570.779,
          977.135
        ],
        [
          495.779,
          977.135
        ]
      ],
      "floorFootprintSF": 318.3095344477668,
      "ceilingFootprintSF": 318.3095344477668,
      "grossWallFaceRunLF": 79.12199196239813,
      "scopeKey": "bradenton/floor3/room304",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "305",
      "name": "Connecting king studio",
      "kind": "enclosed",
      "polygon": [
        [
          495.779,
          553.135
        ],
        [
          570.779,
          553.135
        ],
        [
          570.779,
          743.135
        ],
        [
          495.779,
          743.135
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor3/room305",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "306",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          579.779,
          788.135
        ],
        [
          655.779,
          788.135
        ],
        [
          655.779,
          977.135
        ],
        [
          579.779,
          977.135
        ]
      ],
      "floorFootprintSF": 322.55366157373703,
      "ceilingFootprintSF": 322.55366157373703,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor3/room306",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "307",
      "name": "Accessible king one-bedroom",
      "kind": "enclosed",
      "polygon": [
        [
          580.779,
          588.135
        ],
        [
          740.779,
          588.135
        ],
        [
          740.779,
          743.135
        ],
        [
          580.779,
          743.135
        ]
      ],
      "floorFootprintSF": 556.9013371643468,
      "ceilingFootprintSF": 556.9013371643468,
      "grossWallFaceRunLF": 94.4069222278614,
      "scopeKey": "bradenton/floor3/room307",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "308",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          664.779,
          788.135
        ],
        [
          740.779,
          788.135
        ],
        [
          740.779,
          977.135
        ],
        [
          664.779,
          977.135
        ]
      ],
      "floorFootprintSF": 322.55366157373703,
      "ceilingFootprintSF": 322.55366157373703,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor3/room308",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "309",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          749.779,
          553.135
        ],
        [
          824.779,
          553.135
        ],
        [
          824.779,
          743.135
        ],
        [
          749.779,
          743.135
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor3/room309",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "310",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          749.779,
          788.135
        ],
        [
          824.779,
          788.135
        ],
        [
          824.779,
          977.135
        ],
        [
          749.779,
          977.135
        ]
      ],
      "floorFootprintSF": 318.3095344477668,
      "ceilingFootprintSF": 318.3095344477668,
      "grossWallFaceRunLF": 79.12199196239813,
      "scopeKey": "bradenton/floor3/room310",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "311",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          833.779,
          553.135
        ],
        [
          908.779,
          553.135
        ],
        [
          908.779,
          743.135
        ],
        [
          833.779,
          743.135
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor3/room311",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "312",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          833.779,
          788.135
        ],
        [
          908.779,
          788.135
        ],
        [
          908.779,
          977.135
        ],
        [
          833.779,
          977.135
        ]
      ],
      "floorFootprintSF": 318.3095344477668,
      "ceilingFootprintSF": 318.3095344477668,
      "grossWallFaceRunLF": 79.12199196239813,
      "scopeKey": "bradenton/floor3/room312",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "313",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          918.779,
          553.135
        ],
        [
          993.779,
          553.135
        ],
        [
          993.779,
          743.135
        ],
        [
          918.779,
          743.135
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor3/room313",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "314",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          918.779,
          788.135
        ],
        [
          993.779,
          788.135
        ],
        [
          993.779,
          977.135
        ],
        [
          918.779,
          977.135
        ]
      ],
      "floorFootprintSF": 318.3095344477668,
      "ceilingFootprintSF": 318.3095344477668,
      "grossWallFaceRunLF": 79.12199196239813,
      "scopeKey": "bradenton/floor3/room314",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "315",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          1002.779,
          553.135
        ],
        [
          1077.779,
          553.135
        ],
        [
          1077.779,
          743.135
        ],
        [
          1002.779,
          743.135
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor3/room315",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "316",
      "name": "Queen / queen",
      "kind": "enclosed",
      "polygon": [
        [
          1003.779,
          788.135
        ],
        [
          1077.779,
          788.135
        ],
        [
          1077.779,
          1017.135
        ],
        [
          1003.779,
          1017.135
        ]
      ],
      "floorFootprintSF": 380.53427659625083,
      "ceilingFootprintSF": 380.53427659625083,
      "grossWallFaceRunLF": 90.8104680477524,
      "scopeKey": "bradenton/floor3/room316",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "317",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          1087.779,
          553.135
        ],
        [
          1162.779,
          553.135
        ],
        [
          1162.779,
          743.135
        ],
        [
          1087.779,
          743.135
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor3/room317",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "318",
      "name": "Queen / queen",
      "kind": "enclosed",
      "polygon": [
        [
          1087.779,
          788.135
        ],
        [
          1162.779,
          788.135
        ],
        [
          1162.779,
          1017.135
        ],
        [
          1087.779,
          1017.135
        ]
      ],
      "floorFootprintSF": 385.6766316853894,
      "ceilingFootprintSF": 385.6766316853894,
      "grossWallFaceRunLF": 91.11017256276148,
      "scopeKey": "bradenton/floor3/room318",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "319",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          1171.779,
          553.135
        ],
        [
          1246.779,
          553.135
        ],
        [
          1246.779,
          743.135
        ],
        [
          1171.779,
          743.135
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor3/room319",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "320",
      "name": "Queen / queen",
      "kind": "enclosed",
      "polygon": [
        [
          1171.779,
          788.135
        ],
        [
          1246.779,
          788.135
        ],
        [
          1246.779,
          1017.135
        ],
        [
          1171.779,
          1017.135
        ]
      ],
      "floorFootprintSF": 385.6766316853894,
      "ceilingFootprintSF": 385.6766316853894,
      "grossWallFaceRunLF": 91.11017256276148,
      "scopeKey": "bradenton/floor3/room320",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "321",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          1256.779,
          553.135
        ],
        [
          1331.779,
          553.135
        ],
        [
          1331.779,
          743.135
        ],
        [
          1256.779,
          743.135
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor3/room321",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "322",
      "name": "Queen / queen",
      "kind": "enclosed",
      "polygon": [
        [
          1256.779,
          788.135
        ],
        [
          1331.779,
          788.135
        ],
        [
          1331.779,
          1017.135
        ],
        [
          1256.779,
          1017.135
        ]
      ],
      "floorFootprintSF": 385.6766316853894,
      "ceilingFootprintSF": 385.6766316853894,
      "grossWallFaceRunLF": 91.11017256276148,
      "scopeKey": "bradenton/floor3/room322",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "323",
      "name": "Storage",
      "kind": "enclosed",
      "polygon": [
        [
          1341.779,
          553.135
        ],
        [
          1358.779,
          553.135
        ],
        [
          1358.779,
          574.135
        ],
        [
          1416.779,
          574.135
        ],
        [
          1416.779,
          603.135
        ],
        [
          1341.779,
          603.135
        ]
      ],
      "floorFootprintSF": 56.857830068553476,
      "ceilingFootprintSF": 56.857830068553476,
      "grossWallFaceRunLF": 37.46306437613548,
      "scopeKey": "bradenton/floor3/room323",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "324",
      "name": "Connecting queen / queen",
      "kind": "enclosed",
      "polygon": [
        [
          1341.779,
          788.135
        ],
        [
          1415.779,
          788.135
        ],
        [
          1415.779,
          1017.135
        ],
        [
          1341.779,
          1017.135
        ]
      ],
      "floorFootprintSF": 380.53427659625083,
      "ceilingFootprintSF": 380.53427659625083,
      "grossWallFaceRunLF": 90.8104680477524,
      "scopeKey": "bradenton/floor3/room324",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "326",
      "name": "Accessible king studio",
      "kind": "enclosed",
      "polygon": [
        [
          1425.779,
          788.135
        ],
        [
          1527.779,
          788.135
        ],
        [
          1527.779,
          1017.135
        ],
        [
          1425.779,
          1017.135
        ]
      ],
      "floorFootprintSF": 524.5202190921295,
      "ceilingFootprintSF": 524.5202190921295,
      "grossWallFaceRunLF": 99.20219446800674,
      "scopeKey": "bradenton/floor3/room326",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "333",
      "name": "Corridor",
      "kind": "enclosed",
      "polygon": [
        [
          325.779,
          752.135
        ],
        [
          1406.779,
          752.135
        ],
        [
          1406.779,
          724.135
        ],
        [
          1527.779,
          724.135
        ],
        [
          1527.779,
          779.135
        ],
        [
          325.779,
          779.135
        ]
      ],
      "floorFootprintSF": 804.8571663969564,
      "ceilingFootprintSF": 804.8571663969564,
      "grossWallFaceRunLF": 376.72857536641834,
      "scopeKey": "bradenton/floor3/room333",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "EL",
      "name": "Elevator core \u00b7 floor 3",
      "kind": "shaft",
      "polygon": [
        [
          1424.779,
          601.135
        ],
        [
          1465.779,
          601.135
        ],
        [
          1465.779,
          709.135
        ],
        [
          1424.779,
          709.135
        ]
      ],
      "floorFootprintSF": 99.43383552273096,
      "ceilingFootprintSF": 99.43383552273096,
      "grossWallFaceRunLF": 44.65597273635348,
      "scopeKey": "bradenton/floor3/roomEL",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    }
  ],
  "bathroomZones": [
    {
      "room": "301",
      "polygon": [
        [
          325.779,
          693.135
        ],
        [
          366.779,
          693.135
        ],
        [
          366.779,
          743.135
        ],
        [
          325.779,
          743.135
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "303",
      "polygon": [
        [
          445.779,
          693.135
        ],
        [
          486.779,
          693.135
        ],
        [
          486.779,
          743.135
        ],
        [
          445.779,
          743.135
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "305",
      "polygon": [
        [
          495.779,
          693.135
        ],
        [
          536.779,
          693.135
        ],
        [
          536.779,
          743.135
        ],
        [
          495.779,
          743.135
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "309",
      "polygon": [
        [
          783.779,
          693.135
        ],
        [
          824.779,
          693.135
        ],
        [
          824.779,
          743.135
        ],
        [
          783.779,
          743.135
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "311",
      "polygon": [
        [
          833.779,
          693.135
        ],
        [
          874.779,
          693.135
        ],
        [
          874.779,
          743.135
        ],
        [
          833.779,
          743.135
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "313",
      "polygon": [
        [
          952.779,
          693.135
        ],
        [
          993.779,
          693.135
        ],
        [
          993.779,
          743.135
        ],
        [
          952.779,
          743.135
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "315",
      "polygon": [
        [
          1002.779,
          693.135
        ],
        [
          1043.779,
          693.135
        ],
        [
          1043.779,
          743.135
        ],
        [
          1002.779,
          743.135
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "317",
      "polygon": [
        [
          1121.779,
          693.135
        ],
        [
          1162.779,
          693.135
        ],
        [
          1162.779,
          743.135
        ],
        [
          1121.779,
          743.135
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "319",
      "polygon": [
        [
          1171.779,
          693.135
        ],
        [
          1212.779,
          693.135
        ],
        [
          1212.779,
          743.135
        ],
        [
          1171.779,
          743.135
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "321",
      "polygon": [
        [
          1290.779,
          693.135
        ],
        [
          1331.779,
          693.135
        ],
        [
          1331.779,
          743.135
        ],
        [
          1290.779,
          743.135
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "304",
      "polygon": [
        [
          495.779,
          788.135
        ],
        [
          536.779,
          788.135
        ],
        [
          536.779,
          842.135
        ],
        [
          495.779,
          842.135
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "306",
      "polygon": [
        [
          614.779,
          788.135
        ],
        [
          655.779,
          788.135
        ],
        [
          655.779,
          842.135
        ],
        [
          614.779,
          842.135
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "308",
      "polygon": [
        [
          664.779,
          788.135
        ],
        [
          705.779,
          788.135
        ],
        [
          705.779,
          842.135
        ],
        [
          664.779,
          842.135
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "310",
      "polygon": [
        [
          783.779,
          788.135
        ],
        [
          824.779,
          788.135
        ],
        [
          824.779,
          842.135
        ],
        [
          783.779,
          842.135
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "312",
      "polygon": [
        [
          833.779,
          788.135
        ],
        [
          874.779,
          788.135
        ],
        [
          874.779,
          842.135
        ],
        [
          833.779,
          842.135
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "314",
      "polygon": [
        [
          952.779,
          788.135
        ],
        [
          993.779,
          788.135
        ],
        [
          993.779,
          842.135
        ],
        [
          952.779,
          842.135
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "316",
      "polygon": [
        [
          1036.779,
          788.135
        ],
        [
          1077.779,
          788.135
        ],
        [
          1077.779,
          842.135
        ],
        [
          1036.779,
          842.135
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "318",
      "polygon": [
        [
          1087.779,
          788.135
        ],
        [
          1128.779,
          788.135
        ],
        [
          1128.779,
          842.135
        ],
        [
          1087.779,
          842.135
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "320",
      "polygon": [
        [
          1205.779,
          788.135
        ],
        [
          1246.779,
          788.135
        ],
        [
          1246.779,
          842.135
        ],
        [
          1205.779,
          842.135
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "322",
      "polygon": [
        [
          1256.779,
          788.135
        ],
        [
          1297.779,
          788.135
        ],
        [
          1297.779,
          842.135
        ],
        [
          1256.779,
          842.135
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "324",
      "polygon": [
        [
          1374.779,
          788.135
        ],
        [
          1415.779,
          788.135
        ],
        [
          1415.779,
          842.135
        ],
        [
          1374.779,
          842.135
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "307",
      "polygon": [
        [
          664.779,
          692.135
        ],
        [
          740.779,
          692.135
        ],
        [
          740.779,
          743.135
        ],
        [
          664.779,
          743.135
        ]
      ],
      "areaSF": 87.0382896310084
    },
    {
      "room": "302",
      "polygon": [
        [
          325.779,
          849.135
        ],
        [
          399.779,
          849.135
        ],
        [
          399.779,
          890.135
        ],
        [
          325.779,
          890.135
        ]
      ],
      "areaSF": 68.13059100631565
    },
    {
      "room": "326",
      "polygon": [
        [
          1470.779,
          788.135
        ],
        [
          1527.779,
          788.135
        ],
        [
          1527.779,
          841.135
        ],
        [
          1470.779,
          841.135
        ]
      ],
      "areaSF": 67.83866691828595
    }
  ],
  "wallAssignmentStatus": "No explicit W1\u2013W6 plan tags found. Keep exact assemblies unassigned while preserving separate corridor, party and exterior runs.",
  "reuseRule": "Room IDs are floor-qualified. Stair and elevator outlines continue building systems; do not create additional systems at every floor.",
  "measurementConfidence": "Approximate source traces registered to repeated floor geometry. Exact wall-type assignment, finish deductions, heights and structural opening limits remain identified coordination items."
}