205 N. Orange Ave, Suite 301, Sarasota, FL 34236 LEVEL LANDING AREA (1:48 MAX. IN ALL DIRECTIONS) CURB RAMP, 1:12 MAX CROSS SLOPE 1:48 MAX FLARED SIDES 1:10 MAX SLOPE DETECTABLE WARNING SURAFCE (WHERE REQUIRED - RE STATE/LOCAL CODES) DETECTABLE WARNING SURFACE (WHERE REQUIRED ~ RE: STATE/LOCAL CODES) DETECTABLE WARNING SURFACE (WHERE REQUIRED ~ RE: STATE/LOCAL CODES) CROSS SLOPE 1:48 MAX., TYP. 1:48 MAX. DEPRESSED CURB AND GUTTER RAMP 1:12 MAX. RAMP 1:12 MAX. 205 N. Orange Ave, Suite 301, Sarasota, FL 34236 3'-0" MIN. PAVED PARKWAY ARCHITECT: LEVEL LANDING AREA (1:48 MAX. IN ALL DIRECTIONS) CURB RAMP, 1:12 MAX. CROSS SLOPE 1:48 MAX. 3'-0" MIN. 3'-0" MIN. EXISTING STRUCTURE (WHERE APPLIES) FACE OF CURB FACE OF CURB EDGE OF GUTTER DEPRESSED CURB AND GUTTER EDGE OF GUTTER SITE DETAILS 1/4" = 1'-0" 4' MIN. WIDTH 1:20 MAX. SLOPE MAX. SLOPE 1:20 FACE OF CURB (BEYOND) SIDEWALK OR RAMP 1'-0" 1'-0" DETECTABLE WARNING SURFACE (WHERE REQUIRED ~ RE: STATE/LOCAL CODES) 10" TYP. DEPRESSED CURB 3/4" EXPANSION JOINT (P.J.M.) - MAKE FLUSH TO CONCRETE SURFACE WATER TIGHT STANDING SEAM METAL ROOF ON 30 LB FELT PAPER OVER EXT. GRADE PLYWOOD ON METAL `C' STUDS SLOPE ONE BLOCK COURSE EXTERIOR FINISH SYSTEM (E.F.S.) 6" DIAMETER STEEL PIPE, CONC. FILLED BOLLARDS - PAINTED 4" REINFORCED CONCRETE SLAB -- SLOPE 1/4" PER FOOT TO GARAGE DOOR -- REFER TO PLAN CONCRETE SLAB W/ REINFORCING -- SLOPE 1/4" PER FOOT TO AREA DRAIN -- REFER TO PLAN TURN SLAB EDGE DOWN 1/2" EXPANSION JT. W/ SEALANT DIAGONAL BRACING EA. SIDE DUMPSTER ENCLOSURE ELEVATIONS 1/4" = 1'-0" 1. VERIFY DRAINAGE REQUIREMENTS WITH HEALTH INSPECTOR 2. PROVIDE CEILING MOUNTED LIGHT AND DUPLEX OUTLET IN STORAGE 3. DUMPSTER ENCLOSURE EXTERIOR FINISH TO MATCH FINISH OF MAIN HOTEL / TOWER 4. ADDITIONAL SPACE MAY BE NEEDED FOR RECYCLING. DESIGNER TO COORDINATE REQUIREMENTS WITH LOCAL SERVICE 5. INTERIOR WALLS AND CEILINGS PAINTED FINISH AT MINIMUM FROST PROOF HOSE BIBB GRADE, MAINTAIN POSITIVE DRAINAGE TURN SLAB EDGE DOWN EXTERIOR FINISH SYSTEM (E.F.S.) 7'-0" WESTERN RED CEDAR OR EQUAL DROP ROD, 1" DIAMETER X 2'-0" LONG WITH 90 DEGREE BEND 8" REINFORCED CMU W/ TRUSS TYPE REINFORCING NOTES: REVISIONS No. Description Date METAL COPING TO MATCH ADJACENT WALL COLOR STEEL GATE POST EACH SIDE LOCKABLE HASP 8" CMU 'U' BLOCK 10'-0" TO TOP OF 'U' BLOCK ALL INTERIOR CMU SURFACES PAINTED CONTINUOUS REGLET AT ROOF FOR COUNTER FLASHING 8" CMU 'U' BLOCK 1'-4" TREATED WOOD BLOCKING AT TOP OF 8" 'U' BLOCK AS REQUIRED GALV. GUTTER AND DOWNSPOUT HOME 2 SUITES SITE DETAILS 2.0 1" = 1'-0" METAL COPING TO MATCH ADJACENT WALL COLOR OVER TREATED WOOD 1X BLOCKING AT TOP OF 8" 'U' BLOCK AS REQUIRED 3 SLOPE BRADENTON, FL. 7" MIN. 90% CONSTRUCTION DOCUMENTS - 04.30.2025 5" TYP. 12" GUTTER FLAG HOTEL BRAND: DASHED INDICATES CONC. GUTTER SOME LOCATIONS LANDSCAPE PLANTING ALLOW FOR 6" TOPSOIL OVER SUB-GRADE ROADWAY 3/8" MAX. ROLL EDGE PRIOR To STAMPING - TYP. DASHED INDICATES CONC. GUTTER SOME LOCATIONS 5" TYP. 4" 4" CONCRETE SIDEWALK W/ FINISH (PER PLAN) OVER MIN. 4" COMPACTED GRANULAR FILL ASPHALT (SHOWN) OR CONCRETE DRIVE AISLE, ROAD OR PARKING LOT 4" CONCRETE SIDEWALK WITH BROOM FINISH OVER 4" COMPACTED GRANULAR FILL ASPHALT (SHOWN) OR CONCRETE DRIVE AISLE, ROAD OR PARKING LOT 6" CURB -- ROLL EDGE PRIOR To STAMPING, TOOL EDGE AT BROOM FINISHED CONCRETE 2 EDGE OF GUTTER DEPRESSED CURB AND GUTTER 4" 1 FACE OF CURB 3'-0" MIN. DESIGN/BUILDER: 3'-0" MIN. 3'-0" MIN. 6'x7' MANUALLY OPERATED OVERHEAD GARAGE DOOR TO EXTERIOR STORAGE SPACE KRISTOPHER PELOW AR99671 & ID 6707 PROJECT NO: 210729 DRAWN BY: KJP CHECKED BY: KJP/EC ARCHITECTURAL SITE DETAILS A1.3