  "sheet": "A2.1",
  "coordinateSpace": {
    "width": 1920,
    "height": 1280
  },
  "calibration": {
    "printedPlanScale": "1/8 inch = 1 foot",
    "pixelsPerFoot": 6.673244444444444,
    "checks": [
      {
        "printedFeet": 45,
        "pixelDistance": 300.296
      },
      {
        "printedFeet": 12.666666666666666,
        "pixelDistance": 84.528
      }
    ],
    "method": "Pool inside dimension and independent structural-grid spacing from source PDF vector coordinates."
  },
  "rows": [
    {
      "id": "slab",
      "label": "Main building slab footprint",
      "quantity": 12051.057514666003,
      "unit": "SF",
      "color": "#299bba",
      "polygons": [
        [
          [
            340,
            520
          ],
          [
            594,
            520
          ],
          [
            594,
            556
          ],
          [
            765,
            556
          ],
          [
            765,
            520
          ],
          [
            1383,
            520
          ],
          [
            1383,
            541
          ],
          [
            1441,
            541
          ],
          [
            1441,
            566
          ],
          [
            1552,
            566
          ],
          [
            1552,
            995
          ],
          [
            1004,
            995
          ],
          [
            1004,
            955
          ],
          [
            340,
            955
          ]
        ]
      ],
      "basis": "Traced gross first-floor building outline, including wall footprint and north/east recesses. Pool, detached pool rooms and exterior patios excluded. Confirm slab thickness, reinforcement and foundations with structural before CY."
    },
    {
      "id": "envelope",
      "label": "Exterior perimeter · gross",
      "quantity": 516.3904947118842,
      "unit": "LF",
      "color": "#a86949",
      "polygons": [
        [
          [
            340,
            520
          ],
          [
            594,
            520
          ],
          [
            594,
            556
          ],
          [
            765,
            556
          ],
          [
            765,
            520
          ],
          [
            1383,
            520
          ],
          [
            1383,
            541
          ],
          [
            1441,
            541
          ],
          [
            1441,
            566
          ],
          [
            1552,
            566
          ],
          [
            1552,
            995
          ],
          [
            1004,
            995
          ],
          [
            1004,
            955
          ],
          [
            340,
            955
          ]
        ]
      ],
      "basis": "Gross traced exterior perimeter before windows/doors. W5/W6 or other exterior assembly assignment requires wall sections and tags."
    },
    {
      "id": "corridor-walls",
      "label": "Guest corridor wall runs",
      "quantity": 146.40554652742628,
      "unit": "LF",
      "color": "#e8aa42",
      "lines": [
        [
          [
            340,
            721
          ],
          [
            765,
            721
          ]
        ],
        [
          [
            465,
            754
          ],
          [
            1017,
            754
          ]
        ]
      ],
      "basis": "Gross traced guestroom-facing corridor wall runs, before door deductions. W1/W1A/W1B are assembly references only until plan tags are linked."
    },
    {
      "id": "party-walls",
      "label": "Shared guestroom wall runs",
      "quantity": 253.25012654181214,
      "unit": "LF",
      "color": "#876bd5",
      "lines": [
        [
          [
            424,
            525
          ],
          [
            424,
            716
          ]
        ],
        [
          [
            509.5,
            525
          ],
          [
            509.5,
            716
          ]
        ],
        [
          [
            594,
            560
          ],
          [
            594,
            716
          ]
        ],
        [
          [
            509.5,
            758
          ],
          [
            509.5,
            950
          ]
        ],
        [
          [
            594,
            758
          ],
          [
            594,
            950
          ]
        ],
        [
          [
            679,
            758
          ],
          [
            679,
            950
          ]
        ],
        [
          [
            764.5,
            758
          ],
          [
            764.5,
            950
          ]
        ],
        [
          [
            849,
            758
          ],
          [
            849,
            950
          ]
        ],
        [
          [
            933,
            758
          ],
          [
            933,
            950
          ]
        ]
      ],
      "basis": "Nine shared-room boundary runs counted once. Gross length before connecting openings. Resolve W3/W4 or other specified party-wall type from tags/sections."
    },
    {
      "id": "room-101",
      "label": "101 · King studio · floor/ceiling",
      "quantity": 325.9664422220618,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            344,
            525
          ],
          [
            420,
            525
          ],
          [
            420,
            716
          ],
          [
            344,
            716
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room101/floor"
    },
    {
      "id": "walls-101",
      "label": "101 · gross room wall faces",
      "quantity": 80.0210459013773,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            344,
            525
          ],
          [
            420,
            525
          ],
          [
            420,
            716
          ],
          [
            344,
            716
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-103",
      "label": "103 · King studio · floor/ceiling",
      "quantity": 334.54450649106343,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            428,
            525
          ],
          [
            506,
            525
          ],
          [
            506,
            716
          ],
          [
            428,
            716
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room103/floor"
    },
    {
      "id": "walls-103",
      "label": "103 · gross room wall faces",
      "quantity": 80.62045448490822,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            428,
            525
          ],
          [
            506,
            525
          ],
          [
            506,
            716
          ],
          [
            428,
            716
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-105",
      "label": "105 · Connecting king studio · floor/ceiling",
      "quantity": 330.2554743565626,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            513,
            525
          ],
          [
            590,
            525
          ],
          [
            590,
            716
          ],
          [
            513,
            716
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room105/floor"
    },
    {
      "id": "walls-105",
      "label": "105 · gross room wall faces",
      "quantity": 80.32075019314277,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            513,
            525
          ],
          [
            590,
            525
          ],
          [
            590,
            716
          ],
          [
            513,
            716
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-107",
      "label": "107 · Accessible king one-bedroom · floor/ceiling",
      "quantity": 567.4995816916469,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            598,
            560
          ],
          [
            760,
            560
          ],
          [
            760,
            716
          ],
          [
            598,
            716
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room107/floor"
    },
    {
      "id": "walls-107",
      "label": "107 · gross room wall faces",
      "quantity": 95.30596478141567,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            598,
            560
          ],
          [
            760,
            560
          ],
          [
            760,
            716
          ],
          [
            598,
            716
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-102",
      "label": "102 · King one-bedroom · floor/ceiling",
      "quantity": 525.6871322966704,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            465,
            758
          ],
          [
            505,
            758
          ],
          [
            505,
            950
          ],
          [
            344,
            950
          ],
          [
            344,
            820
          ],
          [
            465,
            820
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room102/floor"
    },
    {
      "id": "walls-102",
      "label": "102 · gross room wall faces",
      "quantity": 105.7956149932067,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            465,
            758
          ],
          [
            505,
            758
          ],
          [
            505,
            950
          ],
          [
            344,
            950
          ],
          [
            344,
            820
          ],
          [
            465,
            820
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-104",
      "label": "104 · King studio · floor/ceiling",
      "quantity": 327.6730728096119,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            514,
            758
          ],
          [
            590,
            758
          ],
          [
            590,
            950
          ],
          [
            514,
            950
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room104/floor"
    },
    {
      "id": "walls-104",
      "label": "104 · gross room wall faces",
      "quantity": 80.32075019314277,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            514,
            758
          ],
          [
            590,
            758
          ],
          [
            590,
            950
          ],
          [
            514,
            950
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-106",
      "label": "106 · King studio · floor/ceiling",
      "quantity": 331.98456060973837,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            598,
            758
          ],
          [
            675,
            758
          ],
          [
            675,
            950
          ],
          [
            598,
            950
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room106/floor"
    },
    {
      "id": "walls-106",
      "label": "106 · gross room wall faces",
      "quantity": 80.62045448490822,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            598,
            758
          ],
          [
            675,
            758
          ],
          [
            675,
            950
          ],
          [
            598,
            950
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-108",
      "label": "108 · King studio · floor/ceiling",
      "quantity": 331.98456060973837,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            683,
            758
          ],
          [
            760,
            758
          ],
          [
            760,
            950
          ],
          [
            683,
            950
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room108/floor"
    },
    {
      "id": "walls-108",
      "label": "108 · gross room wall faces",
      "quantity": 80.62045448490822,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            683,
            758
          ],
          [
            760,
            758
          ],
          [
            760,
            950
          ],
          [
            683,
            950
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-110",
      "label": "110 · King studio · floor/ceiling",
      "quantity": 327.6730728096119,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            769,
            758
          ],
          [
            845,
            758
          ],
          [
            845,
            950
          ],
          [
            769,
            950
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room110/floor"
    },
    {
      "id": "walls-110",
      "label": "110 · gross room wall faces",
      "quantity": 80.32075019314277,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            769,
            758
          ],
          [
            845,
            758
          ],
          [
            845,
            950
          ],
          [
            769,
            950
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-112",
      "label": "112 · Connecting king studio · floor/ceiling",
      "quantity": 327.6730728096119,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            853,
            758
          ],
          [
            929,
            758
          ],
          [
            929,
            950
          ],
          [
            853,
            950
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room112/floor"
    },
    {
      "id": "walls-112",
      "label": "112 · gross room wall faces",
      "quantity": 80.32075019314277,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            853,
            758
          ],
          [
            929,
            758
          ],
          [
            929,
            950
          ],
          [
            853,
            950
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-114",
      "label": "114 · Connecting king studio · floor/ceiling",
      "quantity": 327.6730728096119,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            937,
            758
          ],
          [
            1013,
            758
          ],
          [
            1013,
            950
          ],
          [
            937,
            950
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room114/floor"
    },
    {
      "id": "walls-114",
      "label": "114 · gross room wall faces",
      "quantity": 80.32075019314277,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            937,
            758
          ],
          [
            1013,
            758
          ],
          [
            1013,
            950
          ],
          [
            937,
            950
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-109",
      "label": "109 · Mechanical · floor/ceiling",
      "quantity": 177.80396042396566,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            770,
            525
          ],
          [
            844,
            525
          ],
          [
            844,
            632
          ],
          [
            770,
            632
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room109/floor"
    },
    {
      "id": "walls-109",
      "label": "109 · gross room wall faces",
      "quantity": 54.246476809547914,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            770,
            525
          ],
          [
            844,
            525
          ],
          [
            844,
            632
          ],
          [
            770,
            632
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-111",
      "label": "111 · Engineer · floor/ceiling",
      "quantity": 91.39455909643094,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            770,
            638
          ],
          [
            844,
            638
          ],
          [
            844,
            693
          ],
          [
            770,
            693
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room111/floor"
    },
    {
      "id": "walls-111",
      "label": "111 · gross room wall faces",
      "quantity": 38.661853637744095,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            770,
            638
          ],
          [
            844,
            638
          ],
          [
            844,
            693
          ],
          [
            770,
            693
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-113",
      "label": "113 · Electrical · floor/ceiling",
      "quantity": 143.51415901358482,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            852,
            525
          ],
          [
            929,
            525
          ],
          [
            929,
            608
          ],
          [
            852,
            608
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room113/floor"
    },
    {
      "id": "walls-113",
      "label": "113 · gross room wall faces",
      "quantity": 47.95268668247329,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            852,
            525
          ],
          [
            929,
            525
          ],
          [
            929,
            608
          ],
          [
            852,
            608
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-115",
      "label": "115 · PBX · floor/ceiling",
      "quantity": 77.80888139290742,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            852,
            615
          ],
          [
            929,
            615
          ],
          [
            929,
            660
          ],
          [
            852,
            660
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room115/floor"
    },
    {
      "id": "walls-115",
      "label": "115 · gross room wall faces",
      "quantity": 36.56392359538589,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            852,
            615
          ],
          [
            929,
            615
          ],
          [
            929,
            660
          ],
          [
            852,
            660
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-117",
      "label": "117 · Employee breakroom · floor/ceiling",
      "quantity": 136.26097901649703,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            938,
            525
          ],
          [
            1012,
            525
          ],
          [
            1012,
            607
          ],
          [
            938,
            607
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room117/floor"
    },
    {
      "id": "walls-117",
      "label": "117 · gross room wall faces",
      "quantity": 46.75386951541146,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            938,
            525
          ],
          [
            1012,
            525
          ],
          [
            1012,
            607
          ],
          [
            938,
            607
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-119",
      "label": "119 · Food prep · floor/ceiling",
      "quantity": 270.81532744544404,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            852,
            665
          ],
          [
            934,
            665
          ],
          [
            934,
            615
          ],
          [
            1012,
            615
          ],
          [
            1012,
            716
          ],
          [
            852,
            716
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room119/floor"
    },
    {
      "id": "walls-119",
      "label": "119 · gross room wall faces",
      "quantity": 78.22282015078456,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            852,
            665
          ],
          [
            934,
            665
          ],
          [
            934,
            615
          ],
          [
            1012,
            615
          ],
          [
            1012,
            716
          ],
          [
            852,
            716
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-121",
      "label": "121 · Proposed sprinkler room · floor/ceiling",
      "quantity": 92.69698770271914,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            1021,
            525
          ],
          [
            1117,
            525
          ],
          [
            1117,
            568
          ],
          [
            1021,
            568
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room121/floor"
    },
    {
      "id": "walls-121",
      "label": "121 · gross room wall faces",
      "quantity": 41.65889655539868,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            1021,
            525
          ],
          [
            1117,
            525
          ],
          [
            1117,
            568
          ],
          [
            1021,
            568
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-125",
      "label": "125 · Dryer room · floor/ceiling",
      "quantity": 55.80232907976189,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            1122,
            525
          ],
          [
            1193,
            525
          ],
          [
            1193,
            560
          ],
          [
            1122,
            560
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room125/floor"
    },
    {
      "id": "walls-125",
      "label": "125 · gross room wall faces",
      "quantity": 31.768654927138556,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            1122,
            525
          ],
          [
            1193,
            525
          ],
          [
            1193,
            560
          ],
          [
            1122,
            560
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-127",
      "label": "127 · Laundry · floor/ceiling",
      "quantity": 321.36303076880176,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            1021,
            572
          ],
          [
            1117,
            572
          ],
          [
            1117,
            570
          ],
          [
            1198,
            570
          ],
          [
            1198,
            525
          ],
          [
            1295,
            525
          ],
          [
            1295,
            607
          ],
          [
            1021,
            607
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room127/floor"
    },
    {
      "id": "walls-127",
      "label": "127 · gross room wall faces",
      "quantity": 106.69472786850308,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            1021,
            572
          ],
          [
            1117,
            572
          ],
          [
            1117,
            570
          ],
          [
            1198,
            570
          ],
          [
            1198,
            525
          ],
          [
            1295,
            525
          ],
          [
            1295,
            607
          ],
          [
            1021,
            607
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-131",
      "label": "131 · Laundry discharge · floor/ceiling",
      "quantity": 108.01175165941838,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            1303,
            525
          ],
          [
            1377,
            525
          ],
          [
            1377,
            590
          ],
          [
            1303,
            590
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room131/floor"
    },
    {
      "id": "walls-131",
      "label": "131 · gross room wall faces",
      "quantity": 41.65889655539868,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            1303,
            525
          ],
          [
            1377,
            525
          ],
          [
            1377,
            590
          ],
          [
            1303,
            590
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-133",
      "label": "133 · Manager office · floor/ceiling",
      "quantity": 69.79220876454727,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            1303,
            615
          ],
          [
            1377,
            615
          ],
          [
            1377,
            657
          ],
          [
            1303,
            657
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room133/floor"
    },
    {
      "id": "walls-133",
      "label": "133 · gross room wall faces",
      "quantity": 34.76569784479314,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            1303,
            615
          ],
          [
            1377,
            615
          ],
          [
            1377,
            657
          ],
          [
            1303,
            657
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-136",
      "label": "136 · Servery zone · floor/ceiling",
      "quantity": 85.51117470250836,
      "unit": "SF",
      "color": "#8a92a0",
      "polygons": [
        [
          [
            1021,
            615
          ],
          [
            1157,
            615
          ],
          [
            1157,
            643
          ],
          [
            1021,
            643
          ]
        ]
      ],
      "basis": "Functional open-zone boundary traced around the named area; confirm finish transitions. Do not sum open zones into a building total. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room136/floor"
    },
    {
      "id": "walls-136",
      "label": "136 · gross room wall faces",
      "quantity": 49.151503849535125,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            1021,
            615
          ],
          [
            1157,
            615
          ],
          [
            1157,
            643
          ],
          [
            1021,
            643
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-123",
      "label": "123 · Breakfast/servery zone · floor/ceiling",
      "quantity": 194.0843180025682,
      "unit": "SF",
      "color": "#8a92a0",
      "polygons": [
        [
          [
            1021,
            649
          ],
          [
            1150,
            649
          ],
          [
            1150,
            716
          ],
          [
            1021,
            716
          ]
        ]
      ],
      "basis": "Functional open-zone boundary traced around the named area; confirm finish transitions. Do not sum open zones into a building total. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room123/floor"
    },
    {
      "id": "walls-123",
      "label": "123 · gross room wall faces",
      "quantity": 58.74204118602979,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            1021,
            649
          ],
          [
            1150,
            649
          ],
          [
            1150,
            716
          ],
          [
            1021,
            716
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-137",
      "label": "137 · Work-station zone · floor/ceiling",
      "quantity": 131.32073257885213,
      "unit": "SF",
      "color": "#8a92a0",
      "polygons": [
        [
          [
            1159,
            615
          ],
          [
            1295,
            615
          ],
          [
            1295,
            658
          ],
          [
            1159,
            658
          ]
        ]
      ],
      "basis": "Functional open-zone boundary traced around the named area; confirm finish transitions. Do not sum open zones into a building total. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room137/floor"
    },
    {
      "id": "walls-137",
      "label": "137 · gross room wall faces",
      "quantity": 53.647068226017,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            1159,
            615
          ],
          [
            1295,
            615
          ],
          [
            1295,
            658
          ],
          [
            1159,
            658
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-129",
      "label": "129 · Market zone · floor/ceiling",
      "quantity": 133.2968311539101,
      "unit": "SF",
      "color": "#8a92a0",
      "polygons": [
        [
          [
            1159,
            664
          ],
          [
            1271,
            664
          ],
          [
            1271,
            717
          ],
          [
            1159,
            717
          ]
        ]
      ],
      "basis": "Functional open-zone boundary traced around the named area; confirm finish transitions. Do not sum open zones into a building total. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room129/floor"
    },
    {
      "id": "walls-129",
      "label": "129 · gross room wall faces",
      "quantity": 49.45120814130058,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            1159,
            664
          ],
          [
            1271,
            664
          ],
          [
            1271,
            717
          ],
          [
            1159,
            717
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-116",
      "label": "116 · Women restroom · floor/ceiling",
      "quantity": 48.50423775142281,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            1051,
            783
          ],
          [
            1099,
            783
          ],
          [
            1099,
            828
          ],
          [
            1051,
            828
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room116/floor"
    },
    {
      "id": "walls-116",
      "label": "116 · gross room wall faces",
      "quantity": 27.872499134187603,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            1051,
            783
          ],
          [
            1099,
            783
          ],
          [
            1099,
            828
          ],
          [
            1051,
            828
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-118",
      "label": "118 · Men restroom · floor/ceiling",
      "quantity": 46.21375985760562,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            1051,
            835
          ],
          [
            1100,
            835
          ],
          [
            1100,
            877
          ],
          [
            1051,
            877
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room118/floor"
    },
    {
      "id": "walls-118",
      "label": "118 · gross room wall faces",
      "quantity": 27.273090550656686,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            1051,
            835
          ],
          [
            1100,
            835
          ],
          [
            1100,
            877
          ],
          [
            1051,
            877
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-120",
      "label": "120 · Storage · floor/ceiling",
      "quantity": 46.34849385135957,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            1051,
            883
          ],
          [
            1099,
            883
          ],
          [
            1099,
            926
          ],
          [
            1051,
            926
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room120/floor"
    },
    {
      "id": "walls-120",
      "label": "120 · gross room wall faces",
      "quantity": 27.273090550656686,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            1051,
            883
          ],
          [
            1099,
            883
          ],
          [
            1099,
            926
          ],
          [
            1051,
            926
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-122",
      "label": "122 · Sales · floor/ceiling",
      "quantity": 64.91932932377932,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            1051,
            933
          ],
          [
            1100,
            933
          ],
          [
            1100,
            992
          ],
          [
            1051,
            992
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room122/floor"
    },
    {
      "id": "walls-122",
      "label": "122 · gross room wall faces",
      "quantity": 32.36806351066947,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            1051,
            933
          ],
          [
            1100,
            933
          ],
          [
            1100,
            992
          ],
          [
            1051,
            992
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-128",
      "label": "128 · Mechanical closet · floor/ceiling",
      "quantity": 24.70123218822458,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            1268,
            940
          ],
          [
            1288,
            940
          ],
          [
            1288,
            995
          ],
          [
            1268,
            995
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room128/floor"
    },
    {
      "id": "walls-128",
      "label": "128 · gross room wall faces",
      "quantity": 22.477821882409355,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            1268,
            940
          ],
          [
            1288,
            940
          ],
          [
            1288,
            995
          ],
          [
            1268,
            995
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-126",
      "label": "126 · Vestibule · floor/ceiling",
      "quantity": 69.16345012702882,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            1294,
            938
          ],
          [
            1350,
            938
          ],
          [
            1350,
            993
          ],
          [
            1294,
            993
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room126/floor"
    },
    {
      "id": "walls-126",
      "label": "126 · gross room wall faces",
      "quantity": 33.26717638596585,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            1294,
            938
          ],
          [
            1350,
            938
          ],
          [
            1350,
            993
          ],
          [
            1294,
            993
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-124",
      "label": "124 · Lobby/common zone · floor/ceiling",
      "quantity": 1400.7395103973388,
      "unit": "SF",
      "color": "#8a92a0",
      "polygons": [
        [
          [
            1106,
            723
          ],
          [
            1436,
            723
          ],
          [
            1436,
            753
          ],
          [
            1350,
            753
          ],
          [
            1350,
            995
          ],
          [
            1294,
            995
          ],
          [
            1294,
            934
          ],
          [
            1264,
            934
          ],
          [
            1264,
            995
          ],
          [
            1126,
            995
          ],
          [
            1126,
            758
          ],
          [
            1106,
            758
          ]
        ]
      ],
      "basis": "Functional open-zone boundary traced around the named area; confirm finish transitions. Do not sum open zones into a building total. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room124/floor"
    },
    {
      "id": "walls-124",
      "label": "124 · gross room wall faces",
      "quantity": 198.7039454404987,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            1106,
            723
          ],
          [
            1436,
            723
          ],
          [
            1436,
            753
          ],
          [
            1350,
            753
          ],
          [
            1350,
            995
          ],
          [
            1294,
            995
          ],
          [
            1294,
            934
          ],
          [
            1264,
            934
          ],
          [
            1264,
            995
          ],
          [
            1126,
            995
          ],
          [
            1126,
            758
          ],
          [
            1106,
            758
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-135",
      "label": "135 · TV lounge · base · floor/ceiling",
      "quantity": 126.15592948495062,
      "unit": "SF",
      "color": "#58a7ad",
      "polygons": [
        [
          [
            1442,
            697
          ],
          [
            1548,
            697
          ],
          [
            1548,
            750
          ],
          [
            1442,
            750
          ]
        ]
      ],
      "basis": "Base-layout boundary beneath the blue proposed revision. Reconcile the selected design before ordering. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room135/floor"
    },
    {
      "id": "walls-135",
      "label": "135 · gross room wall faces",
      "quantity": 47.652982390707834,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            1442,
            697
          ],
          [
            1548,
            697
          ],
          [
            1548,
            750
          ],
          [
            1442,
            750
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-132",
      "label": "132 · Guest laundry · base · floor/ceiling",
      "quantity": 159.52504860467945,
      "unit": "SF",
      "color": "#58a7ad",
      "polygons": [
        [
          [
            1443,
            758
          ],
          [
            1517,
            758
          ],
          [
            1517,
            854
          ],
          [
            1443,
            854
          ]
        ]
      ],
      "basis": "Base-layout boundary beneath the blue proposed revision. Reconcile the selected design before ordering. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room132/floor"
    },
    {
      "id": "walls-132",
      "label": "132 · gross room wall faces",
      "quantity": 50.949729600127874,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            1443,
            758
          ],
          [
            1517,
            758
          ],
          [
            1517,
            854
          ],
          [
            1443,
            854
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-134",
      "label": "134 · Mechanical · base · floor/ceiling",
      "quantity": 58.20508530170737,
      "unit": "SF",
      "color": "#58a7ad",
      "polygons": [
        [
          [
            1521,
            758
          ],
          [
            1548,
            758
          ],
          [
            1548,
            854
          ],
          [
            1521,
            854
          ]
        ]
      ],
      "basis": "Base-layout boundary beneath the blue proposed revision. Reconcile the selected design before ordering. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room134/floor"
    },
    {
      "id": "walls-134",
      "label": "134 · gross room wall faces",
      "quantity": 36.863627887151345,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            1521,
            758
          ],
          [
            1548,
            758
          ],
          [
            1548,
            854
          ],
          [
            1521,
            854
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-130",
      "label": "130 · Fitness · base · floor/ceiling",
      "quantity": 762.1902026661079,
      "unit": "SF",
      "color": "#58a7ad",
      "polygons": [
        [
          [
            1357,
            758
          ],
          [
            1437,
            758
          ],
          [
            1437,
            859
          ],
          [
            1550,
            859
          ],
          [
            1550,
            993
          ],
          [
            1357,
            993
          ]
        ]
      ],
      "basis": "Base-layout boundary beneath the blue proposed revision. Reconcile the selected design before ordering. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room130/floor"
    },
    {
      "id": "walls-130",
      "label": "130 · gross room wall faces",
      "quantity": 128.27343687561606,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            1357,
            758
          ],
          [
            1437,
            758
          ],
          [
            1437,
            859
          ],
          [
            1550,
            859
          ],
          [
            1550,
            993
          ],
          [
            1357,
            993
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-001",
      "label": "001 · Stair 2 · floor/ceiling",
      "quantity": 141.87489542291172,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            344,
            758
          ],
          [
            461,
            758
          ],
          [
            461,
            812
          ],
          [
            344,
            812
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room001/floor"
    },
    {
      "id": "walls-001",
      "label": "001 · gross room wall faces",
      "quantity": 51.24943389189333,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            344,
            758
          ],
          [
            461,
            758
          ],
          [
            461,
            812
          ],
          [
            344,
            812
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-002",
      "label": "002 · Stair 1 · floor/ceiling",
      "quantity": 136.86728198838983,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            1495,
            572
          ],
          [
            1548,
            572
          ],
          [
            1548,
            687
          ],
          [
            1495,
            687
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room002/floor"
    },
    {
      "id": "walls-002",
      "label": "002 · gross room wall faces",
      "quantity": 50.35032101659696,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            1495,
            572
          ],
          [
            1548,
            572
          ],
          [
            1548,
            687
          ],
          [
            1495,
            687
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-003",
      "label": "003 · Elevator core · floor/ceiling",
      "quantity": 113.62566806583307,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            1444,
            572
          ],
          [
            1488,
            572
          ],
          [
            1488,
            687
          ],
          [
            1444,
            687
          ]
        ]
      ],
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room003/floor"
    },
    {
      "id": "walls-003",
      "label": "003 · gross room wall faces",
      "quantity": 47.652982390707834,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            1444,
            572
          ],
          [
            1488,
            572
          ],
          [
            1488,
            687
          ],
          [
            1444,
            687
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-015",
      "label": "015 · Pool equipment · A1.4 · floor/ceiling",
      "quantity": 48.999557104659004,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            444.1245,
            1067.873
          ],
          [
            490.837,
            1067.873
          ],
          [
            490.837,
            1114.5855
          ],
          [
            444.1245,
            1114.5855
          ]
        ]
      ],
      "basis": "Linked from the detailed A1.4 takeoff for the same room; do not add this footprint a second time. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room015/floor"
    },
    {
      "id": "walls-015",
      "label": "015 · gross room wall faces",
      "quantity": 27.999873458187874,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            444.1245,
            1067.873
          ],
          [
            490.837,
            1067.873
          ],
          [
            490.837,
            1114.5855
          ],
          [
            444.1245,
            1114.5855
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    },
    {
      "id": "room-017",
      "label": "017 · Unisex restroom · A1.4 · floor/ceiling",
      "quantity": 64.8430267572109,
      "unit": "SF",
      "color": "#64b85b",
      "polygons": [
        [
          [
            941.5585000000001,
            1063.893
          ],
          [
            999.2539999999999,
            1063.893
          ],
          [
            999.2539999999999,
            1113.942
          ],
          [
            941.5585000000001,
            1113.942
          ]
        ]
      ],
      "basis": "Linked from the detailed A1.4 takeoff for the same room; do not add this footprint a second time. Same projected area retained for ceiling takeoff; select ceiling construction from its plan.",
      "scopeKey": "bradenton/room017/floor"
    },
    {
      "id": "walls-017",
      "label": "017 · gross room wall faces",
      "quantity": 32.29148906412333,
      "unit": "LF",
      "color": "#ba9138",
      "polygons": [
        [
          [
            941.5585000000001,
            1063.893
          ],
          [
            999.2539999999999,
            1063.893
          ],
          [
            999.2539999999999,
            1113.942
          ],
          [
            941.5585000000001,
            1113.942
          ]
        ]
      ],
      "basis": "Gross enclosing wall-face perimeter, not unique framing length. Shared room walls legitimately have faces in both rooms. Deduct doors/openings and apply actual wall heights and assemblies separately."
    }
  ],
  "roomRegister": [
    {
      "id": "101",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          344,
          525
        ],
        [
          420,
          525
        ],
        [
          420,
          716
        ],
        [
          344,
          716
        ]
      ],
      "floorFootprintSF": 325.9664422220618,
      "ceilingFootprintSF": 325.9664422220618,
      "grossWallFaceRunLF": 80.0210459013773,
      "scopeKey": "bradenton/room101",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "103",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          428,
          525
        ],
        [
          506,
          525
        ],
        [
          506,
          716
        ],
        [
          428,
          716
        ]
      ],
      "floorFootprintSF": 334.54450649106343,
      "ceilingFootprintSF": 334.54450649106343,
      "grossWallFaceRunLF": 80.62045448490822,
      "scopeKey": "bradenton/room103",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "105",
      "name": "Connecting king studio",
      "kind": "enclosed",
      "polygon": [
        [
          513,
          525
        ],
        [
          590,
          525
        ],
        [
          590,
          716
        ],
        [
          513,
          716
        ]
      ],
      "floorFootprintSF": 330.2554743565626,
      "ceilingFootprintSF": 330.2554743565626,
      "grossWallFaceRunLF": 80.32075019314277,
      "scopeKey": "bradenton/room105",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "107",
      "name": "Accessible king one-bedroom",
      "kind": "enclosed",
      "polygon": [
        [
          598,
          560
        ],
        [
          760,
          560
        ],
        [
          760,
          716
        ],
        [
          598,
          716
        ]
      ],
      "floorFootprintSF": 567.4995816916469,
      "ceilingFootprintSF": 567.4995816916469,
      "grossWallFaceRunLF": 95.30596478141567,
      "scopeKey": "bradenton/room107",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "102",
      "name": "King one-bedroom",
      "kind": "enclosed",
      "polygon": [
        [
          465,
          758
        ],
        [
          505,
          758
        ],
        [
          505,
          950
        ],
        [
          344,
          950
        ],
        [
          344,
          820
        ],
        [
          465,
          820
        ]
      ],
      "floorFootprintSF": 525.6871322966704,
      "ceilingFootprintSF": 525.6871322966704,
      "grossWallFaceRunLF": 105.7956149932067,
      "scopeKey": "bradenton/room102",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "104",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          514,
          758
        ],
        [
          590,
          758
        ],
        [
          590,
          950
        ],
        [
          514,
          950
        ]
      ],
      "floorFootprintSF": 327.6730728096119,
      "ceilingFootprintSF": 327.6730728096119,
      "grossWallFaceRunLF": 80.32075019314277,
      "scopeKey": "bradenton/room104",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "106",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          598,
          758
        ],
        [
          675,
          758
        ],
        [
          675,
          950
        ],
        [
          598,
          950
        ]
      ],
      "floorFootprintSF": 331.98456060973837,
      "ceilingFootprintSF": 331.98456060973837,
      "grossWallFaceRunLF": 80.62045448490822,
      "scopeKey": "bradenton/room106",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "108",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          683,
          758
        ],
        [
          760,
          758
        ],
        [
          760,
          950
        ],
        [
          683,
          950
        ]
      ],
      "floorFootprintSF": 331.98456060973837,
      "ceilingFootprintSF": 331.98456060973837,
      "grossWallFaceRunLF": 80.62045448490822,
      "scopeKey": "bradenton/room108",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "110",
      "name": "King studio",
      "kind": "enclosed",
      "polygon": [
        [
          769,
          758
        ],
        [
          845,
          758
        ],
        [
          845,
          950
        ],
        [
          769,
          950
        ]
      ],
      "floorFootprintSF": 327.6730728096119,
      "ceilingFootprintSF": 327.6730728096119,
      "grossWallFaceRunLF": 80.32075019314277,
      "scopeKey": "bradenton/room110",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "112",
      "name": "Connecting king studio",
      "kind": "enclosed",
      "polygon": [
        [
          853,
          758
        ],
        [
          929,
          758
        ],
        [
          929,
          950
        ],
        [
          853,
          950
        ]
      ],
      "floorFootprintSF": 327.6730728096119,
      "ceilingFootprintSF": 327.6730728096119,
      "grossWallFaceRunLF": 80.32075019314277,
      "scopeKey": "bradenton/room112",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "114",
      "name": "Connecting king studio",
      "kind": "enclosed",
      "polygon": [
        [
          937,
          758
        ],
        [
          1013,
          758
        ],
        [
          1013,
          950
        ],
        [
          937,
          950
        ]
      ],
      "floorFootprintSF": 327.6730728096119,
      "ceilingFootprintSF": 327.6730728096119,
      "grossWallFaceRunLF": 80.32075019314277,
      "scopeKey": "bradenton/room114",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "109",
      "name": "Mechanical",
      "kind": "enclosed",
      "polygon": [
        [
          770,
          525
        ],
        [
          844,
          525
        ],
        [
          844,
          632
        ],
        [
          770,
          632
        ]
      ],
      "floorFootprintSF": 177.80396042396566,
      "ceilingFootprintSF": 177.80396042396566,
      "grossWallFaceRunLF": 54.246476809547914,
      "scopeKey": "bradenton/room109",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "111",
      "name": "Engineer",
      "kind": "enclosed",
      "polygon": [
        [
          770,
          638
        ],
        [
          844,
          638
        ],
        [
          844,
          693
        ],
        [
          770,
          693
        ]
      ],
      "floorFootprintSF": 91.39455909643094,
      "ceilingFootprintSF": 91.39455909643094,
      "grossWallFaceRunLF": 38.661853637744095,
      "scopeKey": "bradenton/room111",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "113",
      "name": "Electrical",
      "kind": "enclosed",
      "polygon": [
        [
          852,
          525
        ],
        [
          929,
          525
        ],
        [
          929,
          608
        ],
        [
          852,
          608
        ]
      ],
      "floorFootprintSF": 143.51415901358482,
      "ceilingFootprintSF": 143.51415901358482,
      "grossWallFaceRunLF": 47.95268668247329,
      "scopeKey": "bradenton/room113",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "115",
      "name": "PBX",
      "kind": "enclosed",
      "polygon": [
        [
          852,
          615
        ],
        [
          929,
          615
        ],
        [
          929,
          660
        ],
        [
          852,
          660
        ]
      ],
      "floorFootprintSF": 77.80888139290742,
      "ceilingFootprintSF": 77.80888139290742,
      "grossWallFaceRunLF": 36.56392359538589,
      "scopeKey": "bradenton/room115",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "117",
      "name": "Employee breakroom",
      "kind": "enclosed",
      "polygon": [
        [
          938,
          525
        ],
        [
          1012,
          525
        ],
        [
          1012,
          607
        ],
        [
          938,
          607
        ]
      ],
      "floorFootprintSF": 136.26097901649703,
      "ceilingFootprintSF": 136.26097901649703,
      "grossWallFaceRunLF": 46.75386951541146,
      "scopeKey": "bradenton/room117",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "119",
      "name": "Food prep",
      "kind": "enclosed",
      "polygon": [
        [
          852,
          665
        ],
        [
          934,
          665
        ],
        [
          934,
          615
        ],
        [
          1012,
          615
        ],
        [
          1012,
          716
        ],
        [
          852,
          716
        ]
      ],
      "floorFootprintSF": 270.81532744544404,
      "ceilingFootprintSF": 270.81532744544404,
      "grossWallFaceRunLF": 78.22282015078456,
      "scopeKey": "bradenton/room119",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "121",
      "name": "Proposed sprinkler room",
      "kind": "enclosed",
      "polygon": [
        [
          1021,
          525
        ],
        [
          1117,
          525
        ],
        [
          1117,
          568
        ],
        [
          1021,
          568
        ]
      ],
      "floorFootprintSF": 92.69698770271914,
      "ceilingFootprintSF": 92.69698770271914,
      "grossWallFaceRunLF": 41.65889655539868,
      "scopeKey": "bradenton/room121",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "125",
      "name": "Dryer room",
      "kind": "enclosed",
      "polygon": [
        [
          1122,
          525
        ],
        [
          1193,
          525
        ],
        [
          1193,
          560
        ],
        [
          1122,
          560
        ]
      ],
      "floorFootprintSF": 55.80232907976189,
      "ceilingFootprintSF": 55.80232907976189,
      "grossWallFaceRunLF": 31.768654927138556,
      "scopeKey": "bradenton/room125",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "127",
      "name": "Laundry",
      "kind": "enclosed",
      "polygon": [
        [
          1021,
          572
        ],
        [
          1117,
          572
        ],
        [
          1117,
          570
        ],
        [
          1198,
          570
        ],
        [
          1198,
          525
        ],
        [
          1295,
          525
        ],
        [
          1295,
          607
        ],
        [
          1021,
          607
        ]
      ],
      "floorFootprintSF": 321.36303076880176,
      "ceilingFootprintSF": 321.36303076880176,
      "grossWallFaceRunLF": 106.69472786850308,
      "scopeKey": "bradenton/room127",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "131",
      "name": "Laundry discharge",
      "kind": "enclosed",
      "polygon": [
        [
          1303,
          525
        ],
        [
          1377,
          525
        ],
        [
          1377,
          590
        ],
        [
          1303,
          590
        ]
      ],
      "floorFootprintSF": 108.01175165941838,
      "ceilingFootprintSF": 108.01175165941838,
      "grossWallFaceRunLF": 41.65889655539868,
      "scopeKey": "bradenton/room131",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "133",
      "name": "Manager office",
      "kind": "enclosed",
      "polygon": [
        [
          1303,
          615
        ],
        [
          1377,
          615
        ],
        [
          1377,
          657
        ],
        [
          1303,
          657
        ]
      ],
      "floorFootprintSF": 69.79220876454727,
      "ceilingFootprintSF": 69.79220876454727,
      "grossWallFaceRunLF": 34.76569784479314,
      "scopeKey": "bradenton/room133",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "136",
      "name": "Servery zone",
      "kind": "open",
      "polygon": [
        [
          1021,
          615
        ],
        [
          1157,
          615
        ],
        [
          1157,
          643
        ],
        [
          1021,
          643
        ]
      ],
      "floorFootprintSF": 85.51117470250836,
      "ceilingFootprintSF": 85.51117470250836,
      "grossWallFaceRunLF": 49.151503849535125,
      "scopeKey": "bradenton/room136",
      "basis": "Functional open-zone boundary traced around the named area; confirm finish transitions. Do not sum open zones into a building total."
    },
    {
      "id": "123",
      "name": "Breakfast/servery zone",
      "kind": "open",
      "polygon": [
        [
          1021,
          649
        ],
        [
          1150,
          649
        ],
        [
          1150,
          716
        ],
        [
          1021,
          716
        ]
      ],
      "floorFootprintSF": 194.0843180025682,
      "ceilingFootprintSF": 194.0843180025682,
      "grossWallFaceRunLF": 58.74204118602979,
      "scopeKey": "bradenton/room123",
      "basis": "Functional open-zone boundary traced around the named area; confirm finish transitions. Do not sum open zones into a building total."
    },
    {
      "id": "137",
      "name": "Work-station zone",
      "kind": "open",
      "polygon": [
        [
          1159,
          615
        ],
        [
          1295,
          615
        ],
        [
          1295,
          658
        ],
        [
          1159,
          658
        ]
      ],
      "floorFootprintSF": 131.32073257885213,
      "ceilingFootprintSF": 131.32073257885213,
      "grossWallFaceRunLF": 53.647068226017,
      "scopeKey": "bradenton/room137",
      "basis": "Functional open-zone boundary traced around the named area; confirm finish transitions. Do not sum open zones into a building total."
    },
    {
      "id": "129",
      "name": "Market zone",
      "kind": "open",
      "polygon": [
        [
          1159,
          664
        ],
        [
          1271,
          664
        ],
        [
          1271,
          717
        ],
        [
          1159,
          717
        ]
      ],
      "floorFootprintSF": 133.2968311539101,
      "ceilingFootprintSF": 133.2968311539101,
      "grossWallFaceRunLF": 49.45120814130058,
      "scopeKey": "bradenton/room129",
      "basis": "Functional open-zone boundary traced around the named area; confirm finish transitions. Do not sum open zones into a building total."
    },
    {
      "id": "116",
      "name": "Women restroom",
      "kind": "enclosed",
      "polygon": [
        [
          1051,
          783
        ],
        [
          1099,
          783
        ],
        [
          1099,
          828
        ],
        [
          1051,
          828
        ]
      ],
      "floorFootprintSF": 48.50423775142281,
      "ceilingFootprintSF": 48.50423775142281,
      "grossWallFaceRunLF": 27.872499134187603,
      "scopeKey": "bradenton/room116",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "118",
      "name": "Men restroom",
      "kind": "enclosed",
      "polygon": [
        [
          1051,
          835
        ],
        [
          1100,
          835
        ],
        [
          1100,
          877
        ],
        [
          1051,
          877
        ]
      ],
      "floorFootprintSF": 46.21375985760562,
      "ceilingFootprintSF": 46.21375985760562,
      "grossWallFaceRunLF": 27.273090550656686,
      "scopeKey": "bradenton/room118",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "120",
      "name": "Storage",
      "kind": "enclosed",
      "polygon": [
        [
          1051,
          883
        ],
        [
          1099,
          883
        ],
        [
          1099,
          926
        ],
        [
          1051,
          926
        ]
      ],
      "floorFootprintSF": 46.34849385135957,
      "ceilingFootprintSF": 46.34849385135957,
      "grossWallFaceRunLF": 27.273090550656686,
      "scopeKey": "bradenton/room120",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "122",
      "name": "Sales",
      "kind": "enclosed",
      "polygon": [
        [
          1051,
          933
        ],
        [
          1100,
          933
        ],
        [
          1100,
          992
        ],
        [
          1051,
          992
        ]
      ],
      "floorFootprintSF": 64.91932932377932,
      "ceilingFootprintSF": 64.91932932377932,
      "grossWallFaceRunLF": 32.36806351066947,
      "scopeKey": "bradenton/room122",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "128",
      "name": "Mechanical closet",
      "kind": "enclosed",
      "polygon": [
        [
          1268,
          940
        ],
        [
          1288,
          940
        ],
        [
          1288,
          995
        ],
        [
          1268,
          995
        ]
      ],
      "floorFootprintSF": 24.70123218822458,
      "ceilingFootprintSF": 24.70123218822458,
      "grossWallFaceRunLF": 22.477821882409355,
      "scopeKey": "bradenton/room128",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "126",
      "name": "Vestibule",
      "kind": "enclosed",
      "polygon": [
        [
          1294,
          938
        ],
        [
          1350,
          938
        ],
        [
          1350,
          993
        ],
        [
          1294,
          993
        ]
      ],
      "floorFootprintSF": 69.16345012702882,
      "ceilingFootprintSF": 69.16345012702882,
      "grossWallFaceRunLF": 33.26717638596585,
      "scopeKey": "bradenton/room126",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "124",
      "name": "Lobby/common zone",
      "kind": "open",
      "polygon": [
        [
          1106,
          723
        ],
        [
          1436,
          723
        ],
        [
          1436,
          753
        ],
        [
          1350,
          753
        ],
        [
          1350,
          995
        ],
        [
          1294,
          995
        ],
        [
          1294,
          934
        ],
        [
          1264,
          934
        ],
        [
          1264,
          995
        ],
        [
          1126,
          995
        ],
        [
          1126,
          758
        ],
        [
          1106,
          758
        ]
      ],
      "floorFootprintSF": 1400.7395103973388,
      "ceilingFootprintSF": 1400.7395103973388,
      "grossWallFaceRunLF": 198.7039454404987,
      "scopeKey": "bradenton/room124",
      "basis": "Functional open-zone boundary traced around the named area; confirm finish transitions. Do not sum open zones into a building total."
    },
    {
      "id": "135",
      "name": "TV lounge · base",
      "kind": "base",
      "polygon": [
        [
          1442,
          697
        ],
        [
          1548,
          697
        ],
        [
          1548,
          750
        ],
        [
          1442,
          750
        ]
      ],
      "floorFootprintSF": 126.15592948495062,
      "ceilingFootprintSF": 126.15592948495062,
      "grossWallFaceRunLF": 47.652982390707834,
      "scopeKey": "bradenton/room135",
      "basis": "Base-layout boundary beneath the blue proposed revision. Reconcile the selected design before ordering."
    },
    {
      "id": "132",
      "name": "Guest laundry · base",
      "kind": "base",
      "polygon": [
        [
          1443,
          758
        ],
        [
          1517,
          758
        ],
        [
          1517,
          854
        ],
        [
          1443,
          854
        ]
      ],
      "floorFootprintSF": 159.52504860467945,
      "ceilingFootprintSF": 159.52504860467945,
      "grossWallFaceRunLF": 50.949729600127874,
      "scopeKey": "bradenton/room132",
      "basis": "Base-layout boundary beneath the blue proposed revision. Reconcile the selected design before ordering."
    },
    {
      "id": "134",
      "name": "Mechanical · base",
      "kind": "base",
      "polygon": [
        [
          1521,
          758
        ],
        [
          1548,
          758
        ],
        [
          1548,
          854
        ],
        [
          1521,
          854
        ]
      ],
      "floorFootprintSF": 58.20508530170737,
      "ceilingFootprintSF": 58.20508530170737,
      "grossWallFaceRunLF": 36.863627887151345,
      "scopeKey": "bradenton/room134",
      "basis": "Base-layout boundary beneath the blue proposed revision. Reconcile the selected design before ordering."
    },
    {
      "id": "130",
      "name": "Fitness · base",
      "kind": "base",
      "polygon": [
        [
          1357,
          758
        ],
        [
          1437,
          758
        ],
        [
          1437,
          859
        ],
        [
          1550,
          859
        ],
        [
          1550,
          993
        ],
        [
          1357,
          993
        ]
      ],
      "floorFootprintSF": 762.1902026661079,
      "ceilingFootprintSF": 762.1902026661079,
      "grossWallFaceRunLF": 128.27343687561606,
      "scopeKey": "bradenton/room130",
      "basis": "Base-layout boundary beneath the blue proposed revision. Reconcile the selected design before ordering."
    },
    {
      "id": "001",
      "name": "Stair 2",
      "kind": "enclosed",
      "polygon": [
        [
          344,
          758
        ],
        [
          461,
          758
        ],
        [
          461,
          812
        ],
        [
          344,
          812
        ]
      ],
      "floorFootprintSF": 141.87489542291172,
      "ceilingFootprintSF": 141.87489542291172,
      "grossWallFaceRunLF": 51.24943389189333,
      "scopeKey": "bradenton/room001",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "002",
      "name": "Stair 1",
      "kind": "enclosed",
      "polygon": [
        [
          1495,
          572
        ],
        [
          1548,
          572
        ],
        [
          1548,
          687
        ],
        [
          1495,
          687
        ]
      ],
      "floorFootprintSF": 136.86728198838983,
      "ceilingFootprintSF": 136.86728198838983,
      "grossWallFaceRunLF": 50.35032101659696,
      "scopeKey": "bradenton/room002",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "003",
      "name": "Elevator core",
      "kind": "enclosed",
      "polygon": [
        [
          1444,
          572
        ],
        [
          1488,
          572
        ],
        [
          1488,
          687
        ],
        [
          1444,
          687
        ]
      ],
      "floorFootprintSF": 113.62566806583307,
      "ceilingFootprintSF": 113.62566806583307,
      "grossWallFaceRunLF": 47.652982390707834,
      "scopeKey": "bradenton/room003",
      "basis": "Traced gross room/suite footprint between enclosing walls; internal bath/closet partitions remain within suite area. Apply finish-zone and opening deductions on enlarged details."
    },
    {
      "id": "015",
      "name": "Pool equipment · A1.4",
      "kind": "linked",
      "polygon": [
        [
          444.1245,
          1067.873
        ],
        [
          490.837,
          1067.873
        ],
        [
          490.837,
          1114.5855
        ],
        [
          444.1245,
          1114.5855
        ]
      ],
      "floorFootprintSF": 48.999557104659004,
      "ceilingFootprintSF": 48.999557104659004,
      "grossWallFaceRunLF": 27.999873458187874,
      "scopeKey": "bradenton/room015",
      "basis": "Linked from the detailed A1.4 takeoff for the same room; do not add this footprint a second time."
    },
    {
      "id": "017",
      "name": "Unisex restroom · A1.4",
      "kind": "linked",
      "polygon": [
        [
          941.5585000000001,
          1063.893
        ],
        [
          999.2539999999999,
          1063.893
        ],
        [
          999.2539999999999,
          1113.942
        ],
        [
          941.5585000000001,
          1113.942
        ]
      ],
      "floorFootprintSF": 64.8430267572109,
      "ceilingFootprintSF": 64.8430267572109,
      "grossWallFaceRunLF": 32.29148906412333,
      "scopeKey": "bradenton/room017",
      "basis": "Linked from the detailed A1.4 takeoff for the same room; do not add this footprint a second time."
    }
  ],
  "wallAssignmentStatus": "No W1–W6 tags were found on A2.1. Quantities remain organized by traced wall function/room face, with exact assembly assignment open. Never infer CMU versus stud solely from line weight.",
  "sourceViews": {
    "original": "a21-source.png",
    "roomTracing": "a21-room-tracing.svg",
    "method": "Derived heavy neutral vector linework with room/door text. Furniture, thin lines and blue review markup suppressed. This is a tracing aid, not a revised source drawing."
  },
  "reuseRule": "Keep room footprints, gross wall-face runs and unique construction-wall runs separate. Do not sum these different measures or duplicate A1.4 pool-room quantities."
}