  "sheet": "A2.17",
  "coordinateSpace": {
    "width": 1920,
    "height": 1280
  },
  "calibration": {
    "pixelsPerFoot": 20,
    "printedScale": "3/8 inch = 1 foot",
    "checks": [
      {
        "view": "Registered food-prep clear south wall from A2.16",
        "sourcePixels": 490,
        "referenceFeet": 24.5,
        "pixelsPerFoot": 20
      },
      {
        "view": "Registered servery rear corridor height",
        "sourcePixels": 70,
        "referenceFeet": 3.5,
        "pixelsPerFoot": 20
      }
    ]
  },
  "rows": [
    {
      "id": "foodprep",
      "label": "Food-prep119 clear footprint",
      "quantity": 286.1925,
      "unit": "SF",
      "color": "#299bba",
      "basis": "3/8-inch source trace registered with A2.16. Same rooms as lobby plan, not extra project floor area. No finish/material assignment; built-ins included.",
      "sourceSheet": "A2.17",
      "parentSheet": "First floor / kitchen",
      "polygons": [
        [
          [
            125,
            228
          ],
          [
            376,
            228
          ],
          [
            376,
            75
          ],
          [
            615,
            75
          ],
          [
            615,
            387
          ],
          [
            125,
            387
          ]
        ]
      ]
    },
    {
      "id": "pbx",
      "label": "PBX115 contextual footprint",
      "quantity": 79.8025,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "3/8-inch source trace registered with A2.16. Same rooms as lobby plan, not extra project floor area. No finish/material assignment; built-ins included.",
      "sourceSheet": "A2.17",
      "parentSheet": "First floor / kitchen",
      "polygons": [
        [
          [
            126,
            74
          ],
          [
            359,
            74
          ],
          [
            359,
            211
          ],
          [
            126,
            211
          ]
        ]
      ]
    },
    {
      "id": "servery",
      "label": "Servery136 rear strip",
      "quantity": 65.175,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "3/8-inch source trace registered with A2.16. Same rooms as lobby plan, not extra project floor area. No finish/material assignment; built-ins included.",
      "sourceSheet": "A2.17",
      "parentSheet": "First floor / kitchen",
      "polygons": [
        [
          [
            636,
            74
          ],
          [
            1031,
            74
          ],
          [
            1031,
            140
          ],
          [
            636,
            140
          ]
        ]
      ]
    },
    {
      "id": "breakfast",
      "label": "Breakfast123 depicted service zone",
      "quantity": 188.6125,
      "unit": "SF",
      "color": "#398d79",
      "basis": "3/8-inch source trace registered with A2.16. Same rooms as lobby plan, not extra project floor area. No finish/material assignment; built-ins included.",
      "sourceSheet": "A2.17",
      "parentSheet": "First floor / kitchen",
      "polygons": [
        [
          [
            636,
            205
          ],
          [
            1031,
            205
          ],
          [
            1031,
            396
          ],
          [
            636,
            396
          ]
        ]
      ]
    },
    {
      "id": "prep-south",
      "label": "Food-prep south equipment line",
      "quantity": 24.25,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Source equipment/casework run only. Not appliance procurement dimensions; utilities, service clearances, worktop depth and fabrication to approved equipment/shop drawings.",
      "sourceSheet": "A2.17",
      "parentSheet": "First floor / kitchen",
      "line": [
        [
          128,
          376
        ],
        [
          613,
          376
        ]
      ]
    },
    {
      "id": "dishwall",
      "label": "West dishwashing equipment line",
      "quantity": 9.05,
      "unit": "LF",
      "color": "#b06bad",
      "basis": "Source equipment/casework run only. Not appliance procurement dimensions; utilities, service clearances, worktop depth and fabrication to approved equipment/shop drawings.",
      "sourceSheet": "A2.17",
      "parentSheet": "First floor / kitchen",
      "line": [
        [
          380,
          77
        ],
        [
          380,
          258
        ]
      ]
    },
    {
      "id": "servery-front",
      "label": "Breakfast servery front",
      "quantity": 19.6,
      "unit": "LF",
      "color": "#cf4f62",
      "basis": "Source equipment/casework run only. Not appliance procurement dimensions; utilities, service clearances, worktop depth and fabrication to approved equipment/shop drawings.",
      "sourceSheet": "A2.17",
      "parentSheet": "First floor / kitchen",
      "line": [
        [
          638,
          201
        ],
        [
          1030,
          201
        ]
      ]
    },
    {
      "id": "island-long",
      "label": "Breakfast island long face",
      "quantity": 7.9,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Source equipment/casework run only. Not appliance procurement dimensions; utilities, service clearances, worktop depth and fabrication to approved equipment/shop drawings.",
      "sourceSheet": "A2.17",
      "parentSheet": "First floor / kitchen",
      "line": [
        [
          752,
          372
        ],
        [
          910,
          372
        ]
      ]
    },
    {
      "id": "island-short",
      "label": "Breakfast island short face",
      "quantity": 2.55,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Source equipment/casework run only. Not appliance procurement dimensions; utilities, service clearances, worktop depth and fabrication to approved equipment/shop drawings.",
      "sourceSheet": "A2.17",
      "parentSheet": "First floor / kitchen",
      "line": [
        [
          910,
          321
        ],
        [
          910,
          372
        ]
      ]
    },
    {
      "id": "cold-display",
      "label": "Display freezer/refrigerator bank",
      "quantity": 6.8,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Source equipment/casework run only. Not appliance procurement dimensions; utilities, service clearances, worktop depth and fabrication to approved equipment/shop drawings.",
      "sourceSheet": "A2.17",
      "parentSheet": "First floor / kitchen",
      "line": [
        [
          1075,
          250
        ],
        [
          1075,
          386
        ]
      ]
    },
    {
      "id": "equipment-envelope-01",
      "label": "Equipment 01 drawn envelope",
      "quantity": 10.6575,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Reference plan footprint; selected schedule/model and manufacturer clearance govern final size. Not additional room area or new equipment count.",
      "sourceSheet": "A2.17",
      "parentSheet": "First floor / kitchen",
      "polygons": [
        [
          [
            128,
            333
          ],
          [
            215,
            333
          ],
          [
            215,
            382
          ],
          [
            128,
            382
          ]
        ]
      ]
    },
    {
      "id": "equipment-envelope-02-west",
      "label": "Equipment 02-west drawn envelope",
      "quantity": 10.9025,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Reference plan footprint; selected schedule/model and manufacturer clearance govern final size. Not additional room area or new equipment count.",
      "sourceSheet": "A2.17",
      "parentSheet": "First floor / kitchen",
      "polygons": [
        [
          [
            219,
            333
          ],
          [
            308,
            333
          ],
          [
            308,
            382
          ],
          [
            219,
            382
          ]
        ]
      ]
    },
    {
      "id": "equipment-envelope-02-east",
      "label": "Equipment 02-east drawn envelope",
      "quantity": 10.6575,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Reference plan footprint; selected schedule/model and manufacturer clearance govern final size. Not additional room area or new equipment count.",
      "sourceSheet": "A2.17",
      "parentSheet": "First floor / kitchen",
      "polygons": [
        [
          [
            526,
            333
          ],
          [
            613,
            333
          ],
          [
            613,
            382
          ],
          [
            526,
            382
          ]
        ]
      ]
    },
    {
      "id": "equipment-envelope-04",
      "label": "Equipment 04 drawn envelope",
      "quantity": 10.1475,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Reference plan footprint; selected schedule/model and manufacturer clearance govern final size. Not additional room area or new equipment count.",
      "sourceSheet": "A2.17",
      "parentSheet": "First floor / kitchen",
      "polygons": [
        [
          [
            482,
            166
          ],
          [
            523,
            166
          ],
          [
            523,
            265
          ],
          [
            482,
            265
          ]
        ]
      ]
    },
    {
      "id": "equipment-envelope-18",
      "label": "Equipment 18 drawn envelope",
      "quantity": 5.64,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Reference plan footprint; selected schedule/model and manufacturer clearance govern final size. Not additional room area or new equipment count.",
      "sourceSheet": "A2.17",
      "parentSheet": "First floor / kitchen",
      "polygons": [
        [
          [
            565,
            193
          ],
          [
            613,
            193
          ],
          [
            613,
            240
          ],
          [
            565,
            240
          ]
        ]
      ]
    },
    {
      "id": "equipment-envelope-35",
      "label": "Equipment 35 drawn envelope",
      "quantity": 5.64,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Reference plan footprint; selected schedule/model and manufacturer clearance govern final size. Not additional room area or new equipment count.",
      "sourceSheet": "A2.17",
      "parentSheet": "First floor / kitchen",
      "polygons": [
        [
          [
            1052,
            250
          ],
          [
            1100,
            250
          ],
          [
            1100,
            297
          ],
          [
            1052,
            297
          ]
        ]
      ]
    },
    {
      "id": "equipment-envelope-36",
      "label": "Equipment 36 drawn envelope",
      "quantity": 10.44,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Reference plan footprint; selected schedule/model and manufacturer clearance govern final size. Not additional room area or new equipment count.",
      "sourceSheet": "A2.17",
      "parentSheet": "First floor / kitchen",
      "polygons": [
        [
          [
            1052,
            299
          ],
          [
            1100,
            299
          ],
          [
            1100,
            386
          ],
          [
            1052,
            386
          ]
        ]
      ]
    }
  ]
}