{
  "sheet": "A2.14",
  "parent": "A2.14",
  "coordinateSpace": {
    "width": 1920,
    "height": 1280
  },
  "calibration": {
    "pixelsPerFoot": 20,
    "printedScale": "Small floor 1/4; elevations 3/8 inch = 1 foot; large composites dimension checked",
    "checks": [
      {
        "view": "Large furniture width compared to printed minimum (not controlling)",
        "sourcePixels": 324,
        "printedFeet": 16,
        "pixelsPerFoot": 20.25,
        "relativeDifferencePercent": 1.2499999999999956
      },
      {
        "view": "Large furniture length compared to printed dimension / minimum",
        "sourcePixels": 700,
        "printedFeet": 35,
        "pixelsPerFoot": 20.0,
        "relativeDifferencePercent": 0.0
      },
      {
        "view": "Elevation printed 6-foot-6-inch height",
        "sourcePixels": 130,
        "printedFeet": 6.5,
        "pixelsPerFoot": 20.0,
        "relativeDifferencePercent": 0.0
      },
      {
        "view": "Large furniture main zone 25-foot-4-3/4-inch",
        "sourcePixels": 508,
        "printedFeet": 25.395833333333332,
        "pixelsPerFoot": 20.003281378178837,
        "relativeDifferencePercent": 0.016406890894193893
      },
      {
        "view": "Small floor plan overall width",
        "sourcePixels": 222,
        "printedFeet": 16.666666666666668,
        "pixelsPerFoot": 13.319999999999999,
        "expectedPixelsPerFoot": 13.333333333333334,
        "relativeDifferencePercent": -0.10000000000001119
      },
      {
        "view": "Small floor plan overall length",
        "sourcePixels": 475,
        "printedFeet": 35.625,
        "pixelsPerFoot": 13.333333333333334,
        "expectedPixelsPerFoot": 13.333333333333334,
        "relativeDifferencePercent": 0.0
      }
    ],
    "basis": "Independent mixed-scale checks; large-view dimensions distinguish exact dimensions from minimums. Approximate source traces."
  },
  "rows": [
    {
      "id": "carpet",
      "label": "Main carpet field \u00b7 combined CPT-01/02",
      "quantity": 415.8625,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Combined field; component pattern portions below are subsets. Includes built-ins pending installation deductions; no waste.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "polygons": [
        [
          [
            892,
            248
          ],
          [
            1215,
            248
          ],
          [
            1215,
            763
          ],
          [
            892,
            763
          ]
        ]
      ]
    },
    {
      "id": "carpet-cpt02",
      "label": "Main carpet field \u00b7 CPT-02",
      "quantity": 193.06995885038538,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Actual jagged pattern boundary from PDF vector 2887, clipped to adopted field. Separate product code; do not add combined field. Product, cuts and built-in deductions to specification.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "polygons": [
        [
          [
            1214.6501555266202,
            763.0
          ],
          [
            1214.6501555266202,
            248.0
          ],
          [
            1036.7137767650463,
            248.0
          ],
          [
            1036.7137767650463,
            267.7511257595486
          ],
          [
            1056.7334888599537,
            267.7511257595486
          ],
          [
            1056.7334888599537,
            287.770837854456
          ],
          [
            1076.7531105324074,
            287.770837854456
          ],
          [
            1076.7531105324074,
            307.79052734375
          ],
          [
            1096.7728226273148,
            307.79052734375
          ],
          [
            1096.7728226273148,
            327.8102394386574
          ],
          [
            1056.7334888599537,
            327.8102394386574
          ],
          [
            1056.7334888599537,
            347.8299515335648
          ],
          [
            1076.7531105324074,
            347.8299515335648
          ],
          [
            1076.7531105324074,
            367.84964102285875
          ],
          [
            1096.7728226273148,
            367.84964102285875
          ],
          [
            1096.7728226273148,
            387.8693757233796
          ],
          [
            1056.7334888599537,
            387.8693757233796
          ],
          [
            1056.7334888599537,
            407.889087818287
          ],
          [
            1016.6940646701388,
            407.889087818287
          ],
          [
            1016.6940646701388,
            427.90875470196755
          ],
          [
            1096.7728226273148,
            427.90875470196755
          ],
          [
            1096.7728226273148,
            447.92846679687494
          ],
          [
            1056.7334888599537,
            447.92846679687494
          ],
          [
            1056.7334888599537,
            467.94813368055554
          ],
          [
            1016.6940646701388,
            467.94813368055554
          ],
          [
            1016.6940646701388,
            487.96784577546293
          ],
          [
            1096.7728226273148,
            487.96784577546293
          ],
          [
            1096.7728226273148,
            507.9875578703703
          ],
          [
            1116.7925347222222,
            507.9875578703703
          ],
          [
            1116.7925347222222,
            528.0072699652777
          ],
          [
            1076.7531105324074,
            528.0072699652777
          ],
          [
            1076.7531105324074,
            548.0269820601851
          ],
          [
            1096.7728226273148,
            548.0269820601851
          ],
          [
            1096.7728226273148,
            568.0466941550926
          ],
          [
            1056.7334888599537,
            568.0466941550926
          ],
          [
            1056.7334888599537,
            588.06640625
          ],
          [
            1016.6940646701388,
            588.06640625
          ],
          [
            1016.6940646701388,
            608.0861183449074
          ],
          [
            1036.7137767650463,
            608.0861183449074
          ],
          [
            1036.7137767650463,
            628.1058304398148
          ],
          [
            1056.7334888599537,
            628.1058304398148
          ],
          [
            1056.7334888599537,
            648.1254973234953
          ],
          [
            1016.6940646701388,
            648.1254973234953
          ],
          [
            1016.6940646701388,
            668.1452094184027
          ],
          [
            1036.7137767650463,
            668.1452094184027
          ],
          [
            1036.7137767650463,
            688.1649215133101
          ],
          [
            1056.7334888599537,
            688.1649215133101
          ],
          [
            1056.7334888599537,
            708.1846336082175
          ],
          [
            1076.7531105324074,
            708.1846336082175
          ],
          [
            1076.7531105324074,
            728.204345703125
          ],
          [
            1096.7728226273148,
            728.204345703125
          ],
          [
            1096.7728226273148,
            748.2240125868055
          ],
          [
            1116.7925347222222,
            748.2240125868055
          ],
          [
            1116.7925347222222,
            763.0
          ]
        ]
      ]
    },
    {
      "id": "carpet-cpt01",
      "label": "Main carpet field \u00b7 CPT-01",
      "quantity": 222.79254114961464,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Actual jagged pattern boundary from PDF vector 2887, clipped to adopted field. Separate product code; do not add combined field. Product, cuts and built-in deductions to specification.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "polygons": [
        [
          [
            892,
            248
          ],
          [
            1215,
            248
          ],
          [
            1215,
            763
          ],
          [
            892,
            763
          ]
        ],
        [
          [
            1214.6501555266202,
            763.0
          ],
          [
            1214.6501555266202,
            248.0
          ],
          [
            1036.7137767650463,
            248.0
          ],
          [
            1036.7137767650463,
            267.7511257595486
          ],
          [
            1056.7334888599537,
            267.7511257595486
          ],
          [
            1056.7334888599537,
            287.770837854456
          ],
          [
            1076.7531105324074,
            287.770837854456
          ],
          [
            1076.7531105324074,
            307.79052734375
          ],
          [
            1096.7728226273148,
            307.79052734375
          ],
          [
            1096.7728226273148,
            327.8102394386574
          ],
          [
            1056.7334888599537,
            327.8102394386574
          ],
          [
            1056.7334888599537,
            347.8299515335648
          ],
          [
            1076.7531105324074,
            347.8299515335648
          ],
          [
            1076.7531105324074,
            367.84964102285875
          ],
          [
            1096.7728226273148,
            367.84964102285875
          ],
          [
            1096.7728226273148,
            387.8693757233796
          ],
          [
            1056.7334888599537,
            387.8693757233796
          ],
          [
            1056.7334888599537,
            407.889087818287
          ],
          [
            1016.6940646701388,
            407.889087818287
          ],
          [
            1016.6940646701388,
            427.90875470196755
          ],
          [
            1096.7728226273148,
            427.90875470196755
          ],
          [
            1096.7728226273148,
            447.92846679687494
          ],
          [
            1056.7334888599537,
            447.92846679687494
          ],
          [
            1056.7334888599537,
            467.94813368055554
          ],
          [
            1016.6940646701388,
            467.94813368055554
          ],
          [
            1016.6940646701388,
            487.96784577546293
          ],
          [
            1096.7728226273148,
            487.96784577546293
          ],
          [
            1096.7728226273148,
            507.9875578703703
          ],
          [
            1116.7925347222222,
            507.9875578703703
          ],
          [
            1116.7925347222222,
            528.0072699652777
          ],
          [
            1076.7531105324074,
            528.0072699652777
          ],
          [
            1076.7531105324074,
            548.0269820601851
          ],
          [
            1096.7728226273148,
            548.0269820601851
          ],
          [
            1096.7728226273148,
            568.0466941550926
          ],
          [
            1056.7334888599537,
            568.0466941550926
          ],
          [
            1056.7334888599537,
            588.06640625
          ],
          [
            1016.6940646701388,
            588.06640625
          ],
          [
            1016.6940646701388,
            608.0861183449074
          ],
          [
            1036.7137767650463,
            608.0861183449074
          ],
          [
            1036.7137767650463,
            628.1058304398148
          ],
          [
            1056.7334888599537,
            628.1058304398148
          ],
          [
            1056.7334888599537,
            648.1254973234953
          ],
          [
            1016.6940646701388,
            648.1254973234953
          ],
          [
            1016.6940646701388,
            668.1452094184027
          ],
          [
            1036.7137767650463,
            668.1452094184027
          ],
          [
            1036.7137767650463,
            688.1649215133101
          ],
          [
            1056.7334888599537,
            688.1649215133101
          ],
          [
            1056.7334888599537,
            708.1846336082175
          ],
          [
            1076.7531105324074,
            708.1846336082175
          ],
          [
            1076.7531105324074,
            728.204345703125
          ],
          [
            1096.7728226273148,
            728.204345703125
          ],
          [
            1096.7728226273148,
            748.2240125868055
          ],
          [
            1116.7925347222222,
            748.2240125868055
          ],
          [
            1116.7925347222222,
            763.0
          ]
        ]
      ]
    },
    {
      "id": "entry-tile",
      "label": "T-01 entry / kitchen floor",
      "quantity": 63.72,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Trace of source exposed-zone envelope. Built-in footprints included pending installation deductions; internal partitions excluded. Full-tile starts/doorway thresholds require final layout.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "polygons": [
        [
          [
            892,
            63
          ],
          [
            1036,
            63
          ],
          [
            1036,
            240
          ],
          [
            892,
            240
          ]
        ]
      ]
    },
    {
      "id": "bath-tile",
      "label": "T-01 dry bathroom floor",
      "quantity": 48.4,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Trace of source exposed-zone envelope. Built-in footprints included pending installation deductions; internal partitions excluded. Full-tile starts/doorway thresholds require final layout.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "polygons": [
        [
          [
            1046,
            63
          ],
          [
            1156,
            63
          ],
          [
            1156,
            239
          ],
          [
            1046,
            239
          ]
        ]
      ]
    },
    {
      "id": "fixture-exclusion",
      "label": "Tub footprint \u00b7 no finishes",
      "quantity": 12.1275,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Source explicitly excludes finish under fixture. Non-additive excluded area; waterproofing and selected fixture requirements separate.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "polygons": [
        [
          [
            1158,
            108
          ],
          [
            1207,
            108
          ],
          [
            1207,
            207
          ],
          [
            1158,
            207
          ]
        ]
      ]
    },
    {
      "id": "tile-total",
      "label": "T-01 combined entry + dry bath",
      "quantity": 112.12,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Alternate combined total; do not add again to component tile rows.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "polygons": [
        [
          [
            892,
            63
          ],
          [
            1036,
            63
          ],
          [
            1036,
            240
          ],
          [
            892,
            240
          ]
        ],
        [
          [
            1046,
            63
          ],
          [
            1156,
            63
          ],
          [
            1156,
            239
          ],
          [
            1046,
            239
          ]
        ]
      ]
    },
    {
      "id": "suite-envelope",
      "label": "Large-plan clear suite envelope",
      "quantity": 565.25,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Reference envelope includes internal walls/boxed voids. Do not add to separately measured finish fields. No building multiplier.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "polygons": [
        [
          [
            1333,
            64
          ],
          [
            1656,
            64
          ],
          [
            1656,
            764
          ],
          [
            1333,
            764
          ]
        ]
      ]
    },
    {
      "id": "ceiling-1",
      "label": "Main room PT-07 ceiling",
      "quantity": 412.965,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Horizontal source ceiling field, 8 feet labeled. Overall RCP controls ground-floor height. No light deductions; vertical soffit faces separate.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "polygons": [
        [
          [
            483,
            250
          ],
          [
            805,
            250
          ],
          [
            805,
            763
          ],
          [
            483,
            763
          ]
        ]
      ]
    },
    {
      "id": "ceiling-2",
      "label": "Entry / kitchen PT-07 ceiling",
      "quantity": 64.44,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Horizontal source ceiling field, 7 feet 3 inches labeled. Overall RCP controls ground-floor height. No light deductions; vertical soffit faces separate.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "polygons": [
        [
          [
            483,
            63
          ],
          [
            627,
            63
          ],
          [
            627,
            242
          ],
          [
            483,
            242
          ]
        ]
      ]
    },
    {
      "id": "ceiling-3",
      "label": "Bathroom PT-07 ceiling",
      "quantity": 61.56,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Horizontal source ceiling field, 7 feet 3 inches labeled. Overall RCP controls ground-floor height. No light deductions; vertical soffit faces separate.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "polygons": [
        [
          [
            639,
            63
          ],
          [
            747,
            63
          ],
          [
            747,
            107
          ],
          [
            801,
            107
          ],
          [
            801,
            209
          ],
          [
            747,
            209
          ],
          [
            747,
            240
          ],
          [
            639,
            240
          ]
        ]
      ]
    },
    {
      "id": "carpet-boundary",
      "label": "Carpet gross finish boundary",
      "quantity": 83.8,
      "unit": "LF",
      "color": "#398d79",
      "basis": "Geometric field perimeter, not net installed base. Deduct doors, casegoods and interruptions. CPT-01.1 / T-01.1 base remain separate products.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "line": [
        [
          892,
          248
        ],
        [
          1215,
          248
        ],
        [
          1215,
          763
        ],
        [
          892,
          763
        ],
        [
          892,
          248
        ]
      ]
    },
    {
      "id": "entry-boundary",
      "label": "Entry gross finish boundary",
      "quantity": 32.1,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Geometric field perimeter, not net installed base. Deduct doors, casegoods and interruptions. CPT-01.1 / T-01.1 base remain separate products.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "line": [
        [
          892,
          63
        ],
        [
          1036,
          63
        ],
        [
          1036,
          240
        ],
        [
          892,
          240
        ],
        [
          892,
          63
        ]
      ]
    },
    {
      "id": "bath-boundary",
      "label": "Bath gross finish boundary",
      "quantity": 28.6,
      "unit": "LF",
      "color": "#b06bad",
      "basis": "Geometric field perimeter, not net installed base. Deduct doors, casegoods and interruptions. CPT-01.1 / T-01.1 base remain separate products.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "line": [
        [
          1046,
          63
        ],
        [
          1156,
          63
        ],
        [
          1156,
          239
        ],
        [
          1046,
          239
        ],
        [
          1046,
          63
        ]
      ]
    },
    {
      "id": "small-overall",
      "label": "Small floor plan \u00b7 dimensioned gross envelope",
      "quantity": 593.75,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Printed overall width \u00d7 length, including exterior/demising wall thickness. Independent reference only; not added to clear suite or finishes.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "polygons": [
        [
          [
            129,
            188
          ],
          [
            358,
            188
          ],
          [
            358,
            666
          ],
          [
            129,
            666
          ]
        ]
      ]
    },
    {
      "id": "wall-work",
      "label": "SF-02 working-wall gross face",
      "quantity": 270.0625,
      "unit": "SF",
      "color": "#58a7ad",
      "basis": "Gross displayed face before doors, glazing, base and casegoods. Mixed SF/WC/PT boundaries require selected finish manual. No automatic net procurement quantity.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "polygons": [
        [
          [
            124,
            1017
          ],
          [
            559,
            1017
          ],
          [
            559,
            1032
          ],
          [
            824,
            1032
          ],
          [
            824,
            1177
          ],
          [
            124,
            1177
          ]
        ]
      ]
    },
    {
      "id": "wall-opposite",
      "label": "WC-01 / SF-02 opposite gross face",
      "quantity": 281.75,
      "unit": "SF",
      "color": "#299bba",
      "basis": "Gross displayed face before doors, glazing, base and casegoods. Mixed SF/WC/PT boundaries require selected finish manual. No automatic net procurement quantity.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "polygons": [
        [
          [
            124,
            805
          ],
          [
            824,
            805
          ],
          [
            824,
            966
          ],
          [
            124,
            966
          ]
        ]
      ]
    },
    {
      "id": "wall-entry",
      "label": "SF-02 entry-wall gross face",
      "quantity": 128.0,
      "unit": "SF",
      "color": "#d66a35",
      "basis": "Gross displayed face before doors, glazing, base and casegoods. Mixed SF/WC/PT boundaries require selected finish manual. No automatic net procurement quantity.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "polygons": [
        [
          [
            864,
            1017
          ],
          [
            1184,
            1017
          ],
          [
            1184,
            1177
          ],
          [
            864,
            1177
          ]
        ]
      ]
    },
    {
      "id": "wall-window",
      "label": "SF-01 window-wall gross face",
      "quantity": 128.8,
      "unit": "SF",
      "color": "#876bd5",
      "basis": "Gross displayed face before doors, glazing, base and casegoods. Mixed SF/WC/PT boundaries require selected finish manual. No automatic net procurement quantity.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "polygons": [
        [
          [
            864,
            805
          ],
          [
            1184,
            805
          ],
          [
            1184,
            966
          ],
          [
            864,
            966
          ]
        ]
      ]
    },
    {
      "id": "deduction-winopen",
      "label": "Window opening face",
      "quantity": 22.8,
      "unit": "SF",
      "color": "#398d79",
      "basis": "Deduction reference for matching gross wall only; opening counted once in door/window schedule. Do not treat as an additional finish area.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "polygons": [
        [
          [
            1004,
            859
          ],
          [
            1124,
            859
          ],
          [
            1124,
            935
          ],
          [
            1004,
            935
          ]
        ]
      ]
    },
    {
      "id": "deduction-entryopen",
      "label": "Entry opening face",
      "quantity": 22.44,
      "unit": "SF",
      "color": "#ba9138",
      "basis": "Deduction reference for matching gross wall only; opening counted once in door/window schedule. Do not treat as an additional finish area.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "polygons": [
        [
          [
            914,
            1041
          ],
          [
            980,
            1041
          ],
          [
            980,
            1177
          ],
          [
            914,
            1177
          ]
        ]
      ]
    },
    {
      "id": "deduction-bathopen",
      "label": "Bathroom opening face",
      "quantity": 21.6,
      "unit": "SF",
      "color": "#b06bad",
      "basis": "Deduction reference for matching gross wall only; opening counted once in door/window schedule. Do not treat as an additional finish area.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "polygons": [
        [
          [
            163,
            831
          ],
          [
            227,
            831
          ],
          [
            227,
            966
          ],
          [
            163,
            966
          ]
        ]
      ]
    },
    {
      "id": "deduction-connecting",
      "label": "Connecting opening face",
      "quantity": 21.6125,
      "unit": "SF",
      "color": "#cf4f62",
      "basis": "Deduction reference for matching gross wall only; opening counted once in door/window schedule. Do not treat as an additional finish area.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "polygons": [
        [
          [
            571,
            1044
          ],
          [
            636,
            1044
          ],
          [
            636,
            1177
          ],
          [
            571,
            1177
          ]
        ]
      ]
    },
    {
      "id": "sill",
      "label": "ST-01 window sill",
      "quantity": 6.0,
      "unit": "LF",
      "color": "#58a7ad",
      "basis": "Drawn assembly run. Kitchen run is a portion of the full working-wall system. Shop modules, interruptions, end returns, drapery fullness and depth remain unresolved.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "line": [
        [
          1004,
          935
        ],
        [
          1124,
          935
        ]
      ]
    },
    {
      "id": "working",
      "label": "Kitchen working-wall source run",
      "quantity": 9.1,
      "unit": "LF",
      "color": "#299bba",
      "basis": "Drawn assembly run. Kitchen run is a portion of the full working-wall system. Shop modules, interruptions, end returns, drapery fullness and depth remain unresolved.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "line": [
        [
          1333,
          64
        ],
        [
          1333,
          246
        ]
      ]
    },
    {
      "id": "curtain",
      "label": "Divider drapery opening",
      "quantity": 4.65,
      "unit": "LF",
      "color": "#d66a35",
      "basis": "Drawn assembly run. Kitchen run is a portion of the full working-wall system. Shop modules, interruptions, end returns, drapery fullness and depth remain unresolved.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "line": [
        [
          1562,
          420
        ],
        [
          1655,
          420
        ]
      ]
    },
    {
      "id": "closet",
      "label": "Closet drapery opening",
      "quantity": 3.6,
      "unit": "LF",
      "color": "#876bd5",
      "basis": "Drawn assembly run. Kitchen run is a portion of the full working-wall system. Shop modules, interruptions, end returns, drapery fullness and depth remain unresolved.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "line": [
        [
          1374,
          686
        ],
        [
          1374,
          758
        ]
      ]
    },
    {
      "id": "selected-partitions",
      "label": "Selected bathroom partition centerlines",
      "quantity": 14.45,
      "unit": "LF",
      "color": "#398d79",
      "basis": "Unique interior runs excluding door gap; not all demising walls. Wall type, height, reinforcement/backing and two finish faces remain separate.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "lines": [
        [
          [
            1484,
            64
          ],
          [
            1484,
            94
          ]
        ],
        [
          [
            1484,
            160
          ],
          [
            1484,
            248
          ],
          [
            1655,
            248
          ]
        ]
      ]
    },
    {
      "id": "suite-gross-boundary",
      "label": "Suite gross interior boundary",
      "quantity": 102.3,
      "unit": "LF",
      "color": "#ba9138",
      "basis": "Single suite boundary trace including openings. Not automatically CMU/stud LF: assign wall types and shared-room ownership from floor plan before project aggregation; deduct openings separately.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "line": [
        [
          1333,
          64
        ],
        [
          1656,
          64
        ],
        [
          1656,
          764
        ],
        [
          1333,
          764
        ],
        [
          1333,
          64
        ]
      ]
    },
    {
      "id": "working-system",
      "label": "Working-wall overall run excluding connecting gap",
      "quantity": 31.7,
      "unit": "LF",
      "color": "#b06bad",
      "basis": "Overall source wall run with connecting opening gap excluded; includes closet/cabinet modules and clear interruptions. Kitchen-only run above is a subset, not additive. Vendor module widths govern purchase.",
      "sourceSheet": "A2.14",
      "parentSheet": "A2.14",
      "lines": [
        [
          [
            1333,
            64
          ],
          [
            1333,
            248
          ]
        ],
        [
          [
            1333,
            314
          ],
          [
            1333,
            764
          ]
        ]
      ]
    }
  ]
}
