PARTITION TYPE NOTES PROVIDE MOISTURE RESISTANT GWB AT ALL 1. PARTITION TYPES ARE TAGGED ON THE FLOOR PLANS. BATHROOMS 2. REFER TO WALL SECTIONS FOR EXTERIOR WALL ASSEMBLIES. 205 N. Orange Ave, Suite 301, Sarasota, FL 34236 3. REFER TO “GYPSUM BOARD ASSEMBLIES” SPECIFICATION FOR FULL REQUIREMENTS FOR GYPSUM BOARD ASSEMBLIES AND NON- FLOOR/CEILING/ FRAMING PER FLOOR/CEILING/ FRAMING PER FLOOR/CEILING/ FRAMING PER LOAD-BEARING STEEL FRAMING MEMBERS FOR GYPSUM BOARD ROOF STRUCTURAL ROOF STRUCTURAL ROOF STRUCTURAL ASSEMBLIES. STRUCTURE STRUCTURE STRUCTURE 4. ALL STUDS AND FURRING CHANNELS ARE TO BE SPACED 16" O.C., UNLESS NOTED OTHERWISE. 5. ALL PARTITIONS SHALL EXTEND FROM FLOOR SLAB OR DECK TO ACOUSTIC/FIRE BOTTOM OF ACOUSTIC SEALANT ACOUSTIC/FIRE THE UNDERSIDE OF THE STRUCTURAL DECK TO ACHIEVE SEALANT (BOTH SIDES) DECK (BOTH SIDES) SEALANT (BOTH SIDES) COMPLETE CLOSURE, UNLESS NOTED OTHERWISE. ARCHITECT: 6. PARTITION TYPES DESCRIBE THE PRIMARY WALL MEMBER AND 5/8" GWB, TYPE SOUND SHEATHING. REFER TO FINISH SCHEDULE FOR ALL PARTITION 5/8" GWB, TYPE 5/8" GWB, TYPE 5/8" GWB, TYPE FINISH DESIGNATIONS. X, FIRE RATED, ATTENUATING BATT X, FIRE RATED, X, FIRE RATED, X, FIRE RATED, 7. PROVIDE TYPE “M-R” MOISTURE RESISTANT GYPSUM BACKING INSULATION ON RESILIENT SOUND ON RESILIENT SOUND ON RESILIENT SOUND BOARD IN ALL WET AREAS, INCLUDING TOILET, LOCKER AND CHANNELS ON ATTENUATING BATT CHANNELS ON ATTENUATING BATT CHANNELS ON ATTENUATING BATT SHOWER ROOMS. STUDS INSULATION STUDS INSULATION STUDS INSULATION 8. PROVIDE 1/2” CEMENT BOARD WITH WATER-RESISTANT COATING AS A SUBSTRATE FOR WALL AREAS SCHEDULED TO RECEIVE TILE. 9. CONSTRUCTION OF FIRE RATED PARTITIONS, INCLUDING TAPING CORRIDOR SIDE AND FINISHING OF GYPSUM BOARD, SHALL BE IN ACCORDANCE WITH U.L. SYSTEM ASSEMBLY OR OTHER APPROVED ASSEMBLY TO ACHIEVE THE RATING INDICATED. PROVIDE FIRESTOPPING PER ADDITIONAL 5/8" FIRESTOPPING MANUFACTURER’S RECOMMENDATIONS FOR 5/8" CDX PLYWOOD 5/8" CDX PLYWOOD GWB, TYPE X, 5/8" CDX PLYWOOD PENETRATIONS THROUGH RATED WALLS. FIRE RATED, ON 10. PROVIDE SLIP JOINT CONNECTIONS AT THE TOPS OF ALL 205 N. Orange Ave, Suite 301, Sarasota, FL 34236 RESILIENT PARTITIONS WHICH INTERSECT THE STRUCTURE ABOVE, CAPABLE CHANNELS ON OF ACCOMMODATING UPWARD AND DOWNWARD VERTICAL 5/8" GWB, TYPE X, 5/8" GWB, TYPE X, 5/8" GWB, TYPE X, STUDS 5/8" GWB, TYPE X, DISPLACEMENT OF PRIMARY STRUCTURE THROUGH POSITIVE FIRE RATED FIRE RATED, FIRE RATED FIRE RATED MECHANICAL ATTACHMENT TO STUD WEB. PROVIDE FIRE SAFING BASE PER BASE PER BASE PER AT ALL SLIP JOINT CONNECTIONS IN FIRE RATED PARTITIONS. SCHEDULE SCHEDULE SCHEDULE BASE PER SCHEDULE 11. PROVIDE GYPSUM BOARD CONTROL JOINTS WHERE DESIGNATED ON THE INTERIOR ELEVATIONS, AND ANYWHERE THERE IS A ACOUSTIC/FIRE ACOUSTIC SEALANT ACOUSTIC/FIRE CONTINUOUS RUN OF GYPSUM BOARD THAT IS GREATER THAN 30 TOP OF FLOOR SEALANT (BOTH SIDES) TOP OF FLOOR (BOTH SIDES) TOP OF FLOOR SEALANT (BOTH SIDES) TOP OF FLOOR FEET IN LENGTH. CONFIRM THE LOCATION OF ADDITIONAL CONTROL JOINTS WITH THE ARCHITECTURE PRIOR TO INSTALLATION. DESIGN/BUILDER: 12. IN PARTITIONS WHERE BATT INSULATION FOR SOUNDPROOFING IS W1 W2 W3 W4 INDICATED, SEAL CONSTRUCTION AT PERIMETERS, BEHIND CONTROL AND EXPANSION JOINTS, OPENINGS, AND PENETRATIONS WITH A CONTINUOUS BEAD OF ACOUSTICAL 1-HR RATED WALL (CORRIDOR WALLS) - STC 50 MIN. 1-HR RATED WALL, UL U305 1-HR RATED WALL (SHEAR WALL/PARTY WALL) 1-HR RATED WALL - STC 65 SEALANT, INCLUDING A BEAD AT BOTH FACES OF THE PARTITIONS. 13. AT METAL STUD WALLS, BLOCKING IS REQUIRED AT ALL WALL MOUNTED ITEMS INCLUDING, BUT NOT LIMITED TO, THE W1A W2A W3A FOLLOWING LOCATIONS: A. WALL MOUNTED COUNTERS AND COUNTERTOP SUPPORTS NO RATING - SIM. TO SHOWN SIM. TO SHOWN EXCEPT NO RATING SIM. TO SHOWN EXCEPT NO RATING B. WALL MOUNTED ACCESSORIES AND EQUIPMENT EXCEPT NO CDX PLYWOOD C. WALL MOUNTED DOORSTOPS D. WALL MOUNTED DOOR HOLD OPEN DEVICES AND/OR CLOSURES W1B E. TOILET ROOM PARTITIONS AND ACCESSORIES 1- HR RATING - SIM. TO SHOWN F. WALL MOUNTED TV / MONITORS AND BRACKETS EXCEPT NO CDX PLYWOOD HOTEL BRAND: 90% CONSTRUCTION DOCUMENTS - 04.30.2025 CONT. AIR/VAPOR BARRIER PAINTED PAINTED PAINTED HOME 2 SUITES 5/8" GWB 5/8" GWB 5/8" GWB REINFORCED CMU BLOCK BRADENTON, FL. WALL PER STRUCTURAL 1-5/8" METAL 1-5/8" METAL 1-5/8" METAL FURRING FURRING FURRING DIRECT APPLIED STUCCO SEE ELEVATIONS: FOR ALTERNATE FINISH MATERIALS/ BASE AS BASE AS BASE AS COLORS SCHEDULED SCHEDULED SCHEDULED FLOOR FLOOR FLOOR FINISH AS FINISH AS FINISH AS SCHEDULED SCHEDULED SCHEDULED W5 W5 W6 = SIM. BUT WITHOUT W6 = SIM. BUT WITHOUT INTERIOR FURRING & INTERIOR FURRING & INSULATION INSULATION REVISIONS No. Description Date WALL TYPES 1 1 1/2" = 1'-0" TYPICAL FLOOR ASSEMBLY (1-HOUR RATED) FLOORING PER FINISH UL L514 SPECIFICATIONS 1-1/2" GYPCRETE 3/4" OSB DECK WOOD STUD WALLS PER STRUCTURAL KRISTOPHER PELOW STRUCTURAL WOOD FRAMING PER AR99671 & ID 6707 SHEATHING PANELS STRUCTURAL PER STRUCTURAL PROJECT NO: 210729 DRAWN BY: KJP CHECKED BY: KJP/EC WALL TYPES & 3-1/2" SOUND BATT INSULATION FLOOR/CLG (1) LAYER 5/8" FIRECORE 1/2" RESILIENT CHANNELS @ 16" O.C. RATINGS TYPE C GWB A0.2