  "sheet": "A2.2",
  "coordinateSpace": {
    "width": 1920,
    "height": 1280
  },
  "calibration": {
    "printedPlanScale": "1/8 inch = 1 foot",
    "pixelsPerFoot": 6.673239473684211,
    "basis": "36 x 24 inch PDF. Common structural grid 3\u20134 equals 84.528 normalized pixels and 12 feet 8 inches on A1.4; grid 4\u20135 independently repeats 84.528 pixels. Printed scale conversion differs by 0.10 percent.",
    "checks": [
      {
        "grid": "3\u20134",
        "pixels": 84.528,
        "feet": 12.666666666666666
      },
      {
        "grid": "4\u20135",
        "pixels": 84.528,
        "feet": 12.666666666666666
      }
    ]
  },
  "rows": [
    {
      "id": "gross-floor",
      "label": "Gross second-floor outline",
      "quantity": 12173.212015139325,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced main outline including walls and cores; small facade jogs simplified. Separate core deductions below.",
      "polygons": [
        [
          [
            347,
            549
          ],
          [
            603,
            549
          ],
          [
            603,
            587
          ],
          [
            776,
            587
          ],
          [
            776,
            549
          ],
          [
            1391,
            549
          ],
          [
            1391,
            572
          ],
          [
            1451,
            572
          ],
          [
            1451,
            599
          ],
          [
            1564,
            599
          ],
          [
            1564,
            1028
          ],
          [
            1028,
            1028
          ],
          [
            1028,
            988
          ],
          [
            347,
            988
          ]
        ]
      ]
    },
    {
      "id": "floor-deck",
      "label": "Floor deck \u00b7 core deductions",
      "quantity": 11811.046500389866,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Gross floor outline less two complete stair zones and elevator core. Stair landings and structural penetration limits require stair/structural details.",
      "polygons": [
        [
          [
            347,
            549
          ],
          [
            603,
            549
          ],
          [
            603,
            587
          ],
          [
            776,
            587
          ],
          [
            776,
            549
          ],
          [
            1391,
            549
          ],
          [
            1391,
            572
          ],
          [
            1451,
            572
          ],
          [
            1451,
            599
          ],
          [
            1564,
            599
          ],
          [
            1564,
            1028
          ],
          [
            1028,
            1028
          ],
          [
            1028,
            988
          ],
          [
            347,
            988
          ]
        ],
        [
          [
            1504,
            604
          ],
          [
            1556,
            604
          ],
          [
            1556,
            715
          ],
          [
            1504,
            715
          ]
        ],
        [
          [
            354,
            791
          ],
          [
            468,
            791
          ],
          [
            468,
            843
          ],
          [
            354,
            843
          ]
        ],
        [
          [
            1453,
            604
          ],
          [
            1494,
            604
          ],
          [
            1494,
            712
          ],
          [
            1453,
            712
          ]
        ]
      ]
    },
    {
      "id": "gypcrete",
      "label": "1\u00bd\u2033 gypcrete \u00b7 floor basis",
      "quantity": 54.68077083513827,
      "unit": "CY",
      "color": "#ba9138",
      "basis": "A0.2 UL L514 1\u00bd-inch gypcrete applied to traced deck basis excluding full stair zones and elevator core. Structural deck limits, wet-area buildup and waste to be resolved.",
      "polygons": [
        [
          [
            347,
            549
          ],
          [
            603,
            549
          ],
          [
            603,
            587
          ],
          [
            776,
            587
          ],
          [
            776,
            549
          ],
          [
            1391,
            549
          ],
          [
            1391,
            572
          ],
          [
            1451,
            572
          ],
          [
            1451,
            599
          ],
          [
            1564,
            599
          ],
          [
            1564,
            1028
          ],
          [
            1028,
            1028
          ],
          [
            1028,
            988
          ],
          [
            347,
            988
          ]
        ],
        [
          [
            1504,
            604
          ],
          [
            1556,
            604
          ],
          [
            1556,
            715
          ],
          [
            1504,
            715
          ]
        ],
        [
          [
            354,
            791
          ],
          [
            468,
            791
          ],
          [
            468,
            843
          ],
          [
            354,
            843
          ]
        ],
        [
          [
            1453,
            604
          ],
          [
            1494,
            604
          ],
          [
            1494,
            712
          ],
          [
            1453,
            712
          ]
        ]
      ]
    },
    {
      "id": "exterior",
      "label": "Exterior wall run \u00b7 gross",
      "quantity": 519.6876290257513,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Traced outer perimeter before glazing/opening deductions; wall type, heights and facade jogs to sections.",
      "polygons": [
        [
          [
            347,
            549
          ],
          [
            603,
            549
          ],
          [
            603,
            587
          ],
          [
            776,
            587
          ],
          [
            776,
            549
          ],
          [
            1391,
            549
          ],
          [
            1391,
            572
          ],
          [
            1451,
            572
          ],
          [
            1451,
            599
          ],
          [
            1564,
            599
          ],
          [
            1564,
            1028
          ],
          [
            1028,
            1028
          ],
          [
            1028,
            988
          ],
          [
            347,
            988
          ]
        ]
      ]
    },
    {
      "id": "corridor",
      "label": "Guest corridor wall runs",
      "quantity": 333.331361593103,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Two gross wall runs before door openings; north lobby opening omitted. Link exact W1-family assembly.",
      "lines": [
        [
          [
            350.7,
            750.1
          ],
          [
            1365,
            750.1
          ]
        ],
        [
          [
            350.7,
            786.8
          ],
          [
            1560.8,
            786.8
          ]
        ]
      ]
    },
    {
      "id": "party",
      "label": "Shared guestroom wall runs",
      "quantity": 671.443010200601,
      "unit": "LF",
      "color": "#cf4f62",
      "basis": "22 gross dividing-wall runs, each physical divider counted once. Connecting openings not deducted. Exact W3/W4 or other assignment awaits wall tags/sections.",
      "lines": [
        [
          [
            433.7,
            552.4
          ],
          [
            433.7,
            750.1
          ]
        ],
        [
          [
            519.7,
            552.4
          ],
          [
            519.7,
            750.1
          ]
        ],
        [
          [
            604.3,
            587
          ],
          [
            604.3,
            750.1
          ]
        ],
        [
          [
            773.3,
            587
          ],
          [
            773.3,
            750.1
          ]
        ],
        [
          [
            857.9,
            552.4
          ],
          [
            857.9,
            750.1
          ]
        ],
        [
          [
            942.4,
            552.4
          ],
          [
            942.4,
            750.1
          ]
        ],
        [
          [
            1026.9,
            552.4
          ],
          [
            1026.9,
            750.1
          ]
        ],
        [
          [
            1111.5,
            552.4
          ],
          [
            1111.5,
            750.1
          ]
        ],
        [
          [
            1196,
            552.4
          ],
          [
            1196,
            750.1
          ]
        ],
        [
          [
            1280.5,
            552.4
          ],
          [
            1280.5,
            750.1
          ]
        ],
        [
          [
            519.7,
            786.8
          ],
          [
            519.7,
            984.5
          ]
        ],
        [
          [
            604.3,
            786.8
          ],
          [
            604.3,
            984.5
          ]
        ],
        [
          [
            688.8,
            786.8
          ],
          [
            688.8,
            984.5
          ]
        ],
        [
          [
            773.3,
            786.8
          ],
          [
            773.3,
            984.5
          ]
        ],
        [
          [
            857.9,
            786.8
          ],
          [
            857.9,
            984.5
          ]
        ],
        [
          [
            942.4,
            786.8
          ],
          [
            942.4,
            984.5
          ]
        ],
        [
          [
            1026.9,
            786.8
          ],
          [
            1026.9,
            984.5
          ]
        ],
        [
          [
            1111.5,
            786.8
          ],
          [
            1111.5,
            1024.6
          ]
        ],
        [
          [
            1196,
            786.8
          ],
          [
            1196,
            1024.6
          ]
        ],
        [
          [
            1280.5,
            786.8
          ],
          [
            1280.5,
            1024.6
          ]
        ],
        [
          [
            1365,
            786.8
          ],
          [
            1365,
            1024.6
          ]
        ],
        [
          [
            1449.6,
            786.8
          ],
          [
            1449.6,
            1024.6
          ]
        ]
      ]
    },
    {
      "id": "room-001",
      "label": "001 East Stair 1 \u00b7 floor 2 floor / ceiling",
      "quantity": 129.6142950851859,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Floor-level core footprint; carries no finished-floor or ceiling assignment. Reconcile stair landings / shaft openings with details.",
      "polygons": [
        [
          [
            1504,
            604
          ],
          [
            1556,
            604
          ],
          [
            1556,
            715
          ],
          [
            1504,
            715
          ]
        ]
      ]
    },
    {
      "id": "walls-001",
      "label": "001 East Stair 1 \u00b7 floor 2 gross wall faces",
      "quantity": 48.85183594648066,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Floor-level core footprint; carries no finished-floor or ceiling assignment. Reconcile stair landings / shaft openings with details.",
      "polygons": [
        [
          [
            1504,
            604
          ],
          [
            1556,
            604
          ],
          [
            1556,
            715
          ],
          [
            1504,
            715
          ]
        ]
      ]
    },
    {
      "id": "room-002",
      "label": "002 West Stair 2 \u00b7 floor 2 floor / ceiling",
      "quantity": 133.11738414154226,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Floor-level core footprint; carries no finished-floor or ceiling assignment. Reconcile stair landings / shaft openings with details.",
      "polygons": [
        [
          [
            354,
            791
          ],
          [
            468,
            791
          ],
          [
            468,
            843
          ],
          [
            354,
            843
          ]
        ]
      ]
    },
    {
      "id": "walls-002",
      "label": "002 West Stair 2 \u00b7 floor 2 gross wall faces",
      "quantity": 49.75094949150791,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Floor-level core footprint; carries no finished-floor or ceiling assignment. Reconcile stair landings / shaft openings with details.",
      "polygons": [
        [
          [
            354,
            791
          ],
          [
            468,
            791
          ],
          [
            468,
            843
          ],
          [
            354,
            843
          ]
        ]
      ]
    },
    {
      "id": "room-200",
      "label": "200 Elevator lobby floor / ceiling",
      "quantity": 211.19584983994685,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1370,
            611
          ],
          [
            1445,
            611
          ],
          [
            1445,
            701
          ],
          [
            1429,
            701
          ],
          [
            1429,
            746
          ],
          [
            1370,
            746
          ]
        ]
      ]
    },
    {
      "id": "walls-200",
      "label": "200 Elevator lobby gross wall faces",
      "quantity": 62.9379481519076,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1370,
            611
          ],
          [
            1445,
            611
          ],
          [
            1445,
            701
          ],
          [
            1429,
            701
          ],
          [
            1429,
            746
          ],
          [
            1370,
            746
          ]
        ]
      ]
    },
    {
      "id": "room-201",
      "label": "201 King studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            354,
            556
          ],
          [
            429,
            556
          ],
          [
            429,
            746
          ],
          [
            354,
            746
          ]
        ]
      ]
    },
    {
      "id": "walls-201",
      "label": "201 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            354,
            556
          ],
          [
            429,
            556
          ],
          [
            429,
            746
          ],
          [
            354,
            746
          ]
        ]
      ]
    },
    {
      "id": "room-202",
      "label": "202 King one-bedroom floor / ceiling",
      "quantity": 517.4242181830999,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            354,
            852
          ],
          [
            472,
            852
          ],
          [
            472,
            791
          ],
          [
            514,
            791
          ],
          [
            514,
            980
          ],
          [
            354,
            980
          ]
        ]
      ]
    },
    {
      "id": "walls-202",
      "label": "202 King one-bedroom gross wall faces",
      "quantity": 104.59687573817024,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            354,
            852
          ],
          [
            472,
            852
          ],
          [
            472,
            791
          ],
          [
            514,
            791
          ],
          [
            514,
            980
          ],
          [
            354,
            980
          ]
        ]
      ]
    },
    {
      "id": "room-203",
      "label": "203 King studio floor / ceiling",
      "quantity": 328.5268775288062,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            438,
            556
          ],
          [
            515,
            556
          ],
          [
            515,
            746
          ],
          [
            438,
            746
          ]
        ]
      ]
    },
    {
      "id": "walls-203",
      "label": "203 King studio gross wall faces",
      "quantity": 80.02110550742537,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            438,
            556
          ],
          [
            515,
            556
          ],
          [
            515,
            746
          ],
          [
            438,
            746
          ]
        ]
      ]
    },
    {
      "id": "room-204",
      "label": "204 King studio floor / ceiling",
      "quantity": 318.3095344477668,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            524,
            791
          ],
          [
            599,
            791
          ],
          [
            599,
            980
          ],
          [
            524,
            980
          ]
        ]
      ]
    },
    {
      "id": "walls-204",
      "label": "204 King studio gross wall faces",
      "quantity": 79.12199196239813,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            524,
            791
          ],
          [
            599,
            791
          ],
          [
            599,
            980
          ],
          [
            524,
            980
          ]
        ]
      ]
    },
    {
      "id": "room-205",
      "label": "205 Connecting king studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            524,
            556
          ],
          [
            599,
            556
          ],
          [
            599,
            746
          ],
          [
            524,
            746
          ]
        ]
      ]
    },
    {
      "id": "walls-205",
      "label": "205 Connecting king studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            524,
            556
          ],
          [
            599,
            556
          ],
          [
            599,
            746
          ],
          [
            524,
            746
          ]
        ]
      ]
    },
    {
      "id": "room-206",
      "label": "206 King studio floor / ceiling",
      "quantity": 322.55366157373703,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            608,
            791
          ],
          [
            684,
            791
          ],
          [
            684,
            980
          ],
          [
            608,
            980
          ]
        ]
      ]
    },
    {
      "id": "walls-206",
      "label": "206 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            608,
            791
          ],
          [
            684,
            791
          ],
          [
            684,
            980
          ],
          [
            608,
            980
          ]
        ]
      ]
    },
    {
      "id": "room-207",
      "label": "207 Accessible king one-bedroom floor / ceiling",
      "quantity": 556.9013371643468,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            609,
            591
          ],
          [
            769,
            591
          ],
          [
            769,
            746
          ],
          [
            609,
            746
          ]
        ]
      ]
    },
    {
      "id": "walls-207",
      "label": "207 Accessible king one-bedroom gross wall faces",
      "quantity": 94.4069222278614,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            609,
            591
          ],
          [
            769,
            591
          ],
          [
            769,
            746
          ],
          [
            609,
            746
          ]
        ]
      ]
    },
    {
      "id": "room-208",
      "label": "208 King studio floor / ceiling",
      "quantity": 322.55366157373703,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            693,
            791
          ],
          [
            769,
            791
          ],
          [
            769,
            980
          ],
          [
            693,
            980
          ]
        ]
      ]
    },
    {
      "id": "walls-208",
      "label": "208 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            693,
            791
          ],
          [
            769,
            791
          ],
          [
            769,
            980
          ],
          [
            693,
            980
          ]
        ]
      ]
    },
    {
      "id": "room-209",
      "label": "209 King studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            778,
            556
          ],
          [
            853,
            556
          ],
          [
            853,
            746
          ],
          [
            778,
            746
          ]
        ]
      ]
    },
    {
      "id": "walls-209",
      "label": "209 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            778,
            556
          ],
          [
            853,
            556
          ],
          [
            853,
            746
          ],
          [
            778,
            746
          ]
        ]
      ]
    },
    {
      "id": "room-210",
      "label": "210 King studio floor / ceiling",
      "quantity": 318.3095344477668,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            778,
            791
          ],
          [
            853,
            791
          ],
          [
            853,
            980
          ],
          [
            778,
            980
          ]
        ]
      ]
    },
    {
      "id": "walls-210",
      "label": "210 King studio gross wall faces",
      "quantity": 79.12199196239813,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            778,
            791
          ],
          [
            853,
            791
          ],
          [
            853,
            980
          ],
          [
            778,
            980
          ]
        ]
      ]
    },
    {
      "id": "room-211",
      "label": "211 King studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            862,
            556
          ],
          [
            937,
            556
          ],
          [
            937,
            746
          ],
          [
            862,
            746
          ]
        ]
      ]
    },
    {
      "id": "walls-211",
      "label": "211 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            862,
            556
          ],
          [
            937,
            556
          ],
          [
            937,
            746
          ],
          [
            862,
            746
          ]
        ]
      ]
    },
    {
      "id": "room-212",
      "label": "212 King studio floor / ceiling",
      "quantity": 318.3095344477668,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            862,
            791
          ],
          [
            937,
            791
          ],
          [
            937,
            980
          ],
          [
            862,
            980
          ]
        ]
      ]
    },
    {
      "id": "walls-212",
      "label": "212 King studio gross wall faces",
      "quantity": 79.12199196239813,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            862,
            791
          ],
          [
            937,
            791
          ],
          [
            937,
            980
          ],
          [
            862,
            980
          ]
        ]
      ]
    },
    {
      "id": "room-213",
      "label": "213 King studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            947,
            556
          ],
          [
            1022,
            556
          ],
          [
            1022,
            746
          ],
          [
            947,
            746
          ]
        ]
      ]
    },
    {
      "id": "walls-213",
      "label": "213 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            947,
            556
          ],
          [
            1022,
            556
          ],
          [
            1022,
            746
          ],
          [
            947,
            746
          ]
        ]
      ]
    },
    {
      "id": "room-214",
      "label": "214 King studio floor / ceiling",
      "quantity": 318.3095344477668,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            947,
            791
          ],
          [
            1022,
            791
          ],
          [
            1022,
            980
          ],
          [
            947,
            980
          ]
        ]
      ]
    },
    {
      "id": "walls-214",
      "label": "214 King studio gross wall faces",
      "quantity": 79.12199196239813,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            947,
            791
          ],
          [
            1022,
            791
          ],
          [
            1022,
            980
          ],
          [
            947,
            980
          ]
        ]
      ]
    },
    {
      "id": "room-215",
      "label": "215 King studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1031,
            556
          ],
          [
            1106,
            556
          ],
          [
            1106,
            746
          ],
          [
            1031,
            746
          ]
        ]
      ]
    },
    {
      "id": "walls-215",
      "label": "215 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1031,
            556
          ],
          [
            1106,
            556
          ],
          [
            1106,
            746
          ],
          [
            1031,
            746
          ]
        ]
      ]
    },
    {
      "id": "room-216",
      "label": "216 Queen / queen floor / ceiling",
      "quantity": 380.53427659625083,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1032,
            791
          ],
          [
            1106,
            791
          ],
          [
            1106,
            1020
          ],
          [
            1032,
            1020
          ]
        ]
      ]
    },
    {
      "id": "walls-216",
      "label": "216 Queen / queen gross wall faces",
      "quantity": 90.8104680477524,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1032,
            791
          ],
          [
            1106,
            791
          ],
          [
            1106,
            1020
          ],
          [
            1032,
            1020
          ]
        ]
      ]
    },
    {
      "id": "room-217",
      "label": "217 King studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1116,
            556
          ],
          [
            1191,
            556
          ],
          [
            1191,
            746
          ],
          [
            1116,
            746
          ]
        ]
      ]
    },
    {
      "id": "walls-217",
      "label": "217 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1116,
            556
          ],
          [
            1191,
            556
          ],
          [
            1191,
            746
          ],
          [
            1116,
            746
          ]
        ]
      ]
    },
    {
      "id": "room-218",
      "label": "218 Queen / queen floor / ceiling",
      "quantity": 385.6766316853894,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1116,
            791
          ],
          [
            1191,
            791
          ],
          [
            1191,
            1020
          ],
          [
            1116,
            1020
          ]
        ]
      ]
    },
    {
      "id": "walls-218",
      "label": "218 Queen / queen gross wall faces",
      "quantity": 91.11017256276148,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1116,
            791
          ],
          [
            1191,
            791
          ],
          [
            1191,
            1020
          ],
          [
            1116,
            1020
          ]
        ]
      ]
    },
    {
      "id": "room-219",
      "label": "219 King studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1200,
            556
          ],
          [
            1275,
            556
          ],
          [
            1275,
            746
          ],
          [
            1200,
            746
          ]
        ]
      ]
    },
    {
      "id": "walls-219",
      "label": "219 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1200,
            556
          ],
          [
            1275,
            556
          ],
          [
            1275,
            746
          ],
          [
            1200,
            746
          ]
        ]
      ]
    },
    {
      "id": "room-220",
      "label": "220 Queen / queen floor / ceiling",
      "quantity": 385.6766316853894,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1200,
            791
          ],
          [
            1275,
            791
          ],
          [
            1275,
            1020
          ],
          [
            1200,
            1020
          ]
        ]
      ]
    },
    {
      "id": "walls-220",
      "label": "220 Queen / queen gross wall faces",
      "quantity": 91.11017256276148,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1200,
            791
          ],
          [
            1275,
            791
          ],
          [
            1275,
            1020
          ],
          [
            1200,
            1020
          ]
        ]
      ]
    },
    {
      "id": "room-221",
      "label": "221 King studio floor / ceiling",
      "quantity": 319.99371187870736,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1285,
            556
          ],
          [
            1360,
            556
          ],
          [
            1360,
            746
          ],
          [
            1285,
            746
          ]
        ]
      ]
    },
    {
      "id": "walls-221",
      "label": "221 King studio gross wall faces",
      "quantity": 79.42169647740721,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1285,
            556
          ],
          [
            1360,
            556
          ],
          [
            1360,
            746
          ],
          [
            1285,
            746
          ]
        ]
      ]
    },
    {
      "id": "room-222",
      "label": "222 Queen / queen floor / ceiling",
      "quantity": 385.6766316853894,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1285,
            791
          ],
          [
            1360,
            791
          ],
          [
            1360,
            1020
          ],
          [
            1285,
            1020
          ]
        ]
      ]
    },
    {
      "id": "walls-222",
      "label": "222 Queen / queen gross wall faces",
      "quantity": 91.11017256276148,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1285,
            791
          ],
          [
            1360,
            791
          ],
          [
            1360,
            1020
          ],
          [
            1285,
            1020
          ]
        ]
      ]
    },
    {
      "id": "room-223",
      "label": "223 Storage floor / ceiling",
      "quantity": 56.857830068553476,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1370,
            556
          ],
          [
            1387,
            556
          ],
          [
            1387,
            577
          ],
          [
            1445,
            577
          ],
          [
            1445,
            606
          ],
          [
            1370,
            606
          ]
        ]
      ]
    },
    {
      "id": "walls-223",
      "label": "223 Storage gross wall faces",
      "quantity": 37.46306437613548,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1370,
            556
          ],
          [
            1387,
            556
          ],
          [
            1387,
            577
          ],
          [
            1445,
            577
          ],
          [
            1445,
            606
          ],
          [
            1370,
            606
          ]
        ]
      ]
    },
    {
      "id": "room-224",
      "label": "224 Connecting queen / queen floor / ceiling",
      "quantity": 380.53427659625083,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1370,
            791
          ],
          [
            1444,
            791
          ],
          [
            1444,
            1020
          ],
          [
            1370,
            1020
          ]
        ]
      ]
    },
    {
      "id": "walls-224",
      "label": "224 Connecting queen / queen gross wall faces",
      "quantity": 90.8104680477524,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1370,
            791
          ],
          [
            1444,
            791
          ],
          [
            1444,
            1020
          ],
          [
            1370,
            1020
          ]
        ]
      ]
    },
    {
      "id": "room-226",
      "label": "226 Accessible queen / queen floor / ceiling",
      "quantity": 524.5202190921295,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            1454,
            791
          ],
          [
            1556,
            791
          ],
          [
            1556,
            1020
          ],
          [
            1454,
            1020
          ]
        ]
      ]
    },
    {
      "id": "walls-226",
      "label": "226 Accessible queen / queen gross wall faces",
      "quantity": 99.20219446800674,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            1454,
            791
          ],
          [
            1556,
            791
          ],
          [
            1556,
            1020
          ],
          [
            1454,
            1020
          ]
        ]
      ]
    },
    {
      "id": "room-228",
      "label": "228 Corridor floor / ceiling",
      "quantity": 804.8571663969564,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details.",
      "polygons": [
        [
          [
            354,
            755
          ],
          [
            1435,
            755
          ],
          [
            1435,
            727
          ],
          [
            1556,
            727
          ],
          [
            1556,
            782
          ],
          [
            354,
            782
          ]
        ]
      ]
    },
    {
      "id": "walls-228",
      "label": "228 Corridor gross wall faces",
      "quantity": 376.72857536641834,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details. Each room perimeter counts that room face; do not add room faces to unique framing runs.",
      "polygons": [
        [
          [
            354,
            755
          ],
          [
            1435,
            755
          ],
          [
            1435,
            727
          ],
          [
            1556,
            727
          ],
          [
            1556,
            782
          ],
          [
            354,
            782
          ]
        ]
      ]
    },
    {
      "id": "room-436",
      "label": "436 Room 436 \u00b7 label unresolved floor / ceiling",
      "quantity": 7.657393386009769,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Small outlined recess labeled Room 436 on the second floor. Usage and correct room number are unresolved.",
      "polygons": [
        [
          [
            1013,
            990
          ],
          [
            1024,
            990
          ],
          [
            1024,
            1021
          ],
          [
            1013,
            1021
          ]
        ]
      ]
    },
    {
      "id": "walls-436",
      "label": "436 Room 436 \u00b7 label unresolved gross wall faces",
      "quantity": 12.587589630381519,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Small outlined recess labeled Room 436 on the second floor. Usage and correct room number are unresolved.",
      "polygons": [
        [
          [
            1013,
            990
          ],
          [
            1024,
            990
          ],
          [
            1024,
            1021
          ],
          [
            1013,
            1021
          ]
        ]
      ]
    },
    {
      "id": "room-EL",
      "label": "EL Elevator core \u00b7 floor 2 floor / ceiling",
      "quantity": 99.43383552273096,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Floor-level core footprint; carries no finished-floor or ceiling assignment. Reconcile stair landings / shaft openings with details.",
      "polygons": [
        [
          [
            1453,
            604
          ],
          [
            1494,
            604
          ],
          [
            1494,
            712
          ],
          [
            1453,
            712
          ]
        ]
      ]
    },
    {
      "id": "walls-EL",
      "label": "EL Elevator core \u00b7 floor 2 gross wall faces",
      "quantity": 44.65597273635348,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Floor-level core footprint; carries no finished-floor or ceiling assignment. Reconcile stair landings / shaft openings with details.",
      "polygons": [
        [
          [
            1453,
            604
          ],
          [
            1494,
            604
          ],
          [
            1494,
            712
          ],
          [
            1453,
            712
          ]
        ]
      ]
    },
    {
      "id": "bath-201",
      "label": "201 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            354,
            696
          ],
          [
            395,
            696
          ],
          [
            395,
            746
          ],
          [
            354,
            746
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-201",
      "label": "201 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            354,
            696
          ],
          [
            395,
            696
          ],
          [
            395,
            746
          ],
          [
            354,
            746
          ]
        ]
      ]
    },
    {
      "id": "main-201",
      "label": "201 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            354,
            556
          ],
          [
            429,
            556
          ],
          [
            429,
            746
          ],
          [
            354,
            746
          ]
        ],
        [
          [
            354,
            696
          ],
          [
            395,
            696
          ],
          [
            395,
            746
          ],
          [
            354,
            746
          ]
        ]
      ]
    },
    {
      "id": "bath-203",
      "label": "203 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            474,
            696
          ],
          [
            515,
            696
          ],
          [
            515,
            746
          ],
          [
            474,
            746
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-203",
      "label": "203 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            474,
            696
          ],
          [
            515,
            696
          ],
          [
            515,
            746
          ],
          [
            474,
            746
          ]
        ]
      ]
    },
    {
      "id": "main-203",
      "label": "203 room outside bathroom",
      "quantity": 282.49269441643077,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            438,
            556
          ],
          [
            515,
            556
          ],
          [
            515,
            746
          ],
          [
            438,
            746
          ]
        ],
        [
          [
            474,
            696
          ],
          [
            515,
            696
          ],
          [
            515,
            746
          ],
          [
            474,
            746
          ]
        ]
      ]
    },
    {
      "id": "bath-205",
      "label": "205 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            524,
            696
          ],
          [
            565,
            696
          ],
          [
            565,
            746
          ],
          [
            524,
            746
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-205",
      "label": "205 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            524,
            696
          ],
          [
            565,
            696
          ],
          [
            565,
            746
          ],
          [
            524,
            746
          ]
        ]
      ]
    },
    {
      "id": "main-205",
      "label": "205 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            524,
            556
          ],
          [
            599,
            556
          ],
          [
            599,
            746
          ],
          [
            524,
            746
          ]
        ],
        [
          [
            524,
            696
          ],
          [
            565,
            696
          ],
          [
            565,
            746
          ],
          [
            524,
            746
          ]
        ]
      ]
    },
    {
      "id": "bath-209",
      "label": "209 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            812,
            696
          ],
          [
            853,
            696
          ],
          [
            853,
            746
          ],
          [
            812,
            746
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-209",
      "label": "209 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            812,
            696
          ],
          [
            853,
            696
          ],
          [
            853,
            746
          ],
          [
            812,
            746
          ]
        ]
      ]
    },
    {
      "id": "main-209",
      "label": "209 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            778,
            556
          ],
          [
            853,
            556
          ],
          [
            853,
            746
          ],
          [
            778,
            746
          ]
        ],
        [
          [
            812,
            696
          ],
          [
            853,
            696
          ],
          [
            853,
            746
          ],
          [
            812,
            746
          ]
        ]
      ]
    },
    {
      "id": "bath-211",
      "label": "211 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            862,
            696
          ],
          [
            903,
            696
          ],
          [
            903,
            746
          ],
          [
            862,
            746
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-211",
      "label": "211 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            862,
            696
          ],
          [
            903,
            696
          ],
          [
            903,
            746
          ],
          [
            862,
            746
          ]
        ]
      ]
    },
    {
      "id": "main-211",
      "label": "211 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            862,
            556
          ],
          [
            937,
            556
          ],
          [
            937,
            746
          ],
          [
            862,
            746
          ]
        ],
        [
          [
            862,
            696
          ],
          [
            903,
            696
          ],
          [
            903,
            746
          ],
          [
            862,
            746
          ]
        ]
      ]
    },
    {
      "id": "bath-213",
      "label": "213 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            981,
            696
          ],
          [
            1022,
            696
          ],
          [
            1022,
            746
          ],
          [
            981,
            746
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-213",
      "label": "213 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            981,
            696
          ],
          [
            1022,
            696
          ],
          [
            1022,
            746
          ],
          [
            981,
            746
          ]
        ]
      ]
    },
    {
      "id": "main-213",
      "label": "213 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            947,
            556
          ],
          [
            1022,
            556
          ],
          [
            1022,
            746
          ],
          [
            947,
            746
          ]
        ],
        [
          [
            981,
            696
          ],
          [
            1022,
            696
          ],
          [
            1022,
            746
          ],
          [
            981,
            746
          ]
        ]
      ]
    },
    {
      "id": "bath-215",
      "label": "215 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1031,
            696
          ],
          [
            1072,
            696
          ],
          [
            1072,
            746
          ],
          [
            1031,
            746
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-215",
      "label": "215 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1031,
            696
          ],
          [
            1072,
            696
          ],
          [
            1072,
            746
          ],
          [
            1031,
            746
          ]
        ]
      ]
    },
    {
      "id": "main-215",
      "label": "215 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1031,
            556
          ],
          [
            1106,
            556
          ],
          [
            1106,
            746
          ],
          [
            1031,
            746
          ]
        ],
        [
          [
            1031,
            696
          ],
          [
            1072,
            696
          ],
          [
            1072,
            746
          ],
          [
            1031,
            746
          ]
        ]
      ]
    },
    {
      "id": "bath-217",
      "label": "217 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1150,
            696
          ],
          [
            1191,
            696
          ],
          [
            1191,
            746
          ],
          [
            1150,
            746
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-217",
      "label": "217 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1150,
            696
          ],
          [
            1191,
            696
          ],
          [
            1191,
            746
          ],
          [
            1150,
            746
          ]
        ]
      ]
    },
    {
      "id": "main-217",
      "label": "217 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1116,
            556
          ],
          [
            1191,
            556
          ],
          [
            1191,
            746
          ],
          [
            1116,
            746
          ]
        ],
        [
          [
            1150,
            696
          ],
          [
            1191,
            696
          ],
          [
            1191,
            746
          ],
          [
            1150,
            746
          ]
        ]
      ]
    },
    {
      "id": "bath-219",
      "label": "219 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1200,
            696
          ],
          [
            1241,
            696
          ],
          [
            1241,
            746
          ],
          [
            1200,
            746
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-219",
      "label": "219 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1200,
            696
          ],
          [
            1241,
            696
          ],
          [
            1241,
            746
          ],
          [
            1200,
            746
          ]
        ]
      ]
    },
    {
      "id": "main-219",
      "label": "219 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1200,
            556
          ],
          [
            1275,
            556
          ],
          [
            1275,
            746
          ],
          [
            1200,
            746
          ]
        ],
        [
          [
            1200,
            696
          ],
          [
            1241,
            696
          ],
          [
            1241,
            746
          ],
          [
            1200,
            746
          ]
        ]
      ]
    },
    {
      "id": "bath-221",
      "label": "221 bathroom zone",
      "quantity": 46.034183112375445,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1319,
            696
          ],
          [
            1360,
            696
          ],
          [
            1360,
            746
          ],
          [
            1319,
            746
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-221",
      "label": "221 bathroom wall faces",
      "quantity": 27.273110865826627,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1319,
            696
          ],
          [
            1360,
            696
          ],
          [
            1360,
            746
          ],
          [
            1319,
            746
          ]
        ]
      ]
    },
    {
      "id": "main-221",
      "label": "221 room outside bathroom",
      "quantity": 273.9595287663319,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1285,
            556
          ],
          [
            1360,
            556
          ],
          [
            1360,
            746
          ],
          [
            1285,
            746
          ]
        ],
        [
          [
            1319,
            696
          ],
          [
            1360,
            696
          ],
          [
            1360,
            746
          ],
          [
            1319,
            746
          ]
        ]
      ]
    },
    {
      "id": "bath-204",
      "label": "204 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            524,
            791
          ],
          [
            565,
            791
          ],
          [
            565,
            845
          ],
          [
            524,
            845
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-204",
      "label": "204 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            524,
            791
          ],
          [
            565,
            791
          ],
          [
            565,
            845
          ],
          [
            524,
            845
          ]
        ]
      ]
    },
    {
      "id": "main-204",
      "label": "204 room outside bathroom",
      "quantity": 268.5926166864013,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            524,
            791
          ],
          [
            599,
            791
          ],
          [
            599,
            980
          ],
          [
            524,
            980
          ]
        ],
        [
          [
            524,
            791
          ],
          [
            565,
            791
          ],
          [
            565,
            845
          ],
          [
            524,
            845
          ]
        ]
      ]
    },
    {
      "id": "bath-206",
      "label": "206 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            643,
            791
          ],
          [
            684,
            791
          ],
          [
            684,
            845
          ],
          [
            643,
            845
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-206",
      "label": "206 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            643,
            791
          ],
          [
            684,
            791
          ],
          [
            684,
            845
          ],
          [
            643,
            845
          ]
        ]
      ]
    },
    {
      "id": "main-206",
      "label": "206 room outside bathroom",
      "quantity": 272.83674381237154,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            608,
            791
          ],
          [
            684,
            791
          ],
          [
            684,
            980
          ],
          [
            608,
            980
          ]
        ],
        [
          [
            643,
            791
          ],
          [
            684,
            791
          ],
          [
            684,
            845
          ],
          [
            643,
            845
          ]
        ]
      ]
    },
    {
      "id": "bath-208",
      "label": "208 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            693,
            791
          ],
          [
            734,
            791
          ],
          [
            734,
            845
          ],
          [
            693,
            845
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-208",
      "label": "208 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            693,
            791
          ],
          [
            734,
            791
          ],
          [
            734,
            845
          ],
          [
            693,
            845
          ]
        ]
      ]
    },
    {
      "id": "main-208",
      "label": "208 room outside bathroom",
      "quantity": 272.83674381237154,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            693,
            791
          ],
          [
            769,
            791
          ],
          [
            769,
            980
          ],
          [
            693,
            980
          ]
        ],
        [
          [
            693,
            791
          ],
          [
            734,
            791
          ],
          [
            734,
            845
          ],
          [
            693,
            845
          ]
        ]
      ]
    },
    {
      "id": "bath-210",
      "label": "210 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            812,
            791
          ],
          [
            853,
            791
          ],
          [
            853,
            845
          ],
          [
            812,
            845
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-210",
      "label": "210 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            812,
            791
          ],
          [
            853,
            791
          ],
          [
            853,
            845
          ],
          [
            812,
            845
          ]
        ]
      ]
    },
    {
      "id": "main-210",
      "label": "210 room outside bathroom",
      "quantity": 268.5926166864013,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            778,
            791
          ],
          [
            853,
            791
          ],
          [
            853,
            980
          ],
          [
            778,
            980
          ]
        ],
        [
          [
            812,
            791
          ],
          [
            853,
            791
          ],
          [
            853,
            845
          ],
          [
            812,
            845
          ]
        ]
      ]
    },
    {
      "id": "bath-212",
      "label": "212 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            862,
            791
          ],
          [
            903,
            791
          ],
          [
            903,
            845
          ],
          [
            862,
            845
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-212",
      "label": "212 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            862,
            791
          ],
          [
            903,
            791
          ],
          [
            903,
            845
          ],
          [
            862,
            845
          ]
        ]
      ]
    },
    {
      "id": "main-212",
      "label": "212 room outside bathroom",
      "quantity": 268.5926166864013,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            862,
            791
          ],
          [
            937,
            791
          ],
          [
            937,
            980
          ],
          [
            862,
            980
          ]
        ],
        [
          [
            862,
            791
          ],
          [
            903,
            791
          ],
          [
            903,
            845
          ],
          [
            862,
            845
          ]
        ]
      ]
    },
    {
      "id": "bath-214",
      "label": "214 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            981,
            791
          ],
          [
            1022,
            791
          ],
          [
            1022,
            845
          ],
          [
            981,
            845
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-214",
      "label": "214 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            981,
            791
          ],
          [
            1022,
            791
          ],
          [
            1022,
            845
          ],
          [
            981,
            845
          ]
        ]
      ]
    },
    {
      "id": "main-214",
      "label": "214 room outside bathroom",
      "quantity": 268.5926166864013,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            947,
            791
          ],
          [
            1022,
            791
          ],
          [
            1022,
            980
          ],
          [
            947,
            980
          ]
        ],
        [
          [
            981,
            791
          ],
          [
            1022,
            791
          ],
          [
            1022,
            845
          ],
          [
            981,
            845
          ]
        ]
      ]
    },
    {
      "id": "bath-216",
      "label": "216 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1065,
            791
          ],
          [
            1106,
            791
          ],
          [
            1106,
            845
          ],
          [
            1065,
            845
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-216",
      "label": "216 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1065,
            791
          ],
          [
            1106,
            791
          ],
          [
            1106,
            845
          ],
          [
            1065,
            845
          ]
        ]
      ]
    },
    {
      "id": "main-216",
      "label": "216 room outside bathroom",
      "quantity": 330.81735883488534,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1032,
            791
          ],
          [
            1106,
            791
          ],
          [
            1106,
            1020
          ],
          [
            1032,
            1020
          ]
        ],
        [
          [
            1065,
            791
          ],
          [
            1106,
            791
          ],
          [
            1106,
            845
          ],
          [
            1065,
            845
          ]
        ]
      ]
    },
    {
      "id": "bath-218",
      "label": "218 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1116,
            791
          ],
          [
            1157,
            791
          ],
          [
            1157,
            845
          ],
          [
            1116,
            845
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-218",
      "label": "218 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1116,
            791
          ],
          [
            1157,
            791
          ],
          [
            1157,
            845
          ],
          [
            1116,
            845
          ]
        ]
      ]
    },
    {
      "id": "main-218",
      "label": "218 room outside bathroom",
      "quantity": 335.9597139240239,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1116,
            791
          ],
          [
            1191,
            791
          ],
          [
            1191,
            1020
          ],
          [
            1116,
            1020
          ]
        ],
        [
          [
            1116,
            791
          ],
          [
            1157,
            791
          ],
          [
            1157,
            845
          ],
          [
            1116,
            845
          ]
        ]
      ]
    },
    {
      "id": "bath-220",
      "label": "220 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1234,
            791
          ],
          [
            1275,
            791
          ],
          [
            1275,
            845
          ],
          [
            1234,
            845
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-220",
      "label": "220 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1234,
            791
          ],
          [
            1275,
            791
          ],
          [
            1275,
            845
          ],
          [
            1234,
            845
          ]
        ]
      ]
    },
    {
      "id": "main-220",
      "label": "220 room outside bathroom",
      "quantity": 335.9597139240239,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1200,
            791
          ],
          [
            1275,
            791
          ],
          [
            1275,
            1020
          ],
          [
            1200,
            1020
          ]
        ],
        [
          [
            1234,
            791
          ],
          [
            1275,
            791
          ],
          [
            1275,
            845
          ],
          [
            1234,
            845
          ]
        ]
      ]
    },
    {
      "id": "bath-222",
      "label": "222 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1285,
            791
          ],
          [
            1326,
            791
          ],
          [
            1326,
            845
          ],
          [
            1285,
            845
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-222",
      "label": "222 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1285,
            791
          ],
          [
            1326,
            791
          ],
          [
            1326,
            845
          ],
          [
            1285,
            845
          ]
        ]
      ]
    },
    {
      "id": "main-222",
      "label": "222 room outside bathroom",
      "quantity": 335.9597139240239,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1285,
            791
          ],
          [
            1360,
            791
          ],
          [
            1360,
            1020
          ],
          [
            1285,
            1020
          ]
        ],
        [
          [
            1285,
            791
          ],
          [
            1326,
            791
          ],
          [
            1326,
            845
          ],
          [
            1285,
            845
          ]
        ]
      ]
    },
    {
      "id": "bath-224",
      "label": "224 bathroom zone",
      "quantity": 49.71691776136548,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1403,
            791
          ],
          [
            1444,
            791
          ],
          [
            1444,
            845
          ],
          [
            1403,
            845
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-224",
      "label": "224 bathroom wall faces",
      "quantity": 28.47192892586296,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1403,
            791
          ],
          [
            1444,
            791
          ],
          [
            1444,
            845
          ],
          [
            1403,
            845
          ]
        ]
      ]
    },
    {
      "id": "main-224",
      "label": "224 room outside bathroom",
      "quantity": 330.81735883488534,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1370,
            791
          ],
          [
            1444,
            791
          ],
          [
            1444,
            1020
          ],
          [
            1370,
            1020
          ]
        ],
        [
          [
            1403,
            791
          ],
          [
            1444,
            791
          ],
          [
            1444,
            845
          ],
          [
            1403,
            845
          ]
        ]
      ]
    },
    {
      "id": "bath-207",
      "label": "207 bathroom zone",
      "quantity": 87.0382896310084,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            693,
            695
          ],
          [
            769,
            695
          ],
          [
            769,
            746
          ],
          [
            693,
            746
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-207",
      "label": "207 bathroom wall faces",
      "quantity": 38.06247340615364,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            693,
            695
          ],
          [
            769,
            695
          ],
          [
            769,
            746
          ],
          [
            693,
            746
          ]
        ]
      ]
    },
    {
      "id": "main-207",
      "label": "207 room outside bathroom",
      "quantity": 469.86304753333843,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            609,
            591
          ],
          [
            769,
            591
          ],
          [
            769,
            746
          ],
          [
            609,
            746
          ]
        ],
        [
          [
            693,
            695
          ],
          [
            769,
            695
          ],
          [
            769,
            746
          ],
          [
            693,
            746
          ]
        ]
      ]
    },
    {
      "id": "bath-202",
      "label": "202 bathroom zone",
      "quantity": 68.13059100631565,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            354,
            852
          ],
          [
            428,
            852
          ],
          [
            428,
            893
          ],
          [
            354,
            893
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-202",
      "label": "202 bathroom wall faces",
      "quantity": 34.46601922604464,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            354,
            852
          ],
          [
            428,
            852
          ],
          [
            428,
            893
          ],
          [
            354,
            893
          ]
        ]
      ]
    },
    {
      "id": "main-202",
      "label": "202 room outside bathroom",
      "quantity": 449.2936271767843,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            354,
            852
          ],
          [
            472,
            852
          ],
          [
            472,
            791
          ],
          [
            514,
            791
          ],
          [
            514,
            980
          ],
          [
            354,
            980
          ]
        ],
        [
          [
            354,
            852
          ],
          [
            428,
            852
          ],
          [
            428,
            893
          ],
          [
            354,
            893
          ]
        ]
      ]
    },
    {
      "id": "bath-226",
      "label": "226 bathroom zone",
      "quantity": 67.83866691828595,
      "unit": "SF",
      "color": "#687cc4",
      "basis": "Bathroom zone traced inside surrounding walls; includes bath/shower footprint. Subset of the guestroom footprint, not additional floor area.",
      "polygons": [
        [
          [
            1499,
            791
          ],
          [
            1556,
            791
          ],
          [
            1556,
            844
          ],
          [
            1499,
            844
          ]
        ]
      ]
    },
    {
      "id": "bath-walls-226",
      "label": "226 bathroom wall faces",
      "quantity": 32.967496650999216,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Gross bathroom perimeter before door/opening deductions; use finish heights from enlarged details. Face quantity includes walls shared with the room/exterior.",
      "polygons": [
        [
          [
            1499,
            791
          ],
          [
            1556,
            791
          ],
          [
            1556,
            844
          ],
          [
            1499,
            844
          ]
        ]
      ]
    },
    {
      "id": "main-226",
      "label": "226 room outside bathroom",
      "quantity": 456.68155217384356,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Guestroom enclosing footprint less the bathroom zone. Contains internal partition/closet footprints; resolve exact carpet/resilient/tile breaks on finish plans.",
      "polygons": [
        [
          [
            1454,
            791
          ],
          [
            1556,
            791
          ],
          [
            1556,
            1020
          ],
          [
            1454,
            1020
          ]
        ],
        [
          [
            1499,
            791
          ],
          [
            1556,
            791
          ],
          [
            1556,
            844
          ],
          [
            1499,
            844
          ]
        ]
      ]
    }
  ],
  "roomRegister": [
    {
      "id": "001",
      "name": "East Stair 1 \u00b7 floor 2",
      "kind": "stair",
      "polygon": [
        [
          1504,
          604
        ],
        [
          1556,
          604
        ],
        [
          1556,
          715
        ],
        [
          1504,
          715
        ]
      ],
      "floorFootprintSF": 129.6142950851859,
      "ceilingFootprintSF": 129.6142950851859,
      "grossWallFaceRunLF": 48.85183594648066,
      "scopeKey": "bradenton/floor2/room001",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "002",
      "name": "West Stair 2 \u00b7 floor 2",
      "kind": "stair",
      "polygon": [
        [
          354,
          791
        ],
        [
          468,
          791
        ],
        [
          468,
          843
        ],
        [
          354,
          843
        ]
      ],
      "floorFootprintSF": 133.11738414154226,
      "ceilingFootprintSF": 133.11738414154226,
      "grossWallFaceRunLF": 49.75094949150791,
      "scopeKey": "bradenton/floor2/room002",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "200",
      "name": "Elevator lobby",
      "kind": "enclosed",
      "polygon": [
        [
          1370,
          611
        ],
        [
          1445,
          611
        ],
        [
          1445,
          701
        ],
        [
          1429,
          701
        ],
        [
          1429,
          746
        ],
        [
          1370,
          746
        ]
      ],
      "floorFootprintSF": 211.19584983994685,
      "ceilingFootprintSF": 211.19584983994685,
      "grossWallFaceRunLF": 62.9379481519076,
      "scopeKey": "bradenton/floor2/room200",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "201",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          354,
          556
        ],
        [
          429,
          556
        ],
        [
          429,
          746
        ],
        [
          354,
          746
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor2/room201",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "202",
      "name": "King one-bedroom",
      "kind": "enclosed",
      "polygon": [
        [
          354,
          852
        ],
        [
          472,
          852
        ],
        [
          472,
          791
        ],
        [
          514,
          791
        ],
        [
          514,
          980
        ],
        [
          354,
          980
        ]
      ],
      "floorFootprintSF": 517.4242181830999,
      "ceilingFootprintSF": 517.4242181830999,
      "grossWallFaceRunLF": 104.59687573817024,
      "scopeKey": "bradenton/floor2/room202",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "203",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          438,
          556
        ],
        [
          515,
          556
        ],
        [
          515,
          746
        ],
        [
          438,
          746
        ]
      ],
      "floorFootprintSF": 328.5268775288062,
      "ceilingFootprintSF": 328.5268775288062,
      "grossWallFaceRunLF": 80.02110550742537,
      "scopeKey": "bradenton/floor2/room203",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "204",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          524,
          791
        ],
        [
          599,
          791
        ],
        [
          599,
          980
        ],
        [
          524,
          980
        ]
      ],
      "floorFootprintSF": 318.3095344477668,
      "ceilingFootprintSF": 318.3095344477668,
      "grossWallFaceRunLF": 79.12199196239813,
      "scopeKey": "bradenton/floor2/room204",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "205",
      "name": "Connecting king studio",
      "kind": "enclosed",
      "polygon": [
        [
          524,
          556
        ],
        [
          599,
          556
        ],
        [
          599,
          746
        ],
        [
          524,
          746
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor2/room205",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "206",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          608,
          791
        ],
        [
          684,
          791
        ],
        [
          684,
          980
        ],
        [
          608,
          980
        ]
      ],
      "floorFootprintSF": 322.55366157373703,
      "ceilingFootprintSF": 322.55366157373703,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor2/room206",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "207",
      "name": "Accessible king one-bedroom",
      "kind": "enclosed",
      "polygon": [
        [
          609,
          591
        ],
        [
          769,
          591
        ],
        [
          769,
          746
        ],
        [
          609,
          746
        ]
      ],
      "floorFootprintSF": 556.9013371643468,
      "ceilingFootprintSF": 556.9013371643468,
      "grossWallFaceRunLF": 94.4069222278614,
      "scopeKey": "bradenton/floor2/room207",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "208",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          693,
          791
        ],
        [
          769,
          791
        ],
        [
          769,
          980
        ],
        [
          693,
          980
        ]
      ],
      "floorFootprintSF": 322.55366157373703,
      "ceilingFootprintSF": 322.55366157373703,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor2/room208",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "209",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          778,
          556
        ],
        [
          853,
          556
        ],
        [
          853,
          746
        ],
        [
          778,
          746
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor2/room209",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "210",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          778,
          791
        ],
        [
          853,
          791
        ],
        [
          853,
          980
        ],
        [
          778,
          980
        ]
      ],
      "floorFootprintSF": 318.3095344477668,
      "ceilingFootprintSF": 318.3095344477668,
      "grossWallFaceRunLF": 79.12199196239813,
      "scopeKey": "bradenton/floor2/room210",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "211",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          862,
          556
        ],
        [
          937,
          556
        ],
        [
          937,
          746
        ],
        [
          862,
          746
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor2/room211",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "212",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          862,
          791
        ],
        [
          937,
          791
        ],
        [
          937,
          980
        ],
        [
          862,
          980
        ]
      ],
      "floorFootprintSF": 318.3095344477668,
      "ceilingFootprintSF": 318.3095344477668,
      "grossWallFaceRunLF": 79.12199196239813,
      "scopeKey": "bradenton/floor2/room212",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "213",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          947,
          556
        ],
        [
          1022,
          556
        ],
        [
          1022,
          746
        ],
        [
          947,
          746
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor2/room213",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "214",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          947,
          791
        ],
        [
          1022,
          791
        ],
        [
          1022,
          980
        ],
        [
          947,
          980
        ]
      ],
      "floorFootprintSF": 318.3095344477668,
      "ceilingFootprintSF": 318.3095344477668,
      "grossWallFaceRunLF": 79.12199196239813,
      "scopeKey": "bradenton/floor2/room214",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "215",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          1031,
          556
        ],
        [
          1106,
          556
        ],
        [
          1106,
          746
        ],
        [
          1031,
          746
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor2/room215",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "216",
      "name": "Queen / queen",
      "kind": "enclosed",
      "polygon": [
        [
          1032,
          791
        ],
        [
          1106,
          791
        ],
        [
          1106,
          1020
        ],
        [
          1032,
          1020
        ]
      ],
      "floorFootprintSF": 380.53427659625083,
      "ceilingFootprintSF": 380.53427659625083,
      "grossWallFaceRunLF": 90.8104680477524,
      "scopeKey": "bradenton/floor2/room216",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "217",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          1116,
          556
        ],
        [
          1191,
          556
        ],
        [
          1191,
          746
        ],
        [
          1116,
          746
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor2/room217",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "218",
      "name": "Queen / queen",
      "kind": "enclosed",
      "polygon": [
        [
          1116,
          791
        ],
        [
          1191,
          791
        ],
        [
          1191,
          1020
        ],
        [
          1116,
          1020
        ]
      ],
      "floorFootprintSF": 385.6766316853894,
      "ceilingFootprintSF": 385.6766316853894,
      "grossWallFaceRunLF": 91.11017256276148,
      "scopeKey": "bradenton/floor2/room218",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "219",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          1200,
          556
        ],
        [
          1275,
          556
        ],
        [
          1275,
          746
        ],
        [
          1200,
          746
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor2/room219",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "220",
      "name": "Queen / queen",
      "kind": "enclosed",
      "polygon": [
        [
          1200,
          791
        ],
        [
          1275,
          791
        ],
        [
          1275,
          1020
        ],
        [
          1200,
          1020
        ]
      ],
      "floorFootprintSF": 385.6766316853894,
      "ceilingFootprintSF": 385.6766316853894,
      "grossWallFaceRunLF": 91.11017256276148,
      "scopeKey": "bradenton/floor2/room220",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "221",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          1285,
          556
        ],
        [
          1360,
          556
        ],
        [
          1360,
          746
        ],
        [
          1285,
          746
        ]
      ],
      "floorFootprintSF": 319.99371187870736,
      "ceilingFootprintSF": 319.99371187870736,
      "grossWallFaceRunLF": 79.42169647740721,
      "scopeKey": "bradenton/floor2/room221",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "222",
      "name": "Queen / queen",
      "kind": "enclosed",
      "polygon": [
        [
          1285,
          791
        ],
        [
          1360,
          791
        ],
        [
          1360,
          1020
        ],
        [
          1285,
          1020
        ]
      ],
      "floorFootprintSF": 385.6766316853894,
      "ceilingFootprintSF": 385.6766316853894,
      "grossWallFaceRunLF": 91.11017256276148,
      "scopeKey": "bradenton/floor2/room222",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "223",
      "name": "Storage",
      "kind": "enclosed",
      "polygon": [
        [
          1370,
          556
        ],
        [
          1387,
          556
        ],
        [
          1387,
          577
        ],
        [
          1445,
          577
        ],
        [
          1445,
          606
        ],
        [
          1370,
          606
        ]
      ],
      "floorFootprintSF": 56.857830068553476,
      "ceilingFootprintSF": 56.857830068553476,
      "grossWallFaceRunLF": 37.46306437613548,
      "scopeKey": "bradenton/floor2/room223",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "224",
      "name": "Connecting queen / queen",
      "kind": "enclosed",
      "polygon": [
        [
          1370,
          791
        ],
        [
          1444,
          791
        ],
        [
          1444,
          1020
        ],
        [
          1370,
          1020
        ]
      ],
      "floorFootprintSF": 380.53427659625083,
      "ceilingFootprintSF": 380.53427659625083,
      "grossWallFaceRunLF": 90.8104680477524,
      "scopeKey": "bradenton/floor2/room224",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "226",
      "name": "Accessible queen / queen",
      "kind": "enclosed",
      "polygon": [
        [
          1454,
          791
        ],
        [
          1556,
          791
        ],
        [
          1556,
          1020
        ],
        [
          1454,
          1020
        ]
      ],
      "floorFootprintSF": 524.5202190921295,
      "ceilingFootprintSF": 524.5202190921295,
      "grossWallFaceRunLF": 99.20219446800674,
      "scopeKey": "bradenton/floor2/room226",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "228",
      "name": "Corridor",
      "kind": "enclosed",
      "polygon": [
        [
          354,
          755
        ],
        [
          1435,
          755
        ],
        [
          1435,
          727
        ],
        [
          1556,
          727
        ],
        [
          1556,
          782
        ],
        [
          354,
          782
        ]
      ],
      "floorFootprintSF": 804.8571663969564,
      "ceilingFootprintSF": 804.8571663969564,
      "grossWallFaceRunLF": 376.72857536641834,
      "scopeKey": "bradenton/floor2/room228",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "436",
      "name": "Room 436 \u00b7 label unresolved",
      "kind": "unresolved",
      "polygon": [
        [
          1013,
          990
        ],
        [
          1024,
          990
        ],
        [
          1024,
          1021
        ],
        [
          1013,
          1021
        ]
      ],
      "floorFootprintSF": 7.657393386009769,
      "ceilingFootprintSF": 7.657393386009769,
      "grossWallFaceRunLF": 12.587589630381519,
      "scopeKey": "bradenton/floor2/room436",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    },
    {
      "id": "EL",
      "name": "Elevator core \u00b7 floor 2",
      "kind": "shaft",
      "polygon": [
        [
          1453,
          604
        ],
        [
          1494,
          604
        ],
        [
          1494,
          712
        ],
        [
          1453,
          712
        ]
      ],
      "floorFootprintSF": 99.43383552273096,
      "ceilingFootprintSF": 99.43383552273096,
      "grossWallFaceRunLF": 44.65597273635348,
      "scopeKey": "bradenton/floor2/roomEL",
      "basis": "Traced enclosing inside faces. Guest suites include internal partition footprints; finish-zone and opening deductions follow enlarged room details."
    }
  ],
  "bathroomZones": [
    {
      "room": "201",
      "polygon": [
        [
          354,
          696
        ],
        [
          395,
          696
        ],
        [
          395,
          746
        ],
        [
          354,
          746
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "203",
      "polygon": [
        [
          474,
          696
        ],
        [
          515,
          696
        ],
        [
          515,
          746
        ],
        [
          474,
          746
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "205",
      "polygon": [
        [
          524,
          696
        ],
        [
          565,
          696
        ],
        [
          565,
          746
        ],
        [
          524,
          746
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "209",
      "polygon": [
        [
          812,
          696
        ],
        [
          853,
          696
        ],
        [
          853,
          746
        ],
        [
          812,
          746
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "211",
      "polygon": [
        [
          862,
          696
        ],
        [
          903,
          696
        ],
        [
          903,
          746
        ],
        [
          862,
          746
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "213",
      "polygon": [
        [
          981,
          696
        ],
        [
          1022,
          696
        ],
        [
          1022,
          746
        ],
        [
          981,
          746
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "215",
      "polygon": [
        [
          1031,
          696
        ],
        [
          1072,
          696
        ],
        [
          1072,
          746
        ],
        [
          1031,
          746
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "217",
      "polygon": [
        [
          1150,
          696
        ],
        [
          1191,
          696
        ],
        [
          1191,
          746
        ],
        [
          1150,
          746
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "219",
      "polygon": [
        [
          1200,
          696
        ],
        [
          1241,
          696
        ],
        [
          1241,
          746
        ],
        [
          1200,
          746
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "221",
      "polygon": [
        [
          1319,
          696
        ],
        [
          1360,
          696
        ],
        [
          1360,
          746
        ],
        [
          1319,
          746
        ]
      ],
      "areaSF": 46.034183112375445
    },
    {
      "room": "204",
      "polygon": [
        [
          524,
          791
        ],
        [
          565,
          791
        ],
        [
          565,
          845
        ],
        [
          524,
          845
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "206",
      "polygon": [
        [
          643,
          791
        ],
        [
          684,
          791
        ],
        [
          684,
          845
        ],
        [
          643,
          845
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "208",
      "polygon": [
        [
          693,
          791
        ],
        [
          734,
          791
        ],
        [
          734,
          845
        ],
        [
          693,
          845
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "210",
      "polygon": [
        [
          812,
          791
        ],
        [
          853,
          791
        ],
        [
          853,
          845
        ],
        [
          812,
          845
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "212",
      "polygon": [
        [
          862,
          791
        ],
        [
          903,
          791
        ],
        [
          903,
          845
        ],
        [
          862,
          845
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "214",
      "polygon": [
        [
          981,
          791
        ],
        [
          1022,
          791
        ],
        [
          1022,
          845
        ],
        [
          981,
          845
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "216",
      "polygon": [
        [
          1065,
          791
        ],
        [
          1106,
          791
        ],
        [
          1106,
          845
        ],
        [
          1065,
          845
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "218",
      "polygon": [
        [
          1116,
          791
        ],
        [
          1157,
          791
        ],
        [
          1157,
          845
        ],
        [
          1116,
          845
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "220",
      "polygon": [
        [
          1234,
          791
        ],
        [
          1275,
          791
        ],
        [
          1275,
          845
        ],
        [
          1234,
          845
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "222",
      "polygon": [
        [
          1285,
          791
        ],
        [
          1326,
          791
        ],
        [
          1326,
          845
        ],
        [
          1285,
          845
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "224",
      "polygon": [
        [
          1403,
          791
        ],
        [
          1444,
          791
        ],
        [
          1444,
          845
        ],
        [
          1403,
          845
        ]
      ],
      "areaSF": 49.71691776136548
    },
    {
      "room": "207",
      "polygon": [
        [
          693,
          695
        ],
        [
          769,
          695
        ],
        [
          769,
          746
        ],
        [
          693,
          746
        ]
      ],
      "areaSF": 87.0382896310084
    },
    {
      "room": "202",
      "polygon": [
        [
          354,
          852
        ],
        [
          428,
          852
        ],
        [
          428,
          893
        ],
        [
          354,
          893
        ]
      ],
      "areaSF": 68.13059100631565
    },
    {
      "room": "226",
      "polygon": [
        [
          1499,
          791
        ],
        [
          1556,
          791
        ],
        [
          1556,
          844
        ],
        [
          1499,
          844
        ]
      ],
      "areaSF": 67.83866691828595
    }
  ],
  "wallAssignmentStatus": "No explicit W1\u2013W6 plan tags found. Keep exact assemblies unassigned while preserving separate corridor, party and exterior runs.",
  "reuseRule": "Room IDs are floor-qualified. Stair and elevator outlines continue building systems; do not create additional systems at every floor."
}